• Title/Summary/Keyword: The Evacuation Spaces

Search Result 58, Processing Time 0.027 seconds

Using a Spatial Databases for Indoor Location Based Services (실내위치기반서비스를 위한 공간데이터베이스 활용기법)

  • Cho, Yong-Joo;Kim, Hye-Young;Jun, Chul-Min
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.1
    • /
    • pp.157-166
    • /
    • 2009
  • There is a growing interest in ubiquitous-related research and applications. Among them, GPS-based LBS have been developed and used actively. Recently, with the increase of large size buildings and disastrous events, indoor spaces are getting attention and related research activities are being carried out. Core technologies regarding indoor applications may include 3D indoor data modeling and localization sensor techniques that can integrate with indoor data. However, these technologies have not been standardized and established enough to be applied to indoor implementation. Thus, in this paper, we propose a method to build a relatively simple 3D indoor data modeling technique that can be applied to indoor location based applications. The proposed model takes the form of 2D-based multi-layered structure and has capability for 2D and 3D visualization. We tested three prototype applications using the proposed model; CA(cellular automata)-based 3D evacuation simulation, network-based routing, and indoor moving objects tracking using a stereo camera.

  • PDF

Fire Alarm Sound Transmission in Apartment Units (공동주택에서의 화재경보음 전달)

  • Jeong, Jeong-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.67-75
    • /
    • 2018
  • To reduce the number of casualties in the case of fire, an alarm sound needs to be delivered to the people who remain in the apartment unit. On the other hand, it was reported that the fire alarm sound generated in the elevator hall was not delivered sufficiently to the people staying in the apartment units. In this study, the background noise level and noise level generated in an apartment unit were measured during the day and night time. In addition, the transmission of the fire alarm sound into the each room of apartment units was simulated and compared with the background noise level. The fire alarm sound generated in the elevator halls was reduced by the fire door and doors, and was not transmitted sufficiently into the internal spaces of the apartment units. Starting evacuation action was difficult after hearing the fire alarm sound generated outside the apartment units. To improve the transmission of an alarm sound to the inner spaces of apartment units, an acoustic simulation was carried out for cases where the alarm sound generator was installed on a wall-pad in the living room and the alarm sound generator was installed on the ceiling of each rooms in apartment units. Background noise of + 15 dB and 75 dB (A) were satisfied when alarm sound generator was installed on the ceiling of each room.

A study on the efficiency advancement for evacuation of the crews by ship structural improvement (선박 구조 개선을 통한 승무원의 피난 효율 향상을 위한 연구)

  • Kim, Wonouk;Lee, Myoungho;Kim, Jongsu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.342-348
    • /
    • 2014
  • Onshore great fires can normally be extinguished by firefighters using special firefighting equipment and its suitable method. However, offshore fires on the ships are to be extinguished by the crew without any supports from the onshore. Also, crews working on board are exposed to high risk of emergency evacuation due to the complicated structure arrangement of the ships and different accident types such as fire and ship collisions. As most of damage and loss of life in fire are associated with suffocation, shortening of evacuation time is an important factor to improve a survival rate. In this study, visibility in the accommodation area is analyzed by using the temperature and smoke flow which are obtained by the Fire Dynamic Simulator(FDS) as a Three-Dimensional Fire Analysis program to understand the survival rate of the crew upon the fire. The fire doors for most of ships are designed to close automatically when the fire alarm is activated. These automatic closing of the fire doors is a very effective system to delay the spread of flame and smoke flow for the unmanned spaces of the fire protected area. However, if the crew cannot escape within the estimated time, the crew inside the fire protected area will be damaged a lot. In this paper, the comparative analysis between the evacuations by using the fire door from the fire protected area and the suggested fire shielding structure in this study is carried out by the smoke flow rate and the temperature rise rate.

Time-Dependent Optimal Routing in Indoor Space (실내공간에서의 시간 가변적 최적경로 탐색)

  • Park, In-Hye;Lee, Ji-Yeong
    • Spatial Information Research
    • /
    • v.17 no.3
    • /
    • pp.361-370
    • /
    • 2009
  • As the increasing interests of spatial information for different application area such as disaster management, there are many researches and development of indoor spatial data models and real-time evacuation management systems. The application requires to determine and optical paths in emergency situation, to support evacuees and rescuers. The optimal path in this study is defined to guide rescuers, So, the path is from entrance to the disaster site (room), not from rooms to entrances in the building. In this study, we propose a time-dependent optimal routing algorithm to develop real-time evacuation systems. The network data that represents navigable spaces in building is used for routing the optimal path. Associated information about environment (for example, number of evacuees or rescuers, capacity of hallways and rooms, type of rooms and so on) is assigned to nodes and edges in the network. The time-dependent optimal path is defined after concerning environmental information on the positions of evacuees (for avoiding places jammed with evacuees) and rescuer at each time slot. To detect the positions of human beings in a building per time period, we use the results of evacuation simulation system to identify the movement patterns of human beings in the emergency situation. We use the simulation data of five or ten seconds time interval, to determine the optimal route for rescuers.

  • PDF

A study on the selection of the optimal smoke control mode in train platform through quantitative risk assessment (정량적 위험도 평가를 통한 열차 승강장 화재시 최적 제연모드 선정에 관한 연구)

  • Lee, Bo-Hoon;Hong, Seo-Hee;Baek, Doo-San;Lee, Ho-Hyung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.539-552
    • /
    • 2022
  • In the case of train stations, due to the specificity of underground spaces with limited smoke emissions, if appropriate removal equipment is not equipped, the damage caused by fire smoke may increase in the event of a fire. As a result, the need for measures to ensure the safety of evacuation of underground stations has been highlighted, and research for safe evacuation of platform users in case of fire is continuously being conducted at home and abroad. However, although the smoke removal area is currently divided by smoke boundary walls and platform screen doors (PSD) and installed in the train platform, standards for smoke removal methods (air supply or exhaust) for each fire removal area, that is, smoke removal mode, are not presented. In this study, fire analysis and evacuation analysis were performed to estimate the number of deaths and to derive F/N guidance in order to quantitatively evaluate the fire risk according to the fire station fire, and the total risk was the lowest in the case of fire area exhaust and supply to adjacent areas.

3D-GIS Network Modeling for Optimal Path Finding in Indoor Spaces (건물 내부공간의 최적경로 탐색을 위한 3차원 GIS 네트워크 모델링)

  • Park, In-Hye;Jun, Chul-Min;Choi, Yoon-Soo
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.3
    • /
    • pp.27-32
    • /
    • 2007
  • 3D based information is demanded increasingly as cities grow three dimensionally and buildings become large and complex. The use of 3D GIS is also getting attention as fundamental data for ubiquitous computing applications such as location-based guidance, path finding and emergency escaping. However, most 3D modeling techniques are focused on the visualization of buildings or terrains and do not have topological structures required in spatial analyses. In this paper, we introduce a method to incorporate topological relationship into 3D models by combining 2D GIS layers and 3D model. We divide indoor spaces of a 3D model into discrete objects and then define the relationship with corresponding features in 2D GIS layers through database records. We also show how to construct hallways network in the 2D-3D integrated building model. Finally, we test different cases of route finding situations inside a building such as normal origin-destination path finding and emergency evacuation.

  • PDF

Intracranial abscess from facial cellulitis

  • Park, Jonghyun;Kim, Woo Seob;Kim, Han Koo;Bae, Tae Hui
    • Archives of Craniofacial Surgery
    • /
    • v.20 no.5
    • /
    • pp.332-335
    • /
    • 2019
  • Cellulitis, one of most common diseases of everyday life, is often overlooked for its significance. Although cellulitis does not cause or lead to serious problems usually, its possibility to cause lifethreatening problem should be known. In present case, a patient who had received acupuncture treatment a week earlier presented to the clinic with symptoms of facial cellulitis. The disease resolved within few weeks under empirical antibiotic treatment but recurred after 3 months. Under close history review of the patient, we found out that the patient had received craniectomy 20 years ago. The patient had blunt headache with no other neurological symptoms that could suspect cranial infection, but considering the risk originating from the patient's surgical history, brain computed tomography (CT) was taken. CT images revealed abscess formation in the subgaleal and epidural spaces. Craniotomy with abscess evacuation was done promptly. With additional antibiotic treatment postoperatively, the disease resolved, and the 1-month postoperative followup brain CT showed no signs of abscess formation.

Conjoined Towers for Livable and Sustainable Vertical Urbanism

  • Moon, Kyoung Sun;de Oliveira Miranda, Miguel Darcy
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.4
    • /
    • pp.387-396
    • /
    • 2020
  • While tall buildings are an essential building type to accommodate an ever-growing urban population, as buildings become taller and taller, many design challenges arise. As floor spaces are repeated vertically, the occupants' natural horizontal circulation-based social interactions are limited. As buildings become ever taller, safe evacuation to the ground level becomes more challenging in emergencies. With respect to safety as well as serviceability, one of the most fundamental design challenges of exceedingly tall buildings is their structural systems that make the physical existence of tall buildings possible. While many different design solutions can be sought to resolve these issues as well as other design challenges of extremely tall buildings, this paper investigates the potential of conjoined towers to create more livable and sustainable vertical environments. Emphasis is placed on the social and structural capabilities of conjoined towers in providing enhanced social interactions and more efficient ultra-tall structures. The related brief history of conjoined towers is presented. To understand their current status, contemporary design practices of conjoined towers are discussed. Lastly, a new concept of superframed conjoined towers developed for exceedingly tall building complexes is introduced through design studies. Though envisioning future tall buildings is challenging, conjoined towers can be among the strong candidates toward more livable and sustainable vertical urbanism.

A Comparative Study on the Spatial Layout Characteristics of Modern Apartment Floor Plan and 'Standard Korea Traditional-Houses Floor Plan' (현대 아파트 평면도와 한옥표준평면도의 공간배치 특성 비교 연구)

  • Hwang, Yong-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.8
    • /
    • pp.271-278
    • /
    • 2019
  • This study compares the space depth and layout of a modern apartment floor plan (MAFP) and the standard floor plan of traditional Korean houses (STKHs), which has preserved the traditional beauty of Korea. Space Syntax was applied to compare the MAFP and STKH. The space within MAFP was more divided into many spaces than the STKH. In both types of floor plans, the living room space had the highest degree of integration and was used for central functions in the each floor plan. The STKH and the space in the MAFP have more segregated space than integrated space. In the STKH, the master bedroom and other rooms were found to be segregated space. However, the master bedroom of the MAFP was highly integrated space. The function of the thet maru has been greatly reduced in the STKH, and the numaru was classified as a highly segregated space. The evacuation space was the most segregated space in the MAFP. The STKH has been adapted and changed according to the trends of the times, and the MAFP reflects our traditional living habits.

A Study on the Development of Facility Model for Safety Training Class in School (학교 내 안전체험교실의 시설모형 개발 연구)

  • Park, Sung-Chul;Ahn, Yoo-Jeong;Song, Byung-Joon;Cho, Jin-ll
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.2
    • /
    • pp.19-33
    • /
    • 2017
  • The purpose of this study is to derive education programs for safety training class, create unit spaces and present components and methods of utilizing the spaces for the development of facilities models closely related to various policy, operation plan and facility construction projects promoted by related institutions such as the Ministry of Education, schools, architects and companies. This study is divided into five steps. First, we reviewed the literature related basic directions for safety education and facility plan, second, field survey included both field conditions such as spatial size and facility configuration and analysis of operating conditions like hours of operation and personnel. Base on literature review and field survey, it were used to analyze strengths and weaknesses of existing safety training classes, and five facility models was developed based on the Delphi method and expert participatory design. The result show that the facility models (drafts) of safety training class were developed as follows: (1)the facility model for traffic safety(pedestrian safety, vehicle safety, subway safety) (2)the facility model for first aid(emergency rescue, how to report) (3)the facility model for disaster safety(fire evacuation safety, life earthquake safety) (4)the facility model for elevator safety(elevator safety, escalator safety) (5)the facility model for drugs and violence safety (smoking drinking, sexual harassment safety, food safety) The safety training class can be composed by combining or separating each module according to affordable space size of each school.