A Study on Dust Control Characteristics inside a Test Dome in the Port of Inchon

인천항 시험돔 내부의 먼지제어특성에 대한 연구

  • Jeon, ki-Joon (Division of Environmental Geosystem Engineering, Inha University) ;
  • D.Y. Ryu (Division of Environmental Geosystem Engineering, Inha University) ;
  • Jung, Yong-Won (Division of Environmental Geosystem Engineering, Inha University)
  • Published : 2000.05.01

Abstract

This study focuses on the investigation of the effects of windspeed and particle size on the dust control characteristics inside a test dome built in the Port of Inchon to reduce the fugitive dust originating from the handling of animal feed stuff in the open pile area. The flow field inside the test dome and the trajectories of the particles were calculated using a commercial CFD code, FLUENT, assuming that the animal feed stuff handling activity took place inside the test dome. It was found from the simulation results that high windspeed and small particle size give rise to the increase in both the escaped fraction and the suspended fraction of the particles emitted from the animal feed stuff handing activity. Here, high escaped fraction represents the high possibility of fugitive dust problem outside the test dome, whereas high suspended fraction means the high possibility of severe dust pollution inside the test dome. Ore simulation results clearly show that the existing test dome was not designed properly to meet the proposed goal, low escaped fraction and low suspended fraction. Hence, we suggest the need of an efficient ventilation system inside the dome to control the dust.

Keywords