• Title/Summary/Keyword: Testing Environments

Search Result 364, Processing Time 0.034 seconds

The Software Reliability Growth Models for Software Life-Cycle Based on NHPP

  • Nam, Kyung-H.;Kim, Do-Hoon
    • 응용통계연구
    • /
    • 제23권3호
    • /
    • pp.573-584
    • /
    • 2010
  • This paper considers the differences in the software execution environments in the testing phase and the operational phase to determine the optimal release time and warranty period of software systems. We formulate equations for the total expected software cost until the end of the software life cycle based on the NHPP. In addition, we derive the optimal release time that minimizes the total expected software cost for an imperfect debugging software reliability model. Finally, we analyze the sensitivity of the optimal testing and maintenance design related to variation of the cost model parameters based on the fault data observed in the actual testing process, and discuss the quantitative properties of the proposed model.

ANSI/AMCA 210 기준에 의한 대형 축류 송풍기의 성능시험 및 측정 불확도 평가 (An Estimation of Performance Test and Uncertainty of Measurement for a Large Axial-flow Fan Based on ANSI/AMCA 210 Standard)

  • 고희환;정철영;김경엽
    • 한국유체기계학회 논문집
    • /
    • 제17권2호
    • /
    • pp.24-29
    • /
    • 2014
  • In general, a large-capacity axial flow fan is used for industrial processes or ventilation in a social overhead capital infrastructure. The main characteristics of the large axial-flow fan need a lot of electrical power consumption and operate 24 hours a day, 365 days a year. Since the large axial flow fan consumes several hundreds to thousands kW per hour, both manufacturer and consumer are struggling to select high efficiency products for saving energy and reducing operation cost. Therefore, the performance testing should be accurately conducted in experimental equipments. The performance estimation and uncertainty of measurement of the axial-flow fan gathered from the result from nozzle shaped testing equipments certified with ANSI/AMCA standard and duct shaped testing equipment under the same experimental condition. The experimental results from both facilities have maximum 17% differences in performance evaluation and uncertainty of measurement. As considering that the differences, it is doubt about the reliability of testing result. The test was repeated with the specific term during 12 months because it is important to fully reflect the real conditions and to decide the repeatability of data. The evaluation of duct type testing facilities was failed to get an uncertainty measure. Testing results were previously published. As a series of previous paper, axial fan (∅1690 mm) and duct type testing facilities were fabricated. The purpose of fabricating testing equipment was testing an uncertainty measurement under the controlled environments.

Application of Digital Signal Analysis Technique to Enhance the Quality of Tracer Gas Measurements in IAQ Model Tests

  • Lee, Hee-Kwan;Awbi, Hazim B.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제23권E2호
    • /
    • pp.66-73
    • /
    • 2007
  • The introduction of tracer gas techniques to ventilation studies in indoor environments provides valuable information that used to be unattainable from conventional testing environments. Data acquisition systems (DASs) containing analogue-to-digital (A/D) converters are usually used to function the key role that records signals to storage in digital format. In the testing process, there exist a number of components in the measuring equipment which may produce system-based inference to the monitored results. These unwanted fluctuations may cause significant error in data analysis, especially when non-linear algorithms are involved. In this study, a pre-processor is developed and applied to separate the unwanted fluctuations (noise or interference) in raw measurements and to reduce the uncertainty in the measurement. Moving average, notch filter, FIR (Finite Impulse Response) filters, and IIR (Infinite Impulse Response) filters are designed and applied to collect the desired information from the raw measurements. Tracer gas concentrations are monitored during leakage and ventilation tests in the model test room. The signal analysis functions are introduced to carry out the digital signal processing (DSP) work. Overall the FIR filters process the $CO_2$ measurement properly for ventilation rate and mean age of air calculations. It is found that, the Kaiser filter was the most applicable digital filter for pre-processing the tracer gas measurements. Although the IIR filters help to reduce the random noise in the data, they cause considerable changes to the filtered data, which is not desirable.

NCW환경에서 지휘통제체계(C4I) 상호운용성 시험평가체계 개선방안 연구 (A Study on Improvement Method of Interoperability Test & Evaluation Approach for the C4I Systems in NCW Environment)

  • 김경희;강석중
    • 한국군사과학기술학회지
    • /
    • 제15권6호
    • /
    • pp.786-801
    • /
    • 2012
  • The most essential ROC(requirement operational capability) in order to assure the effectiveness of the C4I Systems in NCW Environments is the seamless and stable interoperability between systems. The U.S. Armed Forces that perceived the importance of interoperability, prepared the framework to apply from the proposal of requirement to every step of acquisition process. The Korea Joint Chiefs of Staff is also developing a similar system in order to assure the interoperability between command control(C4I) systems. In the paper, we specify the needs of standardization of test systems and international trends on the technology, and propose an interoperability test & evaluation system based on a standardization conformity method to improve the interoperability test & evaluation for the C4I systems in NCW environments. Finally we show an example of the implementation of the test system and its application to C4I systems to verify the proposed test system.

Evaluation of cryogenic tensile properties of composite materials fabricated by fused deposition modeling 3D printer

  • Kang, Singil;Cha, Hojun;Ryu, Seungcheol;Kim, Kiwhan;Jeon, Seungmin;Lee, Jaesun;Kim, Seokho
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권1호
    • /
    • pp.8-12
    • /
    • 2022
  • Recently, research on applying composite materials to various industrial fields is being actively conducted. In particular, composite materials fabricated by Fused Deposition Modeling 3D printers have more advantages than existing materials as they have fewer restrictions on manufacturing shape, reduce the time required, weight. With these advantages, it is possible to consider utilizing composite materials in cryogenic environments such as the application of liquid oxygen and liquid hydrogen, which are mainly used in an aerospace and mobility. However, FDM composite materials are not verified in cryogenic environments less than 150K. This study evaluates the characteristics of composite materials such as tensile strength and strain using a UTM (Universal Testing Machine). The specimen is immersed in liquid nitrogen (77 K) to cool down during the test. The specimen is fabricated using 3D print, and can be manufactured by stacking reinforced fibers such as carbon fiber, fiber glass, and aramid fiber (Kevlar) with base material (Onyx). For the experimental method and specimen shape, international standards ASTM D638 and ASTM D3039 for tensile testing of composite materials were referenced.

지게차 주행 환경에 따른 드라이브 엑슬 부품의 피로 및 가혹도 분석 (Fatigue and Severity Analysis of Drive Axle Parts According to Forklift Driving Environmet)

  • 유영준;안영철;이광희;박정현;이대엽;이철희
    • 드라이브 ㆍ 컨트롤
    • /
    • 제20권2호
    • /
    • pp.24-30
    • /
    • 2023
  • This study aimed to analyze the fatigue of forklifts in industrial settings by assessing their stress levels during operation. Strain gauges were affixed to the dynamic components of the forklifts to gather real-time data and enhance the reliability of the analysis. Although monitoring structural loads in harsh testing environments can be challenging, the affixed strain gauges on the dynamic components can provide more precise results and improve the interpretation of data. By creating testing modes that simulate forklift usage environments and performing experiments with selected cargo and driving modes, a comparison of the damage severity of forklift parts under different driving conditions was done. These results can be utilized to forecast the lifespan of forklift parts under extreme driving conditions and assist in the design and optimization of new parts in the future.

모의 실험주택 모니터링 결과를 활용한 실내공기 및 바닥먼지 중 Di(2-ethyl-hexyl) phthalate (DEHP)의 이론적 총량 비율 산출 (Calculation of the Theoretical Total Amount Ratio of Di(2-ethyl-hexyl) Phthalate in Indoor Air and Floor Dust in a Test House)

  • 천사호;이가원;김승중;정승표;강다영;김기태
    • 한국환경보건학회지
    • /
    • 제49권6호
    • /
    • pp.324-333
    • /
    • 2023
  • Background: Human exposure to phthalates in indoor environments occurs via dermal absorption, oral ingestion of indoor dust, and inhalation of indoor air. However, systematic studies to investigate the exposure rate to phthalates among the three exposure routes in indoor environments are currently limited. Objectives: A theoretical exposure ratio between inhalation and oral exposure was calculated based on the total amount of di(2-ethyl-hexyl) phthalate (DEHP) emitted into indoor air and deposited into floor dust in a test house. Methods: Flooring and wallpaper containing DEHP were installed in a test house and the concentration of DEHP in both indoor air and floor dust were monitored for five months. Based on the measured DEHP concentrations, the theoretical total amount ratio of DEHP that could be exposed through inhalation and oral ingestion was calculated. Results: Considering the period of operation in the test house, the theoretical total amount of DEHP through inhalation and oral ingestion exposures in the entire test house space was calculated to be 0.014 mg and 5.5 mg, respectively. The exposure ratio of the two routes between inhalation and oral exposure corresponding to the total DEHP amount in flooring and wallpaper was 6.0×10-7% and 2.3×10-4%, indicating that theoretical oral exposure to DEHP is approximately 380 times higher than inhalation. Conclusions: Monitoring results from a test house has shown that oral exposure is the main exposure route for DEHP in indoor environments. The experimental design employed in this study and theoretical exposure ratio obtained can be applied to investigate actual exposure to DEHP and to determine the exposure characteristics of various types of semi-volatile organic compounds.

황산 환경에서 Fe-Si, Ni-Ti계 및 Ni 합금의 내부식성 특성 (Corrosion Characteristics of Fe-Si, Ni-Ti and Ni Alloy in Sulfuric Acid Environments)

  • 권혁철;김동진;김홍표;박지연;홍성덕
    • 한국재료학회지
    • /
    • 제21권1호
    • /
    • pp.1-7
    • /
    • 2011
  • Methods of producing hydrogen include steam reforming, electrochemical decomposition of water, and the SI process. Among these methods, the Sulfur iodine process is one of the most promising processes for hydrogen production. The thermochemical sulfur-iodine (SI) process uses heat from a high-temperature-gas nuclear reactor to produce $H_2$ gas; this process is known for its production of clean energy as it does not emit $CO_2$ from water. But the SI-process takes place in an extremely corrosive environment for the materials. To endure SI environments, the materials for the SI environment will have to have strong corrosion resistance. This work studies the corrosion resistances of the Fe-Si, Ni-Ti and Ni Alloys, which are tested in SI-process environments. Among the SI-process environments, the conditions of boiling sulfuric acid and decomposed sulfuric acid are selected in this study. Before testing in boiling sulfuric acid environments, the specimens of Fe-4.5Si, Fe-6Si, Ni-4.5Si, Ni-Ti-Si-Nb and Ni-Ti-Si-Nb-B are previously given heat treatment at $1000^{\circ}C$ for 48 hrs. The reason for this heat treatment is that those specimens have a passive film on the surface. The specimens are immersed for 3~14 days in 98wt% boiling sulfuric acid. Corrosion rates are measured by using the weight change after immersion. The corrosion rates of the Fe-6Si and Ni-Ti-Si-Nb-B are found to decrease as the time passes. The corrosion rates of Fe-6si and Ni-Ti-Si-Nb-B are measured at 0.056 mm/yr and 0.16 mm/yr, respectively. Hastelloy-X, Alloy 617, Alloy 800H and Haynes 230 are tested in the decomposed sulfuric acid for one day. Alloy 800H was found to show the best corrosion resistance among the materials. The corrosion rate of Alloy 800H is measured at -0.35 mm/yr. In these results, the corrosion resistance of materials depends on the stability of the oxide film formed on the surface. After testing in boiling sulfuric acid and in decomposed sulfuric acid environments, the surfaces and compositions of specimens are analyzed by SEM and EDX.

Radiation tolerance of a small COTS single board computer for mobile robots

  • West, Andrew;Knapp, Jordan;Lennox, Barry;Walters, Steve;Watts, Stephen
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2198-2203
    • /
    • 2022
  • As robotics become more sophisticated, there are a growing number of generic systems being used for routine tasks in nuclear environments to reduce risk to radiation workers. The nuclear sector has called for more commercial-off-the-shelf (COTS) devices and components to be used in preference to nuclear specific hardware, enabling robotic operations to become more affordable, reliable, and abundant. To ensure reliable operation in nuclear environments, particularly in high-gamma facilities, it is important to quantify the tolerance of electronic systems to ionizing radiation. To deliver their full potential to end-users, mobile robots require sophisticated autonomous behaviors and sensing, which requires significant computational power. A popular choice of computing system, used in low-cost mobile robots for nuclear environments, is the UP Core single board computer. This work presents estimates of the total ionizing dose that the UP Core running the Robot Operating System (ROS) can withstand, through gamma irradiation testing using a Co-60 source. The units were found to fail on average after 111.1 ± 5.5 Gy, due to faults in the on-board power management circuitry. Its small size and reasonable radiation tolerance make it a suitable candidate for robots in nuclear environments, with scope to use shielding to enhance operational lifetime.

0.5wt% 탄소강을 이용한 해안 야외부식시험과 염수분무시험, 가속부식시험의 가속계수에 대한 연구 (The Study on the Acceleration Factor of Coastal Outdoor Corrosion test, Salt Spray Test and Accelerated Corrosion Test using 0.5wt% carbon steel)

  • 조의열;권기봉;조대형;김종렬
    • Corrosion Science and Technology
    • /
    • 제12권5호
    • /
    • pp.209-214
    • /
    • 2013
  • In the industry, accelerated corrosion test is used for the life time prediction. When anti-corrosion test proceeds in real environments, it is difficult that we predict and evaluate the corrosion life time because of the long test time such as 10 years or more time. Accelerated corrosion test and Salt spray test are able to test corrosion life time of products in the laboratory instead of outdoor corrosion test. Experimental procedure is selected for the corrosion standard specimen, exposure of the specimens, measurements of the mass loss and evaluating the mass loss data. As a result, the acceleration factor of the accelerated corrosion test to the outdoor corrosion test is 414.8. Therefore we can predict the corrosion life time of carbon steel during a short time period.