• Title/Summary/Keyword: Test procedures

Search Result 1,862, Processing Time 0.029 seconds

Field Validation of a Sampling and Analytical Method Developed for Preventing Airborne Hexavalent Chromium Collected on PVC Filter from Reduction (PVC 여과지에서의 환원 방지를 위해 개발된 공기중 6가 크롬 측정방법의 현장 평가)

  • 신용철;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.109-116
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of airborne hexavalent chromium, Cr(Ⅵ), in a field plating operation. The procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute iota Occupational Safety and Health (NIOSH) Method 7600, and the filler sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(Ⅵ) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(Ⅵ) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(Ⅵ) on PVC filters and storing the sample filters in strew-capped vials according to the NIOSH method, and analyzing Cr(Ⅵ) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(Ⅵ) into 0.02 M NaHCO₃ solution in midget impinger, and analyzing the Cr(Ⅵ) in samples using IC/VS. The third method was the OSHA Method ID-215. Using these four different methods, lour replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r²:0.99) between Cr(Ⅵ) concentrations measured by the Shin & Paik's Method and an impinger method (p>0.05). However, Cr(Ⅵ) concentrations determined by Shin & Paik's Method were significant1y different from those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(Ⅵ) concentrations of Shin & Paik's Method were significantly higher than those of the NIOSH/EPA Method or the OSHA method. This result indicated that the Shin & Paik's Method may prevent Cr(Ⅵ) losses caused by reduction and give more reliable results of airborne Cr(Ⅵ) concentrations in work environments.

IN VIVO STUDY ON ABUTMENT TOOTH MOVEMENT FOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURES (유리단 국소의치의 지대치 운동에 관한 생체학적 연구)

  • Lee, Jong-Yeop;Kim, Kwang-Nam;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.43-61
    • /
    • 1990
  • The laser reflexion method is a new technique which permits precise contactless measurement and observation of tooth mobility as well as tooth movement. The purposes of this study were to clarify the reliability of the laser reflexion method in clinical application and to measure the abutment tooth movement according to clasp design. This study was designed to determine 1) How much a bending movement of the impression plate stand affects the position of the reflexion pattern and how precise the patient bites into plate 2) Which clasp design causes greater movement of the abutment tooth. Under medium and maximum bite forces, tests were performed on central loading position which was 13mm distal to terminal abutment tooth of distal extension removable partial denture. The movement in the mesiodistal and buccolingual directions was measured. The Duncan's New Multiple-Range test was used to compare the means for the four castings under each direction-load combination; and the paired sample t-test was for medium and maximum bite forces. From this experiment, the following results were obtained. 1. The Roach clasp, the combination clasp, the RPI clasp, and the Akers clasp did not significantly differ in their effects on buccolingual movement of the abutment tooth. 2. The direction of abutment tooth movement was not significantly altered by clasp design and all abutment tooth movements were oriented distobuccally. 3. Under medium bite force, the Akers clasp caused greater distal movement of the abutment tooth than did the combination clasp and the RPI clasp. Under maximum bite force, the Akers clasp caused greater distal movement of the abutment tooth than did the RPI clasp. 4. The testing apparatus and procedures used in this study(laser reflexion method) proved to be reliable in clinical application.

  • PDF

Limited Impact of Music Therapy on Patient Anxiety with the Large Loop Excision of Transformation Zone Procedure - a Randomized Controlled Trial

  • Kongsawatvorakul, Chompunoot;Charakorn, Chuenkamon;Paiwattananupant, Krissada;Lekskul, Navamol;Rattanasiri, Sasivimol;Lertkhachonsuk, Arb-Aroon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.6
    • /
    • pp.2853-2856
    • /
    • 2016
  • Background: Many studies have pointed to strategies to cope with patient anxiety in colposcopy. Evidence shows that patients experienced considerable distress with the large loop excision of transformation zone (LLETZ) procedure and suitable interventions should be introduced to reduce anxiety. This study aimed to investigate the effects of music therapy in patients undergoing LLETZ. Materials and Methods: A randomized controlled trial was conducted with patients undergoing LLETZ performed under local anesthesia in an out patient setting at Ramathibodi Hospital, Bangkok, Thailand, from February 2015 to January 2016. After informed consent and demographic data were obtained, we assessed the anxiety level using State Anxiety Inventory pre and post procedures. Music group patients listened to classical songs through headphones, while the control group received the standard care. Pain score was evaluated with a visual analog scale (VAS). Statistical analysis was conducted using Pearson Chi-square, Fisher's Exact test and T-Test and p-values less than 0.05 were considered statistically significant. Results: A total of 73 patients were enrolled and randomized, resulting in 36 women in the music group and 37 women in the non-music control group. The preoperative mean anxiety score was higher in the music group (46.8 VS 45.8 points). The postoperative mean anxiety scores in the music and the non-music groups were 38.7 and 41.3 points, respectively. VAS was lower in music group (2.55 VS 3.33). The percent change of anxiety was greater in the music group, although there was no significant difference between two groups. Conclusions: Music therapy did not significantly reduce anxiety in patients undergoing the LLETZ procedure. However, different interventions should be developed to ease the patients' apprehension during this procedure.

Diagnostic Evaluation of Serum FSH and LH in Primary Amenorrhea by Radioimmunoassay (방사성 면역측정상의 혈청 FSH와 LH에 관한 일차성 무월경증 환자의 진단적 고찰)

  • Hong, I.S.;Kim, G.E.;Yoo, H.S.;Lee, J.T.;Park, C.Y.;Ryu, K.J.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.1
    • /
    • pp.37-44
    • /
    • 1980
  • The usefulness of single, random measurements of serum FSH and LH in the diagnosis of primary amenorrhea by radioimmunoassay was investigated. The 16 patients were divided into 3 groups by the level of serum FSH and LH. The first group with increased level of serum FSH and LH is five patients, all of these are related to the acquired or congenital abnormality of the ovary. Further studies indicated include buccal smear, chromosome analysis, gynecography and laparosocopy. The second group with normal serum FSH and LH is nine patients, four patients of these are related to the developmental anomaly of the Mullerian duct and five patients are undo etermined origin. Further studies indicated include laparoscopy and gynecography. The third group with decreased serum FSH and normal or decreased serum LH is two patients, one of these is related to the pituitary function, isolated FSH deficiency, the other is undetermined origin. Further studies indicated include the pituitary function test, LH-RH stimulation test, skull radiography. Determination of serum FSH and LH levels does not permit a specific etiologic diagnosis of primary amenorrhea. However the serum levels of FSH and LH can be used to differentiate the principal area of the investigation and can be of assistance in choosing more specific testing procedures.

  • PDF

Factors Influencing Genetic Change for Milk Yield within Farms in Central Thailand

  • Sarakul, M.;Koonawootrittriron, S.;Elzo, M.A.;Suwanasopee, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.8
    • /
    • pp.1031-1040
    • /
    • 2011
  • The objective of this study was to characterize factors influencing genetic improvement of dairy cattle for milk production at farm level. Data were accumulated from 305-day milk yields and pedigree information from 1,921 first-lactation dairy cows that calved from 1990 to 2007 on 161 farms in Central Thailand. Variance components were estimated using average information restricted maximum likelihood procedures. Animal breeding values were predicted by an animal model that contained herd-year-season, calving age, and regression additive genetic group as fixed effects, and cow and residual as random effects. Estimated breeding values from cows that calved in a particular month were used to estimate genetic trends for each individual farm. Within-farm genetic trends (b, regression coefficient of farm milk production per month) were used to classify farms into 3 groups: i) farms with negative genetic trend (b<-0.5 kg/mo), ii) farms with no genetic trend (-0.5 kg/$mo{\leq}b{\leq}0.5$ kg/mo), and iii) farms with positive genetic trend (b>0.5 kg/mo). Questionnaires were used to gather information from individual farmers on educational background, herd characteristics, farm management, decision making practices, and opinion on dairy farming. Farmer's responses to the questionnaire were used to test the association between these factors and farm groups using Fisher's exact test. Estimated genetic trend for the complete population was $0.29{\pm}1.02$ kg/year for cows. At farm level, most farms (40%) had positive genetic trend ($0.63{\pm}4.67$ to $230.79{\pm}166.63$ kg/mo) followed by farms with negative genetic trend (35%; $-173.68{\pm}39.63$ to $-0.62{\pm}2.57$ kg/mo) and those with no genetic trend (25%; $-0.52{\pm}3.52$ to $0.55{\pm}2.68$ kg/mo). Except for educational background (p<0.05), all other factors were not significantly associated with farm group.

Reliability Verification of Secured V2X Communication for Cooperative Automated Driving (자율협력주행을 위한 V2X 보안통신의 신뢰성 검증)

  • Jung, Han-gyun;Lim, Ki-taeg;Shin, Dae-kyo;Yoon, Sang-hun;Jin, Seong-keun;Jang, Soo-hyun;Kwak, Jae-min
    • Journal of Advanced Navigation Technology
    • /
    • v.22 no.5
    • /
    • pp.391-399
    • /
    • 2018
  • V2X communication is a technology in which a vehicle exchanges information with various entities such as other vehicles, infrastructure, networks, pedestrians, etc. through a wired or wireless network. Recently, V2X communication technology has been steadily developed and recently it has played an important role in autonomous cooperation driving technology combined with autonomous vehicle technology. Autonomous vehicles can utilize the external information received via V2X communication to extend the recognition range of existing sensors and to support more safe and natural autonomous driving. In order to operate these autonomous cooperative vehicles on public roads, the security and reliability of autonomous V2X communication should be verified in advance. In this paper, we present test scenarios and test procedures of secure V2X communication for cooperative automated driving and present verification results.

Analysis of Insulation Quality in Large Generator Stator Windings

  • Kim, Hee-Dong;Kong, Tae-Sik;Ju, Young-Ho;Kim, Byong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.384-390
    • /
    • 2011
  • To evaluate the condition of stator winding insulation in generators that have been operated for a long period of time, diagnostic tests were performed on the stator bars of a 500 MW, 22 kV generator under accelerated thermal and electrical aging procedures. The tests included measurements of AC current (${\Delta}I$), dissipation factor ($tan{\delta}$), partial discharge (PD) magnitude, and capacitance (C). In addition, the AC current test was performed on the stator winding of a 350 MW, 24 kV generator under operation to confirm insulation deterioration. The values of ${\Delta}I$, ${\Delta}tan{\delta}$, and PD magnitude in one stator bar indicated serious insulation deterioration. In another stator bar, the ${\Delta}I$ measurements showed that the insulation was in good condition, whereas the values of ${\Delta}tan{\delta}$ and PD magnitude indicated an incipient stage of insulation deterioration. Measurements of ${\Delta}I$ and PD magnitude in all three phases (A, B, C) of the remaining generator stator windings showed that they were in good condition, although the ${\Delta}tan{\delta}$ measurements suggested that the condition of the insulation should be monitored carefully. Overall analysis of the results suggested that the generator stator windings were in good condition. The patterns of PD magnitude in all three phases (A, B, C) were attributed to internal discharge.

Effectiveness Analysis and Profile Design Automation Tool Implementation for The Mass Production Weapon System Environmental Stress Screening Test (양산 무기체계 환경 부하 선별 시험 효과도 분석 및 프로파일 설계 자동화 도구 구현)

  • Kim, Jang-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.379-388
    • /
    • 2016
  • There are various system defects from weapons manufacturing due to the numerous production processes and various production environments. The first kind of defect is patent defects, which can be detected by visual inspection, functional testing, and existing quality control procedures during the manufacturing process. The second kind is latent defects, which cannot be detected though existing quality management approaches because of the complexity of the system and manufacturing process. To minimize the initial defect problems, environmental stress screening (ESS) is needed to detect the defects, remove them, and improve the product conditions based on the environmental stress conditions of temperature and vibration. We implemented a tool for quantitative ESS effectiveness analysis and profile design automation based on MIL-HDBK-344 and verified it using six scenarios with different temperature stress, vibration stress, and test designs.

Glomus Tumor of the Hand

  • Lee, Won;Kwon, Soon Beom;Cho, Sang Hun;Eo, Su Rak;Kwon, Chan
    • Archives of Plastic Surgery
    • /
    • v.42 no.3
    • /
    • pp.295-301
    • /
    • 2015
  • Background Glomus tumors were first described by Wood in 1812 as painful subcutaneous tubercles. It is an uncommon benign neoplasm involving the glomus body, an apparatus that involves in thermoregulation of cutaneous microvasculature. Glomus tumor constitutes 1%-5% of all hand tumors. It usually occurs at the subungual region and more commonly in aged women. Its classical clinical triad consists of pain, tenderness and temperature intolerance, especially cold sensitivity. This study reviews 15 cases of glomus tumor which were analyzed according to its anatomic location, surgical approach and histologic findings. Methods Fifteen patients with subungual glomus tumors of the hand operated on between January 2006 and March 2013, were retrospectively reviewed. Patients were evaluated preoperatively with standard physical examination including ice cube test and Love's test. Diagnostic imaging consisted of ultrasonography, computed tomography, and magnetic resonance imaging. All procedures were performed with tourniquet control under local anesthesia. Eleven patients underwent excision using the transungual approach, 3 patients using the volar approach and 1 patient using the lateral subperiosteal approach. Results Total of 15 cases were reviewed. 11 tumors were located in the nail bed, 3 in the volar pulp and 1 in the radial aspect of the finger tip. After complete excision, patients remained asymptomatic in the immediate postoperative period. In the long term follow up, patients exhibited excellent cosmetic results with no recurrence. Conclusions Accurate diagnosis should be made by physical, radiologic and pathologic examinations. Preoperative localization and complete extirpation is essential in preventing recurrence and subsequent nail deformity.

Bacterial Contamination and Disinfection Status of Laryngoscopes Stored in Emergency Crash Carts

  • Choi, Jae Hyung;Cho, Young Soon;Lee, Jung Won;Shin, Hee Bong;Lee, In Kyung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.50 no.3
    • /
    • pp.158-164
    • /
    • 2017
  • Objectives: To identify bacterial contamination rates of laryngoscope blades and handles stored in emergency crash carts by hospital and area according to the frequency of intubation attempts. Methods: One hundred forty-eight handles and 71 blades deemed ready for patient use from two tertiary hospitals were sampled with sterile swabs using a standardized rolling technique. Samples were considered negative (not contaminated) if no colonies were present on the blood agar plate after an 18-hour incubation period. Samples were stratified by hospital and according to the frequency of intubation attempts (10 attempts per year) using the ${\chi}^2-test$ and Fisher exact test. Results: One or more species of bacteria were isolated from 4 (5.6%) handle tops, 20 (28.2%) handles with knurled surfaces, and 27 (18.2%) blades. No significant differences were found in microbial contamination levels on the handle tops and blades between the two hospitals and two areas according to the frequency of intubation attempts. However, significant differences were found between the two hospitals and two areas in the level of microbial contamination on the handles with knurled surfaces (p<0.05). Conclusions: Protocols and policies must be reviewed to standardize procedures to clean and disinfect laryngoscope blades and handles; handles should be re-designed to eliminate points of contact with the blade; and single-use, one-piece laryngoscopes should be introduced.