• 제목/요약/키워드: Tetrabromophenolphthalein ethyl ester

검색결과 2건 처리시간 0.017초

전기전도성 고분자 위에 고정된 압타머에 흡착된 테트라브롬페놀프탈레인 에틸 에스테르를 이용한 트롬빈 검출 (Thrombin Detection with Tetrabromophenolphthalein Ethyl Ester Adsorbed on Aptamer-attached Conductive Polymer)

  • 정새로미;노희복;심윤보
    • 전기화학회지
    • /
    • 제19권4호
    • /
    • pp.134-140
    • /
    • 2016
  • 새로운 산화환원 표지자를 이용한 압타머 기반의 전기화학적 트롬빈 검출 바이오 센서를 개발하였다. 1차 지방족 아민(primary aliphatic amine) 으로 개질한 압타머를 전기 전도성 고분자 poly-(5,2':5',2"-terthiophene-3'-carboxylic acid) (polyTTCA) 층 위에 공유결합을 통해 고정하여 센서 표면을 개질하였다. Tetrabromophenolphthalein ethyl ester (KTBPE)를 압타머와 상호 작용시켜 전기화학적인 산화환원 표지자로 사용하였다. 압타머로 개질한 층 위에 KTBPE의 산화반응을 differential pulse voltammetry (DPV)를 사용하여 조사하였으며, 최종 센서의 특성은 voltammetry, QCM, and ESCA 를 사용하여 조사하였다. KTBEF와 압타머 센서와 반응 후, KTBPE의 산화 피크는 감소하였다. 센서의 선형 동적 범위는 10.0 ~ 100.0 nM 이었으며, 이 때 검출 한계는 $1.0{\pm}0.2nM$이었다.

A Simple Device of the Dry Tetrabromophenolphthalein Ethyl Ester Reagent Strip for the Detection of Methamphetamine

  • Choi, Myung-Ja;Song, Eun-Young;Kim, Seung-Ki;Choi, Jeong-Eun;Lho, Dong-Seok;Park, Jong-Sei
    • Archives of Pharmacal Research
    • /
    • 제16권3호
    • /
    • pp.227-230
    • /
    • 1993
  • A new device to detect methamphetamine (MA), amphetamine(A) and its metabolites in urine was developed using the paper strip method and the test tube method of dry chemical reagents. The reagent containing tetrabromophenolphthalein ethyl ester (TBPE) and borax. For the TBPE paper strip method, a device was prepared with a window at each end of the reagent paper strip ; one window is for the sample application, and the other window is for the methylene chloride. The diffused sample from one window reacts with reagent in the paper and produces color at the point where it meets with methylene chloride which has diffused form the other side. A positive smaple produces as red-purple color and the negative sample a greenish color, with a detection limit of 5-10 ppm. The result can be obtained within one minute. For the TBPE test tube method which contains dry reagents, the detection limit is 5 ppm and the result can be obtaineed within 30 seconds, however the carry-on is not as convenient as the paper strip method. The performance of both methods were evlauated by comparing with the results of gas chromatography (GC) and fluorescence polarizaiton immunoassay (FPIA). The results were proven that both methods were useful as primary screening reagents to detect MA in urine and in dry powder.

  • PDF