• Title/Summary/Keyword: Tex Visualization

Search Result 747, Processing Time 0.028 seconds

Visualizing multidimensional data in multiple groups (다그룹 다차원 데이터의 시각화)

  • Huh, Myung-Hoe
    • The Korean Journal of Applied Statistics
    • /
    • v.30 no.1
    • /
    • pp.83-93
    • /
    • 2017
  • A typical approach to visualizing k (${\geq}2$)-group multidimensional data is to use Fisher's canonical discriminant analysis (CDA). CDA finds the best low-dimensional subspace that accommodates k group centroids in the Mahalanobis space. This paper proposes an alternative visualization procedure functioning in the Euclidean space, which finds the primary dimension with maximum discrimination of k group centroids and the secondary dimension with maximum dispersion of all observational units. This hybrid procedure is especially useful when the number of groups k is two.

A Study about Vortex Flow Characteristics on Delta wing by Wime-Resolving PIV (시간해상도 PIV를 이용한 델타형 날개에서의 와류유동특성에 관한 연구)

  • Lee Hyun;Kim Beom-Seok;Sohn Myong-Hwan;Lee Young-Ho
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.105-108
    • /
    • 2002
  • Highly swept leading edge extension(LEX) applied to delta wings has greatly improved the subsonic maneuverability of contemporary fighters. In this study, systematic approach by PIV experimental method within a circulating water channel was adopted to study the fundamental characteristics of induced vortex generation, development and its breakdown appearing on a delta wing model with or without LEX in terms of four angles of attack$(15^{\circ},\;20^{\circ},\;25^{\circ},\;30^{\circ})$ and six measuring sections$(30\%,\;40\%,\;50\%,\;60\%,\;70\%,\;80\%)$ of chord length. Distributions of time-averaged velocity vectors and vorticities over the delta wing model were compared along the chord length direction. High-speed CCD camera which made it possible to acquire serial images is able to get the detailed information about the flow characteristics occurred on the delta wing. Especially quantitative comparison of the maximum vorticity featuring the induced pressure distribution were also conducted to clarity the significance of the LEX existence.

  • PDF

Spray Characteristics of the APU fuel injector with liquid properties (액체 물성치에 따른 APU 연료 노즐의 분무특성)

  • Choi, Chea-Hong;Jun, Yong-Min;Choi, Seong-Man
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.175-178
    • /
    • 2008
  • Spray characteristics for the simplex atomizer are investigated. The atomizer was tested with kerosene which is generally used as a fuel for gas turbine engines. But it is very difficult and dangerous to measure spray performance. So water is used as a working fluid for measuring the droplet information. In this study, spray visualization was performed by using ND-Yag Laser and droplet size was measured by using PDPA system by using two different working fluid such as water and test fluid # 2 which has similar characteristics of the kerosene. The test results show that SMD of water bigger than test fluid # 2 about 5$\sim$15 mm because surface tension of water is higher by a factor of 3. But the spray angles and the spray shapes have similarity

  • PDF

Performance Test for a Horizontal Regenerative Evaporative Cooler (수평형 재생증발식 냉방기의 성능시험)

  • Song, Gwi-Eun;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.621-626
    • /
    • 2006
  • Regenerative evaporative cooling is known as an environment-friendly and energy efficient cooling method. A regenerative evaporative cooler (REC) consisting of dry and wet channels is able to cool down the air stream below the inlet wet-bulb temperature. In the regenerative evaporative cooler, the cooling effect is achieved by redirecting a portion of the air flown out of the dry channel into the wet channel and spraying water onto the redirected air. In this study, a horizontal regenerative cooler is considered. In the horizontal regenerative cooler, the flow direction of evaporating water has a right angle to the flow direction of supply air. This difference was investigated with visualization technique and simplified 2-module performance test was done in a thermo-environment chamber. Optimum design configuration is changed due to the wet channel which are easily fully covered with evaporating water and block the air flow inside the channel. Applying the optimized fin configuration design with the highly wetting surface treatment, a regenerative evaporative cooler was fabricated and tested to Identify the cooling performance improvement and operation characteristics. From the experimental results at the intake condition of $32^{\circ}C$ and 50% RH, the supply temperature was measured to be around $23.4^{\circ}C$. The cooling effectiveness based on the inlet dewpoint temperature was evaluated 73% which is almost close to the design expectation.

  • PDF

Analysis of Protein Patterns of Cellular and Fluidal Components in the Porcine Follicular Contents (돼지 난포내 세포 및 난포액 구성분의 단백질상 분석)

  • 변태호;이중한;박성은;이상호
    • Korean Journal of Animal Reproduction
    • /
    • v.16 no.4
    • /
    • pp.289-299
    • /
    • 1993
  • The polypeptide patterns of cellular and follicular components were analysed by SDS-PAGE and two dimensional(2-D)electrophoresis combined with isoelectric focusing (IEF) to establish protein profiles in each of the components in porcine follicles. Oocyte-cumulus complexes were cultured in M16+FCS+Gn at 39 in an atmosphere of 5% CO$_2$, in air for 35 h. At the end of the culture, the zona-free oocyte, ZP alone and cumulus cells were prepared and analysed either on 10% SDS-PAGE for the protein profile at the first dimensional gel or 2-D protein pattern. The amounts of each samples were determined for the visualization with Coomasie brilliant blue (CBB) or silver staining, thus giving useful information for the identification of specific proteins in the components or appropriate amount of samples for proper visualization. Oocyte showed 25 and 114 kd major protein band. Other minor components were additionally visualized with CBB on the same gel after silver staining procedure. Cumulus cells also showed specific proteins which is not present in the oocytes. The number of cumulus cell was proper to give major bands with CBB and additional minor bands with silver staining. To establish the degree of contamination from the remnant of the corona radiata to the ZP, zonae were differently prepared or analysed by SDS-PAGE.The preparation of the ZP in this study did not showed any contamination judged by the protein profile of the components. Also follicular fluid showed its specific protein profile without any significant differences among the different sizes of follicles. The established protein profile of each follicular component should be helpful for the identification and elimination of contaminated components, i. e., antigen preparation or immunological studies. The results also suggest that the preparation of each components in the study was appropriate and can be used for a further sensitive biochemical analysis in mammalian oocytes and early embryos.

  • PDF

Flame Interaction with Shear Layer Flow in the Post Chamber of Hybrid Rocket (하이브리드 로켓 후연소실 전단유동과 연소반응의 상호 간섭)

  • Moon, Young Joo;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.7
    • /
    • pp.585-592
    • /
    • 2016
  • Visualization was done by using $CH^*$ chemiluminescence images and PMT measurements in order to understand the origin of fluctuating pressure and chemical luminosity at about 500 Hz frequency even in stable combustion, which was observed in recent experimental tests, and to find the physical correlation leading to Low Frequency Instability(LFI) in terms of phase angle. In stable combustion, chemical reactions are distributed along the shear layer flow showing a negative coupling(about 180 degree in phase angle) with combustion pressure. However, phase difference is shifted to a positive coupling showing less than 90 degree in unstable case. Also a periodic change in the distribution of chemical reactions is observed along with local flame extinction and the appearance of big scale vortex flow. In the transition to LFI, local flame extinction and small vortex flow start to appear in a row. As seen in the bluff body wake in reactive flow, the periodic appearance of vortex flow seems to share the same physical process of BVK(Bernard Von Karman) instability generation. Thus, the appearance of local extinction in 500 Hz fluctuations is gradually amplified to complete extinctions of about 20 Hz, and it leads into LFI.

Measurements on Transient Mixing Concentrations of Two Fuel Oils using a Quantitative Flow Visualization Technique (정량적 유동가시화 기술을 이용한 이종연료유 과도 혼합 농도분포 측정)

  • Yum, Joo-Ho;Doh, Deog-Hee;Cho, Gyeong-Rae;Min, Seong-Ki;Kim, Myung-Ho;Ryu, Gyong-Won
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.4
    • /
    • pp.364-372
    • /
    • 2012
  • Transient mixing states of two different fuel oils, dimethylformamide (DMF) oil and JetA1 oil, were investigated by using a color image processing and a neural network. A tank ($D{\times}H$, $310{\times}370mm$) was filled with JetA1 oil. The DMF oil was filled at a top tank, and was mixed with the JetA1 oil in the tank mixing tank via a sudden opening which was performed by nitrogen gas with 1.9 bar. An impeller was rotated with 700 rpm for mixing enhancements of the two fuel oils. To visualize the mixing state of the DMF oil with the JetA1 oil, the DMF oil was coated with Rhodamine B whose color was red. A LCD monitor was used for uniform illumination. The color changes of the DMF oil were captured by a camcoder and the images were transferred to a host computer for quantifying the information of color changes. The color images of two mixed oils were captured with the camcoder. The R, G, B color information of the captured images was used to quantify the concentration of the DMF oil. To quantify the concentration of the DMF oil in the JetA1 oil, a calibration of color-to-concentration was carried out before the main experiment was done. Transient mixing states of DMF oil with the JetA1 oil since after the sudden infiltration were quantified and characterized with the constructed visualization technique.

Comparison of Visualization Enhancement Techniques for Himawari-8 / AHI-based True Color Image Production (Himawari-8/AHI 기반 True color 영상 생산을 위한 시각화 향상 기법 비교 연구)

  • Han, Hyeon-Gyeong;Lee, Kyeong-Sang;Choi, Sungwon;Seo, Minji;Jin, Donghyun;Seong, Noh-hun;Jung, Daeseong;Kim, Honghee;Han, Kyung-Soo
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.3
    • /
    • pp.483-489
    • /
    • 2019
  • True color images display colors similar to natural colors. This has the advantage that it is possible to monitor rapidly the complex earth atmosphere phenomenon and the change of the surface type. Currently, various organizations are producing true color images. In Korea, it is necessary to produce true color images by replacing generations with next generation weather satellites. Therefore, in this study, visual enhancement for true color image production was performed using Top of Atmosphere (TOA) data of Advanced Himawari Imager (AHI) sensor mounted on Himawari-8 satellite. In order to improve the visualization, we performed two methods of Nonlinear enhancement and Histogram equalization. As a result, Histogram equalization showed a strong bluish image in the region over $70^{\circ}$ Solar Zenith Angle (SZA) compared to the Nonlinear enhancement and nonlinear enhancement technique showed a reddish vegetation area.

Experimental Study on Flow Structure of Wake Behind a Rotationally Oscillating Circular Cylinder (주기적으로 회전진동하는 원주 후류의 유동구조에 관한 실험적 연구)

  • Lee Jung-Yeop;Lee Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.4 s.247
    • /
    • pp.298-305
    • /
    • 2006
  • The flow around a circular cylinder which oscillates rotationally with a relatively high forcing frequency has been investigated experimentally using flow visualization and hot-wire measurements. Dominant parameters are Reynolds number (Re), oscillation amplitude $({\theta}_A)$, and frequency ratio $F_R=f_f/f_n$, where $f_f$ is the forcing frequency and $f_n$ is the natural frequency of vortex shedding. Experiments were carried out under the conditions of $Re=4.14{\times}10^3,\;{\theta}_A={\pi}/6$, and $0{\leq}F_R{\leq}2$. The effect of frequency ratio $F_R$ on the flow structure of wake was evaluated by measuring wake velocity profile and spectral analysis of hot-wire signal. Depending on the frequency ratio $F_R$, the cylinder wake has 5 different flow regimes. The vortex formation length and vortex shedding frequency are changed significantly before and after the lock-on regime. The drag coefficient was reduced under the condition of $F_R<1.0$ and the maximum drag reduction is about 33% at $F_R=0.8$. However, the drag is increased as $F_R$ increases beyond $F_R=1.0$. This active flow control method can be effective in aerodynamic applications, if the forcing parameters are selected optimally.

Estimation of Aerosol Vertical Profile from the MODIS Aerosol Optical Thickness and Surface Visibility Data (MODIS 에어러솔 광학두께와 지상에서 관측된 시정거리를 이용한 대기 에어러솔 연직분포 산출)

  • Lee, Kwon-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.16 no.2
    • /
    • pp.141-151
    • /
    • 2013
  • This study presents a modeling of aerosol extinction vertical profiles in Korea by using the Moderate Resolution Imaging Spectro-radiometer(MODIS) derived aerosol optical thickness(AOT) and ground based visibility observation data. The method uses a series of physical equations for the derivation of aerosol scale height and vertical profiles from MODIS AOT and surface visibility data. The modelled results under the standard atmospheric condition showed small differences with the standard aerosol vertical profile used in the radiative transfer model. Model derived aerosol scale heights for two cases of clean(${\tau}_{MODIS}=0.12{\pm}0.07$, visibility=$21.13{\pm}3.31km$) and hazy atmosphere(${\tau}_{MODIS}=1.71{\pm}0.85$, visibility=$13.33{\pm}5.66km$) are $0.63{\pm}0.33km$ and $1.71{\pm}0.84km$. Based on these results, aerosol extinction profiles can be estimated and the results are transformed into the KML code for visualization of dataset. This has implications for atmospheric environmental monitoring and environmental policies for the future.