• Title/Summary/Keyword: Test Cost

Search Result 3,991, Processing Time 0.037 seconds

Outdoor Weathering Test for used Construction Urethane Type Sealants (건축용 우레탄 실란트의 옥외폭로시험평가 방법 개발)

  • Lee, Sang Kook;Bae, Kee Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.69-70
    • /
    • 2017
  • In Korea, silicone type sealant is widely used for construction site. Before the silicone type, urethane type is one of the main type sealants. However, the weathering property is less than the silicone type, the urethane type is replace by the silicone one. Still the urethane type is used for the inside of the buildings for the perimeter of the window. The silicone type sealants are better in weathering property than those of the urethane type sealants. Except the weathering property urethane type sealant has its own advantage like movement property, low cost and so forth. There are many research results for the outdoor weathering of the sealants, but in Korea there are no results for the outdoor weathering for construction sealants. This research is focused on the outdoor weathering of the urethane sealants, how to measure the degradation, and compare the products which used in Korea. The outdoor weathering test is usually time consuming, thus we designed specialized device for accelerating the result.

  • PDF

Transport Capacity Design and Characteristics Evaluation of Al/Cu Composite Busbar for Power Equipments (전력기기용 Al/Cu 복합 부스바의 통전용량 설계 및 특성 평가)

  • Bae, Joon-Han;Kim, Hae-Joon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.12
    • /
    • pp.628-632
    • /
    • 2006
  • This paper deals with the electric and thermal characteristics of the composite busbar composed of aluminum and copper. When AC current is flowing in Cu busbar used widely in conservative equipments like power cable, transformer, and switchgear & controlgear most current is concentrated on the surface of the busbar by the skin effect. Therefore, if the Cu region in the busbar having low current density is replaced with aluminum, we can largely reduce the product cost and weight of the busbar. To conform the performance of the composite busbar, we designed and fabricated a test Al/Cu composite busbar. Maximun temperature rise of the busbar was $35^{\circ}C$ when 1600 Arms of AC current was applied to the test composite busbar($120mm{\times}10mm$). Based on test results, we can expect to make the low-priced and light power equipments using the Al/Cu composite busbar.

TEST MODEL OF MILLIMETER-WAVE IMAGING RADIOMETER EQUIPMENT (MIRAE)

  • Lee, Ho-Jin;Kim, Won-Gyum;Seong, Jin-Taek;Kim, Dae-Suk;Na, Kyoung-Tae;Jung, Min-Kyoo;Chang, Yu-Shin;Kim, Soon-Tae;Kim, Yong-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.365-368
    • /
    • 2007
  • Millimeter-wave (MMW) imaging radiometer systems have an attractive advantage to obtain an image through low visibility weather conditions such as fog, clouds and light rain compared with visible and infrared imaging systems. Many countries have developed a various kinds of MMW imaging radiometers for the aim of low cost and high performance. In Korea, Millimeter-wave Imaging RAdiometer Equipment (MIRAE) has been developed since the end of 2006. Recently the development of some modules was finished for the test model. This paper describes the design and development of the MIRAE. In addition, the test results of its manufactured modules are presented.

  • PDF

Investigation and Analysis of Regulations for the Safety of the Noise Barrier (방음벽 안전을 위한 기준 조사 및 분석)

  • Huh, Young;Kim, Heung-Sik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.9
    • /
    • pp.730-734
    • /
    • 2003
  • For the noise reduction measures in a construction field or near the traffic line receiver is often the most economic measure in order to exclude the propagated sound. The dimension of the barrier is decided by the noise and construction design, and the constructive quality of a soundproof panel shall be secured in accordance with KS F4770 to guarantee the safety of sound barriers. In this paper the problems included in the KS F4770-1 that is the regulation for the metallic sound barrier of the absorption type are identified and it is suggested what to be corrected or improved. Through a series of the analyses, conclusions were reached that it is required to improve test methods in KS F4770-1 as well as to break down test loads for building more cost-effective sound barrier.

A Study on the Performance Test of Axial-flow Cyclone Separator (축상유입식 사이클론 집진기 성능시험에 관한 연구)

  • Chin, Do-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.1
    • /
    • pp.101-106
    • /
    • 2020
  • Along with dust collection efficiency, pressure loss is a very important cyclone operation factor. A severe rise in pressure loss causes the problem of cost. To solve the problem, the method connecting axial-vane type cyclones in parallel is suggested recently. The axial vane type cyclone dust collector applied in this study is a small portable type. Multiple cyclones are installed in a round type. The basic performance test on the axial vane type cyclone dust collector was conducted. As a result, the cut size reduced along with a rise in the wind velocity of the cyclone dust collector inlet. According to the test on dust collection efficiency, the effect of dust collection began to appear in the range of 3㎛ and dust collection efficiency was greatly improved at 5 ㎛. The noise of the cyclone dust collector well met the fan sound power level of KSB 6361.

Flame Retardancy & Mechanical Properties of Mixed Waste $Plastic/Mg(OH)_{2}$ Composites Reinforced with PUB Powder (PUB 분말이 충전된 혼합폐플라스틱/$Mg(OH)_{2}$ 복합소재의 난연성 및 기계적 특성)

  • Jung, Ki-Chang;Song, Jong-Hyeok
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.1 s.73
    • /
    • pp.65-71
    • /
    • 2006
  • Flame retardancy and mechanical properties of polyolefinic mixed waste plastics/filler composites were investigated by using inorganic flame retardant(magnesium hydroxide) and PUB(polyurethane block) powder generated from cryogenic insulation process. All composites were obtained by extrusion and after compression molding. The effect of PUB powder on the properties of the composites was studied by tensile and izod impact test, morphology studies and flammability as LOI and UL94 vertical burning test and smoke density. The objective of this work is to obtain good mechanical properties from recycled PP composites with $Mg(OH)_{2}/PUB$ powder as fillers and optimum cost-performance balance, in addition to flame retardant characteristics.

Corrosion Resistance of SD460 Reinforcing Rod by Ceramic Coating (SD460 철근의 세라믹 코팅에 의한 내식성 향상연구)

  • Park, Ki Y.;Lee, Jong K.;Hong, Seok W.
    • Corrosion Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.157-161
    • /
    • 2009
  • The corrosion resistance of reinforcing bar was studied to endure the marine environment during shipment. The red rust on the surface did not damage the adherence in the concrete structures, especially in highly alkaline environment, but made the consumer doubt of the quality. The passivation process by alkalization of the quenching water in the tempcore process failed to endure the long shipping period. The ceramic coating by sol-gel process improved the corrosion resistance without damaging the mechanical properties and adherence between concrete and reinfiorcing bar. Optimal concentration of the coating solution and coating temperature were tested. No additional energy was necessary for the coating process by spraying during cooling process, resulting simplified process and low cost. Salt spray test, cyclic corrosion test and atmospheric test were employed to confirm the resistance. The corrosion rates were presented by rating number and polarization resistance. The coating layer was examined by FIB, XRD and SEM etc.

A Study of In Situ Hydraulic Conductivity Testing Equipments (현장투수시험 장치에 관한 비교 연구)

  • 김현기;권무남
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.612-617
    • /
    • 1999
  • This study was carried orut considering the aspect of economical and measuring time to investigate through the literature review of the test methods and advantage -disadvantage of infilltrometer and porous probe test apparatus. SSRI and BAT permeameter could obtain results within relatively short time and measure low permeability. SDRI is able to obtain values the accuracy and representative of the overall in-situ. BAT permeameter is to suitable because it can obtain the values accurately and quickly . Therefore the apparatus cost can be to disregard. In-situ measurement using in-situ hydralulic conductivity test equipment is able to do for the engineer to quickly identify and remediate problem areas due to construction or material changes.

  • PDF

Investigation and Analysis of Regulations for the Safety of the Sound Barrier (방음벽 안전을 위한 기준 조사 및 분석)

  • Huh, Young;Kim, Heung-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.219-223
    • /
    • 2003
  • For the noise reduction measures in a construction field or near the traffic line receiver is often the most economic measure in order to exclude the propagated sound. The dimension of the barrier is decided by the noise and construction design, and the constructive quality of a soundproof panel shall be secured in accordance with KS F4770 to guarantee the safety of sound barriers. In this paper the problems included in the KS F4770-1 that is the regulation for the metallic sound barrier of the absorption type are identified and it is suggested what to be corrected or improved. Through a series of the analyses, conclusions were reached that it is required to improve test methods in KS F4770-1 as well as to break down test loads for building more cost-effective sound barrier.

  • PDF

A Study on the Improvement of Processing in Telephone Dial through Industrial Engineering Technique (IE 기법에 의한 전화기 다이얼의 공정개선에 관한 연구)

  • 김현석
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.5 no.7
    • /
    • pp.43-48
    • /
    • 1982
  • As the result of processing improvement of Telephone Dial by substituting. Synthetic Resin for metalic materials, improved characteristics of quality can be gained as follow. 1. By the improvement of structure and assembling of the Telephone Dial, the complex process of manufacture can be a simplified one, and at the same time the working process can be done in the form of assembly. 2. In the efficiency test of the Telephone Dial, the noise decreases by 5% compared with the first test. In the test of life and environment, it accords with the standard of the Ministry of Communications and its function betters. 3. By using synthetic resins instead of metalic materials the cost can be reduced by \340 than the first improvement and it also brings the heightend value.

  • PDF