• 제목/요약/키워드: Test-equipment

검색결과 3,411건 처리시간 0.031초

Development of Ultrasonic Test Equipment for Investigating the Morphology of Barrier Materials

  • Kim Sung-Ho;Lee Young-Sam
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제6권3호
    • /
    • pp.217-222
    • /
    • 2006
  • Recently, LG chemical corporation developed new material called HYPERIER, which has an excellent barrier characteristic. It has many layers which are made of nano-composite within LDPE(Low-Density Poly Ethylene). In order to guarantee the quality of the final product from the production line, a certain test equipment is required to investigate the existence of layers inside the HYPERIER. In this work, ultrasonic sensor based test equipment for investigating the existence of inner layers is proposed. However, it is a tedious job for human operators to check the existence by just looking at the resounding waveform from ultrasonic sensor. Therefore, to enhance the performance of the ultrasonic test equipment, wavelet and PCA(Principle Componet Analysis) schemes are introduced into neural network scheme which is used for classification. To verify the feasibility of the proposed scheme, some experiments are executed.

초고온 열하중 부가장치 개발 및 적용 (Development and Application of the Super High Temperature Thermal Test Equipment)

  • 전준탁;강휘원;양명석
    • 한국항공우주학회지
    • /
    • 제43권1호
    • /
    • pp.33-39
    • /
    • 2015
  • 본 논문은 램프의 수명저하 없이 $1,000^{\circ}C$이상의 초고온 급속가열 환경을 지속적으로 모사할 수 있고 기존 사용해온 열하중 부가장치 대비 내구성과 신뢰성이 향상된 열하중 부가장치를 개발하여 초고속 비행체 날개의 구조 건전성 평가에 적용, 그 활용가능성을 수록한 내용이다. 본 시험을 통하여 초고온의 운용환경에 노출되는 비행체 날개의 공력가열에 의한 강성저하를 정량적으로 예측할 수 있었으며, 향후 비약적인 증가추세에 있는 공력가열온도를 경험하게 되는 극초음속 비행체에 대한 고온환경에서의 구조 강도특성 평가가 가능해짐으로써 시험 신뢰성 향상과 함께 고온구조강도시험 수행능력을 한 단계 도약시킬 수 있는 계기가 되었다.

RF COMPATIBILITY TEST BETWEEN KOMPSAT AND TTC STATION

  • Ahn, Sang-Il;Choi, Hae-Jin
    • Journal of Astronomy and Space Sciences
    • /
    • 제16권2호
    • /
    • pp.191-198
    • /
    • 1999
  • Results of RF compatibility test between KOMPSAT(Korea Multi-Purpose SATellite) and TTC(Tracking, Telemetry, and Command) station are described. S/C(Spacecreft) RF Test, telemetry test, command test, ranging test, and tracking receiver test were performed with respect to pass/fail criteria. To provide physical RF interface between KOMPSAT and TTC equipment, direct low cable and antenna-to-antenna interface were implemented. Through RF compatibility test, it was fully demonstrated that KOMPSAT and TTC equipment are functionally workable.

  • PDF

Study on Influences and Elimination of Test Temperature on PDC Characteristic Spectroscopy of Oil-Paper Insulation System

  • Liu, Xiao;Liao, Ruijin;Lv, Yandong;Liu, Jiefeng;Gao, Jun;Hao, Jian
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1107-1113
    • /
    • 2015
  • Test temperature is an important factor affecting the measurement results of dielectric response of field power transformers. In order to better apply the polarization and depolarization current (PDC) to the condition monitoring of oil-paper insulation system in power transformers, the influences and elimination method of test temperature on PDC characteristic spectroscopy (PDC-CS) were investigated. Firstly, the experimental winding sample was measured by PDC method at different test temperatures, then the PDC-CS was obtained from the measurement results and its changing rules were discussed, which show that the PDC-CS appears a horizontal mobility with the rise of temperature. Based on the rules, the “time temperature shift technique” was introduced to eliminate the influence of test temperature. It is shown that the PDC-CS at different test temperatures can be converted to the same reference temperature coincident with each other.

The Performance Analysis to Identify the Reuse and Assembly Impact of Temporary Equipment

  • Bae, Sung-Jae;Park, Jun-Beom;Kim, Jung-Yeol;Kim, Young-Suk;Kim, Jun-Sang;Jo, Jae-Hun
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.1252-1252
    • /
    • 2022
  • Temporary work that utilizes temporary equipment (e.g., system scaffold and system pipe support) in construction work is one of the most vulnerable work from a safety perspective in South Korea. Typically, temporary equipment is reused at construction sites. The Korea Occupational Safety and Health Agency announced guidelines regarding the performance standards for reusable temporary equipment to prevent the accidental collapse of temporary facilities. Nevertheless, temporary facilities' collapse still occurs, which could be attributed to a degradation in the performance due to the reuse of temporary equipment. Therefore, this study investigated the performance of simple temporary structures assembled with new and reused equipment. To this end, an experimental module was designed based on previous research cases, and two experimental models were constructed, in which one was assembled using new equipment (Model A), and the other was built using reused equipment (Model B). To determine the performance of each model, a load test was conducted to measure the maximum load that each model could withstand. The experimental results revealed that the maximum load of Model B was 15% lower than that of Model A. This indicates that there is a meaningful performance difference between those two models. Based on this result, the authors decided to perform additional tests with more realistic models than previous ones. The new experimental module was designed to ensure compliance with the Korean design guidelines. In this presentation, the authors show details of the first tests and their results and plan for the additional test.

  • PDF

수두차를 이용한 해저퇴적물 흡입장비 개발에 관한 연구 (A Study on the Development of Inhalation Equipment for Seabed Sediment by the Difference of Water Head)

  • 이영길;손충렬;정우철;김강신;정광열
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.261-264
    • /
    • 2006
  • This paper deal with development of dredging equipment that proper water head elimination method changing transitional dredging method. Numerical simulation and model test were accomplished for development of seabed sediment inhalation equipment using water head. Sediment elimination system by the difference of water head has been analysed by numerical method. Model test was achieved for inhalation equipment performance test using water head by primary design. Also sediment elimination system has designed and developed that doesn't occur secondary pollution phenomenon. To verify the numerical results are compared with experimental results.

  • PDF

대시야 백색광 간섭계를 이용한 Flip Chip Bump 3차원 검사 장치 (Flip Chip Bump 3D Inspection Equipment using White Light Interferometer with Large F.O.V.)

  • 구영모;이규호
    • 한국지능시스템학회논문지
    • /
    • 제23권4호
    • /
    • pp.286-291
    • /
    • 2013
  • 대시야 백색광간섭계(WSI ; White Light Scanning Interferometer)를 이용하여, Flip Chip Bump 검사 공정에 적용하는 것을 목적으로 한 인라인 형태의 플립칩 범프 3차원 검사 장치를 개발한다. 여러 서브스트레이트에 있는 플립칩 범프 높이 측정 결과와 이에 의한 동일한 여러 범프에 대한 반복성 측정 실험 결과를 제시한다. 테스트 벤치에서의 실험 결과와 개발된 플립칩 범프 3차원 검사 장치에서의 실험 결과를 비교하였으며 진동의 영향이 감소되어 개선된 반복성 실험 결과를 얻을 수 있었다. 플립칩 범프 3차원 검사 장치의 검사성능을 평가할 수 있는 기준을 제시한다.

굴착기 내구시험 모니터링을 위한 작업부하 지표 개발 (Development of a Workload Index for Monitoring Durability Test of an Excavator)

  • 조재홍;나선준;김민석;박명관
    • 드라이브 ㆍ 컨트롤
    • /
    • 제19권4호
    • /
    • pp.29-35
    • /
    • 2022
  • In this paper, we developed a workload index for monitoring the durability test using operation information of an excavator. First, the acceleration and cylinder pressure were selected as load factors by analyzing operation data. Through load correlation analysis according to each load factor, Root Mean Square (RMS) and Work Load Range (WLR) were respectively derived as a load feature representing mechanical load. In addition, the workload index was used to quantify load features. For applying the workload index to monitoring, a real-time monitoring system consisting of sensors and embedded controller was installed on the excavator and the system was integrated with a remote monitoring environment using a wireless network. Results of load monitoring and analysis verified that the developed workload index was effective from the viewpoint of the relative comparison of the workload.

치과 방사선 발생기의 성능평가에 관한 연구 (Study on Performance Evaluation of Dental X-ray Equipment)

  • 정재은;정재호;강희두;이종웅;나극환
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.115-119
    • /
    • 2009
  • I think this will be valuable reference for assuring consistency and homogeneity of clarity and managing dental radiation equipment by experimentation of dental radiation equipment permanent which based on KS C IEC 61223-3-4 standard and KS C IEC 61223-2-7. Put a dental radiation generator and experiment equipment as source and film(sensor) length within 30 em, place the step-wedge above the film(sensor). Tie up tube voltage 60 kVp, tube current 7 mA and then get an each image through CCD sensor and film by changing the exposure time as 0.12sec, 0.25sec, 0.4sec. Repeat the test 5times as a same method. Measure the concentration of each stage of film image, which gained by experiment, using photometer. And the image that gained by CCD sensor, analyze the pixel value's change by using image J, which is analyzing image program provided by NIH(National Institutes of Health). In case of film, while 0.12sec and 0.25sec show regular rising pattern of density gap as exposure time's increase, 0.4sec shows low rather than 0.12sec and 0.25sec. In case of CCD sensor density test, the result shows opposite pattern of film. This makes me think that pixels of CCD's sensor can have 0~255 value but it becomes saturation if the value is over 255. The way that getting clear reception during decreasing human's exposed radiation is one of maintaining an equipment as a best condition. So we should keeping a dental radiation equipment's condition steadily through cyclic permanent test after factor examination. Even digital equipment doesn't maintain a permanent, it can maintain a clarity by post processing of image so that hard to set it as standard of permanent test. Therefore it would be more increase the accuracy that compare a film as standard image. Thus I consider it will be an important measurement to care for dental radiation equipment and warrant homogeneity, consistency of dental image's clarity through comparing pattern which is the result from factor test against cyclic permanent test.

  • PDF

이중충격파형 충격시험장비를 이용한 충격시험 결과 및 분석 (The Shock-Test Result and Analysis Using Dual-Pulse Shock Testing Machine)

  • 배종수
    • 한국군사과학기술학회지
    • /
    • 제21권3호
    • /
    • pp.342-348
    • /
    • 2018
  • The important issue of equipment installed in maritime weapon system is shock survivability against underwater explosion(UNDEX). If the shock survivability of equipment should not be guaranteed, the successful mission also could not be achieved. For that reason, the shock-resistance of each equipment under UNDEX environment should be demonstrated before deployment at combat field. However, the actual UNDEX test on the ocean is too expensive to conduct. Also, it has diverse dangerous factors. The main characteristic of UNDEX is a dual-pulse shock. The vertical shock test machine able to simulate dual pulse shock signal on the ground will be introduced in this paper. The dual-pulse shock signal presented in certain shock standard was achieved with this shock-test machine on the ground. The analytical procedure to set a test condition was verified by comparing simulation result with experiment result.