Study on the Conformance Testing of Data Exchange between Transport Information Center and Terminal Equipment (교통정보센터와 단말기간 데이터교환 기술기준 적합성 시험에 관한 연구)

  • Lee, Sang-Hyun;Kim, Gyeong-Seok
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.5
    • /
    • pp.147-158
    • /
    • 2008
  • Recently, Intelligent Transportation System (ITS) has been actively developed and built since the Transportation System Efficiency Promotion Act was enacted. However, since mutual connection among transportation information systems was not considered, the integration of transportation information services did not occur. Accordingly, the Ministry of Land Transport and Maritime Affairs established and announced the technical standard on ITS. In this study, the conformance testing of the transportation information and communication system interface standard on data exchange between the Transportation Information Center and terminals was researched The test items were categorized as data request tests and data providing tests by analyzing the communication procedures specified in the standard. A detail testing scenario was created for each item. The test assessment was established based on the conformance of data exchange procedures and the accuracy of data packet messages. Under the established technical standard, the number of times that tests should be performed was thought set to 30 and the success rate was set to 95%. The purpose of this study is to help the ITS of Korea perform the integrated management of transportation information by researching methods for conformance testing on the technical standard on ITS.

  • PDF

Development of Safety Management Procedures for an Autonomous Navigation Element Technology Test (선박 자율운항 요소기술 시험을 위한 안전관리절차서 개발)

  • Woo, Donghan;Lee, In-Gyu;Im, Namkyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.566-573
    • /
    • 2021
  • In this study, safety management procedures were developed based on domestic and foreign guidelines and related maritime law to ensure the safe development and implementation of smart autonomous ship technology and Samsung Heavy Industry. The safety management procedure was developed according to the guidelines for (MASS) sea trials (MSC.1/Circ.1604, Annex: Interim guidelines for MASS trials), proposed by International Maritime Organization (IMO) for the relevant authorities and stakeholders of MASS to properly conduct tests of systems and infrastructure related to safety and environmental protection. The developed safety management procedure applies to the maritime demonstration test of a system applying autonomous navigation element technology mounted as a navigation aid on a ship operating under a watch system, while complying with the environmental protection and navigation safety of the coast of Korea.

Long-term Outcomes of Augmentation Cystoplasty in a Pediatric Population With Refractory Bladder Dysfunction: A 12-Year Follow-up Experience at Single Center

  • Mehmood, Shahbaz;Alhazmi, Hamdan;Al-Shayie, Mohammed;Althobity, Ahmed;Alshammari, Ahmed;Altaweel, Waleed Mohamed;Almathami, Ahmed;Vallasciani, Santiago
    • International Neurourology Journal
    • /
    • v.22 no.4
    • /
    • pp.287-294
    • /
    • 2018
  • Purpose: Augmentation cystoplasty (AC) is a surgical procedure used in adults and children with refractory bladder dysfunction, including a small bladder capacity and inadequate bladder compliance, and in whom conservative and medical treatment has failed. This study was aimed to determine the long-term outcomes of AC in children. Methods: A retrospective analysis was conducted of 42 patients (31 males; mean age, $14.2{\pm}6.2years$) who underwent AC for neurogenic and nonneurogenic bladder dysfunction, with a median $12.0{\pm}1.5years$ of follow-up. All patients underwent AC using the ileum with or without continent reconstruction. Pre-AC, concurrent, and post-AC procedures and complications were analyzed. Patients who underwent ureterocystoplasty, were lost to follow-up, or had less than 10 years of follow-up were excluded. The primary outcomes were the complication and continence rates, the post-AC linear rate of height and weight gain, and renal function. The Student t-test was used to evaluate between-group differences and the paired t-test was used to evaluate longitudinal changes in measured variables. Results: Renal function was stable or improved in 32 of 42 patients (76.2%), with a post-AC continence rate of 88.1%. Thirty patients (71.4%) required 72 procedures post-AC. There was no statistically significant difference in the mean percentile of height (P=0. 212) or weight (P=0.142) of patients in the pre- and post-AC periods. No cases of bladder perforation or malignancy were detected. Conclusions: We consider AC to be a safe and effective procedure that does not negatively affect future physical growth, while achieving a good rate of stable renal function. Patients need long-term follow-up to address long-term complications.

Patient satisfaction in shoulder arthroscopy: telemedicine versus clinic follow-up visits

  • Cha, Elliot D.K.;Suraci, Corey;Petrosky, Daniel;Welsh, Rebeca;Reynolds, Gustin;Scharf, Michael;Brutico, Joseph;SantaLucia, Gabriella;Choi, Joseph
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.2
    • /
    • pp.106-111
    • /
    • 2022
  • Background: The use of telemedicine for postoperative visits is increasing, especially in rural areas. Few studies have investigated its use for arthroscopic shoulder patients. This study aims to evaluate patient satisfaction with telemedicine for postoperative clinic visits following arthroscopic shoulder procedures in a rural setting. Methods: Patients were prospectively enrolled using the following exclusion criteria: <18 years, open procedures, and non-compliance follow-up at 6 weeks postoperatively. All patients completed a 13-question satisfaction survey, while telemedicine patients completed an additional, separate seven-question survey. Patients who switched groups completed a four-question prompt to determine the reasons for switching. Differences between groups were evaluated by either Student t-test or Mann-Whitney U-test. Results: The study enrolled 32 patients, with five patients following up by telemedicine and 27 in person. Age and distance from clinic were similar between patients who were assigned to the telemedicine group, completed the telemedicine visit, and opted for in-person visits (all p>0.05). Patient satisfaction did not vary significantly based on care by the surgeon, concerns being addressed, thoroughness of visit, overall clinical assessment at a prior visit, and improvements in pain and physical function (all p>0.05). Among patients who opted out of telemedicine visits, the most common reason was a preference to meet in-person but these patients agreed that telemedicine visits are a good idea. Conclusions: Regardless of type of follow-up, individuals reported similar levels of satisfaction with treatment during the visit and improvements in pain and physical function.

Comparison of clinical efficacy of ropivacaine and lignocaine with adrenaline for implant surgery anesthesia: a split-mouth randomized controlled clinical trial

  • Kalath, Remya Nath;Kulal, Rithesh;Gopinath, Sharika
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.21 no.4
    • /
    • pp.337-344
    • /
    • 2021
  • Background: The primary indication for using long-acting anesthetics in dentistry is extensive dental procedures that require pulpal anesthesia beyond 90 min and management of postoperative pain. Ropivacaine is an amide local anesthetic that is available at various concentrations with inherent vasoconstrictive properties at low concentrations. Ropivacaine has a 75% greater margin of safety than bupivacaine. Ropivacaine can be a good alternative to bupivacaine as a local anesthetic in dental implant surgery as it provides a longer duration of both pulpal and soft tissue anesthesia after mandibular nerve block and lowers CNS and cardiovascular toxicity. This study aimed to evaluate and compare the clinical efficacy of ropivacaine and lignocaine for implant surgery anesthesia. Methods: Fifteen patients with bilateral edentulous sites indicated for implant placement were recruited for this study. Patients aged 20-60 years of both sexes were randomly recruited. Thirty implant placements were performed in the test and control groups using ropivacaine and lignocaine with adrenaline as local anesthetics, respectively. Results: The results were analyzed statistically. The duration of anesthesia was significantly higher in the test group than in the control group. Ropivacaine was found to be superior to lignocaine in terms of the quality of anesthesia. The comparison of mean visual analog scale scores showed ropivacaine to have better anesthetic and analgesic effects than the control group. Conclusion: Ropivacaine 0.75% provides a significantly longer duration of anesthesia than lignocaine 2% with adrenaline. Ropivacaine 0.75% decreased intraoperative and postoperative analgesia compared to lignocaine 2% with adrenaline. Hence, ropivacaine 0.75% can be used as an alternative to lignocaine in implant surgeries and other intraoral surgical procedures that require a longer duration of anesthesia and analgesia.

Evaluation of blood clot, platelet-rich plasma, and platelet-rich fibrin-mediated regenerative endodontic procedures in teeth with periapical pathology: a CBCT study

  • Swati Markandey;Haridas Das Adhikari
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.4
    • /
    • pp.41.1-41.20
    • /
    • 2022
  • Objectives: This study compared the clinical and radiological outcomes of regenerative endodontic procedures (REPs) using blood clots (BCs), platelet-rich plasma (PRP), and platelet-rich fibrin (PRF) through intraoral periapical radiography (IOPAR) and cone-beam computed tomography (CBCT). Materials and Methods: Forty-five single-rooted necrotic teeth with periapical pathology were randomly allocated to receive BC, PRP, or PRF as an individual scaffold. Outcomes were evaluated in 35 teeth in 23 patients with a follow-up period of 12-24 months through qualitative IOPAR scoring and quantitative CBCT measurements. Healing of periapical lesions and in immature teeth, changes in the apical foramen diameter (AFD), root wall thickness (RWT), and root length (RL) were assessed. A p value less than 0.05 was considered to indicate statistical significance. Results: All teeth were asymptomatic except 1 in the PRP group. Periapical lesion healing was seen in all except 2 teeth in the BC group and 3 in the PRP group. Both IOPAR and CBCT revealed no significant differences in bone healing or changes in AFD, RWT, and RL among the 3 groups. A positive pulp sensibility response to the cold test was seen in 2 teeth in the BC group, but none to the electric pulp test. Intracanal calcification (ICC) was evident in more teeth in the BC group than in the PRP and PRF groups, and was also significantly higher in immature teeth. Conclusions: Our results revealed that BC, PRP, and PRF have similar potential as scaffolds in REPs, and ICC may be a concern for long-term outcomes.

A Study on Evaluation Method of the LKAS Test in Domestic Road Environment (국내도로환경을 고려한 LKAS 시험평가 방법에 관한 연구)

  • Yoon, Pil-Hwan;Lee, Seon-Bong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.628-637
    • /
    • 2017
  • The automobile industry has developed Advanced Driver Assistance Systems (ADASs) to prevent traffic accidents and reduce the burden for drivers. One example is the Lane Keeping Assistance System (LKAS), which was developed for automotive vehicle systems for safety and better driving. The main system of the LKAS supports the driver while maintaining the vehicle within a lane. LKAS uses a radar sensor and camera sensor to collect information about the vehicle's position in the lane and send commands to the actuator to influence the lateral movement of the vehicle if necessary. Recently, vehicles equipped with LKAS have become commercially available. Test procedures for international LKAS evaluation are being discussed and developed by international committees, such as the International Organization for Standardization and United Nations Economic Commission for Europe. In Korea, an evaluation of LKASs for car safety is being planned by the Korean New Car Assessment Program. Therefore, test procedures should be developed for LKASs that are suitable for the domestic road environment while accommodating international standards. We developed a test scenario for LKASs and propose a formula for obtaining the target relative distance. To validate the methods, a series of experiments were conducted using commercially available vehicles equipped with LKAS.

Flexual strength of resins for provisional fixed prostheses (임시 고정성 보철물 제작용 레진의 굽힘강도)

  • Choi, Myoung-Ah;Ahn, Seung-Geun;Cho, Kuk-Hyeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.3
    • /
    • pp.221-227
    • /
    • 2000
  • Provisional fixed partial dentures(FPDs) are an important part of many prosthodontic treatment procedures. These provisional fixed prostheses must fulfill biologic, mechanical, and esthetic requirements to be considered successful. Consideration of all these factors and requirements are important because provisional resin restorations may be worn over a long period to assess the results of periodontal and endodontics therapies, and also during the restorative phase of implant reconstructive procedures. This in vitro study examined flexual strength of four resins commonly used for fixed provisional prostheses. The effects of polymerization conditions were also evaluated. The four resins tested were : Caulk Temporary bridge resin(L.D. Caulk Co. Dentsply International Millford), Jet(Lang Dental Mfg. Co. Chicago. ILL. U.S.A), Alike (Coe Laboratories. Inc. Chicago. ILL. U.S.A) and Tokuso Curefast (Coe Laboratories. Inc. Chicago. ILL. U.S.A) The test specimens were 65mm long, 14mm wide, and 3.5mm thickness. 10 specimens of four resins were cured for 15 minutes at atmospheric pressure and 10 specimens of four resins were cured at an additional pressure of approximately 20 psi. A total of 80 specimens were prepared. The flexual strength was determined by three-point bending test. Data were analysed with the Paired samples T-test and Tukey student-range test Within the limitations imposed in this study, the following conclusions can be drawn : 1. Under the condition of bench curing, Caulk Temporary bridge resin showed the highest flexual strength. In decreasing order, the flexual strength of the other materials was as follows : Jet, Tokuso Curefast, Alike, and Caulk Temporary bridge resin demonstrated significantly higher strength than other resins. 2. Under the condition of pressure curing, Jet showed the highest flexual strength. In decreasing order, the flexual strength of the other materials was as follows : Caulk Temporary bridge resin, Tokuso Curefast, and Alike. There were all statistically significant differences among four resins 3. There was a statistically significant difference between bench- and pressure-cured specimens in all four materials.

  • PDF

Development of Designing and Performing Procedure for Well Test in Coalbed Methane(CBM) Reservoir (석탄층 메탄가스 저류층의 유정생산시험 설계 및 수행절차 수립연구)

  • Park, Jinyoung;Lee, Jeonghwan
    • Economic and Environmental Geology
    • /
    • v.46 no.4
    • /
    • pp.279-289
    • /
    • 2013
  • The most critical factor in developing coalbed methane(CBM) reservoir is absolute permeability. Both productivity and economics of the CBM depend on the absolute permeability. The methods to estimate it are core analysis and well test. However, absolute permeability determined by core analysis cannot be a good representative of CBM reservoir. Therefore, it is generally estimated by well test. In this study, well test methods applicable of CBM reservoir were classified with their characteristics. Merits and demerits of each well tests were also analyzed. Based on those parameters, design considerations and procedures of well test were derived. After each well tests was performed, the procedure of well test interpretations to estimate reservoir properties such as absolute permeability and skin factor was presented.

Some Remarks on Consistency Test of Add-on Test in Bioequivalence Trials (생물학적 동등성 시험에서 추가시험의 일관성 검정에 대한 소고)

  • Ha, Myoung-Ho;Park, Sang-Gue
    • Communications for Statistical Applications and Methods
    • /
    • v.19 no.1
    • /
    • pp.47-55
    • /
    • 2012
  • The newly revised bioequivalence guideline of Korea allows the add-on test since July 1, 2008 when the initial bioequivalence trial fails to show the equivalence of two drugs. The statistical model of the add-on test and its two stage testing procedures are discussed. Some statistical points of consistency test in the add-on test are considered and the issue on the sample size of add-on test is discussed. Some reasonable alternative like Japan's guideline for bioequivalence studies is recommended to secure the proper use of an add-on study through some simulation studies.