• 제목/요약/키워드: Test Site

검색결과 3,367건 처리시간 0.031초

AN INVESTIGATION INTO RADIATION LEVELS ASSOCIATED WITH DISMANTLING THE KOREA RESEARCH REACTOR

  • Choi, Geun-Sik;Kim, Hee-Reyoung;Han, Moon-Hee
    • Nuclear Engineering and Technology
    • /
    • 제42권4호
    • /
    • pp.468-473
    • /
    • 2010
  • We confirmed that the dismantling of two research reactors with thermal power of $2MW_{th}$ and $100kW_{th}$, respectively, reveals no significant difference between the radiation levels of the research reactor site and the surrounding environment far away from it, from the radiation level aspect. Radiation dose and radioactivity were measured at monitoring points around the research reactor site of the Korea Atomic Energy Research Institute (KAERI) in Seoul and comparison points 0.5 km to 3.3 km from the site. To grasp trends in the radiation levels during dismantling from the end of 2002 to the end of 2007, the gamma radiation dose rate, the accumulated dose, and the radioactivity of the strontium, tritium, and gamma isotopes were statistically treated and estimated. The averages of these items between the two groups, the research reactor site and comparison points, were assessed by applying a T-test with a significance level of 0.05. P-values found by using the T-test were from 0.12 to 0.83 where the values were much higher than the significance level. As a result, no difference was observed between the radiation levels at the research reactor site and at the comparison points by this T-test. This study showed that dismantling activity of the Korea Research Reactor of the Seoul site did not expose the public or the environment to harmful levels of radiation.

암반 등급분류를 위한 기초 물성조사 보고서 (Basic properties survey report on the rock classification)

  • 허진
    • 기술사
    • /
    • 제24권3호
    • /
    • pp.43-50
    • /
    • 1991
  • On the ground foundation works for Bldg site, Rock classification test can be obtained as follows due to the International Society for Rock Mechanics. 1. In-take test ; Compression strength, Point load test. 2. In-situ test : Schmidt hammer test. Burden test finaly the convinient co-relation table between strength and S.H. test were carried out for site-engineer. This project is one of contineous works regarding to Burden test from Jack leg drill( ø 36mm) to Crawler drill( ø 75mm) use.

  • PDF

암반 분류 기초 물성조사 (Basic properties survey report on the rock classification)

  • 허진
    • 화약ㆍ발파
    • /
    • 제9권3호
    • /
    • pp.10-16
    • /
    • 1991
  • On the ground foundation works for Bldg site, Rock classification test can be obtained as follows due to the International Society for Rock Mechanics. 1. In-situ test : Compressive strength, Point load test. 2. In-situ test Schmidt hammer test. Burden test finaly the convinient co-relation table between strength and 5. H, test were carried out for site-engineer, This project is one of contineous works regarding to Burden test from Jack leg drill($\phi{\;}75mm$) use.

  • PDF

고속도로 갓길 외측 성토상단의 잡초침입 억제를 위한 시험 연구 (The Study on Test for Control of Weeds Invasion in Constructed on Upper Embankment in the Shoulder of a Expressway)

  • 전기성
    • 한국환경복원기술학회지
    • /
    • 제18권6호
    • /
    • pp.227-237
    • /
    • 2015
  • From January 2013 to October 2015, weed invasion control techniques was tested in the test road of Jungbunaeryuk expressway so as to collect preliminary data for the management methods of the upper exterior banking of expressway shoulders. Then, monitoring was conducted and its results are as follows. Mat (sheet), solidifying agent, and mulching (wood chips) were applied for the test and their initial effects of preventing weed invasion were all excellent. It was found that the homogeneity of the wood chip mulching method needs to improve. In the mat method and the mulching method were found to have the most excellent economic feasibility and aesthetics, respectively. The covering degree was found to be the highest at 80% in the control site, followed by the wood chip site at 20% and the solidifying agent site and the non-woven fabric site at 5% each. As for species diversity, the control had the largest variety of species. Two years after the construction, many different species of plants invaded and were growing. Plants including weed didn't tend to invade the slopes applied with non-woven fabric. In addition, weed didn't invade the solidifying agent site and the aesthetics of the upper exterior banking of expressway shoulders was found to be excellent. The wood chip site was found to require consistent management for preventing weed invasion. The mat (sheet) site, the solidifying agent site, and the wood chip mulching site were found to have excellent weed prevention effects. As time passed, the mat (sheet) site and the solidifying agent site showed better weed prevention effects. However, they need consistent monitoring for further application.

노후아파트 현장에서의 콘크리트 압축강도 추정 (Concrete Compressive Strength Prediction from Deteriorating Apartment Site)

  • 이규동;임홍철;임병호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 춘계학술논문 발표대회 제6권1호
    • /
    • pp.155-158
    • /
    • 2006
  • Deduction of compressive strength in concrete members is very important to decide stability of structures. In this study, we compare the compressive strength of concrete between nondestructive test done to the building which was to be demolished at residential reconstruction site and destructive test of core specimen from the site. The result is more reliable because ore can compare the measurement of nondestructive tell with the result from destructive test using drilled cores. Compressive strength of each material was calculated with the result of rebound number test. In addition, we performed ultrasonic test for another result of compressive strength. And we made a comparative study of compressive strength of concrete drawn from both nondestructive and destructive tests.

  • PDF

야회시험장의 시험장감쇠량 (Site Attenuations of an Open Area Test Site)

  • 김기채;정연춘;정정환;정낙삼
    • 대한전자공학회논문지
    • /
    • 제27권9호
    • /
    • pp.1336-1343
    • /
    • 1990
  • In this paper the theoretical analysis of the site attenuation was made on the concept of mutual impedance of antennas and the cause of characteristic hump in the site attenuation curve below 80 MHz is explained. The deviation between the FCC site attenuatios and the experimental results of an ideal open area test site at low frequencies(below 80MHz) was found to be the mutual coupling effects of the antennas under the FCC's measurement conditions. It seems desirable that the site attenuations curve of FCC document be revicused to the theoretical curves presented in this paper is long as the FCC's measurement conditions are to the applied.

  • PDF

A New Multi-site Test for System-on-Chip Using Multi-site Star Test Architecture

  • Han, Dongkwan;Lee, Yong;Kang, Sungho
    • ETRI Journal
    • /
    • 제36권2호
    • /
    • pp.293-300
    • /
    • 2014
  • As the system-on-chip (SoC) design becomes more complex, the test costs are increasing. One of the main obstacles of a test cost reduction is the limited number of test channels of the ATE while the number of pins in the design increases. To overcome this problem, a new test architecture using a channel sharing compliant with IEEE Standard 1149.1 and 1500 is proposed. It can significantly reduce the pin count for testing a SoC design. The test input data is transmitted using a test access mechanism composed of only input pins. A single test data output pin is used to measure the sink values. The experimental results show that the proposed architecture not only increases the number of sites to be tested simultaneously, but also reduces the test time. In addition, the yield loss owing to the proven contact problems can be reduced. Using the new architecture, it is possible to achieve a large test time and cost reduction for complex SoC designs with negligible design and test overheads.

원전용 안전등급 밸브의 현장 폐쇄기밀시험 기술에 대한 연구 (Research on the on-site Seat Test Technology for the nuclear safety related valves)

  • 정환석;김태성
    • 한국압력기기공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.8-17
    • /
    • 2021
  • The seat leakage test is required after the maintenance work on the valve seat. Either the test has been performed outside of the plant after cutting the valve from the pipe system or the simplified test has been performed so far. It was unable to perform the test at the plant site because it is hard to make a steady pressure on the valve inlet when it is installed in the pipe. This research aims to perform the leakage test in the nuclear power plant while it is installed in the pipe system. The mock-up test is performed by pressurizing the leak-off pipe on the valve body. The result is compared with traditional test result by pressurizing the valve inlet. Furthermore the chamber mock-up tests are performed under various conditions. The leak rate by the developed test using the leak-off pipe is found to be similar but greater than the leak rate by the existing test method. It implies that the test using the leak-off pipe is more conservative than the existing test. The methodology and the equipment which this paper suggests that on-site seat test is possible and the application of the technology could reduce the time and cost for the valve maintenance work significantly.

가스하이드레이트 시험생산 기술개발 동향 (An Investigation on the Technical Progress of Test Production for Gas Hydrate Development)

  • 박승수;주우성;안승희;이정환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.705-708
    • /
    • 2009
  • For the Gas hydrate Research and Development in Korea, the prospect area I & II was surveyed and drilled during the first phase. At the result, we succeeded to discovering gas hydrate real sample at BSR reflection and vent structure. This expedition processing contributes to developing the offshore seismic survey technologies and data processing of Korea. But Korean gas hydrate test production research, in spite of activating test production at other countries, is such a limitation about technician, GH production technologies and E&P processing. First of all, there is no exist in Korea to application site for the their production research results. In this paper, we have studied the gas hydrate reservoir selection technics of the DOE & BPXA for the ANS test production. And this result will helpful to preparation of gas hydrate test production in Korea.

  • PDF

기계화시공에 의한 보수재료의 현장품질관리확립을 위한 실험적 연구 (An Experimental Study for Establishment of On-Site Quality Control of Repair Material by the mechanized construction)

  • 조봉석;장재봉;김용로;강석표;홍성윤;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.160-163
    • /
    • 2004
  • In domestic, various repair materials and method systems to keep up with these reinforced concrete deteriorated due to salt damage, carbonation, chemical decay et. developed and applied. However, on-site quality control of various repair materials and method systems isn't achieved desirably because it is depend completely on a men of experience' opinions above all else regardless of various on-site environments. In this background, mock up test with due regard to real on-site environments was performed to secure fundamental data for establishment of desirable on-site quality control. Mock up test using repair mortar analyzed from angles of construction methods, mechanical spraying pressures, W/M. Construction methods were designed manpower method and spraying method, spraying pressures were designed 32, 42, 52 psi, W/M were designed 14.4, 15.4, $16.4\%$. And compressive strength, Chloride ion diffusion coefficient, bond strength, SEM. of mock up test specimens were evaluated. In conclusion, we confirmed excellency of mechanical spraying pressures, fined extremely excellency of condition of spraying pressure 42 ps, W/M $14.4\%$ within this study. therefore the results of this study will be useful to provide fundamental data for establishment of desirable on-site quality control.

  • PDF