• Title/Summary/Keyword: Test Sequence

Search Result 1,291, Processing Time 0.027 seconds

Design and Application of the TFM Based System Test Model for the Weapon System Embedded Software (무기체계 임베디드 소프트웨어에 대한 TFM 기반 시스템 테스트 모델 설계 및 적용)

  • Kim, Jae-Hwan;Yoon, Hee-Byung
    • The KIPS Transactions:PartD
    • /
    • v.13D no.7 s.110
    • /
    • pp.923-930
    • /
    • 2006
  • In this paper we design the system test model for the weapon system embedded software based on the Time Factor Method(TFM) considering time factors and suggest the results through the case study. For doing this, we discuss the features, system tests and the object-oriented model based UML notations of the weapon system embedded software. And we give a test method considering time factors, a measuring method to time factors, and a test case selection algorithm as an approach to the TFM for designing the system test model. The TFM based system test model consists of three factors (X, Y, Z) in the weapon system embedded software. With this model, we can extract test cases through the selection algorithm for a maximum time path in 'X', identify the objects related to the Sequence Diagram in 'Y' and measure the execution time of each objects which is identified by the Timing Diagram in 'Z' Also, we present the method of extracting the system test cases by applying the proposed system test model to the 'Multi-function missile defense system'.

Validation of sequence test method of Pb-free solder joint for automotive electronics (자동차 전장품용 무연솔더 접합부의 시리즈 시험 유효성)

  • Kim, A Young;Oh, Chul Min;Hong, Won Sik
    • Journal of Welding and Joining
    • /
    • v.33 no.3
    • /
    • pp.25-31
    • /
    • 2015
  • Due to environmental regulations (RoHS, WEEE and ELV) of the European Union, electronics and automotive electronics have to eliminate toxic substance from electronic devices and system. Specifically, reliability issue of lead-free solder joint have an increasing demand for the car electronics caused by ELV banning. The authors prepared engine control unit and cabin electronics soldered with Sn-3.0Ag-0.5Cu (SAC305). To compare with the degradation characteristics of solder joint strength, thermal cycling test (TC), power-thermal cycling test (PTC) and series tests were conducted. Series tests were conducted for TC and PTC combined stress test using the same sample in sequence and continuously. TC test was performed at $-40{\sim}125^{\circ}C$ and soak time 10 min for 1000 cycles. PTC test was applied by pulse power and full function conditions during 100 cycles. Combined stress test was tested in accordance with automotive company standard. Solder joint degradation was observed by optical microscopy and environment scanning electron microscopy (ESEM). In addition, to compare with deterioration of bond strength of quad flat package (QFP) and chip components, we have measured lead pull and shear strength. Based on the series test results, consequently, we have validated of series test method for lifetime and reliability of Pb-free solder joint in automotive electronics.

Addition of an N-Terminal Poly-Glutamate Fusion Tag Improves Solubility and Production of Recombinant TAT-Cre Recombinase in Escherichia coli

  • Kim, A-Hyeon;Lee, Soohyun;Jeon, Suwon;Kim, Goon-Tae;Lee, Eun Jig;Kim, Daham;Kim, Younggyu;Park, Tae-Sik
    • Journal of Microbiology and Biotechnology
    • /
    • v.30 no.1
    • /
    • pp.109-117
    • /
    • 2020
  • Cre recombinase is widely used to manipulate DNA sequences for both in vitro and in vivo research. Attachment of a trans-activator of transcription (TAT) sequence to Cre allows TAT-Cre to penetrate the cell membrane, and the addition of a nuclear localization signal (NLS) helps the enzyme to translocate into the nucleus. Since the yield of recombinant TAT-Cre is limited by formation of inclusion bodies, we hypothesized that the positively charged arginine-rich TAT sequence causes the inclusion body formation, whereas its neutralization by the addition of a negatively charged sequence improves solubility of the protein. To prove this, we neutralized the positively charged TAT sequence by proximally attaching a negatively charged poly-glutamate (E12) sequence. We found that the E12 tag improved the solubility and yield of E12-TAT-NLS-Cre (E12-TAT-Cre) compared with those of TAT-NLS-Cre (TAT-Cre) when expressed in E. coli. Furthermore, the growth of cells expressing E12-TAT-Cre was increased compared with that of the cells expressing TAT-Cre. Efficacy of the purified TAT-Cre was confirmed by a recombination test on a floxed plasmid in a cell-free system and 293 FT cells. Taken together, our results suggest that attachment of the E12 sequence to TAT-Cre improves its solubility during expression in E. coli (possibly by neutralizing the ionic-charge effects of the TAT sequence) and consequently increases the yield. This method can be applied to the production of transducible proteins for research and therapeutic purposes.

Identification of Colletotrichum spp. associated with pepper anthracnose in Korea (oral)

  • Kim, Joon-Tae;Park, Soo-Kyoung;Park, Woobong;Lee, Yong-Hwan;Kim, Heung-Tae
    • Proceedings of the Korean Society of Plant Pathology Conference
    • /
    • 2003.10a
    • /
    • pp.125.1-125
    • /
    • 2003
  • Pepper anthracnose is one of the major limiting factors in pepper production. Boring last over 10 years, Colletotrichum gloeosporioides has been known as the most prevalent species among five Colletotrichum spp. involved as anthracnose causing agents. Recently, however, the change of major species with pepper anthracnose has been proposed. Identification study was peformed on 12 test isolates collected from anthracnose disease symptoms on pepper during 2001-2002 and 25 reference isolates obtained from several other host plants. The identification of the isolates with morphological observation and IfS region sequence comparison resulted that 11 ones from 12 test isolates colleted from pepper anthracnose during 2001-2002 were identified as C. acutatum. PCR using species-specific primers designed from ITS region sequence suggested a rapid diagnosis method in identifying C. acutatum from C. gloeosporioides.

  • PDF

Video quality assessment of digital TV for direct broadcasting satellite (직접 위성 방송을 위한 디지틀 TV의 화질 평가)

  • 박대철;김경태;전현호;채종석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.6
    • /
    • pp.1370-1378
    • /
    • 1996
  • A subjective video quality assessment methods are proposed based on CCIR Rec. 500-5 for an evaluation and testing of compressed video quality and performance of video codec to be designed in accordance with the MPEG-2 MP ML specification which is adapted as a DTV standard for Korea digital DBS. Video sequence compressed in compliance with MPEG-2 MP ML encoding parameterswastested by the proposed video quality evaluation procedure. Test sequence were compressed at the bit rate 6Mbps, 7.5Mbps and 9Mbps, repectively. Test results of the 7.5Mbps bitrate showed a satisfactory picture quality at about 4.0 on the 5.0 absolute scale of ITU-R 500-5.

  • PDF

Analysis on Initial Stability Test Results of Underwater Vehicle Using the HR Propulsion System (HR추진기관을 이용한 수중운동체의 초기안정성 시험 결과 분석)

  • Hwang, Heeseong;Kim, Hakseong;You, Youngjoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.1142-1143
    • /
    • 2017
  • In this paper, Underwater propulsion test of SWASH(Small Waterplane Area Single Hull) type underwater vehicle with hybrid rocket system is performed. Watertight structure is applied to prevent a combustion chamber from water, and the control logic is constructed by setting the watertight ignition sequence. As a results, It is confirmed that the ignition is stable in water, and the propulsion system works well along the configured control sequence.

  • PDF

Fault Diagnosis in the CA Analyzer and Fault Detection of the Input Sequence (CA 분석기의 오류진단과 오류가 있는 입력수열의 오류탐지)

  • Cho, Sung-Jin;Kwon, Min-Jeong;Yim, Ji-Mi;Kim, Jin-Gyoung;Park, Young-Gyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.10
    • /
    • pp.2129-2139
    • /
    • 2009
  • In this paper, we diagnose the fault in the CA analyzer by setting up the initial value such that the final test signature is a constant regardless of the circuit being tested. This method makes the CA test procedure short and clear. In addition, we detect the fault of the faulty input sequence by using the inverse matrix of the CA state transition matrix.

A newly recorded sea urchin, Araeosoma owstoni Mortensen, 1904 (Echinoidea; Echinothurioida; Echinothuriidae), from the Korea Strait

  • Lee, Taekjun;Shin, Sook
    • Journal of Species Research
    • /
    • v.11 no.3
    • /
    • pp.188-193
    • /
    • 2022
  • Araeosoma owstoni Mortensen, 1904, a newly recorded sea urchin, was collected from the Korea Strait by trawling during a research expedition in April 2017. The specimen was damaged and was severely peeled off on the aboral side during trawling. However, a test and the surface of the oral side of the sample were well preserved, allowing us to successfully identify it. The species was distinguished by the large and flexible test, the tiny apical section, and the interambulacra width which is twice of the ambulacra. Pedicellaria tridentate and triphyllous were presents, but tetradactyle pedicellaria was absent due to severe peeling on the aboral side. Moreover, a length of 1,212 bp sequence from mitochondrial COI gene was obtained and this sequence covered the general DNA barcoding region. The mean of interspecific divergence within A. owstoni from Korea and other eight species of Araeosoma from the GenBank was 6.8%. This value indicated that our species was clearly distinguishable from the others. Thus, the first Araeosoma species occurring in South Korea is presented in this study.

Minimum Entropy Deconvolution을 이용한 지하수 상대 재충진양의 시계열 추정법

  • 김태희;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.574-578
    • /
    • 2003
  • There are so many methods to estimate the groundwater recharge. These methods can be categorized into four groups. First groupis related to the water balance analysis, second group is concerned with baseflow/springflow recession, and third group is interested in some types of tracers; environmental tracers and/or temperature profile. The limitation of these types of methods is that the estimated results of recharge are presented in the form of an average over some time period. Forth group has a little different approach. They use the time series data of hydraulic head and specific yield evaluated from field test, and the results of estimation are described in the sequential form. But their approach has a serious problem. The estimated results in forth typeof methods are generally underestimated because they cannot consider the discharge phase of water table fluctuation coupled with the recharge phase. Ketchum el. at. (2000) proposed calibrated method, considering recharge- and discharge-coupled water table fluctuation. But the dischargeis considered just as the areal average with discharge rate. On the other hand, there are many methods to estimate the source wavelet with observed data set in geophysics/signal processing and geophysical methods are rarely applied to the estimation of groundwater recharge. The purpose this study is the evaluation of the applicability of one of the geophysical method in the estimation of sequential recharge rate. The applied geophysical method is called minimum entropy deconvolution (MED). For this purpose, numerical modeling with linearized Boussinesq equation was applied. Using the synthesized hydraulic head through the numerical modeling, the relative sequenceof recharge is calculated inversely. Estimated results are very concordant with the applied recharge sequence. Cross-correlations between applied recharge sequence and the estimated results are above 0.985 in all study cases. Through the numerical test, the availability of MED in the estimation of the recharge sequence to groundwater was investigated

  • PDF

Penetration Characteristics of CFRP Laminated shells according to Stacking Sequence and Curvature (CFRP 적층쉘의 적층구성 및 곡률 변화에 따른 관통 특성)

  • Cho Young Jea;Kim Young Nam;Yang In Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.2
    • /
    • pp.164-171
    • /
    • 2005
  • This study aims to examine an effect of stacking sequence and curvature on the penetration characteristic of a composite laminated shell. For the purpose, we manufactured specimens with different stacking sequences and curvatures, and conducted a penetration test using an air-gun. To examine an influence according to stacking sequence, as flat plate and curvature specimen had more plies, their critical penetration energy was higher, Critical penetration energies of specimen A and C with less interfaces somewhat higher than those of B and D with more interfaces. The reason that with less interfaces, critical penetration energy was higher is pre-impact bending stiffness of composite laminated shell with less interfaces was lower than that of laminated shell with more interfaces, but bending stiffness after impact was higher. And it is because interface, the weakest part of the composite laminated shell, was influenced by transverse impact. As curvature increases, critical penetration energy increases linearly. It is because as curvature increases, resistance to in-plane deformation as well as bending deformation increases, which need higher critical penetration energy. Patterns of cracks caused by penetration of composite laminated shells include interlaminar crack, intralaminar crack, and laminar fracture. A 0$^{\circ}$ply laminar had a matrix crack, a 90$^{\circ}$ply laminar had intralaminar crack and laminar fracture, and interface between 0$^{\circ}$and 90$^{\circ}$laminar had a interlaminar crack. We examined crack length and delamination area through a penetration test. For the specimen A and C with 2 interface, the longest circumferential direction crack length and largest delamination area were observed on the first interface from the impact point. For the specimen B and D with 4 interface, the longest crack length and largest delamination area were observed on the third interface from the impact point.