• Title/Summary/Keyword: Test Validation

Search Result 1,781, Processing Time 0.03 seconds

Use of CFD For Design Validation of A Transonic Civil Transport

  • Ok, Honam;Kim, Insun;Choi, Seong-Wook;Sung, Bongzoo
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.1 no.1
    • /
    • pp.13-20
    • /
    • 2000
  • The applications of CFD in the design process of a transonic civil transport at Korea Aerospace Research Institute (KARI) are outlined. Three Navier-Stokes solvers, developed at KARI with different grid approaches, are used to predict the aerodynamic coefficients and solve the flowfield of various configurations. Multi-block, Chimera, and unstructured grids are the approaches implemented. The accuracy of the codes is verified for the transonic flow about RAE wing/fuselage configuration. The multi-block code is used to provide the detailed data on the flowfield around a wall interference model with different test section sizes which will be used in establishing the wall interference correction method. The subsonic and transonic flowfields about K100-04A, one of the configurations of a 100-seater transport developed by KARI and Korea Commercial Aircraft Development Consortium (KCDC), are computed to predict the aerodynamic coefficients. The results for the subsonic flow are compared with those of wind tunnel test, and the agreement is found to be excellent. The interference effect of nacelle installation on the wing of K100-04A is also investigated using the unstructured grid method, and about 10% reduction in wing lift is observed. The accuracy of the three developed codes is verified, and they are used as an efficient tool in the design process of a transonic transport.

  • PDF

Experimental Framework for Controller Design of a Rotorcraft Unmanned Aerial Vehicle Using Multi-Camera System

  • Oh, Hyon-Dong;Won, Dae-Yeon;Huh, Sung-Sik;Shim, David Hyun-Chul;Tahk, Min-Jea
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.11 no.2
    • /
    • pp.69-79
    • /
    • 2010
  • This paper describes the experimental framework for the control system design and validation of a rotorcraft unmanned aerial vehicle (UAV). Our approach follows the general procedure of nonlinear modeling, linear controller design, nonlinear simulation and flight test but uses an indoor-installed multi-camera system, which can provide full 6-degree of freedom (DOF) navigation information with high accuracy, to overcome the limitation of an outdoor flight experiment. In addition, a 3-DOF flying mill is used for the performance validation of the attitude control, which considers the characteristics of the multi-rotor type rotorcraft UAV. Our framework is applied to the design and mathematical modeling of the control system for a quad-rotor UAV, which was selected as the test-bed vehicle, and the controller design using the classical proportional-integral-derivative control method is explained. The experimental results showed that the proposed approach can be viewed as a successful tool in developing the controller of new rotorcraft UAVs with reduced cost and time.

Development and Validation of Crocidolite Quality Control Samples for Proficiency Analytical Testing (청석면 분석 정도관리용 표준시료 개발 및 평가)

  • Lee, Ji-Hyun;Kim, Eun-Young;Noh, Su-Jin;Park, Yong-Jin;Jeong, Jee-Yeon
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.1
    • /
    • pp.57-63
    • /
    • 2011
  • Crocidolite quality control (QC) sampling created by the wet generation method has been validated by validation tests such as the accuracy, precision, and storage tests. For this study we designed and developed a manufacturing apparatus and standard operating procedure for making these QC samples. The most important step in the procedure of making QC samples was the stage eliminating static electricity in asbestos fibers. This static electricity hampers the fibers clog functioning. In accuracy and precision tests by phase contrast microscopy analysis, the difference between the reference values and the studied values was at maximum 17.8%. This satisfies the AIHA proficiency analytical test criteria for asbestos. We could confirm the nearly even distribution of crocidolite fibers on the membrane filter. Also, there was no loss of fibers in the storage test after the one month.

Validation of a Local Failure Criteria Using the Results of Wall-Thinned Pipe Failure Tests (감육배관 손상시험 결과를 이용한 국부손상기준 검증)

  • Kim, Jin-Weon;Lee, Sung-Ho;Park, Chi-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.12
    • /
    • pp.1393-1400
    • /
    • 2009
  • The objective of this study is to validate local failure criteria, which were proposed based on the notched-bar specimen tests combining with finite element (FE) simulations, using the results of real-scale pipe failure tests. This study conducted burst test using wall-thinned pipe specimens, which were made of 4 inch Sch.80 ASTM A106 Gr.B carbon steel pipe, under simple internal pressure at ambient temperature and performed associated FE simulations. Failure pressures were estimated by applying the failure criteria to the results of FE simulations and were compared with experimental failure pressures. It showed that the local stress based criterion, given as true ultimate tensile stress of material, accurately estimated the failure pressure of wall-thinned pipe specimens. However, the local strain based criterion, which is fracture strain of material as a function of stress tri-axiality, could not predict the failure pressure. It was confirmed that the local stress based criterion is reliably applicable to estimation of failure pressure of local wall-thinned piping components.

Simultaneous Determination of Four Bioactive Constituents in Galgeun Tang by HPLC/DAD. (HPLC-DAD를 이용한 갈근탕 중 4종 성분의 동시분석법 확립)

  • Won, Jin-Bae;Jeon, Won-Kyung;Ma, Jin-Yeul;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.40 no.3
    • /
    • pp.224-228
    • /
    • 2009
  • For the quality control of traditional herbal medicine, Galgeun tang, simultaneous determination of glycyrrhizin, paeoniflorin, puerarin, 6-gingerol was established by using a high performance liquid chromatographic (HPLC) method with diode array detector. To separate five four constituents, DIONEX $C_{18}$ column ($5{\mu}m$, $120{\AA}$, $4.6\;mm{\times}150\;mm$) was used with gradient elution system of water and methanol. Validation of the chromatography method was evaluated by linearity, recovery, and precision test. Calibration curve of standard components showed excellent linearity ($R^2$>0.9906). Limits of detection (LOD) and limits of quantification (LOQ) varied from 0.15 to $0.52{\mu}g$/ml and 0.27 to $0.80{\mu}mg$/ml, respectively. The relative standard deviations (RSDs) of data of the intra-day and inter-day experiments were less than 2.88% and 1.21%, respectively. The results of recovery test were ranged from 96.71 to 106.29% with RSD values 0.01-0.80%.

Noninvasive molecular biomarkers for the detection of colorectal cancer

  • Kim, Hye-Jung;Yu, Myeong-Hee;Kim, Ho-Guen;Byun, Jong-Hoe;Lee, Cheolju
    • BMB Reports
    • /
    • v.41 no.10
    • /
    • pp.685-692
    • /
    • 2008
  • Colorectal cancer (CRC) is the third most common malignancy in the world. Because CRC develops slowly from removable precancerous lesions, detection of the disease at an early stage during regular health examinations can reduce both the incidence and mortality of the disease. Although sigmoidoscopy offers significant improvements in the detection rate of CRC, its diagnostic value is limited by its high costs and inconvenience. Therefore, there is a compelling need for the identification of noninvasive biomarkers that can enable earlier detection of CRC. Accordingly, many validation studies have been conducted to evaluate genetic, epigenetic or protein markers that can be detected in the stool or in serum. Currently, the fecal-occult blood test is the most widely used method of screening for CRC. However, advances in genomics and proteomics combined with developments in other relevant fields will lead to the discovery of novel non invasive biomarkers whose usefulness will be tested in larger validation studies. Here, non-invasive molecular biomarkers that are currently used in clinical settings and have the potential for use as CRC biomarkers are discussed.

Noise Removal using Support Vector Regression in Noisy Document Images

  • Kim, Hee-Hoon;Kang, Seung-Hyo;Park, Jai-Hyun;Ha, Hyun-Ho;Lim, Dong-Hoon
    • The Korean Journal of Applied Statistics
    • /
    • v.25 no.4
    • /
    • pp.669-680
    • /
    • 2012
  • Noise removal of document images is a necessary step during preprocessing to recognize characters effectively because it has influences greatly on processing speed and performance for character recognition. We have considered using the spatial filters such as traditional mean filters and Gaussian filters, and wavelet transformed based methods for noise deduction in natural images. However, these methods are not effective for the noise removal of document images. In this paper, we present noise removal of document images using support vector regression. The proposed approach consists of two steps which are SVR training step and SVR test step. We construct an optimal prediction model using grid search with cross-validation in SVR training step, and then apply it to noisy images to remove noises in test step. We evaluate our SVR based method both quantitatively and qualitatively for noise removal in Korean, English and Chinese character documents, and compare it to some existing methods. Experimental results indicate that the proposed method is more effective and can get satisfactory removal results.

Modified Kolmogorov-Smirnov Statistic for Credit Evaluation (신용평가를 위한 Kolmogorov-Smirnov 수정통계량)

  • Hong, C.S.;Bang, G.
    • The Korean Journal of Applied Statistics
    • /
    • v.21 no.6
    • /
    • pp.1065-1075
    • /
    • 2008
  • For the model validation of credit rating models, Kolmogorov-Smirnov(K-S) statistic has been widely used as a testing method of discriminatory power from the probabilities of default for default and non-default. For the credit rating works, K-S statistics are to test two identical distribution functions which are partitioned from a distribution. In this paper under the assumption that the distribution is known, modified K-S statistic which is formulated by using known distributions is proposed and compared K-S statistic.

A Design of Automated Contingency Management and Case Study for Monopropellant Propulsion System (단일추진시스템의 ACM 설계 및 사례연구)

  • Lee, Young-Jin;Lee, Kwon-Soon;Vachtsevanos, George
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.16 no.2
    • /
    • pp.1-11
    • /
    • 2008
  • Increasing demand for improved reliability and survivability of mission-critical systems is driving the development of health monitoring and Automated Contingency Management (ACM) systems. An ACM system is expected to adapt autonomously to fault conditions with the goal of still achieving mission objectives by allowing some degradation in system performance within permissible limits. ACM performance depends on supporting technologies like sensors and anomaly detection, diagnostic/prognostic and reasoning algorithms. This paper presents the development of a generic prototype test bench software framework for developing and validating ACM systems for advanced propulsion systems called the Propulsion ACM (PACM) Test Bench. The architecture has been implemented for a Monopropellant Propulsion System (MPS) to demonstrate the validity of the approach. A Simulink model of the MPS has been developed along with a fault injection module. It has been shown that the ACM system is capable of mitigating the failures by searching for an optimal strategy. Furthermore, the concepts of Validation and Verification (V&V) of such systems are introduced with relevant examples.

  • PDF

Development of an Ejector System for Operating of Chemical Lasers (III) - Development and Performance Validation of a Full-Scale Ejector System for High Power Chemical Lasers - (화학레이저 구동용 이젝터 시스템 개발 (III) - 고출력 화학레이저용 실물 크기의 이젝터 시스템 개발 및 성능 검증 -)

  • Kim, Se-Hoon;Jin, Jung-kun;Kwon, Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.9-15
    • /
    • 2005
  • From the geometric parameter study, an optimal ejector design procedure of pressure recovery system for chemical lasers was acquired. For given primary flow reservoir conditions, an up-scaled ejector was designed and manufactured. In the performance test, secondary mass flow rate of 100g/s air was entrained satisfying the design secondary pressure, $40{\sim}50torr$. Performance validation of a supersonic ejector system along with an investigation of effects of supersonic diffuser was conducted. Placement of the diffuser at the secondary inlet further reduced diffuser upstream pressure to 7torr. Lastly, the duplicate of apparatus (air 500g/s secondary mass flow rate each) was built and connected in parallel to assess proportionality behavior on a system to handle larger mass flow rate. Test and comparison of the parallel unit demonstrated the secondary mass flow rate was proportional to the number of individual units that were brought together maintaining the lasing pressure.