A Simple Solution of Lateral Buckling of an Elastica with Self-Contact (자기접촉을 가지는 일래스티카 기둥의 수평좌굴 해의 간단한 해법)

  • Jung, Jae-Ho;Kang, Tae-Jin;Lee, Kyung-Woo
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10b
    • /
    • pp.80-83
    • /
    • 2003
  • Exact Solution of lateral buckling of elastica column with self-contact was obtained. By assuming that there exists a counter force to maintain the horizontal coordinate at contact point to be the same value as that of highest point of bent beam, we could prevent the shape of solution from overlapping with each other. As the simpliest case, we obtained the elliptic integral solutions of the laterally post-buckled shape of linear elastic inextensible column under concentrated load. (omitted)

  • PDF

MATHEMATICAL ANALYSIS OF CONTACT PROBLEM WITH DAMPED RESPONSE OF AN ELECTRO-VISCOELASTIC ROD

  • LAHCEN OUMOUACHA;YOUSSEF MANDYLY;RACHID FAKHAR;EL HASSAN BENKHIRA
    • Journal of applied mathematics & informatics
    • /
    • v.42 no.2
    • /
    • pp.305-320
    • /
    • 2024
  • We consider a mathematical model which describes the quasistatic contact of electro-viscoelastic rod with an obstacle. We use a modified Kelvin-Voigt viscoelastic constitutive law in which the elasticity operator is nonlinear and locally Lipschitz continuous, taking into account the piezoelectric effect of the material. We model the contact with a general damped response condition. We establish a local existence and uniqueness result of the solution by using arguments of time-dependent nonlinear equations and Schauder's fixed-point theorem and obtain a global existence for small enough data.

A Study on Three-Dimensional Motion Tracking Technique for Floating Structures Using Digital Image Processing (디지털 화상처리를 이용한 부유식 구조물의 3차원운동 계측법에 관한 연구)

  • Jo, Hyo-Je;Do, Deok-Hui
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.2 s.28
    • /
    • pp.121-129
    • /
    • 1998
  • A quantitative non-contact multi-point measurement system is proposed to the measurement of three-dimensional movement of floating vessels by using digital image processing. The instantaneous three-dimensional movement of a floating structure which is floating in a small water tank is measured by this system and its three-dimensional movement is reconstructed by the measurement results. The validity of this system is verified by position identification for spatially distributed known positional values of basic landmarks set for the camera calibration. It is expected that this system is applicable to the non-contact measurement for an unsteady physical phenomenon especially for the measurement of three-dimensional movement of floating vessels in the laboratory model test.

  • PDF

Measurement of contact position between wheel and rail for clarification of derailment mechanism (탈선 매커니즘 해명을 위한 차륜/레일 접촉위치 측정)

  • Ham Young-Sam;Hong Jai-Sung;Lee Kwan-Sup;Seo Byung-Wook
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.608-612
    • /
    • 2004
  • Safety from derailment has been evaluated according to the magnitude of the derailment coefficient, which does not always ensure sufficient safety evaluation, and is not necessarily helpful in clarifying the mechanism of derailment. When wheel rolls, point of contact between wheel and rail was change continuously and flange touches with rail. Established gauge so that can measure location of contact point between wheel and rail by strain gauge. Also, wish to describe result that compose bridge circuit and execute load test.

  • PDF

A Study of Dynamic Characteristic Analysis Algorithm for Running Safety Assessment (주행안전성 평가를 위한 동특성 해석알고리즘 연구)

  • Chung J.D.;Han S.Y.;Chun H.J.;Pyun J.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.411-412
    • /
    • 2006
  • It is very difficult to analyze the dynamic characteristic because railway vehicle is a very complex system which are connected various mass element with railway vehicle system. To realize and analyze actual phenomenon has restriction that usual commercial software calculates creep force under creep theory about wheel-rail contact mechanism as basic analyzing, and approach about contact point are based on two dimensional non-linear contact theory and simplified Hertzian contact which considers just displacement change on the YZ plain. Therefore, to solve these problems there should be a new approach difference with existing one. In this research, a new algorithm for finding wheel-rail contact position, calculation method of contact force and applied force will be presented.

  • PDF

Rigid-Plastic FE Modeling of Frictional Contact Problems based on a Penalty Method (벌칙방법에 의한 마찰 접촉문제의 강소성 유한요소 모델링)

  • 장동환;황병복
    • Transactions of Materials Processing
    • /
    • v.12 no.1
    • /
    • pp.34-42
    • /
    • 2003
  • This paper presents a rigid-plastic finite element method to handle the frictional contact problem between two deformable bodies experiencing large deformation. The variational formulation combined with incremental quasi-static model is employed for treating the contact boundary condition. The frictional behavior of the model obeys Coulomb's law of friction. The proposed contact algorithms are classified into two categories, one for searching contacting nodes and the other for calculating contact forces at the contact surface. A slave node and master contact segment are defined using the geometric condition of finite elements on the contact interface. The penalty parameter is used to limit the penetration between contacting bodies, and the finite elements are coupled with contact boundary elements.us gates and cavity thicknesses. Through this study we have observed that the jetting is related to the die swell of material. This means that the jotting is strongly affected by the elastic flow property rather than the viscous flow property in viscoelastic characteristics of molten polymer. Different resins have different elastic properties, and elastic flow behavior depends on the shear rate of flow, i.e. injection speed. Large die swell would eliminate jetting however, the retardation of die swell would stimulate jetting. In the point of mole design, reducing the thickness ratio of cavity to gate can reduce or eliminate jetting regardless of amount of elasticity of polymer melt.

A Study on Curvature Determination Approach of Disk Cams Using relative Accelerations of Followers (종동절의 상대가속도를 이용한 원반 캠의 곡률반경 결정법에 관한 연구)

  • Shin, Joong-Ho;Kang, Dong-Woo;Kim, Jong-Soo;Kim, Dae-Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.8
    • /
    • pp.113-119
    • /
    • 2000
  • There are two major factors which affect the cam design : the pressure angle and the radius of curvature, Cam shape will have an instantaneous radius of curvature at every point. Even though the design constraint of the pressure angle has been satisfied the follower may still not complete the desired contact motion. If the radius of the follower roller is larger than the concave(negative) radius on the cam it occurs the gap between the cam and the follower roller at the contact point. And also if the curvature of the pitch curve of the cam is too sharp the cam profile may be undercut. This paper proposes a new approach which uses the relative velocity of the follower roller parallel to the tangent line at the contact point on the cam surface for determining the pressure angle and the relative acceeration for determining the radius of curvature.

  • PDF

Experimental study on damage and debonding of the frozen soil-concrete interface under freeze-thaw cycles

  • Liyun Tang;Yang Du;Liujun Yang;Xin Wang;Long Jin;Miaomiao Bai
    • Structural Engineering and Mechanics
    • /
    • v.86 no.5
    • /
    • pp.663-671
    • /
    • 2023
  • Freeze-thaw cycles induce strength loss at the frozen soil-concrete interface and deterioration of bonding, which causes construction engineering problems. To clarify the deterioration characteristics of the interface under the freeze-thaw cycle, a frozen soil-concrete sample was used as the research object, an interface scanning electron microscope test under the freeze-thaw cycle was carried out to identify the micro index information, and an interface shear test was carried out to explore the loss law of interface shear strength under the freeze-thaw cycle. The results showed that the integrity of the interface was destroyed, and the pore number and pore size of the interface increased significantly with the number of freeze-thaw cycles. The connection form gradually deteriorates from surface-to-surface contact to point-to-surface contact and point-to-point contact, and the interfacial shear strength decreases the most at 0-3 freeze-thaw cycles, with small decreases from to 3-8 cycles. After 12 freeze-thaw cycles, the interfacial shear strength tends to be stable, and shear the failure occurs internally in the soil.

Evaluating the Technical Efficiency of Service Operations Using DEA Models: An Application to Contact Center Services (DEA 모형에 의한 서비스 운영의 기술적 효율성 평가: 컨택센터 서비스를 중심으로)

  • Cho, Geon;Lee, Kyoung-Jae;So, Soon-Hu
    • Journal of Korean Society for Quality Management
    • /
    • v.37 no.2
    • /
    • pp.1-11
    • /
    • 2009
  • Recently, many companies have been very interested in CRM(Customer Relationship Management). Most companies have been also considering the contact center as a key CRM channel, because it is a contact point between customers and companies. It turns out that the contact center handles over 70% of all customer-company interactions and the success or failure of a company can be determined by the customer satisfaction with contact center experiences. Despite of the strategic importance of the contact center, there has been few empirical study on the efficiency of contact center operations in the literature. One of the main purposes of this study is to evaluate the efficiency of contact centers so as to not only identify the current status of contact center operations, but also suggest ways to improve operational efficiency. For this purpose, we apply a non-parametric efficiency measurement method, DEA (Data Envelopment Analysis), to 57 domestic contact centers in order to compare their relative efficiency. It is expected that the measurement methods suggested in this study can be applied to various issues such as service KS certification, outsourcing service management, and the productivity analysis of service personnel.

Reduction of Power Disturbance by Contact Loss Phenomenon of a High Speed Electric Train Using Passive Filters (수동필터를 이용한 고속전철 이선현상에 의한 전원외란 저감)

  • Chang, Chin-Young;Jin, Kang-Hwan;Kang, Jeong-Nam;Park, Dong-Kyu;Kim, Yoon-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.206-211
    • /
    • 2010
  • Since high-speed train is a dynamic load in which electric power is externally supplied, contact loss between the catenary and pantograph occurs. This phenomena including vibrations generates frequently irregular arcs, which, in turn causes EMI. Thus it is very important to develop the approach to reduce arc phenomenon by contact loss, as speed of electric railway vehicle increases. In case of an electric railway vehicle using electrical power, compared with diesel rolling stock, Power Line Disturbance(PLD) such as harmonics, transient voltage and current, Electromagnetic Interference(EMI), and dummy signal injection etc usually occur. In this study, the dynamic characteristics of a contact wire and a pantograph suppling electrical power to high-speed train are investigated with an electrical response point. To implement power line disturbance induced by contact loss phenomenon for high speed train operation, a hardware simulator which considers contact loss between contact wire and pantograph as well as contact wire deviation is developed. It is confirmed by the experiments that contact loss effect is largely dependent on voltage conditions when the contact loss occurs. Also, a passive filter is designed to reduce power disturbance and the designed system is verified by experiment.