• 제목/요약/키워드: Test-area method

검색결과 2,511건 처리시간 0.032초

건축기초에서의 매입말뚝 설계기준 및 사례 (Review of Design Guide and Case Study on Bored Prefabricated Piling Method in Architectural Building Foundation)

  • 이원제
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.549-558
    • /
    • 2008
  • Well known and widely used in urban area and limited installation condition, a low noise and vibration piling method which has being called Bored Prefabricated Piling Method was reviewed in terms of design guide, and introduced a few case as well. Among the areas being applied of that method, a structural guide of architectural foundation was reviewed and compared to civil engineering foundation area to provide wider information for the foundation engineers. With introducing a few case application including pile load testing review especially dynamic testing in normal building foundation work, engineers may have a useful information on the design and construction of the piling method even different engineering area. It may also make enhancement a view of foundation engineering knowledge to various pile foundation area.

  • PDF

방음벽 상단소음저감장치의 성능평가 방법에 관한 연구(3) - 시험 및 평가방법의 제안 - (Estimation Method of Noise Reducing Devices Installed on the Noise Barrier(3) - Suggestion of Test and Estimation Method -)

  • 김철환;장태순;강희만;전기성;김동준;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.496-499
    • /
    • 2008
  • The noise reducing devices installed on the noise barrier have been developed in many shapes and ways to reduce noise around road traffic areas. In this study, test and estimation method for the noise reducing device witch installed on the top of a noise barrier was suggested. For this, the authors have considered sound power flow around the device and sound pressure levels for the far field area. To estimate the area effect behind the barrier, area average of noise pressure level difference divided by two area, upper and bellow the sight-line. Comparing the attenuation difference of these areas, the tendency of noise reduction effect was studied according to type of noise reducing devices. Compared with noise shielding efficiency of the devices that using equivalent height of a simple barrier calculated by the SoundPlan, the commercial environment noise simulation software.

  • PDF

제수원공 설계를 위한 장기간 연속수수량 추정모형의 개발 - 중심유역을 중심으로 (A Developmont of Numerical Mo del on the Estimation of the Log-term Run-off for the Design of Riverheads Works -With Special Reference to Small and Medium Sijed Catchment Areas-)

  • 엄병현
    • 한국농공학회지
    • /
    • 제29권4호
    • /
    • pp.59-72
    • /
    • 1987
  • Although long-term runoff analysis is important as much as flood analysis in the design of water works, the technological level of the former is relatively lower than that of the latter. In this respect, the precise estimation model for the volume of successive runoff should he developed as soon as possible. Up to now, in Korea, Gajiyama's formula has been widely used in long-term runoff analysis, which has many problems in applying in real situation. On the other hand, in flood analysis, unit hydrograph method has been exclusively used. Therefore, this study aims at trying to apply unit hydrograph method in long-term runoff analysis for the betterment of its estimation. Four test catchment areas were selected ; Maesan area in Namlum river as a representative area of Han river system, Cheongju area in Musim river as one of Geum river system, Hwasun area in Hwasun river as one of Yongsan river system, and Supyung area in Geum river as one of Nakdong river system. In the analysis of unit hydrograph, seperation of effective rainfall was carried out firstly. Considering that effective rainfall and moisture condition of catchrnent area are inside and outside of a phenomenon respectively and the latter is not considered in the analysis, Initial base flow(qb)was selected as an index of moisture condition. At the same time, basic equation(Eq.7) was established, in which qb can take a role as a parameter in relating between cumulative rainfall(P) and cumulative loss of rainfall(Ld). Based on the above equation, computer program for estimation model of qbwas seperately developed according to the range of qb, Developed model was applied to measured hydrographs and hyetographs for total 10 years in 4 test areas and effective rainfall was estimated. Estimation precision of model was checked as shown in Tab- 6 and Fig.8. In the next stage, based on the estimated effective rainfall(R) and runoff(Qd), a runoff distribution ratio was calculated for each teat area using by computerised least square method and used in making unit hydrographs in each test area. Significance of induced hydrographs was tested by checking the relative errors between estimated and measured runoff volume(Tab-9, 10). According to the results, runoff estimation error by unit hydrograph itself was merely 2 or 3 %, but other 2 or 3 % of error proved to be transferred error in the seperation of effective rainfall. In this study, special attentioning point is that, in spite of different river systems and forest conditions of test areas, standardized unit hydrographs for them have very similar curve shape, which can be explained by having similar catchinent characteristics such as stream length, catchinent area, slope, and vegetation intensity. That fact should be treated as important factor ingeneralization of unit hydrograph method.

  • PDF

이암지역에 근입된 PRD강관말뚝의 지지력 보강 (Reinforcement for Bearing Capacity of PRD Steel Pile at Mudstone Area)

  • 공진영;강희진;천병식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1760-1769
    • /
    • 2007
  • The cut slope sliding which has been frequently encountered in Pohang area has been reported due to the rapid reduction of shear strength in mudstone after being exposed to the air. Mudstone has characteristics that it has high enough strength and stiffness in a dry condition, but the strength and stiffness decrease in a wet condition with groundwater infiltration. The case study in this paper shows that mudstone which had enough strength in a boring stage has lost the strength after installing PRD steel pipe pile inducing an insufficient bearing capacity, which has been ascertained by the static load test. Test construction has been performed to investigate the most favorable method for increasing a pile bearing capacity in mudstone with various methods such as MSG (Micro Silica Grouting) around the tip and side of a pile, the perimeter grouting combined with Micro pile reinforcement, and concrete filling after tip reinforcing grouting. From the test construction, MSG has been turned out to be the most favorable method for increasing a pile bearing capacity in mudstone, which has been confirmed by the static load test.

  • PDF

Test Results of Friction Factor for Round-Hole Roughness Surfaces in Closely Spaced Channel Flow of Water

  • Ha, Tae Woong
    • Journal of Mechanical Science and Technology
    • /
    • 제18권10호
    • /
    • pp.1849-1858
    • /
    • 2004
  • For examining friction-factor characteristics of round-hole pattern surfaces which are usually applied on damper seals, flat plate test apparatus is designed and fabricated. The measurement method of leakage and pressure distribution along round-hole pattern specimen with different hole area is described and a method for determining the Fanning friction factor is discussed. Results show that the round-hole pattern surfaces provide a much larger friction factor than smooth surface, and the friction factor vs. clearance behavior yields that the friction factor generally decreases as the clearance increases unlike the results of Nava's flat plate test. As the hole depth is decreased, the friction factor is increased, and maximum friction factor is obtained for 50% of hole area. Since the present experimental friction factor results show coincident characteristics with Moody's friction factor model, empirical friction factors for round-hole pattern surfaces are obtained by using the Moody's formula based on curve-fit of the experimental data. Results of Villasmil's 2D CFD simulation support the present experimental test result.

남녀 고등학생의 신체적 자아개념에 관한 연구 (A Study on Physical Self Concept Between Boys' and Girls' High School Students)

  • 최선하
    • 한국보건간호학회지
    • /
    • 제4권2호
    • /
    • pp.5-13
    • /
    • 1990
  • The purpose of this study was to investigate physical self concept between high school boys and girls and to find various factors affecting them. For the Survey, 331 respondents for boys and 347 for girls were randomly selected from one coeducational high school in Seoul, from May 16 to May 19, 1990. The instrument used in this questionaire survey method was a part of Won Shik Jung's Physical Self Concept Scale for measuring Self Concept, it's reliability was' Cronbach a = 0.718. For the analysis. descriptive statistics were used by calculating frequencies, percentages and mean scores. $X^2-test$, t-test, and analysis of variance were employed to test the differences and statistical significance. The relationship between physical self concept and area variables was analysed by use of Pearson's correlation coiefficients. For the examine of various factors affecting physical self concept, multiple stepwise regression method was employed. The results of this study are summarized as follows: 1. There was no significant difference in physical self concept between male and female students. 2. The scores of physical self concept among the students were negatively correlated with their academic year, even though statistical signification was not found. 3. Physical self concept was classified into two areas; health area and appearance area. There was no significant difference in health area between boys and girls. But, the difference of health area was significant in accordance with the academic years. That, the scores of the health area are dropped as academic year going up. 4. Significant relationship was revealed among health area, appearance area, and physical self concept. The correlation between health area and physical self concept was the highest relationship (r = 0.71) The main factors affecting the physical self concept were (1) father's educational background (2) year (3) number of brother (4) religion (5) father's age. 5. As academic year going up, the rate of counseling with parents are dropped. In conclusion, the result of the study indicate that, a person managed the school health and parents can help students to promote their physical, mental, and emotional health by means of health education and counseling.

  • PDF

망점색인쇄물의 분광측색법과 자극치직독측색법에 대한 비교분석 (Camparision and Analysis about the Weighted-Ordinate Colorimetric Method and the Direct Colorimetric Method of Halftone Dot Printing Colors)

  • 이상남
    • 한국인쇄학회지
    • /
    • 제6권1호
    • /
    • pp.13-39
    • /
    • 1988
  • Test colors are halftone dot printed at the rate of 10% halftone dot area by process inksblack, cyan, magenta and yellow ink. Reproduced colors are measured by the weighted-ordinate colorimetric method and the direct colorimetric method. The weighted-ordinate colorimetric method compare favorably with the direct colorimetric method, because the former has good regular changes of tristimuIus values, chromacity coordinates, excitation purities, value functions and has smaller errors of dominant and complementary wavelengths than the latter. All test colors classify with the Munsell renotation.tation.

  • PDF

전역방출방식 CO2 소화설비의 설계농도 및 유지시간 검증을 위한 직접방사실험에 관한 연구 (A Study on the Direct Discharge Test for Verifying Design Concentration and Soaking Time for CO2 Fire Extinguishing System of Total Flooding)

  • 이세명;문성웅;유상훈
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.15-23
    • /
    • 2012
  • $CO_2$ 소화설비의 소화성능 시험방법에는 직접시험방법이 가장 좋지만, 고비용과 환경문제 그리고 시험절차의 어려움으로 간접시험방법을 사용하는 경우가 많다. 그러나 석유화학플랜트나 원자력발전소와 같은 국가 중요위험시설은 화재가 발생하면 대형피해가 발생할 수 있으므로 직접방사시험을 통해 소화성능을 검증할 필요가 있다. 본 연구는 국가 중요위험시설에 설치된 전역방출방식의 $CO_2$ 소화설비 중에서 표면화재 방호구역과 심부화재 방호구역을 각각 선정하여 $CO_2$ 소화설비의 소화성능을 검증해 보았다. 소화성능은 방호구역 내에 방사된 $CO_2$의 농도가 설계농도기준(NFSC 및 NFPA)에 만족해야 그 성능을 인정받을 수 있다. 여기서, 설계농도는 $CO_2$ 소화약제가 화염을 제어할 수 있는 소화농도에 여유율 20 %를 감안한 농도를 의미한다. 시험결과 표면화재와 심부화재 방호구역 모두 $CO_2$ 설계농도를 확보하고 있음을 확인하였고 심부화재의 경우에는 20분 이상 설계농도가 유지되었다. 본 연구를 통해 국가 중요위험시설에 대한 직접방사시험 방법 및 판정방법을 소개하였고 향후 이와 같은 국가 중요위험시설에는 직접방사시험을 통해 소화설비의 신뢰성을 검증해야 할 필요성을 제기하였다.

형상의 이차미분을 이용한 비구면 형상측정기술 개발 (Development of Aspheric Surface Profilometry using 2nd Derivative)

  • 김병창
    • 한국기계가공학회지
    • /
    • 제10권2호
    • /
    • pp.104-109
    • /
    • 2011
  • I present a method of aspheric surface profile measurement using 2nd derivative of local area profile. This method is based on the principle of curvature sensor which measures the local 2nd derivative under test along a line. The profile is then reconstructed from the data on the each point. Unlike subaperture-stiching method and slope detection method, 2nd derivative method has strong points from a geometric point of view in measuring the aspheric surface profile. The second derivative terms of surface profile is an intrinsic property of the test piece, which is independent of its position and tip-tilt motion. The curvature is measured at every local area with high accuracy and high lateral resolution by using White-light scanning interferometry.

반응표면법을 사용한 자동차용 휠 베어링 시일의 형상 최적화 (Shape Optimization of an Automotive Wheel Bearing Seal Using the Response Surface Method)

  • 문형일;임종순;김헌영
    • 한국자동차공학회논문집
    • /
    • 제18권6호
    • /
    • pp.84-90
    • /
    • 2010
  • This paper presents the shape optimization process for the automotive wheel bearing seal lip using the finite element method and the response surface method. First, to predict performance of the bearing seal lip, we used the non-linear finite element analysis. And then, we compared the analysis results with the test results to verify the finite element model. The objective function in optimizing process was obtained from results of the mud slurry test, which is one of many tests for evaluating performance of wheel bearing. After the mud slurry test for the four models which have the similar cross-sectional shape, we measured the wear area of the seal lip and the moisture content in grease. The objective function has been chosen by comparing the results of mud slurry test and characteristics of seal lip, such as contact force, contact area, contact pressure, and interference. Finally, within limited design parameters, we suggested the optimized shape of seal lip, which is expected to improve the wear and the sealing effect of it.