• 제목/요약/키워드: The building total floor area

검색결과 82건 처리시간 0.031초

고강도 강관파이프 스트러트 흙막이공법 사례연구 (Case Study of Braced Wall System with High-strength Steel Pipe Strut)

  • 신재민;박현영;주진규;신윤석;김광희
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.19-20
    • /
    • 2012
  • According to develop urban area, the depth and floor area of basement tend to become deeper and larger. Excavation work for basement floor work is very important because its cost take 20% of total construction cost. Therefore, many studies of developing retaining wall system have performed for feasibility and safety in deep excavation work. In this study, new supporting system used high-strength pipe for retaining wall is introduced to reduce the construction cost and improve the safety and constructability by analyzing case study.

  • PDF

대학도서관 열람실 공간기준에 관한 연구 (Study on the Spatial Standard for Reading Rooms in University Libraries)

  • 임호균
    • 한국실내디자인학회논문집
    • /
    • 제25권5호
    • /
    • pp.140-147
    • /
    • 2016
  • This research aims to establish the size standard of university library's user space, and present the standard and method to calculate total area required in the planning of new building construction and remodeling. Nine university libraries newly constructed or remodeled since 2000 were selected among the libraries of large scale universities with more than 10,000 enrolled students as the target libraries in this research. The target libraries were classified into A group (five cases partially remodeled) and B group (four cases newly constructed or fully remodeled) on the basis of the change of times. A university library can be divided into three spaces (user space, administration space and public space). This research classified the reading room in the user space into bookshelf zone, reading zone, information/office zone and hall/other zone, and analyzed area ratio according to each zone. B group's bookshelf zone decreased 12% more than A group, and B group's reading zone increased 10% more than A group. However, there was no big change in the area ratio of information/office zone and hall/other zone. This can be interpreted that university library changes from book and archive preservation-oriented space to user-oriented space. This research presented a proper reading room area calculation method, based on the capacity of books, by reflecting such a change. Each zone's standard was set up through classification of domestic and international standards, based on which, the calculation method of university library's total floor area required was presented. The reason why there was difference in university library's total floor area required according to domestic standard and international standard was that the number of enrolled students per seat in the reading room was different. The area calculation methods presented in this research can be utilized as useful data upon planning university library construction or remodeling.

성장화재통계 기반 건축물 용도별 화재위험도에 관한 기초연구 (A Basic Study on the Fire Risk by Building Use based Growth Fire Statistics)

  • 서동구;이종호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.218-219
    • /
    • 2020
  • The risk of a fire in a building is closely related to the usage of the building. In particular, all fires that occur in a building are not risky to safety of human life, and it is associated with the combustion area and the increase of total floor area of the building. Therefore, this study focused on safety of human life in terms of the statistics of fire with considering the aspect of growing fires and analyzed the statistical data of fire for 10 years. As for the analysis on fire, the time of occurrence by usages of buildings, frequency of occurrence and the ratio of casualties etc. were analyzed. It is expected that results of this study could be used for evaluations on a variety of parts in terms of design, construction and maintenance of buildings.

  • PDF

건축물 지표면 가중평균 법정산정 자동화 알고리즘에 관한 연구 - 수치지형도 데이터를 이용한 Rhino Grasshopper 중심으로 - (A Study on the Automated Algorithm for Legal Calculation of Weighted Average of Building Surface - Based on Rhino Grasshopper Using Digital Topographic Map Data -)

  • 최세영;송석재;김용성
    • 한국BIM학회 논문집
    • /
    • 제13권2호
    • /
    • pp.1-15
    • /
    • 2023
  • Since the 1960s, the Korean Peninsula, which consists of 77.4 of the country's land and mountains, has seen a surge in demand for buildings due to population concentration due to urbanization and industrialization. Since then, the development of slopes has been inevitable due to the concentration and expansion of the city's population. When building a building on a slope, it is important to set the height of the surface. In this case, the means of regulating buildings in construction-related laws, such as the building closure ratio, floor area ratio, number of floors and total floor area of buildings, have an overall effect on buildings through the height of the surface. In the Korean Building Act, the setting of the height of the ground affects the calculation of the building height limit standard and the calculation of the underground floor, and it takes a long time to calculate. Therefore, the time required for attempts to change various design plans of buildings increases. The purpose of this study is to speed up the time required to calculate the weighted average of the surface when constructing buildings on slopes. In addition, the existing calculation process allows various design attempts compared to the same time given.

A Study on Space Program of Korean Floating Marina Clubhouse

  • Pak, Sung-Sine
    • 한국항해항만학회지
    • /
    • 제36권7호
    • /
    • pp.545-552
    • /
    • 2012
  • Domestic marina facilities today consist mostly of composite-type marinas with particular spatial composition characteristics, due to the regulatory restrictions that keep their development in the public sector and the tepid growth of marine leisure-sports. To develop a marina club design appropriate for domestic conditions, this study establishes space program standards for designing Korean marinas based on a case analysis of existing marina clubs and a survey of floating marina clubs. It is possible for a current composite-type Korean marina club to have a spatial composition of 16~18% for marina-exclusive facility (mFA), 47~49% for commercial facility (cFA), 27~30% for public space (pFA) and 5~8% for management space (emFA). With this composition as a basis, space program estimation of a Korean marina club can be done through the process of estimating in order the marina-exclusive facility area, the floor area by each space and the total floor area, the first floor area, the deck area and the pontoon area. Since the space program established in this study can be utilized as a tool for designing a Korean marina club, it is expected to be helpful in designing marina clubs in the future.

지역별 에너지 소요량과 생산량을 반영한 제로에너지건축물의 설계 방안에 관한 연구 (A Study on the Design Method of Zero Energy Building considering Energy Demand and Energy Generation by Region)

  • 이순명;이태규;김정욱
    • 대한건축학회논문집:계획계
    • /
    • 제34권8호
    • /
    • pp.13-22
    • /
    • 2018
  • The purpose of this study was to consider the energy generation of the building as well as the energy demand of the building in terms of zero energy building design. The reason why the zero energy building viewpoint should be discussed is that direction of the building, heat transfer rate of the building, and the S/V ratio of the building are variables related to energy demand and solar panels installed on the building roof and building envelope are variables related to energy generation. This study proceeded as follows; Firstly, the simulation model of large office and elementary school has the same mutual volume and total floor area, and the each floor area and number of floors are adjusted so that the S/V ratio is different. To the next, the energy demand and energy generation of the simulation model were derived based on the meteorological data of Seoul, Daejeon, Busan. Finally, energy demand, energy generation, and final energy demand were compared with heat transfer rate, S/V ratio, building type, region, and orientation. The results of this study is that consideration of solar power generation in terms of energy generation should be taken into consideration at the same time in consideration of the heat transfer rate, the shape, the region and the direction of the zero energy building design.

석면함유 공공 건축물의 위해성 평가 및 면적 분포 특성 (An Asbestos Risk Assessment and Areal Distribution of Asbestos Containing Materials in Public Buildings)

  • 송수진;장봉기;조봉현;김영지;허은협;이종대;손부순;이종화
    • 한국산업보건학회지
    • /
    • 제26권3호
    • /
    • pp.267-276
    • /
    • 2016
  • Objectives: This study, aims to examine the distribution characteristics of asbestos-containing building materials; risk assessment and area of distribution of asbestos-containing building materials depending on year of construction; building materials; types of building materials; and usage in public buildings in order to create fundamental data for safe management of public buildings. Methods: The asbestos investigation was conducted by an asbestos research institution from March to May 2014, targeting 41 public buildings which were subject to asbestos investigation in South Chungcheong-do Province. With respect to 381 presumed asbestos-containing materials, an investigation was conducted into whether they contained asbestos, asbestos type, content, year of construction, and use in the building were examined, and a risk assessment was performed. Results: Asbestos-containing building materials were used in 35 buildings(85.4%). Among them, 31(88.6%) were public buildings. Asbestos was detected in 73% of 381 suspected asbestos-containing materials, which were mostly ceiling materials (85.2%). The older the buildings, the more they showed a tendency to have a significantly higher risk assessment score. The ratio of average area with asbestos-containing building materials to total floor area was 57.6%, 44.1%, and 17.8% for buildings built in the 1980s, 1990s, and 2000s, respectively. This showed a tendency to be significantly higher with the age of the building. Conclusions: From the results above, it can be concluded that with the age of the buildings, the risk assessment score and the ratio of average area with asbestos-containing building materials to total floor area became significantly higher. Given the concern about the exposure to asbestos of residents and civil petitioners, safety management of older public buildings and measures for dismantling and removal of asbestos-containing building materials should therefore be urgently established.

복합용도지역의 건축물 규모의 운용방안에 관한 연구 (A Study on the Application building Scope for the Mixed-Use Districts)

  • 이원근;김영찬
    • 한국디지털건축인테리어학회논문집
    • /
    • 제10권1호
    • /
    • pp.65-74
    • /
    • 2010
  • This study has been given careful consideration to an induction of the mixed-use districts for the efficiency of Land Use, the rational plot planning and the mixture/complex among the functions in order to complement the zoning plan with the primary purpose to purify the usage of landscape. Furthermore, it is aimed to indicate the implementations through the medium of the in-depth analysis about the cardinal factors such as the standards on the regional location, building size and building uses in the case of designating the Mixed-use districts.Abstract This study has been examined by the aspect of scope for securing the adequacy of Site Division Restriction, Floor Area Ratio, Building Coverage Ratio and Outdoor Area Ratio in the "Mixed-Use Districts" and especially, by the medium of the in-depth analysis about the actual condition of building and outdoor space scales. It has been deduced the scale standards by using the simulation and correlation analysis among the factors of those buildings and outdoor spaces. Moreover, it has been applied the analysis method of using the building scale, especially, the latter has analyzed the total 1,656 different types classified by 3 patterns of Plottage and Building Coverage Ratio, 9 patterns of the factor change on Outdoor Area Ratio and 8 different patterns of road width.

건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구 (A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings)

  • 정영선;정해권;장희경;유기형
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.

회귀분석을 통한 창원시 중학교 전력소비량 예측에 관한 연구 (A Study on Prediction of Power Consumption Rate of Middle School Building in Changwon City by Regression Analysis)

  • 조형규;박효석;최정민;조성우
    • 교육녹색환경연구
    • /
    • 제12권2호
    • /
    • pp.61-70
    • /
    • 2013
  • As the existing school building power consumption is expressed by total power consumption, in the view of energy saving is disadvantage. The the power consumption of school building is divided as cooling, heating, lighting and others. The cooling power consumption, heating power consumption, lighting power consumption can be calculated using real total power consumption that gained from Korea Electric Power Corporation(KEPCO). The power consumption for cooling and heating can be calculated using heat transmittance, wall area and floor area, and for lighting is calculated by artificial lighting calculation. but this calculation methods is difficult for laymen. This study was carried out in order to establish the regression equation for cooling power consumption, heating power consumption, lighting power consumption and other power consumption in school building. In order to verify the validity of the regression equation, it is compared regression equation results and calculation results based on real power consumption. As the results, difference between regression result and calculation results for cooling and heating power consumption showed 0.6% and 3.6%.