Current Limiting Characteristics of Flux-lock Type SFCL according to Inductance Variation

  • Choi Hyo-Sang;Park Hyoung-Min;Cho Yong-Sun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권2호
    • /
    • pp.87-89
    • /
    • 2006
  • We investigated the current limiting characteristics of flux-lock type superconducting fault current limiter(SFCL) according to inductance variation of coil 2. The flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil through an iron core, and the secondary coil is connected to the superconducting element in series. The operation of the flux-lock type SFCL can be divided into the subtractive and the additive polarity winding operations according to the winding directions between the coil 1 and coil 2. The current limiting characteristics in two winding directions were dependent of on the ratio of the number of turns of coil I and coil 2. The fault current increased when the number of turns of coil 2 increased in the subtractive polarity winding. On the contrary, the fault current decreased under the same conditions in case of the additive polarity winding.

FT의 빠른 신뢰도계산을 위한 연구 (A Study on the rapid calculating of reliability for Fault Tree)

  • 이일재;이광원
    • 한국안전학회지
    • /
    • 제12권4호
    • /
    • pp.180-190
    • /
    • 1997
  • A new method in the fault tree analysis (FTA) for the reliability calculation is suggested. Two steps are necessary in traditional method in evaluation of the occurrence probability of top event in fault tree (FT). The first step is to find the minimal outsets, and the second one is to substitute the result into the poincare equation. In order to reduce the enormous computing time of this method, lots of rapid algorithms have been developed. Almost of all achievements were, however, based on the partial structural properties of FT. In this paper, the FT is transformed to a non-linear graph G which has the same minimal outsets of original n, and then the reliability is calculated using the domination theory. In this new method, the required number of equation terms are at most $2^n$ (n is node number of graph G), while $2^m$-1 (m is the number of minimal cutsets) calculation terms are required in the poincare equation in traditional method. Since m>>n in general. our new method reduces the calculation time significantly.

  • PDF

EMTP를 이용한 Hybrid Type Superconducting Fault Current Limiter (Hybrid Type Superconducting Fault Current Limiter Modeling using EMTP)

  • 박세호;이상봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.172-174
    • /
    • 2008
  • A fault current limitation using fault current limiter(FCL) is very important for power system operation. In recent year, a number of research have been performed and still Progressing about the super conducting fault current limiter(SFCL), To protect the power system effectively from the large fault current, several superconducting fault current limiters proposed. However, there are many problem such as cost, recovery and ac loss. To solve these problems, hybrid superconducting fault current limiter(HSFCL) have been proposed. In this paper, HSFCL are modeled using (Electro Magnetic Transient Program - Restructured Version) EMTP-RV.

  • PDF

배전계통에서 1선 지락고장 시험에 의한 지락고장전류 분류에 관한 연구 (A Study on the Ground Fault Current Distribution by Single Phase-to-Neutral Fault Tests in Power Distribution System)

  • 김경철;유창훈
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.37-44
    • /
    • 2013
  • Phase to ground faults are possibly one of the maximum number of faults in power distribution system. During a ground fault the maximum fault current and neutral to ground voltage will appear at the pole nearest to the fault. Distribution lines are consisted of three phase conductors, an overhead ground wire and a multigrounded neutral line. In this paper phase to neutral faults were staged at the specified concrete pole along the distribution line and measured the ground fault current distribution in the ground fault current, three poles nearest to the fault point, overhead ground wire and neutral line. A simplified equivalent circuit model for the distribution system under case study calculated by using MATLAB gives results very close to the ground fault current distribution yielded by field tests.

Fault Tree Analysis(FTA)에 의한 Toluene저장 Tank의 폭발해석 (The Evaluation of Explosion For Toluene Storage Tank by Computer-Aided Fault Tree Analysis)

  • 정재희;이영섭
    • 한국안전학회지
    • /
    • 제3권2호
    • /
    • pp.5-16
    • /
    • 1988
  • This study is conducted to evaluate the explosion of tolune storage tank in the petrochemical plant by Fault Tree Analysis. The conclusions are as follows; 1) Fault Tree diagram and the required computer program for evaluation of explosion accident is developed. 2) The probability of the top event, explosion accident, is $1.5\;{\times}\;10^{-8}$ per year, so there is almost no possibility of explosion during the life cycle of tank. However, the probability of Gate 6 and Gate 7 is 8.8 per month, therefore, attention should be paid to them for accident prevention. 3) The number of minimal cut sets is 67 sets which are not calculated the probability of each set, because of the lack of computer capacity. All the minimal cut sets should be examined case by case. However, it is necessary to be paid attention to COM1, 126, 131, and COM4 in minimal cut sets, because the number of appearance is so high. 4) The number path sets is 70 sets which are not calculated the probability of each set, because of the lack of computer capacity. It is very useful to prepare safety checklist by using this minimal path sets. Also, the events which appear many times, 123, COM5, 139, 127 and 128, are very high in reliability.

  • PDF

ANSI 규격에 의한 주상 변압기의 동압력 내력시험에 관한 연구 (The Study of the Design Tests for Current Capability according to ANSI)

  • 김선구;김원만;나대열;노창일;이동준;정흥수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.909-911
    • /
    • 2003
  • The almost pole transformers are constructed with tank, cover, clamp etc., that contains the insulation oil, core, coil, terminals, bus and the other accessories. If some fault current will be flown by some trouble or accident, interior pressure of the transformer shall be very quickly rise, and mechanical components or insulation oil from the transformer enclosure shall be propelled or dropped from the tank. For the prevention of the above accident, recently the pole transformers should be done 'the Design Tests for Fault Current Capability' according to ANSI C57.12.20(1997) There are two tests method in this standard, Test Number I with a high current arcing fault, without internal fusible elements, shall be conducted on rack enclosure with its minimum designed air space. Test Number II with an internal fusible element, shall be conducted on each enclosure diameter utilizing the internal fusible elements. KEPCO recently request to be done the 'Design Tests for Fault Current Capability' for pole transformers according to KEPCO's standard ES141-$533{\sim}545$, PS141-$482{\sim}518$ and RS141-$611{\sim}628$ that is same with Test Number I of ANSI C57.12.20.

  • PDF

양전원 송전선로의 고장점 표정 알고리즘 (Fault Location Algorithm in a Two-ended Sources Transmission Line)

  • 박철원
    • 전기학회논문지P
    • /
    • 제65권1호
    • /
    • pp.18-24
    • /
    • 2016
  • In order to service restoration and enhance power system reliability, a number of impedance based fault location algorithms have been developed for fault locating in a transmission line. This paper presents an advanced impedance-based fault location algorithms in a two-ended sources transmission line to reduce the DC offset error effects. This fault location algorithm uses of the GPS time synchronized voltage and current signals from the local and remote terminal. The algorithm uses an advanced DC offset removal filter. A series of test results using ATPdraw simulation data show the performance effectiveness of the proposed algorithm. The proposed algorithm is valid for a two-end sources transmission network.

Observer를 이용한 화학공정의 이상감지 (Fault detection of chemical process using observer scheme)

  • 최용진;오영석;윤인섭
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.589-594
    • /
    • 1993
  • This paper presents a fault detection strategy that discriminates the faulty sensor and that detects the component fault using a bank of observers for the system in which sensor fault and component fault can occur simultaneously. Observers as many as the number of measurements are designed, and each observer uses measurements excluding sequentially one measurement, to estimate the state variables. The faulty sensor can be found out by comparing each state variable from different observer. Next, component fault can be detected by using measurements from the sensors excluding the faulty sensor. The suggested strategy is applied to a nonisothermal, series reaction with unknown reaction kinetics in a CSTR. This strategy is found out to perform well even in the case that the sensor and component fault occur simultaneously. Since each observer is designed to be independent of reaction kinetics, this strategy is not affected by the model uncertainty and nonlinearity of the reaction kinetics.

  • PDF

선형회로에 있어서의 결함식별 매트릭스 (Fault Identification Matrix in Linear Networks)

  • 임광호
    • 대한전자공학회논문지
    • /
    • 제9권1호
    • /
    • pp.17-24
    • /
    • 1972
  • 단순한 외부 측정만으로써 수동 및 능동 회로망에서의 한개의 결함요소(Faulty Element)를 결정하기위해서 벡터를 이용한 한 방법을 연구했다. 큰 회로망은 몇개의 작은 회로망이 연결되었다고 생각할 수 있다. 여러 주파수에서의 전달 함수의 크기와 회로요소의 변화와의 사이에서 일어나는 관계를 이용함으로써 Fault Simulation Curve를 그릴 수 있다. 이곡선으로부터 결함식별영역(Fault Identification Region)을 정의한다. 정의된 결함식별영역에 따라 결함시별 매트릭스(Fault Irlentification Matrix)가 형성된다. 어떤 회로로부터 측정된 치를 성분으로하는 벡터를 결함식별 매트릭스에 곱해줌으로써 다른 한개의 벡터를 유도하는데 이유도된 벡터의 성분이 회로의 결함요소를 식별해주는 것이다. 결함식별방법을 위한 한 시험절차가 계시되고 실험에 의하여 입증되었다.

  • PDF

이종(異種) 오류원 기반의 현실적인 다중 오류 주입 시스템 (Realistic Multiple Fault Injection System Based on Heterogeneous Fault Sources)

  • 이종혁;한동국
    • 정보보호학회논문지
    • /
    • 제30권6호
    • /
    • pp.1247-1254
    • /
    • 2020
  • 스마트홈 시대가 도래하면서 실생활의 다양한 곳에 기밀성을 제공하거나 인증을 수행하는 장비들이 존재하게 되었다. 이에 따라 암호화 장비 및 인증 장비에 물리적인 공격으로부터의 안전성이 요구되고 있다. 특히 외부에서 인위적으로 오류를 주입하여 비밀 키를 복구하거나 인증 과정을 우회하는 오류 주입 공격은 매우 위협적인 공격 방법의 하나다. 오류 주입 공격에 사용되는 오류원은 레이저, 전자파, 전압 글리치, 클락 글리치 등이 있다. 오류 주입 공격은 오류가 주입되는 횟수에 따라 단일 오류 주입 공격과 다중 오류 주입 공격으로 분류된다. 기존의 다중 오류 주입 시스템은 일반적으로 단일 오류원을 사용하였다. 단일 오류원을 여러 차례 주입하도록 구성된 시스템은 물리적인 지연 시간이 존재한다는 점과 추가적인 장비가 필요하다는 단점이 존재한다. 본 논문에서는 이종(異種) 오류원을 사용하는 다중 오류 주입 시스템을 제안한다. 그리고 제안하는 시스템의 효용성을 보이기 위해 Riscure사의 Piñata 보드를 대상으로 다중 오류 주입 공격을 수행한 결과를 보인다.