• Title/Summary/Keyword: The size of human body

Search Result 491, Processing Time 0.029 seconds

Pore Characterisitics and Adsorption Performance Evaluation of Magnesium Oxide Matrix by Active Carbon Particle Size (활성탄소 입도에 따른 산화마그네슘 경화체의 공극특성과 흡착성능 평가)

  • Pyeon, Su-Jeong;Lee, Sang-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.1
    • /
    • pp.59-65
    • /
    • 2018
  • Radon gas is a colorless, odorless, tasteless gas that occurs when uranium, a natural radioactive material in rocks and soils, collapses. 85% of the annual radiation exposure of the human body is due to natural radiation, of which 50% is radon. According to the US Environmental Protection Agency (EPA) survey, 62 out of 1,000 smokers and 7 out of 1,000 nonsmokers are exposed to lung cancer when exposed to radon gas for a long time. In order to reduce the risk of radon gas, activate carbon was used to fabricate matrix, and the pore properties and radon reduction properties were investigated. When the activate carbon was used, the radon gas concentration was drastically reduced and the graph was changed as the measurement period became longer. The pore distribution and microporous properties, which are one of the material properties of activate carbon, can be grasped.

Arm Armor System Performance Study: Net Effect (Perceptual Response) Analysis

  • Nam, Jin-Hee;Peksoz, Semra;Branson, Donna H.;Cao, Huantian
    • International Journal of Human Ecology
    • /
    • v.13 no.1
    • /
    • pp.117-128
    • /
    • 2012
  • This study compares the net effect of wearing different shoulder/arm armor systems on garment impediment perception and wearer acceptability. Two independent variables in this study were armor systems and shoulder/ arm movements. There were four armor systems of control garment and arm armor systems A, B, and C as well as five types of arm/shoulder movements, (shoulder flexion, should extension, shoulder abduction, shoulder horizontal flexion, and shoulder horizontal extension). Ten male volunteers wearing size medium battle dress uniform (BDU) with recent relevant military experience participated in this study. The volunteers performed shoulder/arm movements (while wearing each armor treatments) and completed the garment impediment perception as well as wearer acceptability scales. The body areas of neck side, shoulder top, and armscye front showed the highest frequency of reported impediments. Resistance to movement and localized pressure were the most frequently mentioned types of impediment. The armor system B had the most areas of impediment, and was rated as more restrictive than the control garment and armor system A for each movement. For wearer acceptability, no significant differences were found between the control garment and armor system A for all eight items; this indicated that subjects did not perceive a difference between wearing the control garment and armor system A. There was a trend for wearer acceptability to decrease from wearing the control garment to armor systems A to C to B.

Efficient Design of Plate Spring for Improving Performance of Sound Wave Vibration Massage Chair (음파진동 안마의자제품의 성능향상을 위한 판스프링의 효율적 설계)

  • Kim, Chang-Gyum;Park, Soo-Yong;Jo, Eun-Hyeon;Lee, Dong-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.4
    • /
    • pp.1-7
    • /
    • 2019
  • The customer of massage chair is expanding day by day from middle age to all ages. In 2018, the market size was 700 billion KRW, an increase of 30 times over 10 years. However, most related SMEs suffer from excessive competition by the market monopoly of some major companies. In this situation, in order for a related company to survive, it is necessary to steadily research and develop new products. Founded in 2009, company L produces massage chairs for health and relaxation of customers. L's products use a sound wave vibration module that is favorable for human body, unlike other products that use vibration motor type. However, frequent breakdowns of massage chair due to the vulnerability of plate (leaf) springs, which play an important role in sound wave vibration modules, made sap its competitiveness. In this paper, we propose a method to design desirable plate spring structure by sequentially experimenting with five different plate springs. The results of this study are expected to contribute to improve the quality of plate spring and the reliability of sound wave vibration module. In the future, it is necessary to find a way to use it in the development of foot massage or scalp management device as well as continuous research to find optimal plate spring structure through various analysis.

Fabrication of Porous β-TCP Bone Graft Substitutes Using PMMA Powder and their Biocompatibility Study (PMMA를 이용한 다공질 β-TCP 골충진제 제조 및 생체적합성 평가)

  • Song, Ho-Yeon;Youn, Min-Ho;Kim, Young-Hee;Min, Young-Ki;Yang, Hun-Mo;Lee, Byong-Taek
    • Korean Journal of Materials Research
    • /
    • v.17 no.6
    • /
    • pp.318-322
    • /
    • 2007
  • Porous ${\beta}-tricalcium$ phosphate $({\beta}-TCP)$ bioceramic was fabricated by pressureless sintering using commercial HAp and different volume percentages of PMMA powders (30-60 vol.%). The range of spherical pore size was about $200-250\;{\mu}m$ in diameter. By increasing the PMMA content, the number of pores and their morphology were dramatically changed as well as decreased the material properties. In case of using 60 vol.% PMMA content, network-type pores were found, due to the necking of the PMMA powders. The values of relative density, elastic modulus, bending strength and hardness of the 60 vol.% PMMA content sample, sintered at $1500^{\circ}C$, were about 46%, 22.2 GPa, 5MPa and 182 Hv respectively. Human osteoblast-like MG-63 cells and osteoclast-like Raw 264.7 cells were well grown and fully covered all of the porous ${\beta}-TCP$ bodies sintered at $1500^{\circ}C$.

Development of Polymeric Nanopaclitaxel and Comparison with Free Paclitaxel for Effects on Cell Proliferation of MCF-7 and B16F0 Carcinoma Cells

  • Yadav, Deepak;Anwar, Mohammad Faiyaz;Garg, Veena;Kardam, Hemant;Beg, Mohd Nadeem;Suri, Suruchi;Gaur, Sikha;Asif, Mohd
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.5
    • /
    • pp.2335-2340
    • /
    • 2014
  • Paclitaxel is hydrophobic in nature and is recognized as a highly toxic anticancer drug, showing adverse effects in normal body sites. In this study, we developed a polymeric nano drug carrier for safe delivery of the paclitaxel to the cancer that releases the drug in a sustained manner and reduces side effects. N-isopropylacrylamide/vinyl pyrrolidone (NIPAAm/VP) nanoparticles were synthesized by radical polymerization. Physicochemical characterization of the polymeric nanoparticles was conducted using dynamic light scattering, transmission electron microscopy, scanning electron microscopy and nuclear magnetic resonance, which confirmedpolymerization of formulated nanoparticles. Drug release was assessed using a spectrophotometer and cell viability assays were carried out on the MCF-7 breast cancer and B16F0 skin cancer cell lines. NIPAAm/VP nanoparticles demonstrated a size distribution in the 65-108 nm range and surface charge measured -15.4 mV. SEM showed the nanoparticles to be spherical in shape with a slow drug release of ~70% in PBS at $38^{\circ}C$ over 96 h. Drug loaded nanoparticles were associated with increased viability of MCF-7 and B16F0 cells in comparison to free paclitaxel. Nano loaded paclitaxel shows high therapeutic efficiency by sustained release action for the longer period of time, i increasing its efficacy and biocompatibility for human cancer therapy. Therefore, paclitaxel loaded (NIPAAm/VP) nanoparticles may provide opportunities to expand delivery of the drug for clinical selection.

LED Fiber-Optic Lighting Devices Developed for Medical Assistance for the Local Treatment Retractor (국부치료를 위한 Retractor용 LED 광섬유 의료보조조명 장치 개발)

  • Eo, Ik-soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.666-671
    • /
    • 2016
  • This paper introduces a device providing close local lighting to the affected part, where the operation-purpose astral lamp alone cannot shed light directly, in an operation room of hospitals or clinics, which helps clinical doctors perform safe treatment of the affected part deep inside a human body. This medical assisting lighting is a device necessary to prevent fatal operation failures, which can occur with minute operation processes, such as tumor removal or angiorrhaphy. The components, such as the light source and power supply were designed to be low power consuming and small in size, have a narrow angle lens was used to increase the light spreading effect and focused illumination. The end-caps of the light transmission device using an optical cable and the lighting device were designed in the waterproof type to enable disinfection of these devices after use for the next patients. According to the measurement of the light source properties made after development of the retractor lighting device, the illumination intensity was 490 lux, the brightness was $11,550cd/m^2$, general color rendering index was 78, color temperature was 11,000K, and the intensity distribution was even, which were confirmed to be adequate for medical assisting local lighting.

Anatomical and physiological changes in the aging eye (노인성 변화에 따른 안구와 해부생리학적 고찰)

  • Kim, Jai-Min;Seong, Jeong-Sub;Seo, Eun-Sun;Kho, Eun-Kyung;Lee, Seok-Ju;Yoo, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.135-143
    • /
    • 2004
  • The Human body is subject to two patterns of senescence, both of which are represented in the eye and vision. This article discusses the anatomical and physiological changes in anterior and posterior segments which occur with age. The areas covered include the globe, lids, tears, conjunctiva, cornea, sclera, anterior chamber angle, iris, lens, choroid, vitreous and retina. A sample of 219 individuals between the ages of 50 and 79 years was tested with case history, slit lamp examination, palpebral fissure, horizontal visible iris diameter(HVID) and pupil size. The palpebral fissure decreases with age while HVID remains constant in all age classes. This study suggests that an understanding of anatomical and physiological changes which occur with age is helpful to all eye clinicians because the aging process affects all of the ocular tissues.

  • PDF

Evaluation of Usefulness and Availability for Orthopedic Surgery using Clavicle Fracture Model Manufactured by Desktop 3D Printer (보급형 3D 프린터로 제작한 쇄골 골절 모델을 이용한 정형외과 수술에 대한 유용성과 활용가능성 평가)

  • Oh, Wang-Kyun
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.203-209
    • /
    • 2014
  • Usefulness and clinical availability for surgery efficiency were evaluated by conducting pre-operative planning with a model manufactured by desktop 3D printer by using clavicle CT image. The patient-customized clavicle fracture model was manufactured by desktop 3D printer of FDM wire laminated processing method by converting the CT image into STL file in Open Source DICOM Viewer Osirix. Also, the model of the original shape before damaged was restored and manufactured by Mirror technique based on STL file of not fractured clavicle of the other side by using the symmetry feature of the human body. For the model, the position and size, degree of the fracture was equally printed out. Using the clavicle model directly manufactured with low cost and less time in Department of Radiology is considered to be useful because it can reduce secondary damage during surgery and increase surgery efficiency with Minimal invasive percutaneous plate osteosynthesis(MIPO).

Applicator of Hyperthermia with Compact Dipole Antenna Array (소형화된 다이폴 안테나 배열 구조를 이용한 고온 온열 치료 전자기파 방사체)

  • Kim, Ki-Joon;Choi, Woo-Cheol;Choi, Jae-Hoon;Yoon, Young-Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.244-250
    • /
    • 2012
  • The compact dipole antenna elements and array structure is proposed. The array structure is designed for applicator in regional hyperthermia treatment to enhance the uniformity of the heat distribution which makes the treatment effective and prevents overheating. The compact dipole is designed with branched dipole and matching network to have small size and symmetric shape. The temperature simulation with specific absorption rate(SAR) and bio-heat equation is performed to have heat distribution. The applicator is designed, fabricated, and measured with multi-channel thermometer in 30 and 60 minutes. The simulation and measurement results showed agreement and the simulation in body circumstance has proper temperature result for hyperthermia therapy.

Preparation and Characterization of Casein Nanoparticles with Various Metal Ions as Drug Delivery Systems (다양한 금속 이온을 이용한 카세인 단백질 나노입자 형성 및 약물 전달체 특성 연구)

  • Minju Kim;Seulgi Lee;Joon Sig Choi
    • Applied Chemistry for Engineering
    • /
    • v.34 no.2
    • /
    • pp.121-125
    • /
    • 2023
  • Casein is a milk protein and one of the most important nutrients in milk. The composition is over 80% in cow's milk and about 20~45% in human's milk. Casein is highly biocompatible and biodegradable, so it has been studied for various biomedical materials applications as well as drug delivery systems. It is widely known that casein can be prepared as nanoparticles in the presence of the Ca2+ metal ion. Because casein is amphiphilic, hydrophobic drugs could be loaded inside to form a protein-based drug delivery system. In this study, we studied the optimum conditions for casein nanoparticle formation using natural metal ions present in the body, such as calcium, magnesium, zinc, and iron. It was confirmed that nanoparticles have a uniform size of around 150 nm and negative zeta potential values. In addition, it was demonstrated that casein nanoparticles have a cell viability of more than 80% and efficient intracellular uptake properties using confocal microscopy. From the results, it was also shown that the casein nanoparticles prepared using various metal ions have the potential to be biocompatible drug delivery carriers.