• Title/Summary/Keyword: Test procedures

Search Result 1,857, Processing Time 0.029 seconds

Effect of steel fibres and nano silica on fracture properties of medium strength concrete

  • Murthy, A. Ramachandra;Ganesh, P.
    • Advances in concrete construction
    • /
    • v.7 no.3
    • /
    • pp.143-150
    • /
    • 2019
  • This study presents the fracture properties of nano modified medium strength concrete (MSC). The nano particle used in this study is nano silica which replaces cement about 1 and 2% by weight, and the micro steel fibers are added about 0.4% volume of concrete. In addition to fracture properties, mechanical properties, namely, compressive strength, split tensile strength, and flexural strength of nano modified MSC are studied. To ensure the durability of the MSC, durability studies such as rapid chloride penetration test, sorptivity test, and water absorption test have been carried out for the nano modified MSC. From the study, it is observed that significant performance improvement in nano modified MSC in terms of strength and durability which could be attributed due to the addition pozzolanic reaction and the filler effect of nano silica. The incorporation of nano silica increases the fracture energy about 30% for mix without nano silica. Also, size independent fracture energy is arrived using two popular methods, namely, RILEM work of fracture method with $P-{\delta}$ tail correction and boundary effect method. Both the methods resulted in nearly the same size-independent $G_F$ irrespective of the notch to depth ratio of the same specimen. This shows evidence that either of the two procedures could be used in practice for analysis of cracked concrete structures.

Numerical studies of the failure modes of ring-stiffened cylinders under hydrostatic pressure

  • Muttaqie, Teguh;Thang, Do Quang;Prabowo, Aditya Rio;Cho, Sang-Rai;Sohn, Jung Min
    • Structural Engineering and Mechanics
    • /
    • v.70 no.4
    • /
    • pp.431-443
    • /
    • 2019
  • The present paper illustrates a numerical investigation on the failure behaviour of ring-stiffened cylinder subjected to external hydrostatic pressure. The published test data of steel welded ring-stiffened cylinder are surveyed and collected. Eight test models are chosen for the verification of the modelling and FE analyses procedures. The imperfection as the consequences of the fabrication processes, such as initial geometric deformation and residual stresses due to welding and cold forming, which reduced the ultimate strength, are simulated. The results show that the collapse pressure and failure mode predicted by the nonlinear FE analyses agree acceptably with the experimental results. In addition, the failure mode parameter obtained from the characteristic pressure such as interframe buckling pressure known as local buckling pressure, overall buckling pressure, and yield pressure are also examined through the collected data and shows a good correlation. A parametric study is then conducted to confirm the failure progression as the basic parameters such as the shell radius, thickness, overall length of the compartment, and stiffener spacing are varied.

Development of 3-ch. Vibration Generator S/W for Virtual Test (가상시험을 위한 소프트웨어 기반 3채널 가진기 개발)

  • Kim, Kwang-Suk
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.1
    • /
    • pp.205-210
    • /
    • 2021
  • In this study, I studied how to generate input values to achieve the same value as the target value. The general procedures are explained to regenerate the excitation input, which is made by using the frequency response function between input-output. In this study, a mount model connected by a bushing was used as a numerical model. The response value for the excitation input was compared with the target value. The excitation input was corrected to obtain the same response as the target value. Through the iterative process, the reconstructed input value was obtained to have the same response as the test.

Risk Factors for Cardiac Implantable Electronic Device-Related Infections (이식형 심장 모니터링 장치 관련 감염의 위험요인)

  • Park, Jin Yeong;Choi, Hye-Ran
    • Journal of Korean Biological Nursing Science
    • /
    • v.23 no.4
    • /
    • pp.298-307
    • /
    • 2021
  • Purpose: This study aimed to investigate the risk factors for cardiac implantable electronic device (CIED)-related infections within the first post-procedural year after CIED insertion. Methods: This study included 509 adult patients undergoing CIED implantation procedures between January 1, 2011 and December 31, 2015. The data were analyzed by t-test, chi-square test, Fisher's exact test, and logistic regression analysis using SPSS/WIN 23.0. Results: Fifteen infections and 494 non-infections were examined. The CIED-related infection rate was 2.9%; patients with 14 pocket infections and one bacteremia were included in the CIED-related infection. The risk factors of CIED-related infections were the estimated glomerular filtration rate (eGFR) of ≤ 45 mL/min/1.73 m2 (Odds ratio [OR]= 4.03, 95% confidence interval [CI],1.15-14.10) and taking a new oral anticoagulant (NOAC) (OR = 4.50, 95% CI 1.09-18.55). Conclusion: These results identified the CIED infection rate and risk factors of CIED-related infection. It is necessary to consider these risk factors before the CIED implantation procedure and to establish the relevant nursing interventions.

Acute Myeloid Leukemia Identified Incidentally in Patient with Infected Extraction Socket through Preoperative Screening Blood Test: A Case Report

  • Yuha, Jeong;Minwoo, Kang;Shin Young, Hyun;Jong-Ki, Huh;Jae-Young, Kim
    • Journal of Korean Dental Science
    • /
    • v.15 no.2
    • /
    • pp.141-146
    • /
    • 2022
  • Leukemia is a neoplastic disease with an excessive proliferation of immature white blood cells and their precursors. Common oral manifestations of acute myeloid leukemia (AML) include ulceration, petechiae, spontaneous bleeding, and gingival hyperplasia. The estimated prevalence of AML is 19 per 100,000 populations, the median age of diagnosis is over 65 years, and of all the subtypes of leukemia, AML accounts for the highest percentage of leukemic deaths. The purpose of this study is to report the case of a 77-year-old female patient, who visited our outpatient clinic due to consistent inflammatory findings. Though she received surgical treatment, she was diagnosed with AML by chance after a preoperative blood test. We also discuss the necessity of performing a preoperative blood test prior to invasive dental procedures such as tooth extraction or biopsy.

A Study on the Subjectivity of Pre-Physical Education Teachers on the Track and Field Practical Skill Test of Examination System for Appointing Secondary Physical Education Teachers

  • Yu, Young-Seol
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.3
    • /
    • pp.127-135
    • /
    • 2022
  • The purpose of this study was to explore pre-physical education teachers' subjective perception on the athletics practical skill test of examination system for appointment secondary physical education teachers using Q-methodology. This study found three types of pre-teachers' subjective perception on the system. Type I is named 'the type of specialized facility support demand', Type II is named 'the type of professional technical guidance demand'. Type III is named 'the type of evaluation method improvement demand' In conclusion, the pre-physical education teachers hoped for the support of specialized facilities, the opportunity to receive professional skills, and the detailed preliminary guidance on evaluation methods and procedures.

A Study on the Sale Estimate Model of a Large-Scale Store in Korea (국내 대형점의 매출추정모델 설정 방안 연구)

  • Youn, Myoung-Kil;Kim, Jong-Jin;Park, Chul-Ju;Shim, Kyu-Yeol
    • Journal of Distribution Science
    • /
    • v.11 no.12
    • /
    • pp.5-11
    • /
    • 2013
  • Purpose - The purpose of this study was to construct a turnover estimation model by investigating research by Park et al. (2006) on the market area of domestic distribution. The study investigated distribution by using a new tool for the turnover estimation technique. This study developed and discussed the turnover estimation technique of Park et al. (2006), applying it to a large-scale retailer in "D"city that was suitable for on-the-spot distribution. It constructed the new model in accordance with test procedures keeping to this retail business location, to apply its procedures to a specific situation and improve the turn over estimation process. Further, it investigated the analysis and procedures of existing turnover estimation cases to provide problems and alternatives for turnover estimation for a large-scale retailer in "D"city. Finally, it also discussed problems and scope for further research. Research design, data, and methodology - This study was conducted on the basis of "virtue" studies. In other words, it took into account the special quality of the structure of Korea's trade zones. The researcher sought to verify a sale estimate model for use in a distribution industry's location. The main purpose was to enable the sale estimate model (that is, the individual model's presentation) to be practically used in real situations in Korea by supplementing processes and variables. Results - The sale estimate model is constructed, first, by conducting a data survey of the general trading area. Second, staying within the city's census of company operating areas, the city's total consumption expenditure is derived by applying the large-scale store index. Third, the probability of shopping is investigated. Fourth, the scale of sales is estimated using the process of singularity. The correct details need to be verified for the model construction and the new model will need to be a distinct sale estimate model, with this being a special quality for business conditions. This will need to be a subsequent research task. Conclusions - The study investigated, tested, and supplemented the turnover estimation model of Park et al. (2006) in a market area in South Korea. Supplementation of some procedures and variables could provide a turnover estimation model in South Korea that would be an independent model. The turnover estimation model is applied, first, by undertaking an investigation of the market area. Second, a census of the intercity market area is carried out to estimate the total consumption of the specific city. Consumption is estimated by applying indexes of large-scale retailers. Third, an investigation is undertaken on the probability of shopping. Fourth, the scale of turnover is estimated. Further studies should investigate each department as well as direct and indirect variables. The turnover estimation model should be tested to construct new models depending on the type of region and business. In-depth and careful discussion by researchers is also needed. An upgraded turnover estimation model could be developed for Korea's on-the-spot distribution.

A Study on Self Care Compliance Related to Infection Management for Continuous Ambulatory Peritoneal Dialysis Patients (복막투석환자의 감염예방과 관련된 자가간호 이행에 관한 연구)

  • Lee Eun-Young;Kim Jung-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.2
    • /
    • pp.313-323
    • /
    • 1998
  • This study was a descriptive research on the level of self-care available to continous ambulatory peritoneal dialysis patients (hereinafter referred to as 'CAPD patient') related to the specific area of infection management. The method employed for the collection of data was a modified instrument of the self-care survey essentially based on Young Sook Choi's instrument. The relevant data was collected from september 1, 1996 to september 30, 1996. The subjects were provided with an open-ended question regarding the reasons behind why they did not seek self-care. The answers provided about self-care compliance were analyzed by SPSS for frequency, percentage, mean, t-test, ANOVA. Reasons for non-compliance were analyzed by content analysis. The results of the study were as follows : 1. The percentage of patients engaging in self-care were according to the following self performed tasks : preparation of dialysis : 30.58 points Dialysate exchange procedures : 49.40 points - Two bag type : 50.50 points - Spike type : 48.80 points - Neo type : 48.90 points Catheter exit site care : 25.13 points More specifically, in relation to the preparation of dialysis as referred to above, those patients engaging in self care was relatively high with respect to the cleaning of the dialysis before use and for the preservation of peritosol. However, in dialysate exchange procedures, data revealed that those patients engaging in self-care are relatively low with respect to putting on a mask during the performance of peritosol exchange. Similary in peritosol exchange procedure and catheter exit care, low levels of self-care performance were found in the area of putting on a mask during the peritosol exchange procedures and catheter line testing procedures, respectively. 2. In general characteristics, there appeared to be no distinction in self-care compliance among CAPD patients. 3. The main reasons for non-compliance were based in the following factor : intellectual, attitude, enviromental surrounding and physical. As a result of the foregoing finding, nurses should provide adequate assistance to promote self-care compliance by CAPD patients by checking the preparation of dialysis, dialysate exchange procedure, and catheter exit site care which recieved low point in this research.

  • PDF

Studies on the Myofibrillar Proteins Part 2. New Procedure for Extraction of Regulatory Proteins from Myofibrils (근원섬유단백질에 관한 연구 (제2보) 근수축 조절단백질의 새로운 정제방법)

  • Yang, Ryung;Kim, Chul-Jai;Yu, Ju-Hyun;Lee, Hyuk-Sin;Cho, Young-Dong
    • Korean Journal of Food Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.199-208
    • /
    • 1974
  • An attempt was made to study on new method for the extraction of the regulatory proteins from myofibrils, and the procedures for the preparation of desensitized actomyosin and for complete extraction of troponin-tropomyosin complex were developed. When myofibrils were treated through the procedures developed in this study, actomyosin obtained had no Ca-sensitivity, indicating that Ca-sensitizing protein factor had been removed completely from myofibril. Consequently, it was concluded that the procedures developed in this study were convenient to test whether Ca-sensitizing proteins has been removed or not. When Mg-activated ATPase activity of myofibril were measured, the myofibrillar ATPase turned into the actomyosin type ATPase with the progress of the treatment. This result was interpreted to show that the regulatory proteins of the myofibril seems to play a cementing role on the structure of myofibril. When supernatant containing the regulatory proteins were fractionated with $(NH_4)_2SO_4$ saturation solution, regulatory proteins, ${\alpha}-actinin$ and troponia-tropomyosin complex, could be obtained and they showed their typical phyoislogical activity which modify the actin-myosin interaction. The amount of troponin-tropomyosin complex in myofibril was 72 mg per g myofibril. This result was in good agreement with the results reported by many investigators, and therefore it was concluded that our procedures for the extraction of troponin-tropomyosin complex were desirable to study on the quantitative analysis of troponin-tropomyosin complex.

  • PDF

Trends and Costs of External Electrical Bone Stimulators and Grafting Materials in Anterior Lumbar Interbody Fusion

  • D'Oro, Anthony;Buser, Zorica;Brodke, Darrel Scott;Park, Jong-Beom;Yoon, Sangwook Tim;Youssef, Jim Aimen;Meisel, Hans-Joerg;Radcliff, Kristen Emmanuel;Hsieh, Patrick;Wang, Jeffrey Chun
    • Asian Spine Journal
    • /
    • v.12 no.6
    • /
    • pp.973-980
    • /
    • 2018
  • Study Design: Retrospective review. Purpose: To identify the trends in stimulator use, pair those trends with various grafting materials, and determine the influence of stimulators on the risk of revision surgery. Overview of Literature: A large number of studies has reported beneficial effects of electromagnetic energy in healing long bone fractures. However, there are few clinical studies regarding the use of electrical stimulators in spinal fusion. Methods: We used insurance billing codes to identify patients with lumbar disc degeneration who underwent anterior lumbar interbody fusion (ALIF). Comparisons between patients who did and did not receive electrical stimulators following surgery were performed using logistic regression analysis, chi-square test, and odds ratio (OR) analysis. Results: Approximately 19% of the patients (495/2,613) received external stimulators following ALIF surgery. There was a slight increase in stimulator use from 2008 to 2014 (multi-level $R^2=0.08$, single-level $R^2=0.05$). Patients who underwent multi-level procedures were more likely to receive stimulators than patients who underwent single-level procedures (p<0.05; OR, 3.72; 95% confidence interval, 3.02-4.57). Grafting options associated with most frequent stimulator use were bone marrow aspirates (BMA) plus autograft or allograft for single-level and allograft alone for multi-level procedures. In both cohorts, patients treated with bone morphogenetic proteins were least likely to receive electrical stimulators (p<0.05). Patients who received stimulation generally had higher reimbursements. Concurrent posterior lumbar fusion (PLF) (ALIF+PLF) increased the likelihood of receiving stimulators (p<0.05). Patients who received electrical stimulators had similar revision rates as those who did not receive stimulation (p>0.05), except those in the multilevel ALIF+PLF cohort, wherein the patients who underwent stimulation had higher rates of revision surgery. Conclusions: Concurrent PLF or multi-level procedures increased patients' likelihood of receiving stimulators, however, the presence of comorbidities did not. Patients who received BMA plus autograft or allograft were more likely to receive stimulation. Patients with and without bone stimulators had similar rates of revision surgery.