• 제목/요약/키워드: The han riverbed tunnel

검색결과 4건 처리시간 0.018초

한강하저터널의 쉴드TBM 적용시 디스크 커터 소모량 예측과 소모량 (Disc Cutter Consumptions Prediction on Applying Shield TBM at the Han Riverbed Tunnel)

  • 최정명;정혁상;천병식;이용주
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.562-570
    • /
    • 2010
  • This study was conducted to estimate the number of disc cutter consumption and to predict amount of disc cutters when a shield TBM(Tunnel Boring Machine) of the Han Riverbed Tunnel was applied. In fact, it is almost impossible to change the machine after starting the excavation using the shield TBM method. Therefore, it is important to design an appropriate equipment in the shield method - an efficiency choice of the operation equipment plays a key role in the shield tunnel processing. For the above reason, the disc cutter consumption prediction is quite important so that the detailed analysis is required. A number of disc cutter consumption was predicted by the three methods, viz. KOMATSU, MITSUBISHI and NTNU. In addition, the predicted results were compared with field data. The prediction of disc cutter consumption showed that 237 for KOMATSU, 501 for MITSUBISHI, and 634 for NTNU, respectively. However, a total number of 1,263 disc cutter consumption were investigated during the tunnel construction. It was found that there was a huge difference between the predicted and real values of the disc cutter consumption. The more detailed investigation showed that the disc cutter was worn out bluntly in the northbound tunnel, meanwhile it was worn out sharply in the southbound tunnel. In particular, the disc cutter consumption in the southbound tunnel was increased rapidly because of rear abrasion for remaining mucks in the chamber.

  • PDF

쉴드 TBM 성능예측모델과 굴진자료 분석을 통한 굴진성능 개선방안 (Improvement Plan of Excavation Performance Based on Shield TBM Performance Prediction Models and Field Data)

  • 정혁상;강형남;최정명;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제11권2호
    • /
    • pp.43-52
    • /
    • 2010
  • 쉴드공법은 막장을 굴착함과 동시에 원통형 강재를 지반속에 추진시켜 터널을 축조하는 공법이다. 1818년 마크 브루넬이 런던의 템즈강 하저 굴착공사에 처음 사용한 이래 지반조건에 따른 다양한 쉴드 TBM이 개발되어 도로, 지하철, 전력구, 상하수도 등에 널리 활용되고 있다. 막장상태를 수시로 관찰하며 지반변화에 빠르게 대처할 수 있는 NATM 공법과 달리, 쉴드 공법은 굴진이 시작되면 장비 교체가 거의 불가능하다. 따라서 지반조사 및 실내시험 결과에 따라 적절한 장비를 설계하고, 막장상태에 따라 압입깊이, 커터헤드 회전속도 등을 효율적으로 관리하여 장비의 성능을 최대한 활용하여 굴착공사를 수행해야 한다. 본 연구에서는 분당선 한강하저터널의 지반조건을 NTNU, $Q_{TBM}$, 합경도, KICT-SNU 등의 모델에 적용하여 굴진성능을 예측하고, 실시공 굴진자료와 비교 분석하여 예측모델의 적용성을 검토하였으며, 한강하저터널 하행선의 굴진성능 저하원인을 분석하였다.

한강 단층대를 통과하는 하저터널의 안정성 확보에 관한 연구 (Stability Evaluation for a riverbed tunnel in the Han River at the Fault Zone Crossing)

  • 우종태;이송
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권3호
    • /
    • pp.225-231
    • /
    • 2001
  • When building tunnels beneath riverbeds where very large quantities of groundwater inflow exist, added to high water head the soil supporting conditions are very poor because the soil consists of sand and silt, etc. It is necessary to have grouting and mini pipe roof installed in the region for ground reinforcement to decrease permeability. According to this result of horizontal boring and laboratory soil testing, ground reinforcement was achieved by L.W grouting for range of 3.0 times the tunnel radius, to increase stability of the tunnel we used the ling-cut method, 0.8m for one step excavation, shotcrete with 25cm thick, steel lib with H-$125{\times}125$. and a temporary shotcrete invert 20cm thick was installed to prevent deformation of the tunnel.

  • PDF

스트리머 전기비저항 탐사에 의한 하저 단층 탐지 (Delineation of a fault zone beneath a riverbed by an electrical resistivity survey using a floating streamer cable)

  • 권형석;김정호;안희윤;윤진성;김기석;정치광;이승복
    • 지구물리와물리탐사
    • /
    • 제8권1호
    • /
    • pp.50-58
    • /
    • 2005
  • 하저지반은 단층대의 분포가능성이 매우 높으나 수층으로 인해 지표지질조사가 불가능하여 단층대를 파악하기가 쉽지 않다. 하상 전기비저항 탐사는 하저지반에 대한 연속적인 영상을 제공하여 주므로 단층이나 연약대의 위치를 파악하는데 매우 효과적인 탐사법이다. 하저터널의 설계에서는 단층대의 위치뿐만 아니라 단층대의 주향방향이 매우 중요한 요소이다. 단층대의 주향방향을 파악하는 방법으로는 격자형의 측선에 대한 광대역 조사가 매우 효과적이다. 하지만. 종래의 하상 전기비저항 탐사는 케이블을 하저에 설치하여야 하므로 광대역 조사에 적합하지 않다. 이에 이 연구에서는 소형보트에 스트리머 케이블을 설치하여 신속하게 광대역의 하저지반을 영상화하는 스트리머 전기비저항 탐사의 적용성에 대해 고찰하였다. 스트리머 전기비저항 탐사에 의한 단층대의 분해능을 고찰하기 위하여, 수직단층이 수층 하부의 퇴적층에 피복되어 있는 모형을 설정하여 수치모형실험을 수행하였다. 전극의 설치위치와 수심의 변화에 따른 수직단층의 분해능에 대해 살펴보았으며, 그 결과 수층의 두께가 전극간격의 2 배 이내인 경우에는 전극을 수층 표면에 설치하는 방식으로도 단층을 영상화할 수 있음을 보였다. 또한, 스트리머 전기비저항 탐사에 적합한 4 가지의 전극배열법을 설정하여 신호대 잡음비와 수직 단층의 분해능을 비교 검토하였다. 수치모형실험을 기초로 하여 한국 서울에 위치한 한강의 하저터널 예정부지에서 하상 전기비저항 탐사를 수행하였다. 하저터널 예정노선에서는 고분해능의 영상이 요구되므로 하저에 전극을 설치하여 자료를 획득하였으며, 2차원 역산을 적용하여 강 양단에서 단층대로 추정되는 3개의 저비저항 이상대를 탐지하였다. 저비저항 이상대의 윈인을 규명하기 위하여 시추조사를 수행하였으며, 그 결과 수 m 이상의 폭을 가지는 다수의 단층이 관측되었다. 단층대의 주향방향을 탐지하기 위하여 확인된 저비저항 이상대를 중심으로 격자형의 측선을 설정하여 스트리머 전기비저항 탐사를 수행하였다. 이를 통해 하저에 케이블을 설치하는 방식에 비해 매우 신속하고 경제적으로 하저에 분포하는 이상대의 분포범위와 발달방향을 규명할 수 있었다.