• Title/Summary/Keyword: The Highest Point

Search Result 1,908, Processing Time 0.026 seconds

A Study of Solar Cell Module using Conductive Film Bonding (Conductive Film를 적용한 태양전지 모듈에 관한 연구)

  • Park, Jung-Cheul;Yang, Yeon-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.4
    • /
    • pp.250-254
    • /
    • 2016
  • In this paper, solar-cell modules were fabricated by low-temperature bonding method of construction using CF. CF adhesive strength of cells at 180 degree using 3bus bar structure was measured average 2.4N. As the bonding temperature got higher, Voc and Iscwas increased. And at $185^{\circ}C$, Rseries was measured 0.013[${\Omega}$] which is the highest point. At $185^{\circ}C$, 2N and 6sec in bonding time, $P_{max}$ was measured 3.954[W], fillfactor was measured 67.36[%] and efficiency was measured13.178[%] the highest point.

Variations of Abundance and Hatch Timing of Dungeness Crab Larvae in Southeastern Alaska: Implications for Climate Effect

  • Park, Won-Gyu;Shirley, Thomas C.
    • Animal cells and systems
    • /
    • v.12 no.4
    • /
    • pp.287-295
    • /
    • 2008
  • Variations of larval abundance and hatch timing of Dungeness crabs, Cancer magister Dana 1852, were investigated. Dungeness crab larvae were monthly collected at 16 stations arrayed in four transects, Upper Chatham, Icy Strait, Cross Sound, and Icy Point, in southeastern Alaska from May to September 1997-2004. Larval abundance at all transects was the highest in June except in the Icy Point transect. Larval abundance was the highest in the Icy Strait transect, moderate in the Upper Chatham and Cross Sound transects, and the lowest in the Icy Point transect. Zoeae I(ZI) was predominated in May; thereafter ZI decreased and late zoeal stages occurred. In May and June, small numbers of late stage larvae unusually co-occurred with ZI in three transects. These late stage larvae may have been transported from where hatching occurs earlier. The timing of ZI occurrence varied interannually and was related to degreedays during the egg incubation period of Dungeness crabs: later larval hatching in 1997 and 2002 when temperatures were colder, while earlier larval hatching in 1998 when temperatures were warmer. The distribution patterns of Dungeness crab larvae in southeastern Alaska were markedly different from those reported from other areas of the species distribution ranges: larvae occurring much later in the year, and late stage larvae occurring in inland waters.

Kinematic Analysis According to the Intentional Curve Ball at Golf Driver Swing (골프 드라이버 스윙 시 의도적인 구질 변화에 따른 운동학적 분석)

  • Hong, Soo-Young;So, Jae-Moo;Kim, Yong-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.3
    • /
    • pp.269-276
    • /
    • 2012
  • The purpose of This study's aim is to examine the difference in the changes of body segment movement, variables for ball quality, and carry at golf driver swing according to the ball quality using comparative analysis. Regarding the impact variables according to the ball quality using the track man and carry, club speed was the fastest at draw shot, ball speed was the fastest at straight shot, and smash factor was the lowest at draw shot. About the vertical launch angle, the fade shot showed the highest launch angle while the max height of the ground and ball was the highest at fade shot. And carry was the longest at draw shot. For the flight time, it was the longest at draw shot. The landing angle was the largest at fade shot. About the club head position change and trajectory, at the overall event point, the fade shot drew a more outer trajectory at the point of the follow through(E6) than the straight or draw shot. Regarding the angular speed of shoulder rotation, at the overall event point, the fade shot showed the greatest angular speed change in the follow through(E6). Also, about the angular speed of pelvic rotation, at the overall event point, the draw shot showed the greatest angular speed change at the point of down swing(E4). Concerning the stance angle change, both straight and fade shots were open as the concept of open stance whereas the draw shot was close as that of close stance. Regarding the previous study, the most important factor of deciding Ball Quality is the club face angle's open and close state at Impact. In short, the Ball Quality and carry were decided by this factor.

A Comparative Analysis of the Draping Method in Basic Bodice (베이직 바디스 입체재단법 비교 분석)

  • Kim, Young-Mi;Jang, Jeong-Ah
    • Fashion & Textile Research Journal
    • /
    • v.20 no.6
    • /
    • pp.713-721
    • /
    • 2018
  • This study aimed to develop a draping manual for the basic bodice to be available in colleges and industries. For this, draping methods mentioned in six different textbooks were comparatively analyzed. As for the research method, draping methods were compared by using training textbook, and basic bodices designed with muslin were assessed using the 5-point Likert scale. First, the draping methods of basic bodices were comparatively analyzed. The main baselines were set as the center front line, the center back line, the bust line, and the shoulder blade line. The position of dart was suggested based on the princess line, in both the front and the back. The value of dart was classified as a fixed size with any associated excess. The length of dart was set based on the bust point and shoulder blade point or a fixed size. The amount of ease was randomly set based on the fixed size, bust circumference, waist circumference, interscye length, armholes and shoulder lines, or the worker's intuition. Second, according to the appearance evaluation of the patterns, the following patterns obtained the highest scores: A pattern 2.5cm away from the B.P point of the waist dart and shoulder dart in the frontal appearance, a pattern of 0.6~0.7cm ease for the front armhole, a pattern with an ease of 1.2cm in the bust and 0.6cm in the waist. As for back appearance, the pattern in which the point of waist dart is 2~3cm from the bust line received the highest score.

A study on the Compliance and Educational Demand of Renal Transplantation Patient (신장이식 환자의 치료지시 이행정도와 교육 요구도에 관한 연구)

  • Ryu, Jeong-Ha;Kim, Myung-Hee;Kang, In-Soon
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.6 no.2
    • /
    • pp.226-238
    • /
    • 2003
  • This study was started for the purpose of providing the basic data for continous managment of kidney transplantation patients after discharge. This study was conducted on 180 patients who received renal transplants at three hospital( B, M, P) pusan, korea. The data collection was done for june 1, to August 31, 2002. General characteristics, renal transplantaton characteristics, physical characteristics, the level of compliance and the degree of educational demand were done by the number and percentage, the mean, standard deviation. The level of compliance and educational demand followed by the characteristics of general and kidney transplantation were analyzed by t-test and ANOVA. The result were as fallows; 1. Man was higher than woman such as 60.0%, Mean age was 42.5 years old, Average total duration of after operation was 5.5 years. 2. Cases of systolic blood pressure over 140mmHg were 10.0%, cases of diastolic blood pressure over 90mmHg were 22.8% and obesity factor in BMI was 15.6%. The person who daily water intake amount is 5000cc was 0.6%, the case that daily urine output is below 1000cc was 8.9%, and the case that urine output is zero was 0.6%. 3. The mean score of compliance was 77.47 point, The score in medication part was highest such as 4.67 point, that in stress situation was lowest such as 3.50 point. 4. The average score of educational demand was 154.02 point, and physical state part was 4.36 points highest, activation part was 3.48 points lowest. As a role of nurse Confirmation of compliance is very important encourage to make good through regular hospital visitation, point out the noncompliance part and then increase compliance of renal transplantation patient As well there will be maintain the normal kidney function to satisfy educational demand through continous education.

  • PDF

Comparison of Dose Depending on the Position when Shooting Panorama and CBCT (CBCT와 panorama 촬영시 위치에 따른 선량 비교)

  • Jeong, Cheonsoo;Kim, Chongyeal
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.175-179
    • /
    • 2013
  • To find out the appropriate defensive measures for protectors and radiation workers in rotating radiation generating devices such as CBCT and panorama, irradiation dose depending on the position was compared and analyzed. The devices such as panorama DP-90-P PAX-500 (Vatech, Korea) and CBCT DCT-90-P IMPLAGRAPHY Dental CT system (Vatech, Korea) were used. As irradiation dose measuring instruments, Ion chamber model 2026 and Reader 20X5-60E were used. The exposure conditions were set as the factor used in the clinical trial. The result of the experiment showed that panorama was the highest, 81${\mu}R$, at point A where the test starts first and the lowest, 53${\mu}R$, at point D where the test ends. In case of CBCT, it was the highest, 1,021${\mu}R$, at point D where the test ends and was measured as the highest, 809.67${\mu}R$, at point A where the test starts. If protectors and radiation workers are forced to examine a patient holding him, they should be positioned in the middle of the point where X ray tube starts to rotate and the point where it ends to avoid the position where radiation dose is the most. And due to the nature of equipment, it will be the safest for them to stand at the opposite side of the machine and to uphold it from the rear rather than upholding it from the side of a patient and they should wear appropriate the protection gear.

Consideration for the Highest Temperature Point Movement of the Dongrae Thermal Water in the Pusan Area. (Poster)

  • Kim Tong-Kwon;Lee Jin-Soo;Lee Seung-Gu;Song Yoon-Ho;Kim Tack-Hyun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.10a
    • /
    • pp.158-159
    • /
    • 2005
  • This study showed that the highest temperature point of the Dongrae thermal spring in Pusan was moved to the north direction of the Dongrae fault as times goes by. The Br concentration(1.5mg/L) in Dongrae thermal waters indicated the influence of 2% seawater mixing. If the simple mixing without hydrochemical reaction occurs between seawater and thermal water, the concentration of Mg will be about 20mg/L. But the low concentration(0.1 mg/L) of Mg, contrary to high concentration(10 mg/L) of surrounding groundwater not affected by thermal water, suggested the thermal water, seawater and rock interactions. The calculation of saturation index(SI) by using the geochemical code of EQ3NR showed that the Mg in thermal groundwater, which was introduced by seawater, was removed by the precipitation of Antigorite (SI: log Q/K =71.753, $Mg_{48}Si_{24}O_{85}(OH)_{62}$) and Tremolite (SI: 8.463, $Ca_2Mg_5Si_8O_{22}(OH)_2$), Talc (SI: 6.409, $Mg_3Si_4O_{10}(OH)_2$), Dolomite (SI: 2.014, $CaMg(CO_3)_2$), Chrysotile (SI: 3.698, $Mg_3Si_2O_5(OH)_4$) in the crack of fault zone. The highest temperature point in the study area will move to north direction and stop in the Jangjun area without the input of seawater.

  • PDF

Optimization of β-Glucan Extraction Process from Rice Bran and Rice Germ Using Response Surface Methodology (미강과 배아로부터 β-glucan의 추출조건 최적화 및 기능성 생리활성)

  • Jeon, Ju-Yeong;Park, Ji-Hae;Kim, Se-Hwan;Choi, Yong-Hee
    • Food Engineering Progress
    • /
    • v.13 no.1
    • /
    • pp.8-15
    • /
    • 2009
  • This study was investigated on optimal conditions of the functional activities of ${\beta}$-glucan which was extracted from rice bran (RB) and rice germ (RG) using response surface methodology. The extraction temperature was varied in the $80-100^{\circ}C$, the extraction time between 2-10 min, and the ethanol concentration was in the interval of 30-70%. A central composite design was applied to investigate the effects of independent variables of extraction temperature ($X_1$), extraction time ($X_2$) and ethanol concentration ($X_3$) on dependent variables such as electron donating ability of RB ($Y_1$), electron donating ability of RG ($Y_2$), total phenolics of RB ($Y_3$), total phenolics of RG ($Y_4$), ${\beta}$-glucan contents of RB ($Y_5$) and ${\beta}$-glucan contents of RG ($Y_6$). As a result, the highest $Y_1$ level was 84.02% at $92.60^{\circ}C$, 2.75 min and 60.41% in saddle point. This value was affected by extraction temperature (P<0.05). The value of $Y_2$ was found to be the highest at $87.52^{\circ}C$, 2.23 min and 54.40% in saddle point. The highest $Y_3$ level was $98.56^{\circ}C$, 6.69 min and 40.26% in saddle point, and this extraction was greatly influenced by extraction temperature (P<0.01) and ethanol concentration (P<0.05). The value of $Y_4$ was found to be highest at $95.73^{\circ}C$, 9.19 min and 53.67% in minimum point. The value of $Y_5$ was found to be the highest at $96.23^{\circ}C$, 7.70 min and 63.69% in saddle point. The value of $Y_6$ was found to be highest at $87.82^{\circ}C$, 2.10 min and 50.03% in minimum point, and this extraction was greatly influenced by extraction time (P<0.01).

Standardization Study of Thermal Imaging using the Acupoints in Human Body (적외선 체열 영상의 표준화 연구 부위별 대표 혈위를 중심으로)

  • Choi, Young-Chon;Lim, Chung-San;Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.11 no.3
    • /
    • pp.113-122
    • /
    • 2008
  • Objective: The purpose of this study was to invigorate the use of infrared thermal imaging apparatus as a diagnostic tool in Oriental medicine by providing standard temperature on specific acupoints. Methods: Subjects for the study was recruited through an advertisement in the school homepage(www.sangji.ac.kr) explaining the objectives and methods. 100 volunteers agreeing to terms were selected and measured the full body thermal image. Common acupoints used in the clinical surrounding were chosen and final 63 acupoints were selected for the measurement. Male/female and right/left readings were obtained for the analysis. Results: Following results were obtained from analyzing the body temperature of 50 male subjects and 50 female subjects 1. Subjects participating in the study ranged from 19 years of age to 44 years. Median male age at $26.86{\pm}6.02$ and female age at $22.88{\pm}2.74$, respectively. 2. For all acupoints, no significant differences were witnessed between the gender and right, left side of the body. 3. 10 acupoints from the facial region(18 bilateral), 8 acupoints from the chest/abdomen region(10 bilateral), 6 acupoints from the back region(11 bilateral), 17 acupoints from the upper extremity(34 bilateral), and 22 acupoints from the lower extremity(44 bilateral) were chosen. 4. In the facial region, BL2 showed the highest temperature and GV26 showed the lowest. 5. In the chest/abdomen region, CV22 showed the highest temperature and CV6 showed the lowest. 6. In the back region, GV14 showed the highest temperature and BL23 showed the lowest. 7. In the upper extremity region, jianqian(extra point) showed the highest temperature and baxie(extra point) showed the lowest. 8. In the lower extremity region, KI1 and bafeng(extra point) shoed the highest temperature and BL40 showed the lowest. Conclusions: Based on the standard body temperature measured on specific acupoints throughout the body, we hope these findings can trigger further studies on applications of infrared thermal imaging and clinical usage in the field of oriental medicine.