• Title/Summary/Keyword: Test handler

Search Result 21, Processing Time 0.019 seconds

Reduction of Temperature Variation at Measurement Points of Semiconductor Test Handler (반도체 테스트 핸들러 측정점간의 온도 편차 감소)

  • Kim, Jae-Yong;Cho, Su-Young;Kang, Tae-Sam;Lee, Ho-Joon;Koh, Kwang-Ill
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.77-84
    • /
    • 1998
  • The temperature difference occurs at the test points of chamber, because the traditional Test Handler consists of a heater and a fan. To reduce the temperature variation at different points in the chamber, we divided the heater to three parts which are controlled independently. First, we identified the chamber's parameter and then designed a LQG controllers by the identification model. RTD sensors and VME system were used to construct the temperature control system. In our experiment for the proposed control system, the temperature variation was reduced from ${\pm}1.5^{\circ}C$ to ${\pm}0.35^{\circ}C$ at 50$^{\circ}C$ ${\cdot}$ 80$^{\circ}C$ and 120$^{\circ}C$.

  • PDF

A Fuzzy Search Method for Auto Focusing of CCM Test Handlers (CCM 테스트핸들러의 자동초점조절을 위한 피지탐색 방법)

  • Kwon, Hyuk-Joong;Yoon, Hee-Sang;Park, Tae-Hyoung
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.123-126
    • /
    • 2006
  • We propose a new-focusing method for test handlers of compact camera module (CCM), The MMD (max-min difference) method is applied to calculate the focus value quickly considering the noisy output of CCM. Also, the fuzzy search method is applied to find the maximum focus value effectively. We design a fuzzy processor to control the lens position by focus values and brightness values, which improves the focusing performance in the sense of speed and processor memory. The proposed method is implemented by program and installed at the CCM test handler machines. The simulation results are presented to verify the usefulness of the proposed method.

  • PDF

Implementation and compatibility Test of KAX. 25 Link Layer Protocol for Microsatellite Packet Communications (소형위성 패킷 통신용 KAX. 25 링크층 프로토콜의 구현과 적합성 시험)

  • 이영노;성단근;김동규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.19 no.9
    • /
    • pp.1648-1657
    • /
    • 1994
  • This paper is concerned with the development of a packet communication protocol KAX. 25 to be used on the KITSAT microsatellite. As a part of the KAX, 25 protocol, an interrupt driven I/O driver, I/O handler and an AX. 25 radio communication protocol are implemented in the KASCOM that will be used as On-Board Computer in the next missions. The implemented protocol is applied to the enginnering model of the KITSAT-2 satellite in the test configuration simulating the link between the satellite and the ground station and the compatibility of the data link layer protocol is tested.

  • PDF

Convergence Evaluating Food Safety Knowledge, Attitude, and Practice regarding Food handler (식품취급자의 식품안전에 대한 지식, 인식 및 행태의 융합적 평가)

  • Kim, Junghyun;Cho, Youngtae
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.6
    • /
    • pp.73-78
    • /
    • 2019
  • This study aimed to assess the level of food safety knowledge, attitude and practices (KAP) among 500 Food handlers of hospitals in Korea and to explore the association between their knowledge, attitude and practices (KAP) and the socio-demographic characteristics. Self-reported questionnaire contains 50 questions: 15 for knowledge, 15 for attitude, and 20 for practice on food safety. The results showed that the overall mean of the knowledge score is 3.25, attitude 3.65, and practice 3.36 respectively. There was a significant difference between the mean score for knowledge, practice and overall KAP in three aged groups. Also, the overall KAP scores were significantly (p < 0.05) affected by the education level, where the average scores increased with the level of education. Public health preventive education and program should be provided to the food handlers in order to minimize foodborne hazards.

Vibration Reduction of Pipe Line in Air-conditioner for Railway Vehicle (철도차량용 냉방기 배관계의 진동저감 연구)

  • You, Won-Hee;Jung, Yong-Ho;Koo, Jeong-Seo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.925-931
    • /
    • 2012
  • The air-conditioner for railway vehicle should have vibration durability in order to operate normally in vehicle running situation. KS R 9144(vibration test methods for railway vehicle parts) is used to verify the vibration durability. The specifications of compressor, condenser and evaporator for air-conditioner in railway vehicle are standardized, but the shape and structure of pipe lines are not specified. Because the air-conditioner handler produces the pipe line arbitrarily, sometimes the pipe line is broken during the vibration durability test. In this research the cause identification and solution of pipe line breaking problem in during the vibration durability test were studied for air-conditioner of railway vehicle(diesel multiple unit). It was found that the natural frequency of pipe line is related to the pipe line breaking by experiment. A new pipe line shape was introduced by using FEA in order to avoid the resonance. The prototype new pipe line was applied to air-conditioner and the natural frequency was measured by experiment in order to verify the resonance avoidance. The vibration reduction of air-conditioner with new pipe line was reviewed by comparing to the air-conditioner with original one.

Development of an Auto Socket Management Technique for Semicon Production Syste, (반도체 생산 시스템의 자동 Socket 관리 기술 개발)

  • 정화영;김종훈
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10c
    • /
    • pp.167-169
    • /
    • 1999
  • 산업응용 시스템에 있어서의 생산성이란 시스템의 성능 및 효율성에 관한 척도가 된다. 따라서, 시스템의 개발 전과정에서 이를 향상시키려는 많은 노력이 이루어진다. 특히 반도체의 제조공정에서는 이를 위한 노력이 민감하게 발전되어 왔다. 이들 중 IC Test Handler의 Socket관리는 제품(Device)의 생산량과 함께 시스템의 효율성에 직접적인 영향을 주는 부분으로 많은 연구 및 개발이 이루어지고 있다. 본 논문에서는 이러한 생산성 및 효율성을 높이기 위한 자동 Socket 관리 시스템을 개발하여 사용자(Operator)에게 보다 향상된 시스템 환경을 제공하고자 한다. 이를 위해 PC 환경의 GUI 시스템을 도입하였으며, 실제적인 제어부분은 Real Time 운영체제를 탑재한 VME 시스템이 담당하였다. 또한, 신뢰성을 위하여 날짜별 데이터를 하드디스크에 저장하여 Socket 데이터를 사용자가 확인할 수 있도록 하였다.

  • PDF

A study on developing a new self-esteem measurement test adopting DAP and drafting the direction of digitalizing measurement program of DAP (청소년 자존감 DAP 인물화 검사 개발 및 디지털화 측정 시스템 방향성 연구)

  • Woo, Sungju;Park, Chongwook
    • Journal of the HCI Society of Korea
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • This is to develop a new way of testing self-esteem by adopting DAP(Draw a Person) test and to make a platform to digitalize it for young people in the adolescent stage. This approach is to get high effectiveness of the self-esteem measurement using DAP test, including some personal inner situations which can be easily missed in the large statistical analysis. The other objective of this study is digitalize to recover limits of DAP test in the subjective rating standard. It is based on the distribution of the figure drawing expressed numerically by the anxiety index of Handler. For these two examinations, we made experiment through 4 stages with second grade middle school 73 students from July 30th to October 31th in 2009 during 4 months. Firstly, we executed 'Self Values Test' for all 73 people, and divided them into two groups; one is high self-esteem group of 36 people, the other is low self-esteem group of 37 people. Secondly, we regrouped them following D (Depression), Pd (Psychopathic Deviate), Sc (Schizophrenia) scales of MMPI; one is high self-esteem group of 7 people, the other is low self-esteem group of 13 people. Thirdly, we conducted DAP test separately for these 20 people. We intended to verify necessity and appropriateness of direction of 'Digitalizing Measurement System' by comparing and analyzing relation between DAP and Self-esteem following evaluation criteria which has similarity in 3 tests, after executing DAP to reflect peculiarity of adolescents sufficiently. We compared and analyzed result abstracted by sampling DAP test of two groups; One is high self-esteem group of 2 people, the other is low self-esteem group of 2 people; to confirm whether we can improve limitation that original psychological testing has by comparing mutual reliance of measurement test. Finally, with DAP test gained from correlations between self-esteem and melancholia following as above-mentioned steps, we discovered possibility of realization to get a concrete and individual criteria of evaluation based on Expert System as a way of enhancing accessibility in quantitative manner. 'Digitalizing Measurement Program' of DAP test suggested in this study promote results' reliability based on existing tests and measurement.

  • PDF

Comparison of Conditions for Cell Death-Inducing Agents Using a High Throughput-Compatible Nuclear Staining Assay (핵 염색을 이용한 세포사멸 유도물질 스크리닝의 조건 비교)

  • Lee, Sang-Han
    • Journal of Life Science
    • /
    • v.18 no.9
    • /
    • pp.1312-1315
    • /
    • 2008
  • High throughput-drug screening plays a pivotal role for early stage of drug discovery process. In the course of assay development for screening of cell death-inducing agents, a protocol that is simple, time-saving, and high throughput-compatible was designed which was confirmed that the protocol can be worked by a HTS-compatible machine. In 96-well format, PC-3 cancer cells (1${\times}10^{4}$ cells/ml) were cultured for 24 hr. After 24 h-incubation with various medicinal plants extracts, the cells were then stained with DAPI for 30 min. The fluorescence intensity of the stained cells was measured semi-automatically with a multilabel counter. To test whether the present assay system effectively works, we screened about 850 medicinal plant extracts, and selected 1 positive crude extracts that contained cell death-inducing activity. These results suggest that the protocol is highly amenable to HTS implementation for a cell death-inducing agent(s).

Non-Preemptive Fixed Priority Scheduling for Design of Real-Time Embedded Systems (실시간 내장형 시스템의 설계를 위할 비선점형 고정우선순위 스케줄링)

  • Park, Moon-Ju
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.2
    • /
    • pp.89-97
    • /
    • 2009
  • Embedded systems widely used in ubiquitous environments usually employ an event-driven programming model instead of thread-based programming model in order to create a more robust system that uses less memory. However, as the software for embedded systems becomes more complex, it becomes hard to program as a single event handler using the event-driven programming model. This paper discusses the implementation of non-preemptive real-time scheduling theory for the design of embedded systems. To this end, we present an efficient schedulability test method for a given non-preemptive task set using a sufficient condition. This paper also shows that the notion of sub-tasks in embedded systems can overcome the problem of low utilization that is a main drawback of non-preemptive scheduling.

Web-based QA Workflow System for Radioactive Waste Disposal (방사성 폐기물 처분연구의 QA절차에 따른 웹기반 문서처리 워크플로우 시스템 개발)

  • 김태운;고창성;서대희;이광욱;강철형;황용수;이연명
    • The Journal of Information Systems
    • /
    • v.12 no.1
    • /
    • pp.159-175
    • /
    • 2003
  • During the early stage of radioactive disposal programs, important issues related with quality assurance of data sets, methodologies, R&D procedures are recognized as important ones. This paper focused on the development of web-based workflow standards for the QA procedures of the radioactive waste disposal programs. The flow of process was analyzed based on workflow concepts proposed by the Workflow Management Coalition (WfMC). QA system is based on the principles of T2R3. T2R3 Workflow was used to standardize and restructure the business and/or work process in the industry or organization. The WfMC has identified five functional interfaces to a workflow service as part of its standardization program. They are composed of process definition interface, worklist handler, application program interface, interface between workflows, and system management. The task flow and QA program were defined based on the workflow ideas. QA procedures for the R&D results of radiation disoposal were analyzed following the reference model of workflow. In addition, six program run list were created and implemented. The creation, revision, and approval of the test data were designed to be inplemented on the web environment. Through this system, R&D procedures such as planning, research, documentation, internal review and future independent peer review processes could be well organized and stored more systematically on the database and knowledge base. This will encourage the usage and data sharing between interested parties through it's clear and transparent workflow standards.

  • PDF