• Title/Summary/Keyword: Test Cost

Search Result 3,991, Processing Time 0.032 seconds

Test Item Prioritizing Metrics for a Selective Software Testing (차별화된 소프트웨어 시험을 위한 시험항목 우선순위 조정)

  • Lee, Jae-Ki;Lee, Jae-Jeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.1B
    • /
    • pp.38-47
    • /
    • 2008
  • The system test was accomplished in delivery time for a suitable of various requirements at the software market. Especially, critical faults must be detected and removed for a close main functions and users against target system. In generally, proposed test methods are executed with a calendar time, not a competitive and effectiveness method as selective software testing. These methods are inapplicable to short term test or early system development stage. Moreover, it's accompanied by heavy cost. Overcoming of these problems, must attempted to new software test method role of core function in the system test. Selective software testing method is decided to mixing with the three-information such as a frequency, complexity of use scenario and fault impact. Using this information, searching a fatal error and usefully system test for an executed test scenario. In this paper, we have proposed new test method and verified testing results for the detection of critical faults or search a fatal errors with a system main function.

A Study on the Precautions Effects of the Enclosure Integrity Test for the Gaseous Extinguishing Systems: Focusing on the Power Plant (가스계 소화설비의 밀폐도 시험에 영향을 미치는 사전조치에 관한 연구: 발전소를 중심으로)

  • Kim, Young-Chul;Jo, Il-Hyun;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.60-66
    • /
    • 2015
  • The present study was aimed to analyze enclosure integrity test, which is the performance experiment of soaking time, in a fire zone equipped with gaseous extinguishing system in an effort to find understand the effect of precaution factors upon the success of fire extinguishment. To achieve the goal of this study, it divided the fire zones of internal and external power plants into ones taking precaution measures and not taking them and then enclosure integrity test was given respectively. Therefore, this study examined the success rate if the test according to the presence and absence of the precaution measure and confirmed the failure factors, designed concentration soaking time and proportion of leakage area to total volume area by type of gaseous extinguishing system and rooms. Precaution measures were applied to the fire zones without them to confirm the increase of the success rate of enclosure integrity test. By doing so, it was found that reduced number of experiments caused by failure led to cost saving.

Implementation of Test Automation Agent for DO-330 Tool Qualified of ARINC-661 Development Tool (ARINC-661 개발 도구의 DO-330 도구 자격 획득을 위한 시험 자동화 에이전트 구현)

  • Kim, Do Gyun;Kim, Younggon
    • Journal of Platform Technology
    • /
    • v.8 no.4
    • /
    • pp.47-58
    • /
    • 2020
  • DO-330 Software Tool Qualification Considerations is a guideline for development of tools used to develop/verify software and hardware installed on aircraft. And among several processes, the verification process is very crucial as it occupies a large proportion for DO-330. Especially, in order to qualify tool with high safety level, test objectives must be performed with independence, accordingly, more time, cost, and manpower are required than other objectives. In addition, even if the test cases or test procedures are well defined, the higher the complexity of the test the higher probability of human error occurs. In this paper, we propose Script-based Test Automation Agent software structure for efficient DO-330 verification process of A661UAGEN tool developed by Hanwha Systems. Compared to the test performed manually by the test engineer, testing time of the Script-based Test Automation Agent is reduced by 87.5% and testing productivity is increased by 43.75%.

  • PDF

Experimental Study on the Calibration of Bi-directional High Pressure Pile Load Test (양방향 고유압 말뚝재하시험장치의 보정에 관한 실험적 연구)

  • Choi, Yongkyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5C
    • /
    • pp.303-311
    • /
    • 2008
  • In the case of bi-directional high pressure pile load test with double-acting jack, the shortcomings of bi-directional pile load test with single-acting jack could be solved, low-cost of test could be sure, the limits of loading capacity could be overcome and quality assurance of service plie could be confirmed. In this study, to confirm the stability, the reliability and the application of bi-directional high pressure pile load test with double-acting jack, the calibration test for high pressure oil jacks, the length of high pressure hose and tunable high pressure pipe system were performed. As a result, credibility was very high because the reliability of test results was approached at about 1.0.

Development of Historical Data Selection Model Using Non-parametric test in Public Sector - focused on Reinforced Concrete Works of Multi-housing Projects - (비모수 검정기반 공공부문 실적단가 선정모델 개발 -공동주택 철근콘크리트 공종을 중심으로-)

  • Lee, Hyun-Ki;Jeon, Jae-Yong;Park, Sung-Chul;Hong, Tae-Hoon;Koo, Kyo-Jin;Hyun, Chang-Taek
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.1
    • /
    • pp.87-95
    • /
    • 2008
  • The government wants to apply the construction cost estimating method based on historical data published in the first six months of 2004. Construction companies, however, require the proposed cost estimation model, to be improved which makes it difficult to predict a reasonable construction costs. This paper presents an improved historical data selection model after analyzing the problem of previous method throughout comparing contracted unit prices of reinforced concrete works selected by the previous model to market prices. The model which can select more feasible data would assist participates such as general contractors and sub-contractors to earn a proper profits.

Nonlinear Structure-Soil Interaction Analysis for the Suction Bucket Foundation of Offshore Wind-Turbine (해상풍력 석션버켓 기초 구조-지반 상호작용 비선형 구조해석 및 실험결과 비교)

  • Jin, Jeongin;Kim, Donghyun;Jung, Minuk
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.469-475
    • /
    • 2016
  • As we are facing the shortage of oil energy, studies on renewable energy, wind energy research has been naturally getting attention. Among wind energies, ocean wind energy is relatively abundant compared to land wind energy and therefore, is getting much attention in terms of its efficiency. However, the problem is the cost. Generally, the cost ratio of the supporting structure is over 25% of the total installation cost of a offshore wind turbine system. Thus, it is very important to reduce the total installation cost of the offshore wind turbine and develop accurate analysis methodology for various offshore wind turbine foundations. In this study, nonlinear structure-soil interaction analyses have been proposed and conducted for the typical suction bucket model of an offshore wind turbine foundation, and the results were compared with experimental test data for numerical validations.

The Development of Low Cost Power Components Measurement and Record System for Monitoring Electrical Equipment Operation Status (전력설비 동작 상태 감시를 위한 저가형 전력 성분 측정 및 기록 시스템의 개발)

  • Jeon, Jeong-Chay;Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4855-4862
    • /
    • 2015
  • This paper proposes low price power component measurement and record system for preventing electrical safety accident and supporting accident cause analysis by periodically monitoring and recording the operation status of electrical equipments. The proposed system was designed by mainly using parts to measure accurate power component but reduce cost. Especially, low cost and high effectiveness system implementation was possible by using MAXIM 78M6631 to calculate power components in the definition of IEEE Standard 1459-2010 related power quality. The measurement performance of the developed system is tested by using standard devices such as YOKOGAWA power analyzer WT1600. The test results showed that accuracy of the developed system is less than 0.5 % and the developed system is tested in a real area to verify the operation reliability and remote monitoring performance of the system over 6 months.

Improvement of the Standard Cost of Development Charge System in Jeju (개발부담금제도에 따른 제주지역의 표준비용 산정 개선방안)

  • Hong, Seung-Jong;Lee, Dong Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.1421-1429
    • /
    • 2015
  • During the six years from 2006 to 2011, based on a study of projects with an area equivalent to or less than $2,700m^2$ located in Jeju self-governing province, it was shown, through comparison with the pre-existing calculation methods, that there were many problems with the application of the standard cost. Accounting for the uniqueness of Jeju province, the study suggested an alternative method for applying the standard cost, basing it on property usage of either urban area or non-urban area pursuant to the National Land Planning and Utilization Act rather than land type of either mountain area or non-mountain area, with the utilization of T-test and ANOVA raising the reliability of this study.

The Tests of Free Cash Flows Hypothesis about Stock Repurchase (자사주매입에 관한 잉여현금흐름가설 검정)

  • Shin, Min-Shik;Lee, Jung-Suk
    • The Korean Journal of Financial Management
    • /
    • v.24 no.1
    • /
    • pp.59-83
    • /
    • 2007
  • In this paper, we test empirically free cash flows hypothesis about stock repurchase. The main results of this study can be summarized as follows. First, repurchasing firms do not experience a growth in profitability relative to their peer firms. Second, repurchasing firms experience a contraction in their investment opportunity, and so capital expenditures and cash reserves decline after the repurchase. Third, repurchasing firms experience a decline in systematic risk and investments and in their cost of capital. Fourth, the reduction in profitability and cost of capital are sources of the positive market reaction to the repurchase announcement. And the market reaction to stock repurchase announcements is stronger among those firms that are more likely to overinvest. Conclusively, these results support free cash flows hypothesis. When firms experience a decline in profitability, capital expenditures and cash reserves, systematic risk and cost of capital, they decide to repurchase stocks to reduce free cash flows.

  • PDF

Weld Quality Monitoring System Development Applying A design Optimization Approach Collaborating QFD and Risk Management Methods (품질 기능 전개법과 위험 부담 관리법을 조합한 설계 최적화 기법의 용접 품질 감시 시스템 개발 응용)

  • Son, Joong-Soo;Park, Young-Won
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.2
    • /
    • pp.207-216
    • /
    • 2000
  • This paper introduces an effective system design method to develop a customer oriented product using a design optimization process and to select a set of critical design paramenters,. The process results in the development of a successful product satisfying customer needs and reducing development risk. The proposed scheme adopted a five step QFD(Quality Function Deployment) in order to extract design parameters from customer needs and evaluated their priority using risk factors for extracted design parameters. In this process we determine critical design parameters and allocate them to subsystem designers. Subsequently design engineers develop and test the product based on these parameters. These design parameters capture the characteristics of customer needs in terms of performance cost and schedule in the process of QFD, The subsequent risk management task ensures the minimum risk approach in the presence of design parameter uncertainty. An application of this approach was demonstrated in the development of weld quality monitoring system. Dominant design parameters affect linearity characteristics of weld defect feature vectors. Therefore it simplifies the algorithm for adopting pattern classification of feature vectors and improves the accuracy of recognition rate of weld defect and the real time response of the defect detection in the performance. Additionally the development cost decreases by using DSP board for low speed because of reducing CPU's load adopting algorithm in classifying weld defects. It also reduces the cost by using the single sensor to measure weld defects. Furthermore the synergy effect derived from the critical design parameters improves the detection rate of weld defects by 15% when compared with the implementation using the non-critical design parameters. It also result in 30% saving in development cost./ The overall results are close to 95% customer level showing the effectiveness of the proposed development approach.

  • PDF