• Title/Summary/Keyword: Test-retest

Search Result 441, Processing Time 0.031 seconds

The effect of elastic band based of PNF pattern on the U/E function in the spinal cord injury patient (PNF 패턴에 기초한 탄력밴드 훈련이 척수손상 환자의 상지 기능에 미치는 영향)

  • Shin Young-Il;Lee Hyoung-Soo
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.3
    • /
    • pp.152-160
    • /
    • 2004
  • The purpose of this study was to investigate the effect of elastic band based of PNF pattern on the U/E function in the spinal cord injury patient. 11 subjects with spinal cord injury participated in this study. They took elastic band excercise 5 times per week for 8 weeks. One time excercise spent 35minutes. The therapeutic effect was evaluated by Cybex 6000, BTE Work Simulator, how many seconds they needed to walk 100 meters. 11 cases were examined before, after 8 week, elastic band excercise. The results of this study are as follows; 1. Isokinetic power by Cybex 6000 : The elbow flexion, shoulder flexion and extension were significant difference between test-retest(p<.05). but elbow extension were not significant difference between test-retest. 2. BTE Work Simulator : Wheelchair Propulsion and Steering Torque were significant difference between test-retest(p<.05). 3. Wheelchair Propulsion velocity : There were significant difference between test-retest(p<.05). The findings suggest that SCI patients can improve their Isokinetic power on shoulder and elbow joint, wheelchair propulsion and Steering Torque by BTE Work Simulator, Wheelchair Propulsion velocity through elastic band based of PNF pattern.

  • PDF

The Test-Retest Reliability of Subjective Visual Horizontal Testing: Comparisons between Solid and Dotted Line Images

  • Zakaria, Mohd Normani;Wahat, Nor Haniza Abdul;Zainun, Zuraida;Sakeri, Nurul Syarida Mohd;Salim, Rosdan
    • Journal of Audiology & Otology
    • /
    • v.24 no.2
    • /
    • pp.107-111
    • /
    • 2020
  • The present study aimed to determine the test-retest reliability of subjective visual horizontal (SVH) testing when tested with solid and dotted line images. In this repeated measures study, 36 healthy young Malaysian adults (mean age=23.3±2.3 years, 17 males and 19 females) were enrolled. All of them were healthy and had no hearing, vestibular, balance, or vision problems. The SVH angles were recorded from each participant in an upright body position using a computerized device. They were asked to report their horizontality perception for solid and dotted line images (in the presence of a static black background). After 1 week, the SVH procedure was repeated. The test-retest reliability of SVH was found to be good for both solid line [intraclass correlation (ICC)=0.80] and dotted line (ICC=0.78). As revealed by Bland-Altman plots, for each visual image, the agreements of SVH between the two sessions were within the clinically accepted criteria (±2°). The SVH testing was found to be temporally reliable, which can be clinically beneficial. Both solid and dotted lines in the SVH testing are reliable to be used among young adults.

The Test-Retest Reliability of Subjective Visual Horizontal Testing: Comparisons between Solid and Dotted Line Images

  • Zakaria, Mohd Normani;Wahat, Nor Haniza Abdul;Zainun, Zuraida;Sakeri, Nurul Syarida Mohd;Salim, Rosdan
    • Korean Journal of Audiology
    • /
    • v.24 no.2
    • /
    • pp.107-111
    • /
    • 2020
  • The present study aimed to determine the test-retest reliability of subjective visual horizontal (SVH) testing when tested with solid and dotted line images. In this repeated measures study, 36 healthy young Malaysian adults (mean age=23.3±2.3 years, 17 males and 19 females) were enrolled. All of them were healthy and had no hearing, vestibular, balance, or vision problems. The SVH angles were recorded from each participant in an upright body position using a computerized device. They were asked to report their horizontality perception for solid and dotted line images (in the presence of a static black background). After 1 week, the SVH procedure was repeated. The test-retest reliability of SVH was found to be good for both solid line [intraclass correlation (ICC)=0.80] and dotted line (ICC=0.78). As revealed by Bland-Altman plots, for each visual image, the agreements of SVH between the two sessions were within the clinically accepted criteria (±2°). The SVH testing was found to be temporally reliable, which can be clinically beneficial. Both solid and dotted lines in the SVH testing are reliable to be used among young adults.

The Reliability of the Pediatric Functional Muscle Testing in Children with Developmental Delay

  • Seo, Hye-Jung;Kim, Joong-Hwi
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.4
    • /
    • pp.183-189
    • /
    • 2015
  • Purpose: The aim of this study was to examine the test-retest and inter-rater reliability of the pediatric functional muscle testing (PFMT) when applied to children with developmental delay. Methods: Sixteen children with developmental delay (seven females, nine males) participated in this study. For the inter-rater reliability, each was scored on the PMFT by two pediatric physical therapists with more than 8 years of clinical experience on the same day. For assessment of the test-retest reliability, one therapist tested the children again within 10 days. The second measurement was performed by taking a first measurement in video. Intraclass correlation coefficient (ICC) was calculated to determine the test-retest and inter-rater reliability of the PFMT, and Chronbach's alpha was used to measure internal consistency. Results: The results of this study were as follows: 1) The test-retest ICC of the score of the infant action month and the right side of the PFMT was from 0.53 to 1.00 and from 0.63 to 0.99, respectively. 2) The inter-rater ICC of the score of the infant action month and the right side of the PFMT was from 0.66 to 1.00 and from 0.64 to 1.00, respectively. 3) Chronbach's alpha was 0.93. The internal consistency indicated excellent. Conclusion: In conclusion, this study showed that the test-retest and inter-rater reliability of the PFMT was relatively high, except for a few items. Therefore, it can be suggested that the PFMT will be a useful tool for measurement of muscle strength for children with developmental delay if it be some modifications.

A study on the clinical usefulness, validity, and test-retest reliability of the Spirokit, a device that combines the pulmonary function test and respiratory muscle strength test

  • Kim, Byeong-Soo;Lee, Myung-Mo
    • Physical Therapy Rehabilitation Science
    • /
    • v.9 no.2
    • /
    • pp.120-130
    • /
    • 2020
  • Objective: This study was conducted to identify the clinical usefulness, validity, and reliability of the Spirokit, a device that combines the pulmonary function test (PFT) and respiratory muscle strength (RMS) test. Design: Cross-sectional study. Methods: Forty young adults (male: 23, female: 17) participated in a PFT and a RMS test. The concurrent validity for pulmonary function was assessed by comparing data obtained from MicroQuark and the Spirokit and the agreements between the MicroRPM and the Spirokit for RMS were compared. The test-retest reliability of the Spirokit was determined by comparing data obtained from the first and second sessions. The test and retest were performed at the same time after one day for the PFT and RMS test. Validity was estimated using intraclass correlation coefficients (ICCs), and by calculating 95% limits of agreement (LoA). To estimate interrater reliability, ICCs were calculated. Results: The Spirokit showed a high agreement intra class coefficient (ICC [2, 1]): 0.978-0.999, 95% limits of agreements (95% LOA): -0.798 to 0.847 with MicroQuark. It also showed a high level of concordance ICC (2, 1): 0.992 to 0.993, 95% LOA: -9.313 to 11.169 with MicroRPM. The test-retest reliability of the Spirokit was analyzed using ICC (2, 1), and showed a high level of reliability (ICC [2,1]=0.960 to 0.998). Standard error of measurement % (SEM%) was 0.12% to 3.39%, and minimum detectable change% (MDC%) was 0.02% to 3.79%, indicating high level of reliability. Conclusions: The Spirokit is a device with high validity and reliability that can be used to simultaneously measure PFT and RMS tests.

Intratester Reliability of 3 Dimensional Motion Analysis System on Normal Subjects by a Tester (3차원 운동분석 시스템을 이용한 보행분석에 있어서 검사간의 재현도)

  • Lee, Moon-Sook;Wui, Hyang-Mi
    • Journal of Korean Physical Therapy Science
    • /
    • v.2 no.1
    • /
    • pp.383-392
    • /
    • 1995
  • The purpose of this investigation was to determine the intratester reliability of measurements obtained with 3 Dimensional Motion Analysis System(3DMAS) by tester on normal subject. Twenty subjects between the ages of 9 and 29(x=22) were evaluated with 3DMAS using a test-retest reliability procedure after a familiarization session. Computerized 3DMAS was done with 4 50 - Hz CCD cameras connected to the ELITE system(B. T. S., Italy) and kinetic data were collected from the AMTI force platform(AMTI., U. S. A). Data were analyzed by the Eliclinic software to obtain gait parameters, joint angles and joint internal moment and power. Test-retest revealed intraclass correlation coefficients from .80 to .99. A series of paired t-tests revealed no significant differences between test and retest values. Finally, it was concluded that tester with 3DMAS could obtain reliable measurements with 3DMAS for determining kinetic, kinematic and gait parameters in normal subjects.

  • PDF

Construction of a new questionnaire for assessing physical therapy student attitudes towards their education and profession and testing its validity and reliability

  • Tedla, Jaya Shanker
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.1
    • /
    • pp.20-25
    • /
    • 2017
  • Objective: During the physical therapy education, if we can understand the student's attitude then we can make valuable suggestions with respect to the teaching in the universities and professional employment in the country. The aim of the current study is to develop a questionnaire to test the physical therapy students' attitudes towards their education and profession and to test its test-retest reliability and content validity. Design: Cross-sectional study. Methods: A total of 47 physical therapy students who were in their final year were randomly selected to participate in the study. After the making of the questionnaire, it was given to 6 professional experts teaching in the field of physical therapy to obtain their responses for each question with a 5-point Likert scale grading. Their answers were used in making the content validity of the questionnaire. Afterwards, the physical therapy students were asked to fill the questionnaire. Instrument reliability and test-retest reliability were also assessed by having the students complete the questionnaire after one month of taking the questionnaire. Results: The content validity index was 0.71 for the whole scale and values of individual subdivisions were ranging from 0.69 to 0.75. Instrument reliability measured by Cronbach's alpha coefficient was 0.86 for the whole scale and subdivision values were ranging from 0.32 to 0.86. Test-retest reliability was assessed by intraclass correlation coefficient, which was 0.71 for whole scales and subdivision values were ranging from 0.38 to 0.70. Conclusions: This questionnaire, which assesses the physical therapy student attitude towards their education and profession, has good content validity, instrument reliability, and test-retest reliability.

Test-retest Reliability of Sit-to-Stand and Gait Assessment Using the Wii Balance Board (Wii Balance Board를 이용한 Sit-to-Stand와 보행기능 측정의 검사-재검사 신뢰도)

  • Yang, Seong-rye;Oh, Yu-ri;Jeon, Ye-rim;Park, Dae-sung
    • Physical Therapy Korea
    • /
    • v.23 no.3
    • /
    • pp.40-47
    • /
    • 2016
  • Background: Assessments of Sit-to-Stand (STS) and gait functions are essential procedures in evaluating level of independence for the patients after stroke. In a previous study, we developed the software to analyze center of pressure (COP) in standing position on Wii Balance Board (WBB). Objects: This purpose of this study is to measure test-retest reliability of ground reaction forces, COP and time using WBB on STS and gait in healthy adults. Methods: Fifteen healthy participants performed three trials of STS and gait on WBB. The time (s), vertical peak (%) and COP path-length (cm) were measured on both tasks. Additionally, counter (%), different peak (%), symmetry ratio, COP x-range and COP y-range were analyzed on STS, 1st peak (%), 2nd peak (%) of weight were analyzed on gait. Intra-class correlation coefficient (ICC), standard error measurement (SEM) and smallest real difference (SRD) were analyzed for test-retest reliability. Results: ICC of all variables except COP path-length appeared to .676~.946 on STS, and to .723~.901 on gait. SEM and SRD of all variables excepting COP path-length appeared .227~8.886, .033~24.575 on STS. SEM and SRD excepting COP path-length appeared about .019~3.933, .054~11.879 on gait. Conclusion: WBB is not only cheaper than force plate, but also easier to use clinically. WBB is considered as an adequate equipment for measuring changes of weight bearing during balance, STS and gait test which are normally used for functional assessment in patients with neurological problems and elderly. The further study is needed concurrent validity on neurological patients, elderly patients using force plate and WBB.

Reliability of a Newly Developed Tool to Assess and Classify Work-related Stress (TAWS-16) for Indian Workforce

  • Gautham Melur Sukumar;Runalika Roy;Mariamma Philip;Gururaj Gopalkrishna
    • Journal of Preventive Medicine and Public Health
    • /
    • v.56 no.5
    • /
    • pp.407-412
    • /
    • 2023
  • Objectives: Work stress is associated with non-communicable diseases, increased healthcare costs, and decreased work productivity among employees in the information technology sector. There is a need for regular work-stress screening among employees using valid and reliable tools. The Tool to Assess and Classify Work Stress (TAWS-16) was developed to overcome limitations in existing stress assessment tools in India. This study aimed to test the reliability of TAWS-16 in a sample of managerial-supervisory employees. Methods: This observational reliability study included data from 62 employees. Test-retest and inter-method reliability were investigated using a TAWS-16 web application and interview by telephone, respectively. Kappa values and intra-class correlation coefficients were calculated. Internal consistency was assessed through Cronbach's alpha. Results: For both test-retest and inter-method reliability, the agreement for both work-related factors and symptoms suggestive of work stress exceeded 80%, and all kappa values were 0.40 or higher. Cronbach's alpha for test-retest and inter-method reliability was 0.983 and 0.941, respectively. Conclusions: TAWS-16 demonstrated acceptable reliability. It measured stressors, coping abilities, and psychosomatic symptoms associated with work stress. We recommend using TAWS-16 to holistically identify work stress among employees during periodical health check-ups in India.