• Title/Summary/Keyword: Tex Visualization

Search Result 747, Processing Time 0.031 seconds

Clinical Review of Pediatric Adenoviral Lower Respiratory Infection (아데노바이러스에 의한 소아 하기도 감염에 대한 임상적 고찰)

  • Son, Jin-A;Lee, Sang-Il;Lee, Nam-Young;Kim, Jung-Hee
    • Pediatric Infection and Vaccine
    • /
    • v.3 no.2
    • /
    • pp.154-162
    • /
    • 1996
  • Purpose : Adenoviruses(Ad) have been shown to play an important role in the etiology of severely acute respiratory diseases, particulary in infants and young children, and the occurrence of fatal outcome and chronic pulmonary sequelae in association with adenoviral infection has been a cause of great interest and concern. This report presents the resul of a retrospective analysis on 30 cases of lower respiratory infection from which adenovirus was isolated. Patients & Methods : The 30 patients in this study represent all detected cases of adenovial infection out of 240 children who were admitted to Sang Sung Medical Center between February to June 1996 showing signs and symptoms of lower respiratory tract infection. The diagnosis of adenovirus infection was based on microscopic visualization of typical cytopathic effect in HEp-2 tissue culture and used monoclonal Ab with nasopharyngeal aspiration. Results : The male/female ratio was 2:1 and the majority of age range was below 36months. Clinical diagnoses in all 30 patients were pneumonia(n=21), bronchitis and Bronchiolitis(n=5) and ARDS(n=4). We recieved the most of patients in the month of May. The chief complaints were fever(93.3%) and cough(80%) and extrapulmonary symptoms were diarrhea(n=5), seizure(n=4), abdominal pain(n=1). The mean duration of fever was $11.95{\pm}6.54$days. Physical examination on admission were crackles(73.3%), coarse breathing sounds(60%), hepatosplenomegaly(33.3%), decreased brething sounds(30%). In WBC counts, 8cases were below $4000/mm^3$ and 14 cases were above $10,000/mm^3$. In platelets counts, 4cases were below $150,000/mm^3$ and 10 cases were above $450,000/mm^3$. 21 cases were above 1 in CRP. GOT and GPT were abnormal in some cases. Chest X-ray revealed diffuse pulmonary infiltration(n=15), pleural effusion(n=6), consolidation(n=4) and hyperaeration(n=3). Seven patients were treated at the peditric intensive care unit with respiratory support and high dose of gammaglobulin. However, one patients died even through he was treated with NO ventilation and high frequency ventilation. Conclusion : Those with adenoviral pneumonia and respiratory infection having long fever duration and symptoms like bacterial pneumonia must be carefully differentiated in order to provide proper treatement and preventive measures due to possible fatal outcome.

  • PDF

A Reduction Method of Over-Segmented Regions at Image Segmentation based on Homogeneity Threshold (동질성 문턱 값 기반 영상분할에서 과분할 영역 축소 방법)

  • Han, Gi-Tae
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.1 no.1
    • /
    • pp.55-68
    • /
    • 2012
  • In this paper, we propose a novel method to solve the problem of excessive segmentation out of the method of segmenting regions from an image using Homogeneity Threshold($H_T$). The algorithm of the previous image segmentation based on $H_T$ was carried out region growth by using only the center pixel of selected window. Therefore it was caused resulting in excessive segmented regions. However, before carrying region growth, the proposed method first of all finds out whether the selected window is homogeneity or not. Subsequently, if the selected window is homogeneity it carries out region growth using the total pixels of selected window. But if the selected window is not homogeneity, it carries out region growth using only the center pixel of selected window. So, the method can reduce remarkably the number of excessive segmented regions of image segmentation based on $H_T$. In order to show the validity of the proposed method, we carried out multiple experiments to compare the proposed method with previous method in same environment and conditions. As the results, the proposed method can reduce the number of segmented regions above 40% and doesn't make any difference in the quality of visual image when we compare with previous method. Especially, when we compare the image united with regions of descending order by size of segmented regions in experimentation with the previous method, even though the united image has regions more than 1,000, we can't recognize what the image means. However, in the proposed method, even though image is united by segmented regions less than 10, we can recognize what the image is. For these reason, we expect that the proposed method will be utilized in various fields, such as the extraction of objects, the retrieval of informations from the image, research for anatomy, biology, image visualization, and animation and so on.

A Study on the natural Convection and Radiation in a Rectangular Enclosure with Ceiling Vent (천장개구부를 갖는 정사각형 밀폐공간내의 자연대류-복사 열전달에 관한 연구)

  • Park Chan-kuk;Chu Byeong-gil;Kim chol;Jung Jai-hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.1
    • /
    • pp.28-39
    • /
    • 1998
  • This study investigated the natural convection and radiation in a rectangular enclosure with ceiling vent experimentally and numerically. A heat source is located on the center of the bottom surface. The analysis was peformed a pure convection and is combination of natural convection and radiation. The shape of the considered two dimensional model is a square whose center of ceiling($30\%$) is opened. The numerical simulations are carried out for the pure natural convection case and the combined heat transfer case by using the SIMPLE algorithm. For the turbulent flow, Reynolds stresses are closed by the standard $k-{\epsilon}$ model and the wall function is used to determine the wall boundary conditions. The experiment was performed on the same geometrical shape as the computations. The radiative heat transfer is analized by the S-N discrete ordinates method. The results of pure natural convection are compared with those of combined heat transfer by the velocity vectors, stream lines, isothermal lines. The results obtained are as follows 1. Comparing the results of pure convection with those of the combined convection-radiation through the shape of stream lines, isothermal lines are similar to each other. 2. The temperature fields obtained by numerical method are compared to those obtained by experimental one, and it is found that they are showed mean relative error $8.5\%$. 3. Visualization bt smoke is similar to computational results.

  • PDF

An Experimental Study on the Effect of Capillary Pressure on the Void Formation in Resin Transfer Molding Process (수지이동 성형공정에서 기공형성에 미치는 모세관압의 영향에 관한 실험적 연구)

  • 이종훈;김세훈;김성우;이기준
    • The Korean Journal of Rheology
    • /
    • v.10 no.4
    • /
    • pp.185-194
    • /
    • 1998
  • Flow-induced voids during resin impregnation and poor fiber wetting give serious effects on the mechanical properties of composites in resin transfer molding process. In order to better understand the characteristics of resin flow and to investigate the mechanism of void formation, flow visualization experiment for the resin impregnation was carried out on plain weaving glass fiber mats using silicon oils with various viscosity values. The permeability and the capillary pressure for the fiber mats of different porosities were obtained by measuring the penetration length of the resin with time and with various injection pressure. At low porosity and low operating pressure, the capillary pressure played a significant role in impregnation process. Video-assisted microscopy was used in taking the magnified photograph of the flow front of the resin to investigate the effect of the capillary pressure on the void formation. The results showed that the voids were formed easily when the capillary pressure was relatively high. No voids were detected above the critical capillary number of 2.75$\times$$10^{-3}, and below the critical number the void content increased exponentially with decrease of the capillary number. The content of void formed was independent of the viscosity of the resin. For a given capillary number, the void content reduced with the lower porosity of the fiber mat.

  • PDF

Contrast Enhanced Cerebral MR Venography: Comparison between Arterial and Venous Triggering Methods (조영 증강 자기공명정맥 촬영술에서의 동맥과 정맥 triggering 방법의 비교)

  • Jang, Min-Ji;Choi, Hyun-Seok;Jung, So-Lyung;Ahn, Kook-Jin;Kim, Bum-Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.152-158
    • /
    • 2012
  • Purpose : To compare the arterial and venous detection sites of triggering methods in contrast-enhanced-MR-venography (CE-MRV) for the evaluation of intracranial venous system. Materials and Methods: 41 healthy patients underwent CE-MRV with autotriggering at either the cavernous segment of internal carotid artery with an inserted time-delay of 6 seconds (n = 20) or the superior sagittal sinus without any timedelay (n = 21). 0.1 mmol/kg gadolinium-based contrast material ($Magnevist^{(R)}$, Schering, Germany) was intravenously injected by hand injection. A sagittal fast-spoiled-gradient-echo-sequence ranging from one ear to the other was performed (TR/TE5.2/1.5, Matrix $310{\times}310$, 124 sections in the 15-cm-thick volume). 17 predefined venous structures were evaluated on all venograms by two neuroradiologists and defined as completely visible, partially visible, or none visible. Results: The rate of completely visible structures were 272 out of 323 (84%) in the arterial triggering CE-MRV and 310 out of 340 (91%) in the venous triggering CE-MRV. The venous triggering CE-MRV demonstrated an overall superior visualization of the cerebral veins than the arterial triggering CE-MRV (Fisher exact test, p < 0.006). Conclusion: CE-MRV using venous autotriggering method provides higher-quality images of the intracranial venous structures compared to that of arterial.

Efficient Triplet-triplet Annihilation-based Upconversion in Vegetable Oils (식물성 오일에서 구현되는 삼중항-삼중항 소멸법에 의한 Upconversion 분석)

  • Shin, Sung Ju;Choe, Hyun Seok;Park, Eun-Kyoung;Kyu, Hyun;Han, Sangil;Kim, Jae Hyuk
    • Applied Chemistry for Engineering
    • /
    • v.27 no.6
    • /
    • pp.639-645
    • /
    • 2016
  • We herein report efficient triplet-triplet annihilation upconversion (TTA-UC) achieved in various non-toxic and non-volatile vegetable oils as a UC media using platinum-octaethylporphyrin (PtOEP) and 9,10-diphenylanthracene (DPA) as a sensitizer and acceptor, respectively. Green-to-blue UC was readily achieved from PtOEP/DPA solution in vegetable oils with the quantum yield of 8% without any deoxygenation process. The UC efficiency was found to be significantly dependent on the contents of unsaturated hydrocarbon in vegetable oils and viscosity of the solution, as well. Though the Stern-volmer constant and quantum yield in vegetable oils were measured to be lower than those measured in the deaerated organic solvent, the quenching efficiency was still high enough to be 93%. In the sunflower oil, the UC threshold intensity ($I_{th}$) was approx. $100mW/cm^2$, which is far larger than the sunlight intensity, but we believe that the UC achieved in non-toxic and air-saturated media was still highly applicable to nontraditional visualization techniques such as bioimaging.

A 3-D finite element analysis on the mandibular movement pattern and stress distribution during symphyseal widening (하악 이부확장 시 하악골 이동 양상과 응력 분포에 관한 삼차원 유한요소법적 연구)

  • Lee, Do-Hoon;Hong, Hyun-Sil;Chae, Jong-Moon;Jo, Jin-Hyung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.38 no.1
    • /
    • pp.13-30
    • /
    • 2008
  • Objective: The objective of this study was to evaluate the displacement pattern and the stress distribution of the finite element model 3-D visualization during symphyseal widening according to the osteotomy position, osteotomy type, and distraction device. Methods: The kinds of distraction devices used were tooth-borne type, hybrid type, bone-borne type and tooth-borne type $30^{\circ}$ angulated, and the kinds of osteotomy design were vertical osteotomy line between the central incisors and step osteotomy line through the symphysis. Results: All reference points of the mandible including the condyles were displaced laterally irrespective of the osteotomy position, osteotomy method and distraction device. The anteroposterior or vertical displacements showed small differences between the groups. The widening pattern of the osteotomy line in the tooth-borne type of device was v shaped, and that of bone-borne type was a reverse v shape. However, the pattern in the hybrid type was parallel. The lateral displacement of the mandibular angle by the bone-borne device was more remarkable than the other types of devices. The displacement by the $30^{\circ}$ angulated tooth-borne type was different between the left and right sides in both the transverse and anteroposterior aspects. Conclusion: The design of the distraction devices and osteotomy line can influence the displacement pattern and the stress distribution during mandibular symphyseal distraction osteogenesis procedures.

Online Signature Verification by Visualization of Dynamic Characteristics using New Pattern Transform Technique (동적 특성의 시각화를 수행하는 새로운 패턴변환 기법에 의한 온라인 서명인식 기술)

  • Chi Suyoung;Lee Jaeyeon;Oh Weongeun;Kim Changhun
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.7
    • /
    • pp.663-673
    • /
    • 2005
  • An analysis model for the dynamics information of two-dimensional time-series patterns is described. In the proposed model, two novel transforms that visualize the dynamic characteristics are proposed. The first transform, referred to as speed equalization, reproduces a time-series pattern assuming a constant linear velocity to effectively model the temporal characteristics of the signing process. The second transform, referred to as velocity transform, maps the signal onto a horizontal vs. vertical velocity plane where the variation oi the velocities over time is represented as a visible shape. With the transforms, the dynamic characteristics in the original signing process are reflected in the shape of the transformed patterns. An analysis in the context of these shapes then naturally results in an effective analysis of the dynamic characteristics. The proposed transform technique is applied to an online signature verification problem for evaluation. Experimenting on a large signature database, the performance evaluated in EER(Equal Error Rate) was improved to 1.17$\%$ compared to 1.93$\%$ of the traditional signature verification algorithm in which no transformed patterns are utilized. In the case of skilled forgery experiments, the improvement was more outstanding; it was demonstrated that the parameter set extracted from the transformed patterns was more discriminative in rejecting forgeries

Forehead Osteoma Excision by Anterior Hairline Incision with Subcutaneous Dissection

  • Kim, Jun Sik;Lee, Jeong Hwan;Kim, Nam Gyun;Lee, Kyung Suk
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.1
    • /
    • pp.39-42
    • /
    • 2016
  • Forehead osteomas are benign but can pose aesthetic and functional problems. These osteomas are resected via bicoronal or endoscopic approach. However, large osteomas cannot be removed via endoscopic approach, and bicoronal approach can result in damage to the supraorbital nerve with resultant numbness in the forehead. We present a new approach to resection of forehead osteomas, with access provided by an anterior hairline incision and subcutaneous dissection. Three patients underwent resection of the forehead osteoma through an anterior hairline incision. The dissection was carried in the subcutaneous plane, and the frontalis muscle and periosteum were divided parallel to the course of supraorbital nerve. The resulting bony defect was re-contoured using $Medpor^{(R)}$. All three patients recovered without any postoperative infection or complication and symptoms. Scalp sensory was preserved. Aesthetic outcomes were satisfactory. Patients remain free of recurrence for 12 months of follow up. The anterior hair line approach with subcutaneous dissection is an effective method for removal of forehead osteoma, since it offers broad visualization and hides the scar in the hairline. In addition, the dissection in the subcutaneous plane avoids inadvertent injury to the deep nerve branches and helps to maintains scalp sensation.

Micro-imaging techniques for evaluation of plastic microfluidic chip

  • Kim, Jung-Kyung;Hyunwoo Bang;Lee, Yongku;Chanil Chung;Yoo, Jung-Yul;Yang, Sang-Sik;Kim, Jin-Seung;Park, Sekwang;Chang, Jun-Keun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.239-247
    • /
    • 2001
  • The Fluorescence-Activated Cell Sorter (FACS) is a well-established instrument used for identifying, enumerating, classifying and sorting cells by their physical and optical characteristics. For a miniaturized FACS device, a disposable plastic microchip has been developed which has a hydrodynamic focusing chamber using soft lithography. As the characteristics of the spatially confined sample stream have an effect on sample throughput, detection efficiency, and the accuracy of cell sorting, systematic fluid dynamic studies are required. Flow visualization is conducted with a laser scanning confocal microscopy (LSCM), and three-dimensional flow structure of the focused sample stream is reconstructed from 2D slices acquired at $1\mutextrm{m}$ intervals in depth. It was observed that the flow structure in the focusing chamber is skewed by unsymmetrical velocity profile arising from trapezoidal cross section of the microchannel. For a quantitative analysis of a microscopic flow structure, Confocal Micro-PIV system has been developed to evaluate the accelerated flow field in the focusing chamber. This study proposes a method which defines the depth of the measurement volume using a detection pinhole. The trajectories of red blood cells (RBCs) and their interactions with surrounding flow field in the squeezed sample stream are evaluated to find optimal shape of the focusing chamber and fluid manipulation scheme for stable cell transporting, efficient detection, and sorting

  • PDF