• 제목/요약/키워드: Test method of performance

검색결과 5,825건 처리시간 0.04초

초음파검사자 기량검증 체제를 위한 다자비교시험 (Round Robin Test for Performance Demonstration System of Ultrasonic Examination Personnel)

  • 윤병식;양승한;김영호;김용식;양동순
    • 비파괴검사학회지
    • /
    • 제24권4호
    • /
    • pp.378-383
    • /
    • 2004
  • 국내 원자력발전소의 Class1과 Class2 배관검사에 적용할 수 있는 초음파탐상 검사자, 장비 그리고 절차서에 대한 한국형 기량검증(KPD) 시스템을 구축하였다. PD 방법을 적용한 검사결과와 전통적인 dB-drop 방법을 이용한 검사결과를 상호 비교하기 위하여 Round Robin Test(RRT)를 수행하였다. RRT 결과는 PD 방법의 신뢰성이 dB Drop 방법보다 우수한 것으로 나타났다. 이러한 결과로부터 원자력발전소 가동중검사에 PD 방법을 적용함으로써 초음파탐상검사 결과의 신뢰성이 더욱 향상될 것으로 기대된다.

통신기반 열차제어시스템 성능평가용 계측시스템 구현 및 적용 (Implementation & Application of Instrumentation System on Performance Evaluation for Korea-Radio Train Control System)

  • 이재호;이강미;박평식
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1777-1783
    • /
    • 2013
  • This study aims to implement an instrumentation system measuring and analysing real-time data of information flow between respective subunits composing train control system as the performance evaluation method for wireless communication based urban railway train control system under development for a Korean model. It analyses system functional requirements regarding subsystems composing wireless communication based train control system and test items for functions presented in each specification and examines data and measurement point for measuring according to test items in order to implement an instrumentation system. And, it clearly defines requirements of an instrumentation system to avoid malfunction or error in operation of train control system. It reviews data processing method and display method for effective analysis of data flow between respective subunits with measured data, designs and makes an instrumentation system. Ultimately, it applies to a performance test of train control system and makes sure an instrumentation system in normal working order.

FMEA를 활용한 재제조 파워스티어링 오일펌프 시험법에 대한 최적화 연구 (The Optimization Study on the Test Method of Remanufactured Power Steering Oil Pump by Using FMEA)

  • 서영교;정도현;유상석;나완용
    • 한국자동차공학회논문집
    • /
    • 제24권1호
    • /
    • pp.90-98
    • /
    • 2016
  • Currently government certified test method for an automobile remanufactured products is insufficient. Thus many automotive parts in the remanufacturing market are lacking proper evaluation criteria and production of defective products are causing customer dissatisfaction. In this paper a power steering oil pump, which requires stringent manufacturing standards, is studied by the failure mode and effect analysis approach. The research suggested that the test criteria such as discharge flow characteristic test, tightness test, pulley run-out test, pressure switch operation test, low temperature test and rotation pressure durability test should be performed to evaluate the reliability of remanufactured power steering oil pumps. As a result of tests, the performance of remanufactured power steering oil pump satisfied the evaluation criteria of pressure switch operation test and low temperature test. However, the remanufactured power steering oil pump failed to satisfy the evaluation criteria on discharge performance test, tightness test and pulley run-out test. These performance evaluation tests proved the necessity of standard process for the remanufactured power steering oil pump.

공기청정기 CA 규격성능시험 결과 분석 및 가스시험 변별력 향상 방안연구 (Analysis of CA Certification Performance Test Results and Improvement of CA Test Method for a Better Differentiation of Gas Removal Performances for Room Air Cleaners)

  • 김학준;한방우;김용진;차성일
    • 한국입자에어로졸학회지
    • /
    • 제7권3호
    • /
    • pp.87-97
    • /
    • 2011
  • In this study, we organized the test results obtained from the performance tests for the CA certificated air cleaners which had been commercially available in Korea since 2003, and analyzed the correlation among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level etc. The noise level of 267 air cleaners were increased as concentrated at the 45, 50, 55 dB, which are the required noise level for CA certification according to flow rate, and ozone emissions from the CA air cleaners were significantly lower than the requirement limit, 50 ppb for 24 hour operation. The average particle collection efficiency and odor removal efficiency were 89.3 and 80.8%, approximately 20% higher than the requirement of CA certification, regardless of flow rates. The particle removal performance of an air cleaner was clearly discriminated by its CADR, and the CADR was obtained with a simple calculation: 0.79 x flow rate. The low differentiation of gas removal performance of air cleaners by the current CA gas test method was improved by 3.2, 751.3, 13.4 times for ammonia, acetic acid, respectively, by adopting the CADR concept and the real time measurement method, FTIR, for gas removal performance test.

스마트공장 도입의 효과에 영향을 주는 요인들 (Factors Influencing Impact of Smart Factory Adoption)

  • 김선우;오정석
    • 서비스연구
    • /
    • 제13권1호
    • /
    • pp.1-26
    • /
    • 2023
  • 본 연구는 스마트공장 도입의 효과와 관련 요인을 분석하였다. 이를 위해 도입기업과 비도입기업의 표본 데이터를 median-size-industry matching method로 각각 110개, 325개를 수집했다. 도입 전년부터 도입 후 4년도까지 재무제표 데이터(ROA 등)를 활용했는데 event study method에 따른 abnormal operating performance, annual abnormal changes를 구한 뒤 Wilcoxon signed-rank test와 t-test로 분석했다. ROA와 매출증가율은 도입 후 단기적인 효과가 나타났으나 장기적으로 이어지지는 않았다. 또한 도입효과에 인력비중, 연구개발 수준, 이전 재무 성과 세 가지 요인이 조절효과로 영향이 있는지 회귀분석을 한 결과 연구개발 수준과 이전 재무 성과의 조절효과를 확인했다. 도입 효과에 도입시기의 영향과 이와 관련된 요인으로 이전 재무 성과와 기업규모의 조절효과가 있는지 회귀분석을 한 결과 장기에 도입시기가 늦을수록 도입효과가 더 커졌고, 이전 재무 성과와 기업규모의 조절효과를 확인했다.

외부마감재가 부착된 볼트접합 방식 패널링 시스템의 내진성능평가를 위한 진동대 실험 (Shake Table Test on Seismic Performance Evaluation of the Bolted Connection Type Paneling System with Exterior Finish Material)

  • 오상훈;박종원;박해용
    • 한국지진공학회논문집
    • /
    • 제22권1호
    • /
    • pp.23-32
    • /
    • 2018
  • In this study, we conducted a shake table test to verify the seismic performance of the paneling system with steel truss composed of bolt connections. The control group was set to the traditional paneling system with steel truss connected by spot welding method. Test results showed that the bolted connection type paneling system has excellent deformation capacity without cracking or brittle fracture of the steel truss connection parts compared to the welding type paneling system. Furthermore, in the bolted connection type, slight damage occurred at the time of occurrence of the same story drift angle as compared with the existing method, it is considered that it has excellent seismic performance. In compliance with the performance-based design recommended for the current code (ASCE 41-13) on non-structural components, it is judged that in the case of the bolted connection type paneling system, it can be applied to all risk category structures without restriction. However, in the case of traditional paneling system with spot welding method, it is considered that it can be applied limitedly.

유럽과 한국의 이륜차 엔진 성능 시험 규정에 대한 비교 연구 (A Comparison Study on the Engine Performance Test Regulation of Two-wheeled Vehicles between EU and Korea)

  • 이광구;용기중
    • 자동차안전학회지
    • /
    • 제8권3호
    • /
    • pp.22-27
    • /
    • 2016
  • As a preliminary research to provide amendment for the engine performance test regulation of two-wheeled vehicles, the engine performance data are investigated in terms of maximum torque, rated power, and engine speed of motorcycles on sales in Korean market. Based on the engine performance database officially published to consumers, some forecasted problems are discussed when the maximum torque and the rated power are measured under the present test standards. EU and Korea regulations on engine performance test are carefully compared in terms of the accuracy of measurement devices, test procedures including data acquisition method, and allowable range of rated power measurement. Complementary items are discussed to eliminate ambiguities in the present regulation and to construct rational regulation system.

Hybrid mesh 및 sliding mesh를 이용한 선박 저항추진 성능 시험 (SHIP RESISTANCE AND PROPULSION PERFORMANCE TEST USING HYBRID MESH AND SLIDING MESH)

  • 이주현;박범진;이신형
    • 한국전산유체공학회지
    • /
    • 제15권1호
    • /
    • pp.81-87
    • /
    • 2010
  • In this study, we conducted resistance and propulsion performance test of ship composed of the Resistance Test, Propeller Open Water Test and Self Propulsion Test using the CFD(Computational Fluid Dynamics). We used commercial RANS(Reynolds Averaged Navier Stokes equation) solver, as a calculating tool. The unstructured grids were used in a bow and stern of ship, having complex shape, for a convenience of generating grids, and the structured grids were adopted in a central hull and rest of hull having a relatively simple shape which is called hybrid grid method. In addition, The sliding mesh method was adopted to rotate a propeller directly in the Propeller Open Water and Self Propulsion Test. The Resistance Test and Self Propulsion Test were calculated using Volume of Fluid (VOF) model and considering a free surface. And all The three cases were applied realizable k-epsilon model as the turbulence model. The results of calculations were verified for the suitability of calculations by comparing MOERI's EFD results.

An experimental study on the development and verification of NCC(new concrete cutting) system

  • Park, Jong-Hyup;Han, Jong-Wook
    • Structural Engineering and Mechanics
    • /
    • 제65권2호
    • /
    • pp.203-211
    • /
    • 2018
  • This paper introduces the development process of NCC(New Concrete Cutting) system and analyzes first verification test. Based on the first verification test results, some problems of NCC system have been newly modified. We carry out the second verification test. We tried to verify cutting performance and dust control efficiency of NCC system through the cutting test of concrete bridge piers. In particular, this verification test strives to solve the problem of concrete dust, which is the biggest problem of dry cutting method. The remaining dust problems in cutting section tried to solve through this verification test. This verification test of the NCC system shows that the dust problem of dry cutting method is closely controlled and solved. In conclusion, the proposed NCC method is superior to the dry cutting method in all aspects, including cutting performance, dust vacuum efficiency and cooling effect. The proposed NCC system is believed to be able to provide eco-friendly cutting technology to various industries, such as the removal of the SOC structures and the dismantling of nuclear plants, which have recently become a hot issue in the field of concrete cutting.

차세대고속열차 본선 시운전 성능평가 방안에 대한 연구 (A Study on Performance Evaluation Plan of Next-Generation High-Speed Prototype Train during Test Run)

  • 김상수;최성훈;박춘수;김석원;김기환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1814-1820
    • /
    • 2010
  • Korean Train Express (KTX) has been commercially operating and achieving elevation on transport capacity since 2004. And the first hish-speed prototype test train, HSR-350x, was developed and succeeded in testing of running over 350km/h. Now KTX-II based on HSR-350x was started in service run. The new high-speed train development project, HEMU-400x project, has started since 2007. The protype train is being designed and manufactured. After the train are developed completely, it will run on the commercial line and will be test to verify the estimated performance. The authors devised the performance evaluation method and process of the HEMU-400x prototype system. And we introduce the definite performance test items and the method to vitrificate them in this paper.

  • PDF