매립지반의 팽이말뚝 평판재하시험 사례 연구 (Case Study Top-Base Foundation Static Loading Test in Reclaimed Land)

  • 신은철;김성환;이애영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.721-728
    • /
    • 2008
  • Top-Base Method is a stabilization method for light weight structures particularly in the soft ground. It is widely used for the increment of bearing capacity and the effect of restraining settlement when the bearing capacity of the ground is not enough. Top-shaped cone concrete foundations are installed in graveled laid over soft ground. The principle of the basic method is to maximize effect of dispersing the overburden pressure by increasing the contact area of the top-shaped cone. Therefore, the bearing capacity is increased and the settlement is decreased by the embedded resistance of pile part in the ground. In this paper, the plate bearing test was conducted to evaluate the feasibility of Top-Base foundation. Based on the test results, the coefficient of subgrade reaction, elastic modulus, and settlement of foundation on reclaimed land was derived.

  • PDF

Experimental validation of ASME strain-based seismic assessment methods using piping elbow test data

  • Jong-Min Lee ;Jae-Yoon Kim;Hyun-Seok Song ;Yun-Jae Kim ;Jin-Weon Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1616-1629
    • /
    • 2023
  • To quantify the conservatism of existing ASME strain-based evaluation methods for seismic loading, this paper presents very low cycle fatigue test data of elbows under various cyclic loading conditions and comparison of evaluation results with experimental failure cycles. For strain-based evaluation methods, the method presented in ASME BPVC CC N-900 and Sec. VIII are used. Predicted failure cycles are compared with experimental failure cycle to quantify the conservatism of evaluation methods. All methods give very conservative failure cycles. The CC N-900 method is the most conservative and prediction results are only ~0.5% of experimental data. For Sec. VIII method, the use of the option using code tensile properties gives ~3% of experimental data, and the use of the material-specific reduction of area can reduce conservatism but still gives ~15% of experimental data.

현장에서의 창의 차음성능 측정방법에 관한 실험적 연구 (An Experimental Study on the Field Measurement Methods of the Sound Insulation Performance of Window)

  • 이옥균;박현구;최형욱;송혁;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.600-605
    • /
    • 2000
  • The aim of this study is to compare the sound insulation performances of window depending on the measurement methods through the field test and analyze the factors that affect the sound insulation performances. Four measurement methods which are specified in the Koran Standard 2235 and the International Standard 140-5 were selected for the study; the outdoor sound source method which is classified the l000mm method and the 10mm method, the indoor sound source method, and the ISO method. The result of this study is that the sound insulation performance of the windows was the best when measured according to the ISO method and the worst the indoor sound source method. Through the study it was found that the main factors affecting the sound insulation performance of the windows were the correction of the specimen's area and the equivalent sound absorption area of the receiving room.

  • PDF

LTE Signal Propagation Model-based Fingerprint DB Generation for Positioning in Emergency Rescue Situation

  • Cho, Seong Yun
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제9권3호
    • /
    • pp.157-167
    • /
    • 2020
  • Fingerprinting method is useful when estimating the location of a requestor based on LTE signals in an urban area. To do this, it is necessary to acquire location-based signals everywhere in the service area for fingerprint DB generation in advance. However, there may be signal uncollected area within a wide service area, which may cause a problem that the positioning accuracy of the requestor is low. In order to solve this problem, in this paper, signal propagation modeling is performed based on the obtained measurements, and based on this model, the signal information in the non-acquisition region is estimated. To this end, techniques for modeling signal propagation according to a method using measurements are proposed. The performance of the proposed techniques is verified based on the measurements obtained on a test bed selected as Seocho-gu, Seoul. As a result, it can be seen that signal propagation modeling performed based on multidivision segmented measurements has the most performance improvement.

대형직접전단시험에 의한 RAP 복합지반의 전단강도 특성 연구 (A Study on the Shear Strength Characteristics of Composited Ground applying RAP Method by Large Direct Shear Test)

  • 천병식;서덕동;김종산
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2004년도 춘계학술발표회
    • /
    • pp.82-89
    • /
    • 2004
  • To secure stability and availability of Rammed Aggregate Pier method as the foundation of a structure, the shear strength characteristics according to the area replacement ratio of RAP and the relative density of in-situ ground was studied through soil laboratory tests and large direct shear tests in a model ground. As a result, the internal friction angle tends to increase in proportion to in-situ relative density(Very Loose, Loose, Medium) in composite ground formed by the same area replacement ratio of RAP and also increase in proportion to increasing the area replacement ratio(30, 40, 50%) of RAP in the same ground condition. Furthermore, the comparative analysis between the experimental value and theoretical value of the shear strength is carried out.

  • PDF

An Advanced Correlation Algorithm between GTEM and OATS for Radiated Emission Tests

  • Lee, Ae-Kyoung
    • ETRI Journal
    • /
    • 제17권3호
    • /
    • pp.45-63
    • /
    • 1995
  • This paper proposes an algorithm to improve the correlation between giga-hertz transverse electromagnetic (GTEM) cell and open area test site (OATS). It is based on the dipole modeling process of an unknown source object in a GTEM cell and on the evaluation of the approximate far field equations correlated with measured GTEM powers at output port of the GTEM cell. In this algorithm, the relative phase differences between dipole moments play an important part in modeling the test object as a set of dipoles and offer stable calculation of emission values. The radiated emission test using this algorithm requires fifteen orientations of equipment under test, but the increased orientations as compared with the previous method have little effect on the time needed for testing. Radiation from a notebook computer has been tested for statistical analysis of the correlation between GTEM data and OATS data. The emission test results of the notebook computer show that the mean, the standard deviation, and the correlation coefficient are -0.62, 1.99, and +0.85, respectively. These figures indicate that this algorithm provides improved accuracy in the measurement of electromagnetic emissions over the previous method.

  • PDF

CMOS 회로의 전류 테스팅를 위한 내장형 전류감지기 설계 (Design of a Built-in Current Sensor for Current Testing Method in CMOS VLSI)

  • 김강철;한석붕
    • 전자공학회논문지B
    • /
    • 제32B권11호
    • /
    • pp.1434-1444
    • /
    • 1995
  • Current test has recently been known to be a promising testing method in CMOS VLSI because conventional voltage test can not make sure of the complete detection of bridging, gate-oxide shorts, stuck-open faults and etc. This paper presents a new BIC(built-in current sensor) for the internal current test in CMOS logic circuit. A single phase clock is used in the BIC to reduce the control circuitry of it and to perform a self- testing for a faulty current. The BIC is designed to detect the faulty current at the end of the clock period, so that it can test the CUT(circuit under test) with much longer critical propagation delay time and larger area than conventional BICs. The circuit is composed of 18 devices and verified by using the SPICE simulator.

  • PDF

연성포장의 예방적 유지보수공법에 대한 현장 적용성 연구 (A Study on Field Application of Preventive Maintenance Method for Flexible Pavements)

  • 김낙석;진정훈
    • 대한토목학회논문집
    • /
    • 제31권4D호
    • /
    • pp.565-569
    • /
    • 2011
  • 본 연구는 예방적 유지보수공법의 한가지 방법으로서 최소단면 보수공법을 제안 하였다. 최소단면 보수공법은 아스팔트 포장도로의 종방향 파손(소성변형, 종방향 균열)에 대한 보수공법으로 차량의 주행특성을 통계적 분석으로 추론하여 최소 유효보수범위를 70cm로 산정하였으며, 포장도로의 파손 정도에 따라 유효보수범위 변화를 고려할 수 있을 것으로 판단되었다. 최소단면 보수공법의 현장 적용성을 시험하기 위하여 시험포장을 하였으며, 시험포장 결과 일정 수준의 공용성을 회복하는 것으로 나타났다. 향후, 본 최소단면 보수공법의 적절한 활용은 연성포장의 합리적 보수공법 중 한 가지가 될 수 있을 것으로 판단되며 연성 포장의 유지보수 및 관리에 대한 장기적 측면에서 볼 때 포장수명 연장과 유지보수비절감 효과가 있을 것으로 예상된다.

비행체 자동점검장비의 유지보수성 향상 방안 (Maintainability Improvement of Automatic Test Equipment for Aircraft)

  • 서민기;권기용;김성우;이성우
    • 한국항행학회논문지
    • /
    • 제21권5호
    • /
    • pp.508-513
    • /
    • 2017
  • 공학 용어로 유지보수성(maintainability)은 제품의 유지/관리에 대한 용이성을 의미한다. 비행체 자동점검장비(ATE)는 점검대상장비(UUT)의 기능/성능 특성에 따라 점검절차가 개발되기 때문에 UUT의 설계 변경에 많은 영향을 받는다. 더욱이 통합 ATE가 다수의 UUT를 점검하는 환경이라면 UUT 설계 변경에 대한 ATE의 유지보수가 쉽지 않다. 개발자는 ATE의 유지보수성 향상을 위하여 쉽고 명확한 개발 방식을 선정하여 개발 담당자의 변경에 유연하게 대처할 수 있어야 한다. 또한 UUT 설계 변경에 영향을 받는 영역을 특정 범위로 제한하여 수정될 부분을 최소화할 수 있어야 한다. 본 논문에서는 비행체 ATE 개발 과정을 기반으로 유지보수성 향상에 초점을 둔 ATE 개발 방안을 제안한다.

폐타이어 칩을 활용한 철도노반 동상저감에 대한 실험적 고찰 (Experimental Study about Reduction of Frost-heaving in Railway roadbed which using wasted tire chips)

  • 이승열;김영철;김남홍;김명수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.633-639
    • /
    • 2010
  • Cold area in korea, railway roadbed and gravel ballast was occurred frost-heaving. So during winter, track was rising and during thaw, track was sinking. In order to prevent the damage of frost-heaving, we have applied a few countermeasures which are circumfusion of calcium chloride and replacement of gravel ballast method. This countermeasures effect is feeble, not continuous and not eco-friendly. This study suggested that we use wasted tire-chips in frost-heaving area and considered appropriate new method to maintenance. This method was named "A Method of Wasted Tire-Chips Post". To prove effect of this method, we have tested in laboratory and field. The result of frost-heaving-ratio field test was decreased frost-heaving-ratio about 50% using "A Method of Wasted Tire-Chips Post".