• 제목/요약/키워드: The building total floor area

검색결과 82건 처리시간 0.031초

메디컬빌딩의 건축계획특성 연구 - 청주지역을 중심으로 (A Study on the Architectural Planning Characteristics of Medical Buildings - Focused on Cheong-ju Area)

  • 백상열;김기수
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제21권3호
    • /
    • pp.69-77
    • /
    • 2015
  • Purpose: Under a trend of hospitals that repeated expansion in line with fast increasing factors of medical demands in the past, medical buildings where clinic businesses have regularly gathered in one building have exponentially increased since separation of prescribing and dispensing in 2000. Thus, this study aims at analyzing characteristics of architectural plan of the current medical buildings, identifying strengths and weaknesses through Post Occupancy Evaluation and suggesting an architectural planning method of medical buildings to be planned in the future. Methods: Scope of study has been limited to 23 medical buildings that are registered in the building register as medical buildings out of the Class 1 neighborhood facilities build as 5 floors or more in Cheongju region since 2000 and being actually used for the usage. Study method is to define concepts of the medical buildings through literature review and advanced researches, analyze characteristics of architectural plan through drawing analysis and site survey. Results: General characteristics of architectural plans for the medical buildings in Cheongju have been analyzed. There are the most frequencies in general commercial area and semi-residential area, most of them are reinforced concrete structure and the Class 1 neighborhood facilities. Average land area is $482.68m^2$, gross floor area $3720.8m^2$, the number of underground floors level 1.16, the number of floors level 7.76, total number of floors 8.92, the building-to-land ratio 67.28%, floor area ratio 452.6%, height 31.44m, and the number of parked vehicles 24.16. Implications: This research will contribute to the establishment of the planning methods which increase the quality of Medical Buildings in Cheongju.

드론 활용 체적산출 자동화를 통한 해체 폐기물량 예측기법에 관한 연구 (Estimation Method of the Amount of Demolition Waste through Automated Calculation of Volumetric Spaces using Drones)

  • 류정림;김혜리;박원준
    • 한국건축시공학회지
    • /
    • 제22권6호
    • /
    • pp.681-688
    • /
    • 2022
  • 본 연구에서는 도면정보나 건축물 정보가 불확실한 노후 지역의 건설폐기물 발생량 예측을 위하여 드론촬영, 자동 체적 산출, 연면적 간접 변환, 폐기물량 예측의 과정을 QGIS 플러그인 형태로 구축하였다. 이를 위해 모의검증을 통하여 드론 활용 자동 산출된 체적과 현장실측 기반 BIM 체적과의 높은 일치성을 확인하였다. 실제 해체예정지를 대상으로 현장검증을 실시하고 드론 기반 체적과 실측-BIM기반 체적의 일치성을 재확인하였다. 층고와 건축물 유형 설정을 통하여 폐기물 발생 원단위를 적용하고 직간접적인 방식으로 폐기물량을 산출하였고, 전체 과정은 드론 촬영과 산출 자동화 과정을 포함하여 면적 1,200,000m2 대상지를 6시간 이내의 작업시간으로 신속하게 처리하였다. 비록 건축물 정보와 드론을 통한 건물 객체의 차이는 가설물, 적재물, 층고 설정에 따라 오차가 발생하였지만, 실제 해체물량도 최초 예측보다 더 크게 발생할 것으로 파악되었으며, 향후 사례조사를 통하여 체적-연면적 변환의 정확도 향상에 대한 개선이 필요할 것이다.

건물의 형상이 안전사고에 미치는 영향분석에 관한 기초연구 (A Basic Study on Analysis of the Impact of Building Shape on Safety Accidents)

  • 손승현;김지명;안성진;한범진;나영주;김태희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 봄 학술논문 발표대회
    • /
    • pp.27-28
    • /
    • 2022
  • There is a limit to preventing various types of safety accidents in advance at construction sites. Even for buildings of the same total floor area, it is expected that the more complex the building shape or the higher the number of floors, the higher the probability of a safety accident. Therefore, it is necessary to analyze the effect of the shape of a building on safety accidents using safety accident data generated during actual construction. The purpose of this study is to analyze the impact of building shape on safety accidents. As a result, the R2 value of shape factor and safety accident was 0.901, and the R2 value of construction difficulty and safety accident was 0.944. In the future, the results of this study will be used as basic data for improving safety management related systems.

  • PDF

부산시 최저고도지구 실태 및 기준조정에 관한 연구 (A Study on Present Condition and Adjustment of the Minmium Height Regulation District in Busan Metropolitan City)

  • 이동현;백태경
    • 한국지리정보학회지
    • /
    • 제11권2호
    • /
    • pp.51-60
    • /
    • 2008
  • 본 연구는 부산시의 최저고도지구의 적정성을 평가하는데 목적이 있다. 이를 위해 도심부의 최저고도지구에 대한 실태조사를 실시하였다. 조사결과, 도심부의 최저고도지구는 4층(12m)이상 건축해야 함에도 불구하고 4층 이하 건축물이 51%를 차지하였고, 평균층수도 4층이었다. 도심부의 건축물은 토지이용의 고도화와 가로경관을 위해 정책적으로 관리되고 강화되어야 할 필요가 있다. 이에 본 연구에서는 전문가 설문조사 결과 등을 토대로 전면도로폭원(35m)과 이면도로폭원(8m)의 평균을 최저도고도지구의 최저기준높이로 설정하고, 도심부에 대해서는 토지의 고도이용을 위해 최저고도지구 기준을 7층(21m) 이상 상향시킬 필요가 있다는 제안을 하였다.

  • PDF

Seismic study of buildings with viscoelastic dampers

  • Pong, W.S.;Tsai, C.S.
    • Structural Engineering and Mechanics
    • /
    • 제3권6호
    • /
    • pp.569-581
    • /
    • 1995
  • In this paper, the seismic behavior of a 10-story building equipped with viscoelastic dampers is analyzed. The effects of ambient temperature, the thickness, the total area, and the position of the viscoelastic dampers are studied. Results indicate that the energy-absorbing capacity of viscoelastic damper decreases with increasing the ambient temperature. The thickness and the total area of viscoelastic dampers also affect the seismic mitigation capacity. The thickness cannot be too small, which is not effective in vibration reduction, nor can it be too large, which not only increases the cost but also reduces the seismic resistance. The total area of viscoelastic dampers should be determined properly for optimum damper performance at the most economical design. The mounting position of viscoelastic dampers also influences the structure's seismic performance. Numerical results show that, if properly equipped, the VE dampers can reduce the structural response both floor displacement and story shear force and increase the overall level of damping in structures during earthquakes.

VAV 및 VWV시스템 적용에 따른 업무용 건축물의 에너지저감에 관한 연구 (A Study of applying VAV and VWV System to reduce Energy Consumption of Office building)

  • 송지용;홍원화;김지연;박효순
    • KIEAE Journal
    • /
    • 제13권1호
    • /
    • pp.57-63
    • /
    • 2013
  • Building Energy Efficiency Rating system was enforced in 2001 to enhance spreading high-energy performance and saving buildings. It was only for the new apartments, but expanded to new office buildings in 2010, and moreover, government offices require 1st grade of Building Energy Efficiency Rating system. Green Building Act, which is established to reduce the emissivity of carbon dioxide by reducing building energy consumption, will be enforced in 2013, and new apartments and office buildings will be subjected to it. Henceforward, it will extend to other types of buildings and will be phased in. In general, pumps and fans consume approximately half of the air-conditioning energy consumption, and about a quarter of the total building energy consumption when office buildings have total floor area of more than 10000 square meters. This study analyzed the energy demand when applying VAV(Variable Air Volume) and VWV(Variable Water Volume) System to reduce energy returns of the pumps and the fans by ECO2, which is a computer simulation program used for Building Energy Efficiency Rating system.

Raffles City in Hangzhou China -The Engineering of a 'Vertical City' of Vibrant Waves-

  • Wang, Aaron J.
    • 국제초고층학회논문집
    • /
    • 제6권1호
    • /
    • pp.33-47
    • /
    • 2017
  • This mixed-use Raffles City (RCH) development is located near the Qiantang River in Hangzhou, the capital of Zhejiang province, located southwest of Shanghai, China. The project incorporates retail, offices, housing, and hotel facilities and marks the site of a cultural landscape within the Quianjiang New Town Area. The project is composed of two 250-meter-tall twisting towers with a form of vibrant waves, along with a commercial podium and three stories of basement car parking. It reaches a height of 60 stories, presenting views both to and from the Qiantang River and West Lake areas, with a total floor area of almost 400,000 square meters. A composite moment frame plus concrete core structural system was adopted for the tower structures. Concrete filled steel tubular (CFT) columns together with steel reinforced concrete (SRC) beams form the outer moment frame of the towers' structure. The internal slabs and floor beams are of reinforced concrete. This paper presents the engineering design and construction of this highly complex project. Through comprehensive discussion and careful elaboration, some conclusions are reached, which serve as a reference guide for the design and construction of similar free-form, hybrid, mix-use buildings.

염료감응태양전지의 투과율에 따른 채광성능 및 현휘지수 분석을 통한 적정창면적비에 대한 연구 (A Study on the Optimal Window Floor Ratio Acording to Transmitance of Dye Sensitized Solar Cell(DSSC) by Analysis of Daylighting perfomance and Glare Index of Transmitance)

  • 오명환;심세라;이철성;진경일;윤종호
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.92-97
    • /
    • 2009
  • It is more necessary to consider the various factors for developmenting visible PV module of alternative window than traditional PV module. It must have sufficient performance which is Tvis, daylighting, daylight factor, glare index. so that more needs to consider suitable plan and total evaluated technology. Under the this background. For using commonly a combination BIPV module system and Daylinghting that can alternative architectural window, our goal on this study is drawing proper window area ratio as the window by analyzing lighting performance and glare index depending on transmittance of DSSC. On this study, we drew the result about window area ratio that can apply in the building when applying DSSC in the window. In situation that window is alternated as curtain wall in atrium that has big Widow area, if applying red 15.8% DSSC of low transmittance, it is expect to proper because it is suitable illumination standard and doesn't occur a discomfort glare. In case of office, we propose to apply red 33.2% or blue 35.2% DSSC of high transmittance for no affecting lighting load. we expect to contribute to select proper and effective window when applying the window in the building by drawing the window area ratio that can apply in thee building depending on transmittance of DSSC and offering the glare index data.

  • PDF

사무소용 건물의 설비유지관리 실태에 관한 조사연구 (A Study on the Actual Conditions of Maintenance for Service Facilities in Office Buildings)

  • 손장열;이승언
    • 대한설비공학회지:설비저널
    • /
    • 제14권1호
    • /
    • pp.12-20
    • /
    • 1985
  • This paper aims to present the basic data to establish resonable building maintenance standards by investigating and analyzing the actual conditions of maintenance for service facilities and the problems due to the situation. The subject buildings of investigation are 10 stories and above off ice buildings in Seoul. The results obtained from this study are as follows. 1. The equipment service life related to air-conditioning system is known as around 9years in case of breakdown maintenance and around 13 years in case of preventive maintenance. 2. The total mechanical room area against the total floor area is $4.40\%$, and the ratio of air-conditioning room area is $1.78\%$ on an average.

  • PDF

AHP를 이용한 군 취사식당 기능공간 분석 (Analyzing the Functional Spaces of Military Dining Facilities Using Analytic Hierarchy Process)

  • 이승후;이현수;박문서;지세현
    • 대한건축학회논문집:구조계
    • /
    • 제36권5호
    • /
    • pp.155-164
    • /
    • 2020
  • This research used Analytic Hierarchy Process(AHP) to analyze the importance and priority of functional space and evaluation factors of each functional space of the military dining facility. Dining in the military is an important factor in restoring combat power and promoting morale. The military dining facility serves as a not only for meals, but also for watching TV, education and club activities. Workers working in dining facility spend most of their work hours in dining facility, perform tasks such as cooking, dishwashing, and leftover disposal, and take breaks. As such, the military dining facility is a space where various functions are performed, and space planning should take into account these various functions when planning the building of the dining facility. However, the criteria for defense and military facilities, which are the basis for planning the space of military dining facility, are calculated only by simply analyzing the standard floor plan to match the size of the person-to. Therefore, when there is space to be reduced in the total area, there are side effects such as leaving visible table space without consideration for priority or functional space, unseen office space, and adjusting the entire area through reduction of the lounge. Accordingly, based on the priority of the space that the staff of the military dining facility considers important, this research aims to analyze the characteristics of each functional space through classification according to its unique function. This can be an indicator that can be used as a basis for future revision of the building floor area standards of the defense and military facilities standards, and it can improve usability with an efficient space plan that takes into account the characteristics of the Korean military and the satisfaction of its workers. Furthermore, efficient use of the defense budget through rational building plans can contribute to budget reduction.