• Title/Summary/Keyword: Testing Environments

Search Result 364, Processing Time 0.025 seconds

A Method for Efficient Structure Management and Evaluation of Website (웹사이트의 효율적인 구조 관리와 평가 방법)

  • 유대승;엄정섭;이명재
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2002.06a
    • /
    • pp.306-315
    • /
    • 2002
  • With the rapid growth of WWW, the existing systems are integrated into web and various web-based systems are developed. Unlike the general applications, web aplications are developed by combining the various technologies and have their own complexities. So, we have much difficulties in the development and maintenance of web applications. To accommodate to the rapidly changing business environments and user requirements, the continuos evolution is required. In this paper, we present a method for supporting the effective development and maintenance of web applications. Our method involves the extraction of web application's structure information and analyzes web log ales containing the useful information about web site. We also describe a web testing method using the attracted information and our system developed for extracting hyperlink information and analyzing web log.

  • PDF

Effects of Testing and Storage Environments on the Blood Glucose Measurements by Using Phosphazene Diagnostic Membranes (측정환경과 보관환경이 포스파젠 진단막을 이용한 혈당측정에 미치는 영향)

  • Kwon, Suk-Ky
    • Membrane Journal
    • /
    • v.22 no.5
    • /
    • pp.301-308
    • /
    • 2012
  • Phosphazene diagnostic membranes were prepared to measure blood glucose level of diabetics. Final absorbances at 680nm through activated phosphazene membranes were measured at various temperature and humidity by varing concentration of glucose in blood. Measuring temperature and humidity did not seriously affected the end-point results of varing absorbance values as time (K/S). The effects of storage temperatures on the measurements of glucose concentration were studied after activated phosphazene diagnostic membranes were stored at various temperatures for 3 days, 1 week, 3 weeks, and 5 weeks. The stabilities of phosphazene dianostic membranes were confirmed even at RH 80%.

Social Isolation Selectively Increases Anxiety in Mice without Affecting Depression-like Behavior

  • Kwak, Chul-Jung;Lee, Sue-Hyun;Kaang, Bong-Kiun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.13 no.5
    • /
    • pp.357-360
    • /
    • 2009
  • It is hypothesized that a number of environmental factors affect animals' behavior. Without controlling these variables, it is very hard for researchers to get not only reliable, but replicable data from various behavioral experiments testing animals' cognitive as well as emotional functions. For example, laboratory mice which had restricted environment showed different synaptic potentiation properties with wild mice (Zhao MG et al., 2009). While performing behavioral experiments, however, it is sometimes inevitable that the researcher changes the animals' environments, as by switching the cages in which experimental animals are housed and separating animals raised together into small experimental groups. In this study, we investigated the effect of environmental changes on mice's emotional behaviors by socially isolating them or reducing the size of their cage. We found that social isolation selectively increases the animals' levels of anxiety, while leaving depression-like behaviors unchanged. On the other hand, alteration of the housing dimensions affected neither their anxiety levels nor their depression-like behaviors. These results suggest that environmental variables may have a prominent impact on experimental animals' emotional behaviors and possibly their psychological states, leading to bias in the behavioral data produced from experiments.

Detection Algorithm and Extract of Deviation Parameters for Battery Pack Based on Internal Resistance Aging (저항 열화 기반의 배터리 팩 편차 파라미터 추출 방안 및 검출 알고리즘)

  • Song, Jung-Yong;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.7
    • /
    • pp.515-520
    • /
    • 2018
  • A large number of lithium-ion batteries are arranged in series and parallel in battery packs, such as those in electric vehicles or energy storage systems. As battery packs age, their output power and energy density drop because of voltage deviation, constant and non-uniform exposure to abnormal environments, and increased contact resistance between batteries; this reduces application system efficiency. Despite the balancing circuit and logic of the battery management system, the output of the battery pack is concentrated in the most severely aged unit cell and the output is frequently limited by power derating. In this study, we implemented a cell imbalance detection algorithm and selected parameters to detect a sudden decrease in battery pack output. In addition, we propose a method to increase efficiency by applying the measured testing values considering the operating conditions and abnormal conditions of the battery pack.

The Multipactor Test results on the X Band filter of Space Qualification Model appropriated for the Geostationary Satellite considering for space environments (우주환경을 고려한 정지궤도위성에 적합한 X대역 필터의 멀티팩터 시험 결과 연구)

  • Park, Jong-hee;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.65-68
    • /
    • 2017
  • In this paper, a multipactor test for the space qualification model of the X-band dual-mode high-power channel filter for high-speed data transmission of geostationary satellite observation payloads was conducted and compared with the 8 dB margin required for design. It was confirmed that analytically required margins were met through testing and that satisfactory test results were obtained. The design and test of the multipactor are tested according to the ECSS standard. Based on this, it is suggested that if the margin of design is sufficiently secured, it can be used in the development of the filter for space qualification model without any test.

  • PDF

Design and Implementation of Federation of Connection management for Interworking (망간 연동을 위한 연결관리 연합기능의 설계 및 구현)

  • Lee, Han-Yeong;Im, Gyeong-Jun;Seo, Dong-Seon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.6
    • /
    • pp.1515-1521
    • /
    • 1996
  • Object-oriented and distributed processing methods are adopted next -generation telecommunications management architecture. In this paper, we design and implement gradual federation function on connection management system providing connection services to transport network for interworking and encapsulated trader and gateway function for testing interoperability of these service objects between distributed processing environments. These techniques are practically applicable to support interworking between heterogeneous management network systems according to a tendency of integrating telecommunications management systems.

  • PDF

A Study on the Analysis of 3 Dimensional Substrate Behaviour of Complex Environmental Deterioration and the Analysis of Results (방수재료 및 공법의 내구성 평가를 위한 복합열화분석용 3차원 거동대응 시험결과)

  • Song, Je-Young;Seo, Hyun-Jae;Choi, Eun-Kyu;Lee, Jung-Hun;Kim, Byoungil;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.189-190
    • /
    • 2018
  • KS standards mostly relate to single component material evaluation, so in cases of underground structure environments, most cannot predict the existing composite forms of deterioration, resulting in the applied waterproofing materials becoming unable to respond to these damaging factors. Current domestic waterproofing market in Korea mainly uses single-ply waterproofing materials comprised of coatings or waterproof sheets and two or more-ply composite waterproofing methods. In order to evaluate these types of composite waterproofing systems, a new test equipment and method that incorporates various deterioration conditions (joint displacement, chemical exposure, water pressure etc) was developed. In a comparison testing, the results showed that flexible type materials have higher response performance towards joint displacement than the hardened material.

  • PDF

Research of Corrosion Growth Degree According in Liquid Environment of Waterworks and Sewer Piping Material (상·하수 배관재의 수 환경에서 부식진전도 연구)

  • Park, Kyeong-Dong;Ki, Woo-Tae;Yu, Hyeong-Ju;Kim, Dong-Uk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.4
    • /
    • pp.33-40
    • /
    • 2006
  • The quality of the supply water which is supplied to consumer is not the thing of water after filtrating but the thing of water from faucet through pipe. As a result, heavy metals and microorganism, that is the major materials, which cause the distrust of the supply water is generated by supply process. Especially, the heavy metal is generated by the corrosion of waterworks. Besides, rupture by corrosion of pipe becomes the factor of supply water's pollution in waterworks and the factor of pollution of the soil and environment in drain pipe. Therefore, this research examined the weight reduction electric potential measure to measure the corrosion degree of piping materials after testing the corrosion of piping materials(Copper Pipe, Galvanized Steel Pipe, Stainless Steel Pipe) which is generally used at the moment in various corrosion environments(subterranean water, supply water, 3.5% NaCl, 3.5% $HNO_3$). And let me show basic design data about problem occurrence such as leakage water, rust water, inside and outside corrosion from this.

  • PDF

A New Test Algorithm for Effective Interconnect Testing Among SoC IPs (SoC IP 간의 효과적인 연결 테스트를 위한 알고리듬 개발)

  • 김용준;강성호
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.1
    • /
    • pp.61-71
    • /
    • 2003
  • Interconnect test for highly integrated environments like SoC, becomes more important as the complexity of a circuit increases. This importance is from two facts, test time and complete diagnosis. Since the interconnect test between IPs is based on the scan technology such as IEEE1149.1 and IEEE P1500, it takes long test time to apply test vectors serially through a long scan chain. Complete diagnosis is another important issue because a defect on interconnects are shown as a defect on a chip. But generally, interconnect test algorithms that need the short test time can not do complete diagnosis and algorithms that perform complete diagnosis need long test time. A new interconnect test algorithm is developed. The new algorithm can provide a complete diagnosis for all faults with shorter test length compared to the previous algorithms.

Ground Firing Test of a 75 Ton Class Engine System for KSLV II and its Structural Vibration Responses (75톤급 액체로켓엔진 지상연소시험 및 진동응답 분석)

  • Kim, Jin-Hyuk;Jeon, Seong Min;Park, Jongyoun;Yoo, Jaehan;Jeong, Eunhwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.928-929
    • /
    • 2017
  • A 75 ton class liquid rocket engine has been developed for KSLV II. Ground firing tests of the rocket engine were conducted to characterize and quantify its structural vibration under combustion testing environments. In this study, evaluation of dynamic response characteristics of the engine system was presented to verify its structural integrity and structural design during ground firing tests.

  • PDF