• Title/Summary/Keyword: Test Site

Search Result 3,376, Processing Time 0.029 seconds

A Study on the Land Improvement Effect of Sewage Sludge and Sewage Sludge Dry Fuel Mixture (하수슬러지와 하수슬러지 건조연료 혼합물의 토지개량효과에 관한 연구)

  • Kwon, Gi Woon;Park, Hye Ok;Lee, Kyeong Ho;Kim, Moon Jeong;Lee, Woo Weon;Ryu, Don Sik
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.3
    • /
    • pp.45-49
    • /
    • 2020
  • The aims of this study is to land improvement effect of sewage sludge dry fuel mixture. The mixing ratio of sewage sludge and dry fuel was mixed at a weight ratio of 1:1 to make a mixture, experimental designone was designed as one control (0 %) site and three test groups that each mixture of 10 %, 20 %, 30 % was added. Comparison of yield after cultivation of Kenaf 90days, in the 10 % test group the length of the stem increased by 73 % compared to control site and 20 % test group the leaf yield increased by 227 % compared to control site. It is judged that the growth rating the blooming of 30 % test group is faster than and the chlorophyll content is the highest(71.6SPAD) that of another control. In conclusion, the addition of dry fuel mixtures is effective in improving overall soil quality for plants to live.

A Study on Development of Test Site for Wind Turbine Prototype Test (풍력터빈시험을 위한 실증시험장 개발에 관한 연구)

  • Moon, Chae-Joo;Chang, Young-Hag;So, Soon-Yeol;Kim, Tae-Gon;Kim, Young-Gon;Jeong, Moon-Seon;Jeong, Seong-Won
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.2
    • /
    • pp.101-107
    • /
    • 2013
  • It is evident that in the wind energy business as an economic activity there is a close relationship between the wind speed and the revenues. The wind turbine test facility for wind turbine accreditation is intended to be used by the industry for testing of both main components and systems. This paper suggest the wind test site for certification of prototype wind turbine with international regulations. The test site has an environmental permit for wind turbines with a maximum hub height of 120m and a rotor diameter up to 120m, and can accommodate prototypes with installed electrical powers up to 5MW each. A wind turbine manufacturer can lease the location for a period of type certification. And also researchers are the development of new methods for measuring the influence, performance and durability of the components, a mathematical and numerical modelling of component responses by using the site.

Preliminary Investigation for Feasibility of Wave Energy Converters and the Surrounding Sea as Test-site for Marine Equipment

  • Park, Jin-Yeong;Baek, Hyuk;Shim, Hyungwon;Choi, Jong-Su
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.5
    • /
    • pp.351-360
    • /
    • 2020
  • Of late, demand for test sites for marine equipment such as ASV, AUV, ROV, and various underwater sensors is increasing. The authors have focused on an oscillating water column (OWC), which is being constructed near Chagwido Island Jeju, as one of the test-sites. The main objective of the OWC is to produce wave energy and develop technologies. It has been built in the sea approximately 1 km off the coast. It has berth accommodation and some rooms that can be used as laboratories. To investigate the feasibility of its usage as a test site for marine equipment, we acquired bathymetric data around the OWC by using a multi-beam echo sounder and a single-beam scanning sonar. The accessibility of the OWC from nearby ports and the use of support vessels or ships were also investigated. 3D point cloud data from the multi-beam echo sounder and 2D acoustic images from the scanning sonar are expected to be used as references for identifying changes over time. In addition, through these experiments, we derived a procedure to use this facility as a test site by using the IDEF0 functional modelling method. Based on this preliminary investigation and previously reported examples, we determined the general conditions and preferences for evaluating the performance of various marine equipment heuristically. Finally, we developed five applications that were derived from this investigation.

Single-Dose Toxicity Study of Intramuscular Neuralgia-Pharmacopuncture Injection in Rats

  • Ji Hye Hwang
    • Journal of Pharmacopuncture
    • /
    • v.26 no.4
    • /
    • pp.348-356
    • /
    • 2023
  • Objectives: Neuralgia-pharmacopuncture (NP) was recently developed as a water-soluble type of pharmacopuncture inspired by CS (care special pain)-pharmacopuncture. I aimed to evaluate the toxic response and approximate lethal dose of when NP when administered intramuscularly to Sprague Dawley rats. Methods: The experimental group was divided into the NP test substance group and the saline control group and administered at a dose of 1.0 mL/animal to the posterior thigh muscles on both sides using a 1 mL syringe; each group consisted of five males and five females. Each rat was monitored for clinical signs and changes in body weight for 14 days after a single intramuscular injection. After completing observation, necropsy findings and localized tolerance at the injection site were assessed via gross necropsy and histopathological examination. Results: No deaths occurred in the NP or control group, regardless of sex. During the observation period, no changes (such as general symptoms, weight change, or visual observation results at the time of autopsy) were judged to be due to the test substance. Histopathological examination showed no changes at the administration site judged to be caused by the test substance in either the male or female test substance administration groups. In addition, mononuclear cell infiltration of the outer membrane of the femoris muscle at the administration site was observed at the same frequency and extent in the control and NP groups, and was judged to be caused by physical stimulation by the injection needle; therefore, it had no toxicological significance. Conclusion: Based on the above results, the approximate lethal dose for a single intramuscular administration of the test substance NP in Sprague-Dawley rats was judged to be > 1.0 mL/animal, and there were no findings that were judged to be due to the test substance at the administration site.

ANTIMICROBIAL SUSCEPTIBILITY TEST ON ORAL FLORA FROM DIFFERENT SAMPLING SITES IN CHILDREN (소아에서 구강내 정상세균총에 대한 채취부위별 항균제 감수성 차이에 관한 연구)

  • Shin, Sang-Hun;Kim, Boo-Kyoung;Song, Jung-Ho;Park, Sung-Hwan;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.1
    • /
    • pp.40-44
    • /
    • 2000
  • The most proper antibiotic must be selected after antimicrobial susceptibility test. If difference in antimicrobial susceptibility was significant between oral sampling sites, it is rationale to use the most susceptible antibiotic agent respond to dental procedure and object of treatment. This study examined sampling site variation from saliva, supragingival plaque and subgingival plaque of 16 children's oral microbes. The cultured bacterial isolates, which were Streptococcus viridans and Neisseria, were examined for 10 antimicribial drugs with the Bauer-Kirby agar disk diffusion method. The used drugs were Penicillin, Ampicillin, Oxacillin, Cephalothin, Imipenem, Gentamicin, Erythromycin, Vancomycin, Ciprofloxacin, Clindamycin. There was no significant difference between three sampling sites for antimicrobial susceptibility test of S. viridans and Neisseria and the sequence of susceptibility was agreed among them. In conclusion, it was suggested that antimicrobial susceptibility test from saliva, supragingival plaque and subgingival plaque of children have no significant sampling site variation.

  • PDF

Comparative Study on the Quantity Economic Analysis of Apartment Frames Using SDS Result of Dynamic Centrifuge Test at Pile Foundation (말뚝기초의 동적실험결과를 사용한 아파트 골조의 경제성 비교분석)

  • Kim, Sang-Yeon;Park, Jong-Bae;Park, Yong-Boo
    • Land and Housing Review
    • /
    • v.6 no.3
    • /
    • pp.147-152
    • /
    • 2015
  • Site coefficient and amplification factor of current domestic Seismic Design Code based on American Seismic Code, have no consideration for the domestic ground condition in which the base rock is normally placed within 30m form the surface. By previous studies, the measured spectral acceleration of the result of dynamic centrifugal test and analysis was smaller than the design spectral acceleration for the period over 1.5 sec. Accordingly, in this study structural analysis and design using dynamic centrifugal test result for pile foundation were achieved, and the quantity of concrete and reinforcement of wall frame was compared with each other. Comparison results of cost using KBC the design spectral acceleration of SC, SD site and SDS, the quantity of reinforcement using SDS for SD site was 17~23% smaller than using the design code SD site.

A Study on the On-site Flame Resistant Inspection Method by X-ray Fluorescence Spectrometer (X-선 형광분석기를 이용한 현장방염검사방법에 관한 연구)

  • Kim, Hwang-Jin;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.124-129
    • /
    • 2016
  • According to the current law, on-site flame resistant-treated interior decorations should pass the flame resistant performance test through a 45 degree combustion test from the district fire department. Although a 45 degree combustion test is the most accurate method for determining the flame resistant performance, it can be unreliable when tested on unauthorized samples. To avoid unauthorized sampling, this study suggests on-site flame resistant inspection by X-ray fluorescence spectrometer. Ten types of flame resistant paint were spread on plywoods and MDFs and the components were analyzed by X-ray fluorescence spectrometer. As a result, due to a difference amounts of substances in each paint, each flame resistant paints showed its own characteristic spectrum and the contents of each substance could be determined. On-site flame resistant inspections can be used efficiently when institutional procedures are created.

Detection of Limesilicate Cavities by 3-D Resistivity Survey (3차원 전기비저항탐사에 의한 석회암 공동탐지)

  • Park, Sam-Gyu;Yi, Myeong-Jong;Kim, Chang-Ryol;Son, Jeong-Sul;Kim, Jung-Ho;Cho, Seong-Jun;Seo, Goo-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.147-152
    • /
    • 2006
  • In this study, we examined the applicability of three-dimensional electrical resistivity survey to detect underground cavities of ground subsidence area at the field test site, located at Yongweol-ri, Muan-gun in Korea. Underground cavities are widely present within the limesilicate bedrock overlain by the alluvial deposits in the area of the test site where the ground subsidences have occurred in the past. The limesilicate cavities are mostly filled with groundwater and clays in the test site. Thus, cavities have low electrical resistivity compared to the surrounding host bedrock. The results of the study have shown that the zones of low resistivity correspond to the zones of the cavities identified in the boreholes at the site, and that the three-dimensional electrical resistivity survey used are very effective to detect underground cavities.

  • PDF

The Relationship Between Hydrogen Trapping Behavior and SSCC Suceptibility of API X60/65 Grade Steels

  • Lee, Jae Myung;Kim, Jin Suk;Kim, Kyoo Young
    • Corrosion Science and Technology
    • /
    • v.2 no.3
    • /
    • pp.109-116
    • /
    • 2003
  • It is well known that SSCC (sulfide stress corrosion cracking) is caused by drastic ingression of hydrogen during the service and accumulation of hydrogen near the potential crack initiation site in the material. It is important to characterize the hydrogen trapping behavior to evaluate the service performance of the high strength pipeline steels. In this study. the relationship between the hydrogen trapping behavior and SSCC susceptibility is evaluated in terms of alloy composition, microstructure and carbide behavior. The hydrogen trapping behavior was measured by electrochemical hydrogen permeation test cell (Devanathan cell). The SSCC susceptibility is evaluated by constant extension rate test and constant strain lest method. The hydrogen trapping behavior is affected greatly by microstructure and nature of carbide particles. The fine TiC, and NbC in the matrix of ferritic structure acts as strong irreversible trap sites whereas the bainitic structure acts as reversible trap site. The SSCC susceptibility is closely related to not only the hydrogen trapping behavior but also the loading condition. As the activity of reversible trap site increases, SSCC susceptibility decreases under static loading condition below yield strength, whereas SSCC susceptibility increases under dynamic loading condition or above yield strength. As the activity of irreversible trap site increases. SSCC susceptibility increases regardless of loading condition. It is cased by the mixed effect of dislocation on hydrogen diffusion and trapping behavior.