• Title/Summary/Keyword: Test Standards

Search Result 2,241, Processing Time 0.028 seconds

The Development of the 7th National Curriculum-based Achievement and Assessment Standards for 1st and 2nd Grades in the Primary School Level (수학과 성취기준과 평가기준 개발 연구 - 초등학교 1, 2학년을 중심으로 -)

  • 황혜정
    • School Mathematics
    • /
    • v.2 no.1
    • /
    • pp.73-95
    • /
    • 2000
  • In this study, on the basis of the seventh national mathematics curriculum, the achievement standards were developed to specify the objectives and contents of teaching-learning at the first and second elementary school mathematics. The assessment standards were also developed to differentiate students’ levels of achievement with ‘high’, ‘mid’ and ‘low’ categories. Furthermore, this stuffy suggested the exemplary test items including short-answer and open-ended questions while putting emphasis on students' real performance to increase their ability in solving problems rather than in calculating. In addition to the test items, it introduced the grading system developed to grade the items with concrete guidelines and to report students' achievement on doing mathematics.

  • PDF

A Study on the KS Standardization of Test Rooms for the Measurement of Sound Insulation in Buildings and. of Building Elements (건물 및 건물부재의 차음성능 측정을 위한 표준 측정실의 KS 규격화에 관한 연구)

  • Oh, Yang-Ki;Kim, Heung-Sik;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.336-339
    • /
    • 2000
  • Revision of KS, Korean Standards, is currently actively discussed. It is just the time for a new world class standards under the new system with WTO, World Trade Organization. This paper is a part of "Researchs on the Standards in the Building Acoustic Field", as one of KS revision projects. The aim of this study is to define the requirements of laboratory test facilities with suppressed flanking transmission. In the former KS, there is no items matched with this purpose. Therefore comparing several results with different measuring conditions of a laboratory and results between different laboratories was impossible. On these basis, a new part of KS is proposed, and some problems remained and further discussions in the proposed draft are described in this study.

  • PDF

An Experimental Study on the Verification of Fire Extinguishing Performance According to the Combustion Characteristics of Building Window Frame (건축물 창호 프레임의 연소특성에 따른 방화성능 검증에 관한 실험적 연구)

  • Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.54-55
    • /
    • 2021
  • This study compared the fire safety standards for windows of Korea, the U.S. and Japan to prevent fire expansion through exterior wall openings, and conducted experiments using PVC and aluminum window frames, which are widely used in Korea.The experiment is KS F 2845 which combines frames of the same thickness and area with single-window form and 1 hour fire resistance glass with 8T thickness. Experiments showed that the PVC window was about 9 minutes and the aluminum window was about 26 minutes. However, in Korea, there are no test standards for windows installed at the opening of the exterior wall. In addition, fire safety standards for windows shall be established along with the designation of fire prevention zones.

  • PDF

Test method for Motor/controller for Electric Vehicle (전기자동차용 전동기/제어기의 시험 방법)

  • 오성철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.328-335
    • /
    • 2003
  • Test procedure for Electric Vehicle(EV) motor/controller has been developed. Most of existing standards mainly focus on minimum requirements for safe operation. However, detailed test procedures are not covered in the standard. In order to develop test items, methods and procedures which should be strictly applied to EV motor and controller, existing standards have been reviewed by the expert group in Korea. Based on their feedback, standard test procedure was proposed. Test procedure especially for combined motor and controller has been proposed. As a load lot the tested motor, M-G set, eddy current type engine dynamo and AC dynamo were used. Test procedures for the driving cycle test and regeneration test were proposed.

Inward Leakage Test for Particulate Filtering Respirators in Korea (방진마스크의 안면부 누설률에 관한 연구)

  • Han Don-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.432-439
    • /
    • 2004
  • Korean certification regulation for particulate filtering respirators requires inward leakage (IL) test as European Standards (EN) and the standard levels of regulation are the same as those of EN. This study was conducted to evaluate particulate filtering respirators being commercially used in the market by using IL and assess the characteristics of IL. The study began with discussing the concept of IL, comparison of IL with fit test, and IL measurement method. Three brands of half masks and 10 brands of filtering facepieces (two top class, four 1st class and four 2nd class), total 13 brands respirators, and 10 test panels (subjects) who were classified in 9 facial grids in accordance with face length and lip length, were selected for IL test. IL tests were conducted in the laboratory of 3M Innovation Center which was established by EN standard. As expected ILs of half masks were lower than those of filtering facepiece mask. ILs of half masks and some filtering facepieces were significantly different in manufacturers. ILs of 1st class filtering facepieces were found to be much more than those of 2nd class and thus the result would cause wearers to get confused to select a mask. Four of six brands being no compliance with standards were thought that they should be tested again for certification because of a lot of differences from standards. There were no significant differences among ILs of five exercises. In 6 out of 13 brands lognormal distribution of ILs may be a better fit distribution and in 7 brands both lognormal and normal distributions were rejected. The result indicates that geometric mean may be better than arithmetic mean to establish standard.

Presentation of Performance Test Criteria for Denuclearization Verification Equipment Considering North Korea Environment (북한 환경을 고려한 비핵화 검증 장비의 성능 시험 기준 제시)

  • Ji-Young, Han;Su-Hui, Park;Yong-Min, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.71-77
    • /
    • 2023
  • The issue of North Korea's denuclearization is an global issue that transcends the North and South. It is necessary to prepare for the denuclearization process in preparation for the situation in which North Korea reveals its intention to denuclearize. In the process of North Korea's denuclearization, it is required to guarantee the normal operation of the denuclearization verification equipment. If a performance test criteria that takes into account the North Korean environment is established, it is highly likely that it will be used in the future denuclearization process. For this purpose, basic materials related to performance test standards were established through analysis of test standards such as international standards. After that, we established a performance test criteria. This includes high temperature, low temperature, humidity, vibration and shock tests. Through follow-up studies, validity of test criteria will be established through actual device testing.

International Standards trend on Hydrogen fuel quality (ISO/TC197/WG12의 수소품질 국제표준화 동향)

  • Cho, Sung-Kook;Cho, Chang-Ae;Lee, Taeck-Hong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.739-743
    • /
    • 2009
  • Japan is leading standards for the hydrogen fuel quality on the PEMFC(Proton Exchange Membrane Fuel Cell) vehicle at ISO/TC197/WG12. However, it has many problems to solve the standard of measurement and the test method. because the standard of measurement which was proposed in Japan is too high to reach the technique for many countries. it might not control standards for the hydrogen fuel quality on the PEMFC vehicle in Korea. So we need to develop the study of standards and the technique of measurement continuously for the International Standards Meeting.

  • PDF

A Study on the Inspection Standards and Methods of Two-Wheeled Motorcycle Headlight (이륜차 전조등 검사기준 및 검사방법에 관한 연구)

  • Ha, Tae-Woong;Hong, Seung-Jun
    • Journal of Auto-vehicle Safety Association
    • /
    • v.12 no.3
    • /
    • pp.7-12
    • /
    • 2020
  • This paper has presented the headlight inspection standards and methods of two-wheeled motorcycles considering Korean Motor Vehicle Safety Standards (KMVSS), Korean Motor Vehicle Inspection Standards (KMVI) and the inspection standards of the International Motor Vehicle Inspection Committee (CITA). As a result of analyzing the headlight luminous intensity test result with fixed inspection equipment, 21% does not meet the inspection standard proposed in this study, and 33.3% in mobile inspection equipment does not meet. The average luminous intensity of motorcycle less than 50 cc is 8,340 cd, so all the lightweight small sized motor cycles do not meet the proposed headlight inspection standard.

Advanced Lubricants for Heat Engines

  • Hsu, S.M.;Li, H.;Perez, J.M.;Ku, C.S.;Wang, J.
    • Tribology and Lubricants
    • /
    • v.11 no.5
    • /
    • pp.47-54
    • /
    • 1995
  • An advanced liquid lubricants for heat engines has been developed and tested successfully in a prototype engine. The lubricant possesses superior oxidation stability and high temperature stability and is capable of surviving for a minimum of three minutes at 425$^{\circ}$C (800$^{\circ}$C) at the ring zone and maintains stability at an oil sump temperature of 171$^{\circ}$C. The lubricant has been evaluated by the Cummins Engine Co. Out of a field of several dozens of lubricant, six lubricant was selected for a prototype 200 hours endurance testing. The NIST lubricant was one of the two lubricants that successfully finished the endurance testing. This paper describes the key lubricant considerations including oxidation and thermal stability, volatility, deposit control. The engine test conditions and the results will be presented.

A Study on the Improvement of Domestic Smoke Control Standards through Analysis the Standards about Air Leakage Rate of Domestic and Abroad (국내·외 누설률에 관한 기준 분석을 통한 국내 연기제어 기준 개선에 관한 연구)

  • Kim, Hye-Won;Han, Ji-Woo;Lee, Byeong-Heun;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.11a
    • /
    • pp.61-62
    • /
    • 2018
  • On this Study, it conducts the Standards investigation about air leakage of Buildings for performance improvement of Smoke control in Fire. In domestic standards, it is incomplete the Criteria standards of air leakage. Therefore it is considered that won't limit the smoke spread due to stack effect. But in the case of the United States, it conducts the Hot smoke air-Leakage test and it consider that can prevent the Smoke Spread in Compartment.

  • PDF