• Title/Summary/Keyword: Test-retest

Search Result 448, Processing Time 0.023 seconds

Reliability and Validity Study on the Korean Version of the Fullerton Advanced Balance Scale (한국어판 플러턴 어드밴스드 균형 척도의 신뢰도와 타당도 연구)

  • Kim, Gyoung-mo
    • Physical Therapy Korea
    • /
    • v.23 no.1
    • /
    • pp.31-37
    • /
    • 2016
  • Background: The assessment tool developed in other countries should be translated into Korean language using rigorous methodological approaches in order to be used in Korea. Because these procedures are insufficient for establishing the cross-cultural and linguistic equivalence, the need for statistical methods is raised. The Fullerton Advanced Balance Scale was translated into Korean and the content validity was verified through the back translation method, but the reliability and validity have not yet been proven by statistical methods. Objects: The purpose of this study was to investigate the reliability and validity of the Korean version of the Fullerton Advanced Balance Scale (KFAB) by statistical methods in elderly people. Methods: A total of 97 elderly adults (39 males and 58 females) participated in this study. Internal consistency of the KFAB was measured using Cronbach's alpha and an intraclass correlation coefficient (ICC) was used to assess test-retest reliability between the two measurement sessions. Concurrent validity was measured by comparing the KFAB responses with the Korean version of the Berg Balance Scale (KBBS) using the Spearman correlation coefficient. Construct validity of the KFAB was measured using the exploratory factor analysis to evaluate the unidimensionality of the questionnaire. The significance level was set at ${\alpha}=.05$. Results: The internal consistency of the KFAB was found be adequate with Cronbach's alpha (.96), and test-retest reliability was excellent as evidenced by the high ICC (r=.996). Concurrent validity showed high correlation between the KFAB and KBBS (r=.89, p<.001). Construct validity was evaluated using exploratory factor analysis. The result from Bartlett test of sphericity was statistically significant (p<.001), and the value of Kaiser-Meyer-Olkin measure of sampling adequacy was .93. Exploratory factor analysis revealed the existence of only one dominant factor that explained 76.43% of the variance. Conclusion: The KFAB is a reliable, valid and appropriate tool for measuring the balance functions in elderly people.

Reliability and Validity of the Measurement of Pelvic Movement in Low Back Pain Patients using Cushion Sensor in Sitting Position (앉은 자세에서 방석센서를 이용한 요통환자 골반가동성 측정의 신뢰도와 타당도)

  • Jung, Seung-Hwa;Park, Dae-Sung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.2
    • /
    • pp.83-91
    • /
    • 2020
  • PURPOSE: Postural and structural asymmetry due to muscle imbalances around the lower back and pelvis are the causes of back pain. Muscle imbalances in patients with chronic low back pain affect the pelvic tilt and movement, and it is necessary to assess the pelvic movement ability using the appropriate tools to determine the mediating effects of lower back pain. This paper reports the reliability and validity of the Sensbalance Therapy Cushion (STC) for pelvic movement and proprioception. METHODS: In this study, the Wii balance board (WBB) was used as a golden standard for pelvic movement measurements. FABQ, KODI, Myovision, and Pelvic movement were measured in 50 patients with chronic low back pain. The correlation between the lower-back muscle activity and pelvic movement was checked. The pelvic movement parameter was measured twice to determine the intra-rater reliability. RESULTS: The STC showed high test-retest reliability in the pelvic tilt measurements (ICC = .672 - .809). The test-retest reliability of proprioception measurements (ICC = .588 - .859) and reaction time measurements (ICC = .542 - .836) were also high. The relationship between the WBB and STC showed a significant positive correlation with the pelvic tilt test (p < .01). The posterior pelvic tilt and lower-back muscle activity showed a significant negative correlation (p < .01). The pelvic left tilt and lower-back muscle activity showed a significant negative correlation (p < .05). CONCLUSION: The results revealed the high reliability and validity of the STC. Therefore, the STC can be used as an objective measuring device for evaluating pelvic tilt, proprioception, and reaction time in low back pain patients.

A Study on the Development of the Core Emotional Assessment Questionnaire (CEAQ) Based on the Seven Emotions (七情) (한의학 칠정(七情)에 기반을 둔 핵심감정평가척도 개발 연구)

  • Lee, Go-Eun;Park, Bo-Young;Moon, Kwang-su;You, Jae-Min;Kang, Hyung-Won
    • Journal of Oriental Neuropsychiatry
    • /
    • v.26 no.2
    • /
    • pp.143-160
    • /
    • 2015
  • Objectives: The study purpose was to test the validity and reliability of the core emotional assessment questionnaire based on the seven emotions. Methods: Survey data were from 651 individuals and contained 141 items determined from a previous pilot study. Among the participants, 241 were retested. First, following analysis of the internal consistency reliability of the 141 items, we deleted items with Cronbach-$\alpha$ coefficient below 0.5. We then selected 100 final items after the first factor analysis. Second, the final 100 items were evaluated by internal consistency reliability, test-retest reliability, factor analysis, and correlational analysis. Results: Cronbach-$\alpha$ coefficient for the final 100 items were 0.866~0.956 and the test-retest reliability were above 0.70. The 100 items categorized into 7 factors explained 53.8% of the total variance. Analyzing the correlation of each chiljeong, we had a high positive correlation above 0.70 between sa and bi, bi and u, gong and kyeong. Conclusions: The final 100 items used for the core emotional assessment questionnaire based on the seven emotions showed satisfactory reliability and validity. Thus, it may be an appropriate instrument for measuring Chiljeong in the general population.

Reliability and Validity of the North Korean Version of Center for Epidemiologic Studies Depression Scale (CES-D-NK) (북한어판 CES-D(Center for Epidemiologic Studies Depression Scale-North Korea ; CES-D-NK)의 신뢰도와 타당도)

  • Park, Sung-Jin;Lee, So Hee;Jun, Jin Yong;Lee, Taeyeop;Han, Jeong Mee;Ahn, Myung Hee;Hong, Jin Pyo
    • Anxiety and mood
    • /
    • v.11 no.1
    • /
    • pp.54-60
    • /
    • 2015
  • Objective : To translate Center for Epidemiologic Studies Depression Scale (CES-D) into North Korean language and to examine its reliability and validity Methods : North Korean defectors (n=207) recruited from the call center for North Korean defectors participated. Psychiatrists and psychiatric residents interviewed the participants and made the psychiatric diagnoses. Subsequently, the participants completed the CES-D, Impact of Event-Scale-Revised-North Korea (IES-R-NK), Alcohol Use Disorders Identification Test-North Korea (AUDIT-NK), and Brief Psychological State Inventory for North Korean Refugees (BPSI-NKR) questionnaires. Of the original participants, 143 subjects participated in test-retest reliability study after one week. Results : Cronbach's alpha coefficient of CES-D-NK was superior in both males (0.91) and females (0.93). The test-retest correlation coefficient was high (males, 0.64 ; femals, 0.79). Good convergent validity was evident by significant correlations with IER-R-NK, BPSI-NKR-Depression and BPSI-NKR-PTSD, respectively. CES-D-NK had no or weak correlations with AUDIT-NK and BPSI-NKR-Alcohol, showing its discriminant validity. Conclusion : CES-D-NK could be a reliable and valid tool for screening and assessing depressive symptoms of North Korean defectors.

Validation of the Thai Version of aWork-related Quality of Life Scale in the Nursing Profession

  • Sirisawasd, Poramate;Chaiear, Naesinee;Johns, Nutjaree Pratheepawanit;Khiewyoo, Jiraporn
    • Safety and Health at Work
    • /
    • v.5 no.2
    • /
    • pp.80-85
    • /
    • 2014
  • Background: Currently available questionnaires for evaluating the quality of worklife do not fully examine every factor related to worklife in all cultures. A tool in Thai is therefore needed for the direct evaluation of the quality of worklife. Our aim was to translate the Work-related Quality of Life Scale-2 (WRQLS-2) into Thai, to assess the validity and reliability of the Thai-translated version, and to examine the tool's accuracy vis-$\grave{a}$-vis nursing in Thailand. Methods: This was a descriptive correlation study. Forward and backward translations were performed to develop a Thai version of the WRQLS. Six nursing experts participated in assessing content validity and 374 registered nurses (RNs) participated in its testing. After a 2-week interval, 67 RNs were retested. Structural validity was examined using principal components analysis. The Cronbach's alpha values were calculated. The respective independent sample t test and intraclass correlation coefficient were used to analyze known-group validity and test-retest reliability. Multistate sampling was used to select 374 RNs from the In- and Outpatient Department of Srinagarind Hospital of the Khon Kaen University (Khon Kaen, Thailand). Results: The content validity index of the scale was 0.97. Principal components analysis resulted in a seven-factor model, which explains 59% of the total variance. The overall Cronbach's alpha value was 0.925, whereas the subscales ranged between 0.67 and 0.82. In the assessment results, the known-group validity was established for the difference between civil servants and university employees [F (7.982, 0.005) and t (3.351; p < 0.05)]. Civil servants apparently had a better quality worklife, compared to university employees. Good test-retest reliability was observed (r = 0.892, p < 0.05). Conclusion: The Thai version of a WRQLS appears to be well validated and practicable for determining the quality of the work-life among nurses in Thailand.

Psychometric Evaluation of the Korean Social Support Questionnaire (한국 사회적지지 측정도구 개발)

  • Oh, Ka-Sil;Oh, Kyong-Ok;Lee, Sook-Ja;Kim, Jeong-Ah;Jeong, Chu-Ja;Kim, Hye-Ryoung;Jun, Hoa-Yun;Kang, Jung-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.6
    • /
    • pp.881-890
    • /
    • 2008
  • Purpose: Research related to social support in Korea has been hampered by paucity of measurement tools reflecting Korean culture. The aim of the study was to develop Korean social support questionnaire (KSSQ) based on the Korean social support pyramid and to test psychometric properties of the KSSQ. Methods: The questionnaire was administered to 701 subjects and 658 college students. Psychometric analyses included factor analyses, expert validity, criterion-related validity, internal consistency, and test-retest reliability. Results: A principal components analysis support for construct validity, eliciting a three factor solution accounting for 65.46% of variance in scores. Concurrent and discriminant validity supported criterion-related validity. Internal consistency of reliability was support with Cronbach's alpha of .97-.98 for the entire scale. Test-retest reliability was .76. Conclusion: This initial testing of KSSQ to measure Korean social support demonstrates evidence of reliability and validity. Assessment of known-group validity and norm establishment of KSSQ are suggested to provide further sound psychometric properties and practical measurement tools.

Converged Study on the Validity and Reliability of the Communication Behavioral Scale of nurses caring for people with dementia (치매대상자를 돌보는 간호사의 의사소통행위 측정도구의 타당도 및 신뢰도 융합 연구)

  • Gang, Moon-Hee;Lee, Ji-Hye
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.5
    • /
    • pp.327-333
    • /
    • 2020
  • The aims of this study was to verify the validity using group comparison method and test/retest reliability of the Communication Behavior Scale for Nurses Caring for People with Dementia(CBS-D). The subjects were nurses who have worked at elderly care facilities in D, U and Y cities(n = 67), and nurses who have worked at general hospitals in D and U cities. The scores of the communication behaviors of nurses working in elderly care facilities were significantly higher than those of nurses working in general hospitals(t=2.49, p=.014). The Intraclass Correlation Coefficients for the test-retest reliability test was .813. Therefore, it was confirmed that CBS-D is an appropriate evaluation tool for evaluating the level of the nurse's communication behavior through various logical analyzes, and it is expected that it can be used in various ways for nursing care for people with dementia.

Reliability and validity of new evaluation methods using static surface electromyography in persons with neck pain

  • Kim, Go-Eun;Yun, Dong-Uk;An, Yu-Ju;Park, Dae-Sung;Ham, Joo-Hyun
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Objective: The aim of this study was to evaluate the validity and reliability of using static surface electromyography (sEMG) on persons with neck pain and in healthy adults. Design: Cross-sectional study. Methods: Twenty-two female participants with neck pain and thirty healthy adults in the age group of 20-65 years were recruited in this study. To evaluate the validity and reliability of sEMG in subjects with neck pain, the subjects'characteristics were recorded and the Visual Analog Scale (VAS) and Neck Disability Index (NDI) were examined in addition to sEMG and algometer tests being carried out on the subjects. The site for using the sEMG and algometer was the upper trapezius. sEMG test-retest reliability was measured by intraclass correlation coefficients (ICCs). Independent t-tests were used to analyze the differences in the dependent variables between subjects with neck pain and healthy adults. The Pearson correlation coefficient was used to examine the linear relationship between measured variables. Results: sEMG and algometer tests were reliable according to the test-retest reliability results in subjects with neck pain and healthy adults (ICC=0.815-0.979). The results of this study showed that there were significant differences in respect to age, VAS, sEMG and algometer tests between persons with neck pain and healthy adults (p<0.05). The VAS and NDI were statistically correlated with sEMG and algometer results (p<0.05). Conclusions: In this study, we investigated the clinical usefulness of the static sEMG test in evaluating the pain scale of persons with neck pain with high reliability and validity.

The Reliability and Validity of the Korean Version of Behavioral Activation for Depression Scale (한글판 행동활성화 척도의 신뢰도와 타당도)

  • Oh, Ji-Hye;Hwang, Na-Ri;Cha, Yun-Ji;Lee, Eun-Byeol;Choi, Kee-Hong;Seo, Ho-Jun
    • Journal of Korean Neuropsychiatric Association
    • /
    • v.56 no.2
    • /
    • pp.89-97
    • /
    • 2017
  • Objectives The Behavioral Activation of Depression Scale (BADS) has been reported to be a valid tool for assessing the different behavioral aspects of depression, such as activation, rumination or avoidance, and functional impairment. The aim of this study was to assess the reliability and validity of the Korean version of BADS (K-BADS). Methods A sample of 196 outpatients completed the K-BADS and the data were analyzed for internal consistency and factor structures. An additional 51 outpatients re-filled the K-BADS after two weeks for the test-retest reliability. To test for the validity, the Hospital Anxiety and Depression Scale (HADS), Working Alliance Inventory (WAI), Drug Attitude Inventory-10 (DAI-10), and Mindfulness Attention Awareness Scale (MAAS) were administered. Results Internal consistency of K-BADS was good (Cronbach's alpha=0.843) and principal component factor analysis revealed the four-factor structure. The K-BADS showed a reasonable test-retest reliability (r=0.863, p<0.001). The total score of K-BADS correlated significantly with the total scores of the HADS depression (r=-0.694) and HADS anxiety (r=-0.681). No correlations were found between the K-BADS and the K-WAI (r=0.170) and between the K-BADS and the K-DAI-10 (r=0.311). Conclusion The K-BADS is a reliable and valid instrument for measuring the behavioral activation for depression in Korean patients with depressive symptoms.

Reliability and Validity Study of Inertial Sensor-Based Application for Static Balance Measurement

  • Park, Young Jae;Jang, Ho Young;Kim, Kwon Hoi;Hwang, Dong Ki;Lee, Suk Min
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.3
    • /
    • pp.311-320
    • /
    • 2022
  • Objective: To investigate the reliability and validity of static balance measurements using an acceleration sensor and a gyroscope sensor in smart phone inertial sensors. Design: Equivalent control group pretest-posttest. Methods: Subjects were forty five healthy adults aged twenty to fifty-years-old who had no disease that could affect the experiment. After pre-test, all participants wore a waist band with smart phone, and conducted six static balance measurements on the force plate twice for 35 seconds each. To investigate the test-retest reliability of both smart phone inertial sensors, we compared the intra-correlation coefficient (ICC 3, 1) between primary and secondary measurements with the calculated root mean scale-total data. To determine the validity of the two sensors, it was measured simultaneously with force plate, and the comparision was done by Pearson's correlation. Results: The test-retest reliability showed excellent correlation for acceleration sensor, and it also showed excellent to good correlation for gyroscope sensor(p<0.05). The concurrent validity of smartphone inertial sensors showed a mostly poor to fair correlation for tandem-stance and one-leg-stance (p<0.05) and unacceptable correlation for the other postures (p>0.05). The gyroscope sensor showed a fair correlation for most of the RMS-Total data, and the other data also showed poor to fair correlation (p<0.05). Conclusions: The result indicates that both acceleration sensor and gyroscope sensor has good reliability, and that compared to force plate, acceleration sensor has unacceptable or poor correlation, and gyroscope sensor has mostly fair correlation.