• Title/Summary/Keyword: The Evacuation Spaces

Search Result 58, Processing Time 0.028 seconds

A Study on the Performance Criteria of Smoke Control System for Underground Spaces Through Numerical Analysis (수치해석을 통한 지하공간의 제연설비 성능기준 검토)

  • Ahn, Chan-Sol;Chae, Han-Sic;Kim, Hyeung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.356-362
    • /
    • 2008
  • This study is intended to evaluate the characteristics of smoke spreading and the appropriateness of evacuation time extended by operation of smoke control system during fire within the underground space of the building structured in compliance with the smoke control system performance criteria from the local fire safety standard in Korea. As a preceding review of this study, the combustibles was categorized and identified their heat release rates. For validate the estimated values, modeling a single underground shop was carried out. And a numerical analysis both in case of smoke control system in operation and the system not in operation was carried out of underground space. From the viewpoint of securing the evacuation time, the results were compared in an attempt to assess the appropriateness of the fire safety criteria.

  • PDF

Developing a 3D Indoor Evacuation Simulator using a Spatial DBMS (공간 DBMS를 활용한 3차원 실내 대피 경로 안내 시스템)

  • Kim, Geun-Han;Kim, Hye-Young;Jun, Chul-Min
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.4
    • /
    • pp.41-48
    • /
    • 2008
  • Currently used 3D models, which are mostly focused on visualization of 3D objects and lack topological structure, have limitation in being used for 3D spatial analyses and applications. However, implementing a full topology for the indoor spatial objects is less practical due to the increase of complexity and computation time. This study suggests an alternative method to build a 3D indoor model with less complexity using a spatial DBMS. Storing spatial and nonspatial information of indoor spaces in DB tables enables faster queries, computation and analyses. Also it is possible to display them in 2D or 3D using the queried information. This study suggests a 2D-3D hybrid data model, which combines the 2D topology constructed from CAD floor plans and stored in a spatial DBMS and the 3D visualization functionality. This study showed the process to build the proposed model in a spatial DBMS and use spatial functions and queries to visualize in 2D and 3D. And, then, as an example application, it illustrated the process to build an indoor evacuation simulator.

  • PDF

A Study on the Direction of System Improvement for the Utilization of Residential Spaces of the Emergency Evacuation Facilities in Responding to War (비상대피시설의 거주 공간 활용을 위한 제도 개선 방향 설정에 관한 연구)

  • Kim, Yujin;Hwang, Eunkyoung;Ham, Eungu
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.1
    • /
    • pp.78-86
    • /
    • 2013
  • Caused by the Cheonanham attack and the Yeonpyeongdo bombardment occurred a few years ago, and the recent North Korea's nuclear test, the war crisis between South and North Korea has been increasing. Accordingly, an interest in obtaining a temporary residential space, for the case of the outbreak of war, where people can reside safely over a period of time has been escalating. However, in the disaster relief planning guidelines of the National Emergency Management Agency, the standards on the temporary residential spaces in preparation for storm and flood or earthquake are included, but the standards on the ones in responding to war are not yet equipped. In particular, the standards on the underground temporary residential spaces that can accommodate massive victims should be developed in preparation. In this study, through a requirements analysis based on the survey of war victims and a comparative analysis between disaster-related laws and regulations, the direction of relevant system improvement for the utilization of temporary residential spaces in responding to war is established.

Implementation of EO/IR Camera for Fire-fighting of Narrow Space (협소거주공간 진화를 위한 EO/IR카메라 구현)

  • Park, Hyun-Ju
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.628-629
    • /
    • 2018
  • Recently, residential spaces in urban areas have changed into multi - family residential spaces. There is a feature that smoke is charged when a fire occurs here. Also, the evacuation route and the direction of the outflow of smoke are the same, and the possibility of inhaling the smoke of the evacuees is very high. When fighting fire in a narrow residential space such as a dwelling in a downtown area, exploration is the most important. For this purpose, we implement EO / IR sensor which can be mounted on firefighter 's helmet and can be used for fire detection. By using the EO / IR operation test, we can derive the results that can be used for research and development of the fire search sensor.

  • PDF

3D Affordance Field based Crowd Agent Behavior Simulation (3D 행동 유도장 기반 대규모 에이전트 행동 시뮬레이션)

  • Ok, Sooyol;Han, MyungWoo;Lee, Suk-Hwan
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.5
    • /
    • pp.629-641
    • /
    • 2021
  • Crowd behavior simulations have been studied to further accelerated and refined by parallelism by inducing agent-interacting forces into the image field representing the forces of attraction and repulsion. However, it was difficult to consider rapidly changing environments such as fire situations in buildings because texture images must be generated in advance simulation starts and simulations can only be performed in 2D spaces. In this paper, we propose a crowd agent behavior simulation method based on agent's 3D affordance field for flexible agent behavior in variable geomorphological environments in 3D space. The proposed method generates 3D affordance field related to agents and sensors in 3D space and defines the agent behavior in 3D space for the crowd behavior simulation based on an image-inducing field to a 3D space. Experimental results verified that our method enables the development of large-scale crowd behavior simulations that are flexible to various fire evacuation situations in 3D virtual spaces.

A Study on Smoke Extract Vents in a Subway with Screen door by Evacuation Performance Evaluation through RSET vs. ASET based on Computer Simulations (스크린도어가 설치된 지하철 승강장의 대피안전성 평가를 통한 제연환기구의 방재성능 개선방안 연구)

  • Park, Hyung-Joo;Lee, Young-Jae;Shin, Dong-Cheol;Baek, Dong-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.5
    • /
    • pp.511-519
    • /
    • 2007
  • This study provides comprehensive design improvements covering technical issues concerning life safety matter In case of fire train stoppage in the middle of a tunnel. Recently Government announced that most of subway platforms will have screen doors in 3 years. Therefore, many fire safety engineers considered that they may contribute on life safety on train stoppage in tunnel. Especially The screen door can protect platform from smoke along tunnel ceiling when fire train stopped in tunnel. The study showed that platform ventilation ducts and the a tunnel ventilation chimney in the middle of tunnel in exiting subway tunnel could not guarantee life safety ability in terms of RSET vs. ASET comparison. Furthermore during evacuation process many peoples may be threatened from the smoke spread from the origin of fire. Although only additional vertical route can be installed in tunnels In order to decrease RSET, it will costs high or no spaces remains in outside on the road. The study suggested that increase of ASET can be best solution without additional escape route, therefore alternative design methods suggested on the base of simulation results. Finally the study shows alternative methods can give good result in terms of evacuation performance evaluation. The evacuation performance evaluation helps the decision-maker to determine the preferred alternatives or upgrades to existing tunnel infrastructure and other measure to meet safety objectives. Finally, the study details the effectiveness of measures the can be taken to reduce the risk of incidents in subway tunnels.

Development of Graph based Deep Learning methods for Enhancing the Semantic Integrity of Spaces in BIM Models (BIM 모델 내 공간의 시멘틱 무결성 검증을 위한 그래프 기반 딥러닝 모델 구축에 관한 연구)

  • Lee, Wonbok;Kim, Sihyun;Yu, Youngsu;Koo, Bonsang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.3
    • /
    • pp.45-55
    • /
    • 2022
  • BIM models allow building spaces to be instantiated and recognized as unique objects independently of model elements. These instantiated spaces provide the required semantics that can be leveraged for building code checking, energy analysis, and evacuation route analysis. However, theses spaces or rooms need to be designated manually, which in practice, lead to errors and omissions. Thus, most BIM models today does not guarantee the semantic integrity of space designations, limiting their potential applicability. Recent studies have explored ways to automate space allocation in BIM models using artificial intelligence algorithms, but they are limited in their scope and relatively low classification accuracy. This study explored the use of Graph Convolutional Networks, an algorithm exclusively tailored for graph data structures. The goal was to utilize not only geometry information but also the semantic relational data between spaces and elements in the BIM model. Results of the study confirmed that the accuracy was improved by about 8% compared to algorithms that only used geometric distinctions of the individual spaces.

A Study on the fire Safety Plan in downtown underground Space (I) (도심지하공간의 화재안전계획에 관한 연구 (I))

  • Seo, Dong-Goo;Hwang, Hyun-Bae;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.348-355
    • /
    • 2008
  • In Korea, the Seoul subway line 1 was opened in 1974 and the subway service is being operated in Seoul, Pusan, Daegu, Daejeon, and Inchon. The subway station is related to a underground shopping mall that was developed as complex spaces. According to the time of people's stay at the underground space, the necessity about the safety countermeasure of the underground space has been enlarged. Therefore the result of this study is t propose guidelines for improving the evacuation safety performance in underground subway stations.

  • PDF

A Study on the Development of Performance Based Fire Risk Assesment Program (FDS를 활용한 성능위주 화재위험성평가 프로그램개발에 관한 연구)

  • Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.1-6
    • /
    • 2008
  • `SOS', Simulator Of Safety assessment for fire, was developed to simulate fire safety assessment for a structure which is geometrically complex. The program(SOS) is intended to use for searching as well as designing tools to analyse the evacuation safety through a wide range of structure conditions. The computer program has a function which importing FDS's calculating results to each individual resident in the structure. These attributes include a walking speed reduction by producing visibility reduction for each person on the fire. $A^*$ pathfinding algorithm is adopted to calculate the simulation of escape movement, overtaking, route deviation, and adjustments individual speeds in accordance with the proximity of crowd members. This SOS program contributes to a computer package that evaluates the fire safety assessment of individual occupants as they walk towards, and through the exits especially for building, underground spaces like a subway or tunnel.

A Study on the Protection of Smoke Control Performance in Building Enclosure to Prevent the Expansion of Smoke in Fire (화재시 연기확대 방지를 위한 건축물 구획공간에서의 방연성능 확보에 관한 조사 연구)

  • Jin, Seung-Hyeon;Kim, Hye-Won;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.91-92
    • /
    • 2019
  • In case of fire in a compartmentalized building area, a number of casualties are caused by smoke production. Accordingly, openings, penetrations and joints in compartmentalized spaces should be secured not only for fire resistance but also for smoke-proofing. However, domestic test regulations stipulate test methods for refractory performance of penetrations and joints, but do not specify separate deferral performance. In the case of openings, the test for the smoke performance exists at room temperature, but the smoke performance at high temperature is not secured, so countermeasures are needed.

  • PDF