• Title/Summary/Keyword: Thallium

Search Result 130, Processing Time 0.027 seconds

A Monochromatic Soft X-ray Generation from Femtosecond Laser-produced Plasma with Aluminum

  • Son, Joon-Gon;Hwang, Byung-Jun;Seo, Okkyun;Kim, Jae Myung;Noh, Do Young;Ko, Do-Kyeong
    • Journal of the Korean Physical Society
    • /
    • v.73 no.12
    • /
    • pp.1834-1839
    • /
    • 2018
  • A tabletop ultrafast soft x-ray has been generated from the laser-produce plasma with a femtosecond pulsed Ti:Sapphire laser. The estimated total flux of Al $K{\alpha}$ is of $2.2{\times}10^9photons/sec$ in $4{\pi}$ radian and the parameters related to the optical performance were obtained. The tungsten/silicon multilayer, flat quartz and bent thallium acid phthalate (TLAP) crystal were used for monochromatization of soft x-ray to refine the aluminum $K{\alpha}$ radiation and compared the respective value of $E/{\Delta}E$. To estimate the size of the x-ray source beam generated by a fs laser, the approximation using the FWHM obtained from the x-ray beam scan near the focal point was discussed, and the size of the diameter was about $9.76{\mu}m$.

Effect of Electrolyte-Additives on the Performance of Al-Air Cells (전해질 첨가제가 알루미늄-공기전지의 성능에 미치는 영향)

  • Park, Gwun Pil;Chun, Hai Soo
    • Applied Chemistry for Engineering
    • /
    • v.9 no.1
    • /
    • pp.52-57
    • /
    • 1998
  • The effects of additives such as zinc compounds in 4M KOH electrolyte of Al-air cell have been studied. Zinc compounds in electrolyte increased hydrogen evolution overpotential and TPC(tripotasium citrate)/CaO formed fine film on aluminum surface, and these additives decreased hydrogen evolution rate and corrosion rate of aluminum. These additives shifted the OCP in the positive direction on high purity aluminum(purity, 99.999%) and in the negative direction on Al No 1050(purity,99.5%). Addition of two or more additives resulted in the prevention or the reduction of corrosion rate and hydrogen evolution at OCP. As the overpotential on Al electrode increased, the hydrogen evolution rate decreased and the utilization of aluminum increased. At high current density$(>100mA/cm^2)$, TPC/CaO/ZnO additives increased the utilization of high purity aluminum up to that of aluminum alloys containing indium, gallium and thallium.

  • PDF

Isotope Measurement of Uranium at Ultratrace Levels Using Multicollector Inductively Coupled Plasma Mass Spectrometry

  • Oh, Seong-Y.;Lee, Seon-A.;Park, Jong-Ho;Lee, Myung-Ho;Song, Kyu-Seok
    • Mass Spectrometry Letters
    • /
    • v.3 no.2
    • /
    • pp.54-57
    • /
    • 2012
  • Mass spectrometric analysis was carried out using multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) for the precise and accurate determination of the isotope ratios of ultratrace levels of uranium dissolved in 3% $HNO_3$. We used the certified reference material (CRM) 112-A at a trace level of 100 pg/mL for the uranium isotopic measurement. Multiple collectors were utilized for the simultaneous measurement of uranium isotopes to reduce the signal uncertainty due to variations in the ion beam intensity over time. Mass bias correction was applied to the measured U isotopes to improve the precision and accuracy. Furthermore, elemental standard solution with certified values of platinum, iridium, gold, and thallium dissolved in 3% $HNO_3$ were analyzed to investigate the formation rates of the polyatomic ions of $Ir^{40}$ $Ar^+$, $Pt^{40}$ $Ar^+$, $Tl^{40}$ $Ar^+$, $Au^{40}$ $Ar^+$ for the concentration range of 50-400 pg/mL. Those polyatomic ions have mass-to-charge ratios in the 230-245 m/z region that it would contribute to the increase of background intensity of uranium, thorium, plutonium, and americium isotopes. The effect of the polyatomic ion interference on uranium isotope measurement has been estimated.

Development of constant current device for using in the water treatment controller with Ni-Tl-P alloy deposits (Ni-Tl-P합금피막을 이용한 수처리장치용 정전류소자의 개발)

  • Ryu, Il-Kwang
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.35-42
    • /
    • 2003
  • The electric resistance and constant current were investigated on the nickel-thallium-phosphorus alloy deposits by electroless-plating. The Ni-Tl-P alloy deposits were achieved with a bath using sodium hypophosphit as the reducing agent and sodium citrate as the comlexing agent. The basic plating solution is composed of 0.1M NiSO$_4$, 0.005${\sim}$0.0IM Tl$_2$S0$_4$, 0.1${\sim}$O.2M sodium hypophosphite and 0.02${\sim}$O.IM sodium citrate and the plating condition were pH 5${\sim}$6, temperrature 80$_4$90${\circ}$C. The results obtained are summarized as follows: 1) The crystal structure of deposit was amorphous structure as deposited state, became microcrystallized centering on Ni(111) plane by heat treatment at 200${\circ}$C, and grew as polycrystalline Ni, Ni$_3$P, Ni$_5$p$_2$,Tl, etc. by heat treatment higher than 350${\circ}$C. The grain size of plated deposits was grown up to 28.3~42.0nm by heat treatment for 1hour at 500${\circ}$C. 2) The electrical resistivity showed a comparatively high value of 192.5$_4$208.3 ${\mu}$${\Omega}$Cm and its thermal stability was great with resistivity value less than 0.22% in the thermal surroundings of 200${\circ}$C. 3) Ni-Tl-P alloy deposit showed such good constant current-making-effect in the variation of electric voltage, heat treatment temperature, and the composition of the deposit that it can be put to practical use as the matter of constant current device.

Is $^{201}Tl-^{99m}Tc$-Subtraction Scan an Accurate Diagnostic Method to Detect Parathyroid Mass? ($^{201}Tl/^{99m}Tc$ 감영스캔으로 부갑상선종괴를 얼마나 찾을 수 있는가?)

  • Yang, Hyung-In;Kim, Deog-Yoon;Kim, Kwang-Won;Choi, Young-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.31-36
    • /
    • 1994
  • We studied 65 patients with hypercalcemia who had heed performed $^{201}Tl/^{99m}Tc$ subtraction scan, 21 of them were confirmed as parathyroid tumor (19 adenoma, 2 carcinoma). The diagnostic sensitivity of $^{201}Tl/^{99m}Tc$ subfraction scan for detecting parathyroid mass was 90.5%, specificity was 97.6%, ultrasonography was 80.6%, 58.8%, respectively. The causes of two false negative cases were relatively small size ($1.5{\times}1{\times}0.8cm$) compared to remainig cases and poor thallium uptake due to cystic necrosis of parathyroid adenoma. The one false positive case was non-functioning thyroid nodule. $^{201}Tl/^{99m}Tc$ subtraction scan was simple, effective diagnostic tool and superior to ultrasonography for evaluating the parathyroid mass with high sensitivity and specificity.

  • PDF

Crystallographic analysis of dehydrated fully Tl+-exchanged zeolite Y

  • Lim, Woo Taik;Kwon, Ji Hye;Choi, Sik Young;Kim, Young Hun;Heo, Nam Ho
    • Analytical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.278-286
    • /
    • 2005
  • The crystal structure of ($Tl_{71}$-Y ($Tl_{71}Si_{121}Al_{71}O_{384}$), ${\alpha}=24.706(3){\AA}$, dehydrated at 653 K and $8{\times}10^{-6}$ torr, has been determined by single-crystal X-ray diffraction techniques in the cubic space group $Fd\bar{3}m$ at 294(1) K. The structure was refined using all intensities to the final error indices (using only the 302 reflection for which $F_{\circ}$ > $4{\sigma}(F_0)$) $R_1=0.0602$ (based on F) and $R_w=0.1744$ (based on $F_2$). The 71 $Tl^+$ ions per unit cell are found at four crystallographically distinct positions. Site I' position in the sodalite cavity opposite D6Rs are each occupied by eighteen $Tl^+$ ions per unit cell; these $Tl^+$ ions are recessed ca. $1.45{\AA}$ into the sodalite cavity from their O(3) plane (Tl-O=2.701(15), $3.163(16){\AA}$ and O-Tl-O=$92.1(4)^{\circ}$). The 23 $T1^+$ ions fill site II in the supercage; these $T1^+$ ions are recessed ca. $1.58{\AA}$ into the supercage from their O(2) plane (Tl-O = 2.850(16), $3.156(16){\AA}$ and O-T1-O = $85.1(5)^{\circ}$). The 19 $Tl^+$ ions lie at site III' in the supercage near a triple 4-ring (Tl-O = 3.10(7), $3.39(5){\AA}$ and O-Tl-O = 47.8(9), $95.3(18)^{\circ}$) and the remaining II ions occupy another site III' near a triple 4-ring in the supercage (Tl-O = 2.81(4), $2.71(4){\AA}$ and O-Tl-O = $57.3(8)^{\circ}$).

Determination of Heavy metals on the non-woven in wet wipes using ICP-MS

  • Choi, Sung-Min;Song, Jin-Kun;Kim, Sang-Jin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.195-203
    • /
    • 2016
  • Heavy metals have been analyzed on the non-woven from the 24 kinds of wet wipes and 8 kinds of mask packs. The following materials used in the non-woven according to each product are: rayon+polyester for the 12 wet wipe products, rayon+PET for the 5 wet wipe products, and rayon, cotton, rayon+polyester+cotton, pulp+polypropylene for the rest of the wet wipe products. No further information on the materials was found on the 3 wet wipes and 8 mask packs. However, polyester may be applied for the non-woven in wet wipes, because PET is part of the polyester group. The heavy metals analysis in the 24 kinds of wet wipes and 8 kinds of mask packs revealed the following: arsenic was found from $47.14{\pm}1.13$ to $71.75{\pm}1.64{\mu}g/L$ on the 3 products, the amount of nickel in the 2 products were $261.26{\pm}5.14$ and $1,242.63{\pm}43.71{\mu}g/L$, $53.69{\pm}1.45$ and $103.52{\pm}2.02mg/L$ on the 2 mask packs. It was also revealed that lead was detected from $7.23{\pm}0.32$ to $55.67{\pm}1.46{\mu}g/L$ on the 6 wet wipes, antimony was ranged from $187.86{\pm}5.24$ to $19,558.35{\pm}3,537.30{\mu}g/L$ on the 12 wet wipes, and $5.25{\pm}0.25$ and $8,936{\pm}55.22{\mu}g/L$ on the 2 mask packs. No cadmium, mercury, or thallium were detected from all the products. A high concentration of antimony might come from antimony trioxide, which was used as a catalyst when manufacturing the polyester. Therefore, it is strongly recommended that a non-woven used for cosmetic purposes should not use heavy metals as a catalyst when manufacturing, and it's important to clarify which materials are used in non-woven.

Two Crystal Structures of Ag+-and TI+-Exchanged Zeolite X, Ag27TI65-X and Ag23TI69-X

  • Kim, Soo-Yeon;Choi, Eun-Young;Kim, Yang
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.12
    • /
    • pp.1759-1764
    • /
    • 2002
  • Two crystal structures of dehydrated $Ag^+-andTl^+$-exchanged zeolite X$Ag_{27}Tl_{65-}X\;and\;Ag_{23}Tl_{69-}X$have been determined by single-crystal X-ray diffraction techniques in the cubic space group Fd3 at 21(1) $^{\circ}C(a=24.758(4)\AAa=24.947(4)$, ${\AA}respectively).$, Their structures were refined to the final error indices $R_1$=0.055 and $wR_2$=0.057 with 375 reflections, and $R_1$=0.057 and $wR_2$=0.057 with 235 reflections, respectively, for which I > $3\sigma(I).$ In the structure of $Ag_{27}Tl_{65-}X,\;27\;Ag^+$ ions were found at two crystallographic sites: 15$Ag^+$ ions at site I at the center of the hexagonal prism and the remaining 12$Ag^+$ ions at site II' in the sodalite cavity. Sixty-five $Tl^+$ ions were located at three crystallographic sites: 20$Tl^+$ ions at site II opposite single six-rings in the supercage, 18$Tl^+$ ions at site I' in the sodalite cavity opposite the D6Rs, and the remaining 27$Tl^+$ ions at site III' in the supercage. In the structure of $Ag_{23}Tl_{69-}X$, 23$Ag^+$ ions were found at two crystallographic sites: 15 at site I and 8 at site II'. Sixty-nine $Tl^+$ ions are found at four crystallographic sites: 24 at site II, 17 at stie I', and the remaining 28 at two III' sites with occupancies of 22 and 6.

A TiO2-Coated Reflective Layer Enhances the Sensitivity of a CsI:Tl Scintillator for X-ray Imaging Sensors

  • Kim, Youngju;Kim, Byoungwook;Kwon, Youngman;Kim, Jongyul;Kim, MyungSoo;Cho, Gyuseong;Jun, Hong Young;Thap, Tharoeun;Lee, Jinseok;Yoon, Kwon-Ha
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.256-260
    • /
    • 2014
  • Columnar-structured cesium iodide (CsI) scintillators doped with thallium (Tl) are frequently used as x-ray converters in medical and industrial imaging. In this study we investigated the imaging characteristics of CsI:Tl films with various reflective layers-aluminum (Al), chromium (Cr), and titanium dioxide ($TiO_2$) powder-coated on glass substrates. We used two effusion-cell sources in a thermal evaporator system to fabricate CsI:Tl films on substrates. The scintillators were observed via scanning electron microscopy (SEM), and scintillation characteristics were evaluated on the basis of the emission spectrum, light output, light response to x-ray dose, modulation transfer function (MTF), and x-ray images. Compared to control films without a reflective layer, CsI:Tl films with reflective layers showed better sensitivity and light collection efficiency, and the film with a $TiO_2$ reflective layer showed the best properties.

Efficient design of a ∅2×2 inch NaI(Tl) scintillation detector coupled with a SiPM in an aquatic environment

  • Kim, Junhyeok;Park, Kyeongjin;Hwang, Jisung;Kim, Hojik;Kim, Jinhwan;Kim, Hyunduk;Jung, Sung-Hee;Kim, Youngsug;Cho, Gyuseong
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.1091-1097
    • /
    • 2019
  • After the Fukushima accident in 2011, there has been increased public concern about radioactive contamination of water resources through fallout in neighboring countries. However, there is still no available initial response system that can promptly detect radionuclides. The purpose of this research is to develop the most efficient gamma spectrometer to monitor radionuclides in an aquatic environment. We chose a thallium-doped sodium iodide (NaI(Tl)) scintillator readout with a silicon photo multiplier (SiPM) due to its compactness and low operating voltage. Three types of a scintillation detector were tested. One was composed of a scintillator and a photomultiplier tube (PMT) as a reference; another system consisted of a scintillator and an array of SiPMs with a light guide; and the other was a scintillator directly coupled with an array of SiPMs. Among the SiPM-based detectors, the direct coupling system showed the best energy resolution at all energy peaks. It achieved 9.76% energy resolution for a 662 keV gamma ray. Through additional experiments and a simulation, we proved that the light guide degraded energy resolution with increasing statistical uncertainty. The results indicated that the SiPM-based scintillation detector with no light guide is the most efficient design for monitoring radionuclides in an aquatic environment.