• 제목/요약/키워드: Test dust

검색결과 401건 처리시간 0.512초

Elution Safety of Recycled Plastic/EAF Dust Composites by Using Leaching Test (폐플라스틱/제강 Dust 성형제의 용출안전성에 대한 연구)

  • Kang, Young-Goo;Song, Jong-Hyeok
    • Journal of the Korean Society of Safety
    • /
    • 제18권4호
    • /
    • pp.85-91
    • /
    • 2003
  • In this study, We have investigated leaching characteristics of heavy metals for recycled plastic composites containing EAF(Electric Arc Furnace) dust & EAF slag. EAF dust & EAF slag used that is generated in the 3 steel-making compaines in domestic. The physical and chemical properties of EAF dust & slag was examined by measuring specific surface area. porosity, oil absorption test and chemical wetting analysis etc. Results of total analysis indicated that EAF dust, slag contained significant amount of hazardous metals such as Cu, Pb, Cd and Cr. But, In the leaching test of the recycled plastic composites containing EAF dust, slag by Korean Standard Leaching Procedure, composites shows much lower leaching concentration of heavy metals. It was concluded that the recycled plastic composites containing EAF dust, slag showed good physical and chemical characteristics. This means that the EAF dust, slag can be effectively used as a functional filler.

The Exposure Level of Respirable Dust of Underground Coal Mines in Taebaek Area (태백지역 석탄광산의 호흡성 분진 폭로 농도)

  • 윤영노;이정주
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제4권1호
    • /
    • pp.23-32
    • /
    • 1988
  • The exposure level of respirable dust and silica for the coal workers of underground coal mines in Taebaek area was evaluated. Personal air samplers were attached to the coal workers-drillers, coal cutters, their helpers, haulers, and separators. Normality and lognormality of respirable dust and silica concentrations were tested by Kolmogorov-Smirnov one-sample test, differences of means of respirable dust and silica concentration were tested by group-t-test and paired t-test, and relation between respirable dust and silica concentration were tested by regression test.

  • PDF

A Study on Dust Control Characteristics inside a Test Dome in the Port of Inchon (인천항 시험돔 내부의 먼지제어특성에 대한 연구)

  • Jeon, ki-Joon;D.Y. Ryu;Jung, Yong-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제16권E호
    • /
    • pp.47-57
    • /
    • 2000
  • This study focuses on the investigation of the effects of windspeed and particle size on the dust control characteristics inside a test dome built in the Port of Inchon to reduce the fugitive dust originating from the handling of animal feed stuff in the open pile area. The flow field inside the test dome and the trajectories of the particles were calculated using a commercial CFD code, FLUENT, assuming that the animal feed stuff handling activity took place inside the test dome. It was found from the simulation results that high windspeed and small particle size give rise to the increase in both the escaped fraction and the suspended fraction of the particles emitted from the animal feed stuff handing activity. Here, high escaped fraction represents the high possibility of fugitive dust problem outside the test dome, whereas high suspended fraction means the high possibility of severe dust pollution inside the test dome. Ore simulation results clearly show that the existing test dome was not designed properly to meet the proposed goal, low escaped fraction and low suspended fraction. Hence, we suggest the need of an efficient ventilation system inside the dome to control the dust.

  • PDF

Development of Cleanroom Garment Design in Semiconductor Industrial Environment (반도체 산업환경에서의 방진복 디자인의 개발)

  • 이윤정;정찬주;정재은
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • 제26권2호
    • /
    • pp.337-348
    • /
    • 2002
  • Based upon literature survey and questionnaire survey, this research tries to develop four new Cleanroom Garment in semiconductor industrial environment. The designs emphasize to minimize workers disconmfort so that they can not only cover human body fully but also reduce dust as much as possible during work hour in clean room. The new designs characteristics and results from both function test and dust emission test are as follows: 1. In order to reduce dust-emission, we develop new designs with hood, kimono sleeve, and back zipper. The designs with hood face positive test results in term of motion suitability and dust-omission. The design with seam in front, in particular, is effective to control dust-emission. 2. For the purpose of reducing dust-emission, we also emphasize to minimize ease of dust-proof wear, with reference to previous research and clothing experiment. The experiment participants report that the new wears are not so comfortable as existing ones, but they accept the new wears positive as effective in reducing dust-emission owing to reduced ease of Cleanroom Garment and sleeves. 3. A1so to reduce dust-emission in inner wear, we put inner wear in both Cleanroom Garments and inner wear, resulting to remove discomfort of wearers when changing clothes and of tight waist due to inner-trousers. 4. We develop new designs with elastic bands in both waist through the side lines and with velcro only at the back side. To remove twist in front contributes to reduce emission arising out of friction, also to free the appearance minding woman workers from worrying about exposed stomach. The new designs need to be accepted as a valuable alternative of Cleanroom Garment, in that they are highly effective to reduce dust-emission, which is the most important factor in the wear, in spite of some drawbacks in terms of motion-suitability, ease and appearance as shown in wearing test.

A Study on the Performance Test of Axial-flow Cyclone Separator (축상유입식 사이클론 집진기 성능시험에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • 제23권1호
    • /
    • pp.101-106
    • /
    • 2020
  • Along with dust collection efficiency, pressure loss is a very important cyclone operation factor. A severe rise in pressure loss causes the problem of cost. To solve the problem, the method connecting axial-vane type cyclones in parallel is suggested recently. The axial vane type cyclone dust collector applied in this study is a small portable type. Multiple cyclones are installed in a round type. The basic performance test on the axial vane type cyclone dust collector was conducted. As a result, the cut size reduced along with a rise in the wind velocity of the cyclone dust collector inlet. According to the test on dust collection efficiency, the effect of dust collection began to appear in the range of 3㎛ and dust collection efficiency was greatly improved at 5 ㎛. The noise of the cyclone dust collector well met the fan sound power level of KSB 6361.

Material Properties of Concrete Specimens with Electric Arc Furnace Dust as Admixture (전기로제강분진(EAF Dust)을 혼화재로 배합한 콘크리트 공시체의 재료특성)

  • 김장호;김석호;김성훈;김동완
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.669-674
    • /
    • 2001
  • Electric Arc Furnace Dust (EAF Dust) Is residual dust produced during the manufacturing of metal products from heavily heated electric arc furnace. Many researches have focused on recycling and reusing EAF Dust for industrial and construction purposes. However, most of these researches were aimed at obtaining useful heavy metal powders by treating toxic metallic materials in EAF Dust. Also, few researches dealt with using EAF Dust as admixture in concrete mixture (i.e., slag dust). In this study, EAF Dust is used as admixture in concrete mixture content considering economical feasibility and construction applicability. The concrete specimens mixed with EAF Dust is then tested in compression and tension to study its strength and ductility as well as its failure mechanism. The compression and tension (by split cylinder test) test results are compared to the results from the specimens without EAF Dust to understand the chemical stability and mechanical characteristic of concrete specimens with EAF Dust. For the experiment, 6 types of admixture added concrete were studied: ⑴Combination of EAF Dust and blast-furnace slag in 1 to 1 ratio, ⑵Combination of EAF Dust and blast-furnace slag in 1 to 2 ratio, ⑶EAF Dust only, ⑷blast-furnace slag only, ⑸fly ash only, and ⑹no admixture. The experimental results show that the strength of EAF Dust added specimen has lower early age strength but higher 28 day strength when compared to other specimens. Also, the Elastic Modulus of EAF Dust is higher(28 days) than other specimens. The study results prove that EAF Dust can be used as an effective admixture in concrete for specific usages.

  • PDF

The climate change by Strengthening of die dust test (한반도 기후 변화로 인한 먼지시험의 강화)

  • Yoo, Sung-Kyu;Kim, Chul-Hee;Cho, Jai-Rip
    • Proceedings of the Korean Society for Quality Management Conference
    • /
    • 한국품질경영학회 2009년도 추계학술대회
    • /
    • pp.252-255
    • /
    • 2009
  • Since the 2000s on the Korean Peninsula has been gradually increasing of frequency of Dust-Storm. These environmental changes due to the dust test are increasing in proportion of normal environment test. However, increasingly is becoming less important than the results of the study, through this research, I will pursue the trends of Dust Test and the direction of the prospect change.

  • PDF

Prediction of changes in fine dust concentration using LSTM model

  • Lee, Gi-Seok;Lee, Sang-Hyun
    • International journal of advanced smart convergence
    • /
    • 제11권2호
    • /
    • pp.30-37
    • /
    • 2022
  • Because fine dust (PM10) has a close effect on the environment, fine dust generated in the climate and living environment has a bad effect on the human body. In this study, the LSTM model was applied to predict and analyze the effect of fine dust on Gwangju Metropolitan City in Korea. This paper uses prediction values of input variables selected through correlation analysis to confirm fine dust prediction performance. In this paper, data from the Gwangju Metropolitan City area were collected to measure fine dust. The collection period is one year's worth of data was used from january to December of 2021, and the test data was conducted using three-month data from January to March of 2022. As a result of this study, in the as a result of predicting fine dust (PH10) and ultrafine dust (PH2.5) using the LSTM model, the RMSE was 4.61 and the test result value was as low as 4.37. This reason is judged to be the result of the contents of the one-year sample.

An experimental study on the development and verification of NCC(new concrete cutting) system

  • Park, Jong-Hyup;Han, Jong-Wook
    • Structural Engineering and Mechanics
    • /
    • 제65권2호
    • /
    • pp.203-211
    • /
    • 2018
  • This paper introduces the development process of NCC(New Concrete Cutting) system and analyzes first verification test. Based on the first verification test results, some problems of NCC system have been newly modified. We carry out the second verification test. We tried to verify cutting performance and dust control efficiency of NCC system through the cutting test of concrete bridge piers. In particular, this verification test strives to solve the problem of concrete dust, which is the biggest problem of dry cutting method. The remaining dust problems in cutting section tried to solve through this verification test. This verification test of the NCC system shows that the dust problem of dry cutting method is closely controlled and solved. In conclusion, the proposed NCC method is superior to the dry cutting method in all aspects, including cutting performance, dust vacuum efficiency and cooling effect. The proposed NCC system is believed to be able to provide eco-friendly cutting technology to various industries, such as the removal of the SOC structures and the dismantling of nuclear plants, which have recently become a hot issue in the field of concrete cutting.

Genernal Pharmacological and Acute/Subacute Toxicity Test of House Dust Mite Extract in Mice, Rats, and Guinea pigs (마우스, 랫트, 해명에서 집먼지 진드기 추출물의 일반 약리시험과 급성 및 아급성 독성에 관한 연구)

  • 노재열;김경환
    • Toxicological Research
    • /
    • 제14권2호
    • /
    • pp.183-191
    • /
    • 1998
  • It has been reported that 50~70% of child asthma, bronchial asthma in adult, and allergic rhinitis are caused by house dust mite. The antigen extracted from house dust mite has been used for effective treatment against allergic diseases and for clinical test. This house dust mite antigen has been entirely imported from abroad. However, the composition and content of all the antigen imported vary from a brand to other brand. Thus, we need to standardize the composition and content of the antigen by developing it domestically. We proceeded pre-clinically general pharmacological test and toxicological test that are required for the eventual human use by utilizing the house dust mite cultured in Korea. In order to obtain information on general pharmacological tests such as its toxic signs in tissues or organs which are mainly affected, we examined the effect of house dust mite on the tensions of the isolated tissues and heart rates of cardiac muscle by recording with force displacement transducer of polygragh (Glass Model 7). We determined lethality of antigen extracted from house dust mite in mice and guinea pigs. We examined acute and subacute toxicity by administrating house dust mite extract of 500, 100, 20 times of the expected clinical dose. In male and female mice and guinea pigs, given a sigle intraperitoneal dose of antigen, $LD_{50}$ values were over 5.0 $\textrm{m}{\ell}$/kg, respectively. In animals administrated with house dust mite, there were no significant change of clinical symptom, body weight, food consumption, water consumption, eye examinations, urinalysis, blood biochemistry, and histopathological examinations in any animals tested. We found no toxic effect of this house dust mite. These results show that the house dust mite cultured by us could be used in the development of medicine against allergic diseases caused by the antigen of house dust mite.

  • PDF