• 제목/요약/키워드: The hearing threshold

검색결과 148건 처리시간 0.025초

휴대용 어음청력검사 시스템 구현 (Development of Ambulatory Speech Audiometric System)

  • 신승원;김경섭;이상민;임원진;이정환;김동준
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.645-654
    • /
    • 2009
  • In this study, we present an efficient ambulatory speech audiometric system to detect one's hearing problems at an earlier stage as possible without his or her visit to the audiometric testing facility such in a hospital or a clinic. To estimate a person's hearing threshold level in terms of speech sound response in his or her local environment, a digital assistant(PDA) device is used to generate the speech sound with implementing audiometric Graphic User Interface(GUI) system. Furthermore, a supra-aural earphone is used to measure a subject's hearing threshold level in terms of speech sound by the compensating the transducer's gain by adopting speech sound calibration system.

Hearing Rehabilitation with Combined Electroacoustic Stimulation and Ossiculoplasty

  • Lee, Jeon Mi;Na, Gina;Choi, Jae Young
    • 대한청각학회지
    • /
    • 제25권2호
    • /
    • pp.110-114
    • /
    • 2021
  • We report a case of hearing rehabilitation following combined cochlear implantation and ossiculoplasty. A 71-year-old patient visited the clinic for right-sided mixed hearing loss. We targeted neural and conductive components, performing two different operations simultaneously. At two months post-operative, the patient showed satisfactory results with respect to hearing threshold and speech comprehension. Our experience suggests that careful evaluation of patients and consideration of the diverse array of available treatment strategies can be used to provide personalized rehabilitation with maximal effectiveness. To the best of our knowledge, this is the first report to take such an integrated approach to treat hearing impairment and is thus likely to have clinical importance for otologists.

Hearing Rehabilitation with Combined Electroacoustic Stimulation and Ossiculoplasty

  • Lee, Jeon Mi;Na, Gina;Choi, Jae Young
    • Journal of Audiology & Otology
    • /
    • 제25권2호
    • /
    • pp.110-114
    • /
    • 2021
  • We report a case of hearing rehabilitation following combined cochlear implantation and ossiculoplasty. A 71-year-old patient visited the clinic for right-sided mixed hearing loss. We targeted neural and conductive components, performing two different operations simultaneously. At two months post-operative, the patient showed satisfactory results with respect to hearing threshold and speech comprehension. Our experience suggests that careful evaluation of patients and consideration of the diverse array of available treatment strategies can be used to provide personalized rehabilitation with maximal effectiveness. To the best of our knowledge, this is the first report to take such an integrated approach to treat hearing impairment and is thus likely to have clinical importance for otologists.

설문지를 통한 고등학생들의 MP3 사용 실태 및 청력에 미치는 영향 (Survey on the Use of MP3 Players of High School Students and the Effect to Their Hearing Thresholds)

  • 홍하나;강동호;홍빛나
    • 한국음향학회지
    • /
    • 제32권1호
    • /
    • pp.56-63
    • /
    • 2013
  • 본 논문에서는 청소년들의 MP3 사용 실태와 그에 따른 청력역치를 평가했다. 청소년들의 MP3 사용률은 지속적으로 증가하고 있으며 청력과 관련하여 위험요소가 되고 있다. 본 연구에서는 광주 지역의 2개 고등학교에 재학 중인 남녀 538명을 대상으로 MP3의 사용 실태를 조사하고 청력 역치를 측정하여 사용 유형별로 상관성을 평가했다. 분석 결과, 하루중 1시간 이상 MP3 사용률이 61.1%였으며, 주당 4일 이상 사용하는 비율이 71.6%이고, 3년 이상 사용한 경우가 36.7%로 나타났다. 조사대상의 51%가 볼륨 크기를 60%이상으로 듣고 있으며 귀 통증을 인식하고 있었다. MP3를 장시간 사용하며 소리를 크게 듣는 청소년과 그렇지 않은 청소년들의 청력은 유의한 차이가 있는 것으로 나타났다 (p< 0.0001).

Digital Hearing Aid DSP Chip Parameter Fitting Optimization

  • Jarng, Soon-Suck;Kwon, You-Jung;Lee, Je-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1820-1825
    • /
    • 2005
  • DSP chip parameters of a digital hearing aid (HA) should be optimally selected or fitted for hearing impaired persons. The more precise parameter fitting guarantees the better compensation of the hearing loss (HL). Digital HAs adopt DSP chips for more precise fitting of various HL threshold curve patterns. A specific DSP chip such as Gennum GB3211 was designed and manufactured in order to match up to about 4.7 billion different possible HL cases with combination of 7 limited parameters. This paper deals with a digital HA fitting program which is developed for optimal fitting of GB3211 DSP chip parameters. The fitting program has completed features from audiogram input to DSP chip interface. The compensation effects of the microphone and the receiver are also included. The paper shows some application examples.

  • PDF

디지털 보청기 DSP Chip 파라미터 적합 최적화 (Digital Hearing Aid DSP Chip Parameter Fitting Optimization)

  • 장순석
    • 제어로봇시스템학회논문지
    • /
    • 제12권6호
    • /
    • pp.530-538
    • /
    • 2006
  • DSP chip parameters of a digital hearing aid (HA) should be optimally selected or fitted for hearing impaired persons. The more precise parameter fitting guarantees the better compensation of the hearing loss (HL). Digital HAs adopt DSP chips for more precise fitting of various HL threshold curve patterns. A specific DSP chip such as Gennum GB3211 was designed and manufactured in order to match up to about 4.7 billion different possible HL cases with combination of 7 limited parameters. This paper deals with a digital HA fitting program which is developed for optimal fitting of GB3211 DSP chip parameters. The fitting program has completed features from audiogram input to DSP chip interface. The compensation effects of the microphone and the receiver are also included. The paper shows some application examples.

감각신경성 난청의 예후 인자에 대한 평가와 침구 치료에 대한 임상적 고찰 (The Assessments of Prognotic Factors on Sensorineural Hearing Loss And The Clinical Study with Acupuncture Treatment)

  • 문경숙;이소열;권오섭;장조웅;권혁성;윤대환
    • Korean Journal of Acupuncture
    • /
    • 제23권4호
    • /
    • pp.101-110
    • /
    • 2006
  • Objectives : The purpose of this study was clinical observation about sensorineural hearing loss compare with acupucture treatment and assessments of prognotic factors. Methods : This study was clinical observation about sensorineural hearing loss cases. for diagnosing in these cases, pure tone audiometry was used. The treatment, acupuncture was used. Results : Three patients(37.5%) remarkably improved, one patient(12.5%), slightly improved, four patients(50%), no change. Conclusions : These results suggest that the prognosis by age and initial hearing threshold was significant. The treatment on sensorineural hearing loss considered that bone condution improved.

  • PDF

소음유발 청력손실과 소음폭로에 대한 연구 (The analysis of the relation between noise induced hearing loss and noise exposure)

  • 장호경
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.217-225
    • /
    • 1998
  • 본 연구에서는 A청감보정 소음레벨과 폭로기간에 대한 소음유발 청력손실과 소음폭로 사이의 관계를 해석하였다. 연령과 소음폭로등 다양한 변수에 대하여 청력손실과 청감민감도 변화를 조사하였다. 연구결과 전체 청력손실은 음압의 시간적분에 의한 소음폭로 레벨에 비례하였다. 만약 소음폭로가 노인성 난청보다 크면 연령과 소음에 의해 발생하는 청력손실은 주된 원인이 소음에 의한 것임을 확인하였다. 과도한 소음은 일시적 청력손실의 원인이며, 폭로가 길어지거나 강력하면 영구적 청력손실의 원인이 될 수 있다. 소음유발 청력손실을 겪는 사람의 청력도는 4kHz 영역에서 청감민감도의 급격한 손실을 보여주며, 이 영역은 여러 형태의 산업소음으로 인해 가장 손상받기 쉬운 전형적인 주파수영역임을 확인하였다.

  • PDF

어음청취역치와 순음청력검사의 상관관계에 관한 연구 (The Correlation Between Speech Reception Threshold and Pure Tone Audiometry)

  • 이철희;선우대활;민양기;백만기
    • 대한기관식도과학회:학술대회논문집
    • /
    • 대한기관식도과학회 1981년도 제15차 학술대회연제순서 및 초록
    • /
    • pp.38.2-39
    • /
    • 1981
  • 어음청취역치는 어음명료도검사를 위한 기초검사이며 순음청력검사의 신뢰도를 검증하는데도 이용된다. 순음청럭검사와 어음청취역치의 연관성을 보기위해 본원에 내원한 전음성난청환자 50이(33명), 정상인 30이(40명)에 대해 Grason-Stadler 1702 Audiometer를 사용하여 순음청력검사와 어음청취역치를 측정하여 다음과 같은 결과를 얻었다. 1) 어음청취역치와 회화음역에서의 순음평균치의 차이는 전음성난청의 경우 그 범위가 -3,3dB∼+8.3dB로 평근 2.4dB의 격차를 보였고 정상인의 경우 그 범위가 -6.7dB∼+5dB로 평균 1.9dB의 격차를 보였다. 2) 회화음역의 500Hz, 1,000Hz, 2,000Hz 각 주파수에서의 역치와 어음청취역치간의 차이는 전음성난청의 경우 500Hz에서 평균 6dB, 1,000Hz에서 평균 3dB, 2,000Hz에서 평균8.8dB였으며 정상인의 경우 500Hz에사 평균 3dB, 1,000Hz에서 평균 2dB, 2,000Hz에서 평균 5dB로서 전음성난청과 정상인에서 다같이 1,000Hz에서 어음청취역치와 순음역치의 차이가 가장 적었다.

  • PDF

소음성 난청 선별검사에 HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version)의 적용 (Application of HHIE-S(Hearing Handicap Inventory for the Elderly-Screening version) to screening test of noise-induced hearing loss)

  • 이미영;서석권;이충원
    • Journal of Preventive Medicine and Public Health
    • /
    • 제29권3호
    • /
    • pp.539-553
    • /
    • 1996
  • 이 연구는 1994년도 5월부터 9월까지 동산병원 건강 관리과에서 소음특수건강진단을 받은 근로자 중 일부를 대상으로 하여 1차 선별 순음청력검사에 난청선별 설문지(HHIE-S)의 적용가능성을 점검해 보기 위하여 시행되었다. 대상자는 이 기간중의 특수검진 수진자들로서 총 6,700명 중 계통적 표본추출법에 의하여 매 5번째의 근로자가 추출되었다. 최종분석 대상은 자료가 미비한 14명을 제외한 1,019명으로 남자 488명, 여자 531명이었다. 소음성 난청의 1차 선별검사로 순음청력검사와 HHIE-S를 포함한 설문지검사를 실시하였다. 청력검사의 1차 선별기준은 양쪽 어느 귀의 청력손실이 4000Hz 에서 40dB이상인 자로 하였고 2차 정밀검사에서 난청의 기준은 3분법으로 계산하여 30dB 이상이면서 4000Hz에서 50dB 이상의 청력손실이 있는 자로 하였다. 설문지의 신뢰도는 0.84였다. 청력장애와 관련된 변수들의 단일변량분석에서 유의한 차이를 보인 항목은 남자에서 HHIE-S 총척도와 사회적/상황적 소척도에서 근무기간, 군복무력, 1000Hz 및 4000Hz에서의 청력역치였으며 여자에서 총척도와 소척도 모두에서 연령, 근무기간, 1000Hz 및 4000Hz에서의 청력역치였다. 다단계 다중회귀분적에서 남자에서 1000Hz및 4000Hz에서의 청력역치가 선택되었으며 여자에서는 총척도와 사회적/상황적 소척도에서 1000Hz 및 4000Hz에서의 청력 역치, 근무기간, 연령이 선택되었다. 2차 순음청력검사를 황금기준으로 하여 1차 선별청력검사와 HHIE-S점수를 기준으로 한 ROC곡선을 그린 결과, 최적의 타당도는 병행검사에서 HHIE-S점수 8을 기준으로 하였을 때였으며 민감도와 특이도가 각각 85%와 67%이었으며 위음성이 15%로 최소였다. 이러한 결과는 HHIE-S가 우리나라에서 신뢰도 및 타당도가 비교적 적절하며 소음성 난청 1차 선별검사에 순음청력검사와 함께 병행해서 사용하면 민감도를 높이고 위음성을 떨어뜨림으로써 순음청력검사의 병행검사로 적용가능성이 있음을 시사해 준다.

  • PDF