• Title/Summary/Keyword: Test-equipment

Search Result 3,427, Processing Time 0.026 seconds

A Study on Balanced -type Oseillating Mole-Drainer(III)-Model Test for Draft Force, Torque, Power and Moment (평행식 진동탄환 암거 천공기의 연구(III)-견인력, 토크, 동력 및 모멘크에 관한 모형시험-)

  • 김용환
    • Journal of Biosystems Engineering
    • /
    • v.1 no.1
    • /
    • pp.1-6
    • /
    • 1976
  • This paper is the third one of the study on balanced type oscillating mole-drainer, the first one was presented in No 9. Gyeongsang College Report and the second one in Vol. 17, No.4 of the KSAE. In the first part of this study, the characteristics of traction forces between the nonoscillating earth working equipments and oscillating ones was compared. A model of the balanced type oscillating mole-drainer, which composed of a mechanism that may reduce the machine vibration, was designed following the dimensional analysis and similitude technique. The model test was carried out to clarify the balancing mechanism of the oscillating parts and other parts of the machine. In the light of the results from the model tests, a prototype machine was made for experimental purpose. Results from the field test by a reported in the near future. In the second report, the model tests were carried out under the same soil conditions, i.e, . oscillating frequency, running velocity, and oscillating amplitude, etc. It was clear that use of balanced type oscillating model could substantially reduce the vibration of the whole system of the machine, when compared with the nonoscillating type model. In this paper(the third report), results of investigation on the traction force, power requirement, and moment. etc, is presented. Analysis of variance technique was used for analyzing the effect of the frequency, amplitude, and running velocity on the draft force, torque, power requirements, and moments. The results obtained from the model tests are as follows, 1) By practicing a balanced-type oscillating mole-drainer, it was possible to reduce the traction resistance by 55.1-61. 2 percent of traction resistance, however, was 1.75 - 1.95 times greater than the value of resistance which was induced by use of a mole-drainer with single bullet. The resistance of rear shank against soil was considered as a main causing factor of the above results. 2) As the oscillation frequency was increased, the traction resistance was decreased. Considering on the effect of oscillation the greater the amplitude, and the slower the running velocity was, the greater the reduction ratio of traction resistance was. 3) The ratio of the traction resistance of oscillating mole-drainer to that of non-oscillating one could be represented as a function of dimensionless variable (V/$Af$). The results from the tests were well agreed with the reported results from the experim ents on oscillation plow or hoe. 4) By taking a lower value of (V/$Af$), reducing the traction resistance was possible. This fact meant, however, that the efficiency of mole drain practice would be lower. 5) It was experimentally confirmed under the same condition of soil that the variable (R/$rD1^3$) could be represented as a function of a variable($V^2/gD$) when a non\ulcornerocillating mole-drainer was used. 6) When a oscillating mole-drainer was used, the variable(R/$rD_1^{3}$) could be represented as a function of two variables ($v^2/gD_1$) and (V^2/gD_1$). 7) The torque was not affected by a change of frequency. However, a relation of proportionality existed between torque and amplitude, running velocity, and ratio of bullet diameter. When a balanced type oscillating mole-drainer with two bullets was used, torque was increased by 52.8-78. 4 percent and total power requirement was also increased. 8) Total power requirement was increased linearly in accordance with the increasing frequency, 41.96 percent of total power was used for oscillating action. The magnitude of total power requirement was 1. 8-9. 4 times greater than that of a non-oscillating mechanism. In the view point of power requirement, it was not advisable to increase the frequency, amplitude, running velocity, and ratio of bullet diameter at the same time. 9) Only the positive moment occured in the rear shank. Change of the diameter of a rear bullet, could not affect the balancing against the soil resistance. It was necessary for rear bullet to have a large resistance against soil only when the rear bullet was in backward motion. 10) Within an extent of the experimental base, optimum limits for several design factors were A=0.5cm, $f$=22.5Hz, V=O. 05m/sec, and $\lambda$=1.0 By adapting these values traction resistance was reduced by 40 percent and vibration acceleration wa s reduced by 60 percent. Even though the total , power requirements for operating a balanced type oscillation mechanism was greater ~than that of non-oscillating one, using a oscillating mechanism would be more effective. Because a balanced type oscillating mechanism is used, tractive resistance will be reduced and then the lighter . tractive equipment could be used.

  • PDF

Evaluating the Usefulness of the ICT Tuberculosis Test Kit for the Diagnosis of Tuberculosis (결핵 진단에서 ICT Tuberculosis Test Kit의 효용성)

  • Chang, Chul-Hun;Son, Han-Chul;Ryu, Ki-Chan;Park, Soon-Kew;Lee, Seon-Ho;Kim, Sung-Ryul;Park, Ki-Hyung;Kim, Woo-Seok;Koo, Kyong-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.473-480
    • /
    • 1999
  • Background: Early diagnosis of tuberculosis is critical, especially in Korea, an area where tuberculosis is endemic. Because antibody responses to some membrane proteins of Mycobacterium tuberculosis are not comparable, and the policy of BCG vaccination and the prevalence of tuberculosis are different from country to country, the usefulness of the serological diagnostic tests is questionable in Korea, even though they have been confirmed to be useful in other countries. In the specific context of Korea, we tried to evaluate the validity of the ICT Tuberculosis Test (ICT), a membrane-based antibody kit that purports to detect the 5 M. tuberculosis complex-specific antigens including 38-kDa protein. Method: 68 patients with tuberculosis were tested : 37 had no history of previous tuberculosis, and 31 were reactivated cases. The control group comprised 77 subjects : 25 healthy adults, 35 hospital workers with frequent contact with tuberculosis patients, and 17 in-patients with non-tuberculous respiratory diseases. Results: The diagnostic sensitivities of the ICT were 87% and 73% in patients with versus without previous history of tuberculosis, respectively. The sensitivities of smear-positive and smear-negative patient groups were 81% and 73%, respectively. Both of the two patients with extrapulmonary tuberculosis tested positive through the ICT. The specificities of the ICT were 88%, 94%, and 94% in healthy adults, hospital workers, and non-tuberculous patients, respectively, with an overall specificity of 92%. Conclusion: It is suggested that when combined with traditional techniques, the ICT is an useful tool for the diagnosis of pulmonary tuberculosis. The procedure is simple, easy to perform, rapid, and needs no equipment. It shows 73% sensitivity and 92% specificity for the diagnosis of tuberculosis.

  • PDF

Neuroprotective Effects of Modified Yuldahanso-tang (MYH) in a Parkinson's Disease Mouse Model (MPTP로 유도된 Parkinson's disease 동물 모델에서 열다한소탕 가감방 (MYH)의 신경 세포 보호 효과)

  • Go, Ga-Yeon;Kim, Yoon-Ha;Ahn, Taek-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.27 no.2
    • /
    • pp.270-287
    • /
    • 2015
  • Objectives To evaluate the neuroprotective effects of modified Yuldahanso-tang (MYH) in a Parkinson's disease mouse model. Methods 1) Four groups (each of 8 rats per group) were used in this study. 2) The neuroprotective effect of MYH was examined in a Parkinson's disease mouse model. C57BL/6 mice treated with 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP, 30 mg/kg/day), intraperitoneal (i.p.) for 5 days. 3) The brains of 2 mice per group were removed and frozen at $-20^{\circ}C$, and the striatum-substantia nigra part was seperated. The protein volume was measured by Bradford method following Bio-Rad protein analyzing kit. Using mouse/Rat Dopamine ELISA Assay Kit. 4) The brains of 2 mice per group were separated and removed. TH-immunohistochemical was examined in the MPTP-induced Parkinson's disease mice to evaluate the neuroprotective effects of MYH on ST and SNpc. 5) Two mice out of each group were anesthetized and skulls were opened from occipital to frontal direction to take out the brains. The brains added TTC solution for 20 minutes for staining. 6) The water tank used for morris water maze test was filled with $28^{\circ}C$ water, and a round platform of 10cm in diameter was installed for mice to step on. The study was carried out once a day within 30 seconds, keep exercising to step on the platform in the pool. 7) The brains of two mice out of each group were fixed in 10% formaldehyde solution and paraphillin substance was infiltrated. They were fragmented by microtome, and observed under an optical microscope after Hematoxylin & Eosin staining. 8) A round acrylic cylinder with its upper side open was filled with clean water and depressive mouse models were forced to swim for 15 minutes. After 24 hours the animals were put in the same equipment for 5 minutes and were forced to swim. 9) The convenient, simple, and accurate high-performance liquid chromatography (HPLC) method was established for simultaneous determination of Neurotransmitters in MPTP-MYH group. Results 1) MYH possess Dopamine cell protective effect on MPTP-induced injury in striatum and substantia nigra pars compacta. 2) MYH inhibits the loss of tyrosine hydroxylase-immunoreacitive (TH-IR) cells in the striatum and substantia nigra pars compacta on MPTP-induced injury in C57BL/6 mice. 3) MYH possesses improvement effect on MPTP-induced memory deterioration in C57BL/6 mice through the reduction of prolongated Sort of lost time by MPTP injection using the Morris water maze test. 4) MYH possesses hippocampal neuron protective effect on MPTP-induced injury in C57BL/6 mice. 5) MYH possesses improvement effect on MPTP-induced motor behaviour deficits and depression in C57BL/6 mice through the reduction of prolongated losing motion by MPTP injection using the Forced swimming test. 6) MYH increases serotonin product amount on MPTP-induced injury in C57BL/6 mice. Conclusions This experiment suggests that the neuroprotective effect of MYH is mediated by the increase in Dopamin, TH-ir cell, Hippocampus and Serotonin. Furthermore, MYH essential oil may serve as a potential preventive or therapeutic agent regarding Parkinson's disease.

A Study on the Fabrication and Comparison of the Phantom for CT Dose Measurements Using 3D Printer (3D프린터를 이용한 CT 선량측정 팬텀 제작 및 비교에 관한 연구)

  • Yoon, Myeong-Seong;Kang, Seong-Hyeon;Hong, Soon-Min;Lee, Youngjin;Han, Dong-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.737-743
    • /
    • 2018
  • Patient exposure dose exposure test, which is one of the items of accuracy control of Computed Tomography, conducts measurements every year based on the installation and operation of special medical equipment under Article 38 of the Medical Law, And keep records. The CT-Dose phantom used for dosimetry can accurately measure doses, but has the disadvantage of high price. Therefore, through this research, the existing CT - Dose phantom was similarly manufactured with a 3D printer and compared with the existing phantom to examine the usefulness. In order to produce the same phantom as the conventional CT-Dose phantom, a 3D printer of the FFF method is used by using a PLA filament, and in order to calculate the CTDIw value, Ion chambers were inserted into the central part and the central part, and measurements were made ten times each. Measurement results The CT-Dose phantom was measured at $30.44{\pm}0.31mGy$ in the periphery, $29.55{\pm}0.34mGy$ CTDIw value was measured at $30.14{\pm}0.30mGy$ in the center, and the phantom fabricated using the 3D printer was measured at the periphery $30.59{\pm}0.18mGy$, the central part was $29.01{\pm}0.04mGy$, and the CTDIw value was measured at $30.06{\pm}0.13mGy$. Analysis using the Mann - Whiteney U-test of the SPSS statistical program showed that there was a statistically significant difference in the result values in the central part, but statistically significant differences were observed between the peripheral part and CTDIw results I did not show. In conclusion, even in the CT-Dose phantom made with a 3D printer, we showed dose measurement performance like existing CT-Dose phantom and confirmed the possibility of low-cost phantom production using 3D printer through this research did it.

A Study on the Relationship among Skin Care Situations, Skin Care Recognition, and Skin Care Satisfaction by Gender in Medical Skin Care Center Patients: - Focused on Females and Males in Hainan Province, China-

  • Jia, Yue;Kim, Kyeong-Ran
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.6
    • /
    • pp.173-181
    • /
    • 2021
  • Chinese people have increasingly high interests in skin care and trust and prefer medical institution products and equipment to treat skin problems. The purpose of this study is to examine skin types and skin care situations, skin care recognition, and skin care satisfaction by gender in medical skin care center patients from in their 10s to 50s in Hainan Province, China. The questionnaire survey consisted of general characteristics(n=8), skin care situations(n=6), skin care recognition(n=11), and skin care satisfaction(n=21). A total of 328 questionnaires were researched from December 21, 2020 to January 9, 2021 using WeChat and Wenjuanxing program. Data were analyzed by SPSSWIN 21.0. Frequency analysis was applied for general characteristics, skin care situations, skin care recognition, and skin care satisfaction and Cronbach's α was used for the reliability of skin care recognition and satisfaction. The relationship among skin care situations, skin care recognition, and skin care satisfaction was analyzed by χ2 test and t-test. As a result, the common skin types by gender was dry skin in females and oily skin in males. The highest skin trouble was melasma and pigments in females and pimple in males. The most common way to manage troubled skin was homecare in both females and males, followed by the dermatology department in females and pharmacy in males, suggesting a significant difference. The common period of skin trouble was from one year to three years and the most effective way to improve skin was good life habit, followed by laser treatment in both females and males. The most important consideration to choose a hospital was a famous franchise hospital and the most important matters in management was doctor or skin care professionalism. Skin care and treatment recognition was high in external effects for females and internal effects for males. Skin care satisfaction was high in service for females and effect for males. Skin care satisfaction was significantly higher in males than in females. In conclusion, there was a difference in skin types, skin troubles, skin problems, skin care ways, and skin care satisfaction by gender in Chinese medical skin care center patients. Therefore, this study suggests the development of various products and the need of systematic management programs.

Evaluation of Extended Canine Semen after Different Filtration Treatment (개 희석 정액의 다양한 filtration 처리 후 정자평가)

  • Kim, Yong-Jun;Kim, Jin-Young;Kim, Sue-Hee;Lee, Young-Jun
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.577-583
    • /
    • 2007
  • It is important to obtain semen with good quality for efficient fertilization and pregnancy. To obtain these semen, various methods have been developed but most of these methods are time consuming and require costly equipment. Therefore, the objective of this research is to investigate the usability of column filtration system as quick and simple method to get sperm with better quality. Ejaculates were obtained from 5 dogs and analyzed with basic quality parameters before each filtration. Sperm concentration was adjusted to $5{\times}10^7/ml$ after dilution. The experimental groups were divided into non-filtered group(control) and filtered groups(glass wool, Sephadex 5% and Sephadex 20%). Ejaculates were filtered through each filter system and assessed by recovery rate of sperm, motility, normal morphology, CFDA/PI stain and plasma membrane integrity(hypo-osmotic swelling test, HOST). The lowest recovery rate of spermatozoa was recorded in glass wool filtration group, followed by 20% Sephadex filtration group(p<0.05). There was no significant difference between control(non-filtered) and 5% Sephadex filtration poop. Also, there was no significant difference of sperm motility assessed under light microscope among experimental groups. Morphological normality of canine spermatozoa was the highest in the glass wool filtration group and the lowest in the 5% Sephadex filtration group with no significant differences versus 20% Sephadex filtration and control group, respectively(p<0.05). Viability of canine sperm assessed by CFCA/PI staining was the highest in the glass wool filtration poop with no significant difference versus the control group, and the lowest in the 20% Sephadex filtration group with no significant difference versus 5% Sephadex filtration group, respectively(p<0.05). HOS values of canine sperm was the highest in the 20% Sephadex filtration group with no significant difference versus 5% Sephadex filtration group, and the lowest in the control poop with no significant difference versus glass wool filtration group, respectively(p<0.05). Therefore, these results indicated that filtration treatment for extended canine sperm would be useful method to get sperm with better quality by trapping the damaged sperm, consequently filter would be physical barrier against injured or immotile sperm.

A Study on the Creep Deformation Characteristic of AZ31 Mg Alloy at High Temperature (AZ3l 마그네슘 합금의 고온 크리이프 변형특성에 관한 연구)

  • An Jungo;Kang Daemi;Koo Yang;Sim Sungbo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.3
    • /
    • pp.186-192
    • /
    • 2005
  • The apparent activation energy Qc, the applied stress exponent n, and rupture life have been determined from creep test results of AZ31 Mg alloy over the temperature range of 200$^{\circ}C$ to 300$^{\circ}C$ and the stress range of 23.42 MPa to 93.59 MPa, respectively, in order to investigate the creep behavior. Constant load creep tests were carried out in the equipment including automatic temperature controller with data acquisition computer. At the temperature of $200^{\circ}C{\sim}220^{\circ}C$ and under the stress level of 62.43~93.59 MPa, and at around the temperature of $280^{\circ}C{\sim}300^{\circ}C$ and under the stress level of 23.42~39.00 MPa, the creep behavior obeyed a simple power-law relating steady state creep rate to applied stress and the activation energy fur the creep deformation was nearly equal to that of the self diffusion of Mg alloy including aluminum From the above results, at the temperature of $200^{\circ}C{\sim}220^{\circ}C$ the creep deformation for AZ31 Mg alloy seemed to be controlled by dislocation climb but controlled by dislocation glide at $280^{\circ}C{\sim}300^{\circ}C$ .And relationship beween rupture time and stress at around the temperature of $200^{\circ}C{\sim}220^{\circ}C$ and under the stress level of 62.43~93.59 MPa, and again at around the temperature of $280^{\circ}C{\sim}300^{\circ}C$ and under the stress level of 23.42~39.00 MPa, respectively, appeard as fullow; log$\sigma$=-0.18(T+460)(logtr+21)+5.92, log$\sigma$ = -0.25(T+460)(logtr+21)+8.02 Also relationship beween rupture time and steady state creep rate appears as follow; ln$\dot$ =-0.881ntr-2.45

Validity analysis of the social emotion model based on relation types in SNS (SNS 사용자의 관계유형에 따른 사회감성 모델의 타당화 분석)

  • Cha, Ye-Sool;Kim, Ji-Hye;Kim, Jong-Hwa;Kim, Song-Yi;Kim, Dong-Keun;Whang, Min-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.15 no.2
    • /
    • pp.283-296
    • /
    • 2012
  • The goal of this study is to determine the social emotion model as an emotion sharing relationship and information sharing relationship based on the user's relations at social networking services. 26 social emotions were extracted by verification of compliance among 92 different emotions collected from the literature survey. The survey on the 26 emotion words was verified to the similarity of social relation types to the Likert 7-points scale. The principal component analysis of the survey data determined 12 representative social emotions in the emotion sharing relation and 13 representative social emotions in the information sharing relation. Multidimensional scaling developed the two-dimensional social emotion model of emotion sharing relation and of information sharing relation based on online communication environment. Meanwhile, insignificant factors in the suggest social emotion models were removed by the structural equation modeling analysis, statistically. The test result of validity analysis demonstrated the fitness of social emotion models at emotion sharing relationships (CFI: .887, TLI: .885, RMSEA: .094), social emotion model of information sharing relationships (CFI: .917, TLI: .900, RMSEA : 0.050). In conclusion, this study presents two different social emotion models based on two different relation types. The findings of this study will provide not only a reference of evaluating social emotions in designing social networking services but also a direction of improving social emotions.

  • PDF

A Design and Implementation of Process Controller for BMW (Bacteria Mineral Water) Plant (비엠 활성수 플랜트의 공정제어기 설계 및 구현)

  • Lee, Sang-Yun
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.16 no.2
    • /
    • pp.74-82
    • /
    • 2015
  • In this study, a BMW plant process control system model which produces BMW is suggested and the BMW plant process controller with the following functions is developed. The first function is to operate the electronic overload relays to stop the blower for a certain period of time and to re-operate it again when the blower is overloaded. The second function is to close the motor operated valve automatically in case of power failure to prevent the circulation from the guided tank to the compost throwing tank and to block leak from the compost throwing tank due to the failure of ball valve. The third function is to transfer produced BMW from the concentration tank to 4 storage tanks for automatic managing of the BMW output. A device to measure the signal of the BMW plant process controller and a test equipment are developed. The designed BMW plant process controller is checked to see if it operates correctly according to the design specifications. The sequence control method based on BMW plant process controller is developed at a low cost in this study, so it is expected to bring improvements in the stability and the efficiency of system and to cause reductions in the operation and the management costs in the future.

A Design of Fire-Command Synchronous Satellite Pyrotechnic Circuit (점화 명령에 동조된 인공위성 파이로테크닉 회로 설계)

  • Koo, Ja Chun;Ra, Sung Woong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.81-92
    • /
    • 2013
  • The satellite includes many release mechanisms such as solar array deployment, antenna deployment, cover to protect contamination in scientific equipment, pyro value of the propulsion subsytem, and bypass device in Li-Ion cell module. A drive the initiators is a critical to the successful mission because the initiators of release mechanism driving by the pyrotechnic circuit is operated in single short. The pyrotechnic circuit has to provide switching network for safety. A typical switching network has defect consisting of high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit is required some form of power conditioning to reduce the peak power demanded from the bus if the initiators are to be fired from the main bus. This paper design a pyrotechnic circuit synchronized to the fire-command to activate the fire switch to overcome use high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit provides a current limited widow pulse for fire current synchronized to the fire-command to insure that fire switch will only carry the current but never switch it. The current limited widow pulse for fire current can be possible to use low current rating and light mass switch in switching network. The current limit function in the pyrotechnic circuit reduces supply voltage to initiator and provides the effect of power conditioning function to reduce peak bus power. The pyrotechnic circuit to apply satellite development on geostationary orbit is verified the function by test in development model.