• Title/Summary/Keyword: Test Case Evaluation

Search Result 1,360, Processing Time 0.039 seconds

Accuracy Evaluation and Analysis of SLAM for the Advancement of Forest Investigation (산림조사 고도화를 위한 SLAM의 정확도 평가 및 분석)

  • Yun, Hee-Cheon;Lee, Jong-Sin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.734-739
    • /
    • 2018
  • The National Forestry Inventory of Korea has started the 7th (2016 ~ 2020) survey from the first (1972 ~ 1974) National Forest Situation Survey. The diameter at breast height was measured using a diameter tape, and the tree height was measured using a hypsometer in the National Forestry Inventory of Korea from the 1st to recently the 7th surveying. In the case of the diameter tape, however, irregularly shaped trees may cause a large error. In the case of a hypsometer, the height may be measured indirectly in 10 cm increments to the front edge of the tree, so that the accuracy may be lowered. This paper suggests the use of SLAM to improve the accuracy and advance forest investigations. For this purpose, a test bed for the measurement of DBH and tree height was set up, and the scan data was acquired directly using SLAM equipment. The accuracy of DBH and tree height measurements were analyzed. As a result, it was possible to calculate directly the DBH and tree height to 1mm unit, and it showed that the DBH accuracy of 2cm or less and the accuracy of the tree height accuracy of 1.3cm or less are sufficient for practical use. Based on the results, the scan data will be acquired for sample points and analyzed.

Dose and Image Evaluation according to Changes in Tube Voltage during Chest X-ray Examination according to Automatic Exposure Control (자동노출제어장치 유·무에 따른 흉부 후·전방향 검사 시 관전압 변화에 따른 선량 및 영상평가)

  • Young-Cheol, Joo;Dong-Hee, Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.871-877
    • /
    • 2022
  • This study was conducted to improve the problems of exposure dose and image reading applied to patients due to the incorrect use of AEC during chest radiography. Images were acquired by dividing the case where AEC was used as the test condition and the case where AEC was not used. As a result of the study, the dose was reduced by 1.17% in 110 kVp without AEC than with AEC, 17.2% decrease at 100 kVp, 30.19% decrease at 90 kVp, and 46.45% decrease at 80 kVp. There was a significant difference in the statistical values according to the tube voltage change in the lung, trachea, and heart SNR average values with AEC and without AEC 110 kVp, but the difference in image quality was insignificant in actual images. When AEC was not applied at the same tube voltage, the dose could be reduced by 17.2% while maintaining the image quality similar to that of with AEC at 100 kVp without AEC. Therefore, rather than relying on AE conditions during chest radiographic examination, it is considered that the conditions should be considered for the examination while lowering the dose by selecting an appropriate tube voltage.

Case Study on Physical Activity Guidance Experience to Maintain Balance in Adults with Cerebellar Ataxia (소뇌성 운동실조증 성인의 균형 유지를 위한 신체활동 지도 경험 사례 연구)

  • Jeonghyeon Kim
    • Journal of Industrial Convergence
    • /
    • v.22 no.3
    • /
    • pp.51-65
    • /
    • 2024
  • This study aims to understand positive changes in balance and gait function and difficulties in the instructor's guidance process through repetitive basic motor skill-based physical activities targeting people with cerebellar ataxia. For this purpose, five adults with cerebellar ataxia were selected as research subjects, and their three instructors participated as research participants. To collect quantitative data, the average and standard deviation were examined through pre-and post-evaluation of the research participants' physical activity classes for 16 weeks. The mean and standard deviation of the collected data were calculated using the Shapiro-Wilk test in the SAS 9.1 statistical program (p<.05). As a qualitative data collection method, the cultural description method of developmental research(DSR) proposed by Spradley(1980) was adopted, and the collected data were analyzed inductively according to the analysis method of Mertens(1990). Through this, 31 concepts, 10 subcategories, and 4 categories were discovered. As a result, the difficulties experienced by the research participants included insufficient guidance environment, dissatisfaction of consumers, difficulty in guidance, and non-cooperation of colleagues. Based on these research results, it was found that institutional, legal, and policy support should be provided not only to public institutions but also to private physical activity institutions that can use vouchers in order to maintain the balance of adults with cerebellar ataxia as well as to guide their physical activities.

The relationship of cognitive function and physical recovery stage on quality of life in stroke patients (뇌졸중 환자의 인지기능과 신체회복단계가 삶의 질에 미치는 영향)

  • Yeoil Jeon;Sangwoo Kim;Byoung-Hee Lee
    • Journal of Korean Physical Therapy Science
    • /
    • v.31 no.3
    • /
    • pp.51-65
    • /
    • 2024
  • Background: The patients common have side effects of cognitive and function dysfunction after a stroke. According to specific factors which influence quality of life(QoL), the QoL of stroke survivors are impacted resulting from diverse interactions. Therefore, This study aims to suggest that we determines the relationship between cognitive function and stage of physical recovery and the quality of life as well as the degree of recovery by cluster analysis of the relationship between the degree of physical recovery and the quality of life Design: Randomized Methods: The following tests were used in this study to evaluate cognitive function, recovery stages and quality of life respectively: Cognitive function was measured using Korea-Mini Mental State Examination(K-MMSE). For evaluation of recovery stages, Brunnstrom Rrecovery Stage(BRS), quality of life was measured using Stroke Specific -Quality Of Life(SS-QOL). The sample size of this study was calculated using G*Power Version 3.1.9.7 (Franz Faul, University kiel, Germany, 2020). Based on moderate effect size of 0.15, a significance level (α) of 0.05, and power of 0.90 in the two-sided test, the calculation revealed that 88 patients were required for questionnaires. Results: The results of this study showed significant positive correlation(p<0.05). As a result of cluster analysis, in the case of the physical recovery stage, the degree of physical recovery improves from cluster 1 to cluster 3 and in the case of the quality of life, the quality of life improves from cluster 1 to cluster 3. However, it was confirmed that the change in the quality of life of cluster 1 and cluster 2 was not significant. These results show that the degree of physical recovery has a greater impact on the quality of life in the late stages of physical recovery, while the degree of physical recovery does not have a significant effect on the quality of life in the early and mid-term of the physical recovery stage. Conclusion: This study confirms that cognitive function, recovery stages and quality of life have significant correlations, and the recovery status has impacted on quality of life.

The Comparison of Results Among Hepatitis B Test Reagents Using National Standard Substance (국가 표준물질을 이용한 B형 간염 검사 시약 간의 결과 비교)

  • Lee, Young-Ji;Sim, Seong-Jae;Back, Song-Ran;Seo, Mee-Hye;Yoo, Seon-Hee;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.203-207
    • /
    • 2010
  • Purpose: Hepatitis B is infection caused by Hepatitis B virus (HBV). Currently, there are several methods, Kits and equipments for conducting Hepatitis B test. Due to ununiformed methods, it would cause some differences. To manage these differences, it needs process evaluating function of test system and reagent using particular standard substance. The aim of this study is to investigate tendency of RIA method's reagent used in Asan Medical Center through comparing several other test reagents using national standard substance. Materials and Methods: The standard substance in National Institute of Food and Drug Safety Evaluation's biology medicine consists of 5 things, 4 antigens and 1 antibody. We tested reagents using A, B company's Kits according to each test method. All tests are measured repeatedly to obtain accurate results. Results: Test result of "HBs Ag Mixed titer Performance panel" is obtained match rate compared S/CO unit standard with RIA method and EIA 3 reagents, CIA 2 reagents is that company A's reagent is 94.4% (17/18), 83.3% (15/18), B is 88.9% (16/18), 77.8% (14/18). Test result of "HBs Ag Low titer Performance panel" is obtain that EIA 2 reagents is shown 7 posive results, CIA 3 reagents is 11, and RIA method's company A's reagent is 3, B is 2 of 13 in low panel. "HBV surface antigen 86.76 IU/vial" tested dilution. A is obtain positive results to 600 times(0.14 IU/mL), B is 300 times (0.29 IU/mL). Case of "HBV human immunoglobulin 95.45 IU/vial", A is shown positive result to 10,000 times (9.5 mIU/mL) and B is 4,000 times (24 mIU/mL). Test result of "HBs Ag Working Standards 0.02~11.52 IU/mL" is shown that Company A's kit concentration level was 0.38IU/mL, company B was 2.23 IU/mL and higher level of concentration was positive results. Conclusion: When comparing various test reagents and RIA method according to National Standard substances for Hepatitis B test, we recognized that there were no significant trends between reagents. For hepatitis B virus antigen-antibody titers even in parts of the test up to 600 times the antigen, antibodies to 10,000 times the maximum positive results could be obtained. Therefore, we confirmed that results from Asan Medical Center are performed smoothly by reagents and system for hepatitis B virus test.

  • PDF

Performance Evaluation of Artificial Lightweight Aggregate Mortar Manufactured with Waste Glass (폐유리로 제조된 인공경량골재를 이용한 모르타르의 물리적 성능에 대한 평가)

  • Kim, Seong-Soo;Lee, Jeong-Bae;Nam, Ba-Reum;Park, Kwang-Pil
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.2
    • /
    • pp.147-152
    • /
    • 2009
  • The compressive strength test, bulk density and mortar absorption ratio were carried out to utilize the data as the basic sources for the lightweight mortar and the lightweight concrete, through the study on the physical characteristics of the artificial lightweight aggregate (ALA) made of waste glasses, which was developed for the first time in the country. On the basis of these experiments, the density and the unit volume weight of the ALA showed the value less than 50% of the common aggregate due to the independent pore structure, and the mortar that contains ALA had no big difference from the Control mortar in the test of the absorption ratio. It is judged that this happens based on the internal independent pore structure of the ALA. In case of the mortar containing ALA, there was a tendency of declination in the compressive strength and the bending strength as the mixing rate is increasing, but all mortar showed more than 70% of the Control mortar compressive strength except for the La50 mortar. Hereafter, it is judged that according to the control of the mixing ratio of mineral admixing agent, water and cement, it will realize the equal strength to the control mortar, and the long term edurance is needed to be considered together.

Thick Film Resistors with Low Tolerance Using Photosensitive Polymer Resistor Paste (감광성 폴리머 저항 페이스트를 이용한 Low Tolerance 후막 저항체)

  • Kim, Dong-Kook;Park, Seong-Dae;Lee, Kyu-Bok;Kyoung, Jin-Bum
    • Applied Chemistry for Engineering
    • /
    • v.21 no.4
    • /
    • pp.411-416
    • /
    • 2010
  • In this research, we intended to improve the tolerance of thick film resistor using photosensitive polymer resistor paste which was fabricated with alkali-solution developable photosensitive resin and conductive carbon black. At first, we investigated the effect of the selection of carbon black and photosensitive resin on the resistance range and tolerance level of polymer thick film resistor (PTFR). And then, a difference in resistance tolerance was evaluated according to the coating methods of photosensitive resistor paste on test board. In case that the photosensitive resistor paste was coated on whole surface of test board using screen printing, large positional tolerance was obtained because the formation of the thick film with uniform thickness was difficult. On the other hand, when the paste was coated with roller, the resistive thick film with uniform thickness was formed on the whole board area and the result of resistance evaluation showed low tolerance in ${\pm}10%$ range. The tolerance of PTFR could be improved by combination of the precise patterning using photo-process and the coating process for the resistive thick film with uniform thickness.

Evaluation of Honeybee Acute Toxicity of Plant Extracts, Neem, Sophora and Derris (식물추출 유기농업자재 3종(님, 고삼, 데리스 추출물)의 꿀벌에 대한 독성평가)

  • Oh, Jin-A;Choi, Jin-Hee;Choe, Mi-Seon;Kim, Jin-Hyo;Paik, Min-Kyoung;Park, Kyung-Hun;Hong, Soon-Sung;Lee, Je-Bong;Kim, Doo-Ho
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.4
    • /
    • pp.473-477
    • /
    • 2013
  • This study was performed to evaluate the acute contact and oral toxicity of plant extracts (neem, sophora and derris) against Honeybee (Apis mellifera L.). As a result of acute contact toxicity test, $LD_{50}$ of neem and derris extracts were more than 100 ${\mu}g/bee$ while $LD_{50}$ of sophora extracts were 1.7 ${\mu}g/bee$. In case of acute oral toxicity test, $LD_{50}$ of neem and derris extracts were more than 100 ${\mu}g/bee$ while $LD_{50}$ of sophora extracts were 1.7 and 0.3 ${\mu}g/bee$. In conclusion, it is evaluated that neem and derris extracts are practically nontoxic while sophora extracts are highly toxic.

Evaluation of Reliability of Strain Gauge Measurements for Geosynthetics (토목섬유 보강재에 적용한 스트레인게이지 실측값의 신뢰성 평가)

  • Cho, Sam-Deok;Lee, Kwang-Wu;Li, Zhuang;Kim, Uk-Gie
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.4
    • /
    • pp.87-96
    • /
    • 2015
  • Geosynthetics are widely used in different ways such as reinforcement of structures in road, railway, harbor and dam engineering, drainage, separation and erosion prevention. They are especially applied to reinforced retaining wall and slope or ground reinforcement. Recently, geosynthetics reinforced pile supported (GRPS) embankment was developed to improve stability and construability of embankments in railway engineering. Extension strains are usually measured by strain gauges adhered to geosynthetics to evaluate the stability of geosynthetics. However, the measurements are influenced by manufacturing method and stiffness of geosynthetics and also adherence of strain gauge. In this study, wide-width tensile strength tests were performed on three types of geosynthetics including geogrid, woven geotextile and non-woven geotextile. During the test, strains of geosynthetics were measured by both video extensometer and strain gauges adhered to the geosynthetics and the measured results were compared. Results show that the measured results by strain gauges have high reliability in case of large stiffness geosythetics like geogrid and woven geotextile, whereas they have very low reliability for small stiffness geosythetics like non-woven geotextile.

Nondestructive Interfacial Evaluation and fiber fracture Source Location of Single-Fiber/Epoxy Composite using Micromechanical Technique and Acoustic Emission (음향방출과 미세역학적시험법을 이용한 단일섬유강화 에폭시 복합재료의 비파지적 섬유파단 위치표정 및 계면물성 평가)

  • Park, Joung-Man;Kong, Jin-Woo;Kim, Dae-Sik;Yoon, Dong-Jin
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.5
    • /
    • pp.418-428
    • /
    • 2003
  • Fiber fracture is one of the dominant failure phenomena affecting the total mechanical Performance of the composites. Fiber fracture locations were measured through the conventional optical microscope and the nondestructive acoustic emission (AE) technique and then were compared together as a function of the epoxy matrix modulus and the fiber surface treatment by the electrodeposition method (ED). Interfacial shear strength (IFSS) was measured using tensile fragmentation test in combination of AE method. ED treatment of the fiber surface enlarged the number of fiber fracture locations in comparison to the untreated case. The number of fiber fracture events measured by the AE method was less than optically obtained one. However, fiber fracture locations determined by AE detection corresponded with those by optical observation with small errors. The source location of fiber breaks by AE analysis could be a nondestructive, valuable method to measure interfacial shear strength (IFSS) of matrix in non-, semi- and/or transparent polymer composites.