A Study on the Performance Analysis of an Extended Scan Path Architecture (확장된 스캔 경로 구조의 성능 평가에 관한 연구)

  • 손우정
    • Journal of the Korea Society of Computer and Information
    • /
    • v.3 no.2
    • /
    • pp.105-112
    • /
    • 1998
  • In this paper, we propose a ESP(Extended Scan Path) architecture for multi-board testing. The conventional architectures for board testing are single scan path and multi-scan path. In the single scan path architecture, the scan path for test data is just one chain. If the scan path is faulty due to short or open, the test data is not valid. In the multi-scan path architecture, there are additional signals in multi-board testing. So conventional architectures are not adopted to multi-board testing. In the case of the ESP architecture, even though scan path is either short or open, it doesn't affect remaining other scan paths. As a result of executing parallel BIST and IEEE 1149.1 boundary scan test by using the proposed ESP architecture, we observed that the test time is short compared with the single scan path architecture. By comparing the ESP architecture with single scan path responding to independency of scan path, test time and with multi-scan path responding to signal, synchronization, we showed that the architecture has improved results.

  • PDF

Difference of Potential Range Formed at the Anode Between Water Drop Test and Temperature Humidity Bias Test to Evaluate Electrochemical Migration of Solders for Printed Circuit Board

  • Young Ran Yoo;Young Sik Kim
    • Corrosion Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.153-163
    • /
    • 2023
  • Two types of accelerated tests, Water Drop Test (WDT) and Temperature-Humidity-Bias Test (THBT), can be used to evaluate the susceptibility to electrochemical migration (ECM). In the WDT, liquid water is directly applied to a specimen, typically a patterned conductor like a printed circuit board. Time to failure in the WDT typically ranges from several seconds to several minutes. On the other hand, the THBT is conducted under elevated temperature and humidity conditions, allowing for assessment of design and life cycle factors on ECM. THBT is widely recognized as a more suitable method for reliability testing than WDT. In both test methods, localized corrosion can be observed on the anode. Composition of dendrites formed during the WDT is similar to that formed during THBT. However, there is a lack of correlation between the time to failure obtained from WDT and that obtained from THBT. In this study, we investigated the relationship between electrochemical parameters and time to failure obtained from both WDT and THBT. Differences in time to failure can be attributed to actual anode potential obtained in the two tests.

Anxiolytic Effects of Quercetin: Involvement of GABAergic System (Quercetin의 항불안 효과: GABA 신경계를 중심으로)

  • Jung, Ji Wook;Lee, Seungheon
    • Journal of Life Science
    • /
    • v.24 no.3
    • /
    • pp.290-296
    • /
    • 2014
  • The present experiment investigated putative anxiolytic-like effects of quercetin using an elevated plus-maze (EPM) and hole-board apparatus test in mice. Quercetin is a flavonoid widely distributed in nature. Quercetin (1.25, 2.5, 5, or 10 mg/kg) was orally administered to ICR mice 1 h before a behavioral evaluation in the EPM. Control mice were treated with an equal volume of vehicle, and positive control mice were treated with buspirone (2 mg/kg, i.p.). The mice administered quercetin (5 mg/kg) spent a significantly longer percentage of time in the open arms of the EPM and their percentage of entries into the open arms was significantly increased compared to the vehicle-treated controls (p<0.05). The anxiolytic-like activities of quercetin were antagonized by trans-4-aminocrotonic acid (a $GABA_{A-{\rho}}$ agonist, 20 mg/kg) but not by flumazenil (a $GABA_A$ antagonist, 10 mg/kg) or WAY-100635 (a $5-HT_{1A}$ antagonist, 0.3 mg/kg). Moreover, there were no changes in the locomotor activity or myorelaxant effects in any group compared with the vehicle-treated controls. In the hole-board apparatus test, the number of head-dips increased significantly in the single treatment with quercetin (5 mg/kg) group compared to the vehicle-treated controls (p<0.05). These findings suggest that quercetin can promote anxiolytic-like activity, mediated by the GABAergic nervous system, in mice.

A Study on the Interconnection Technology between Tablet Device and Interactive White Board System (태블릿 기기와 전자칠판 시스템 간의 연동 기술 연구)

  • Choi, Yun-Su;Hwang, Min-Tae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.7
    • /
    • pp.1719-1727
    • /
    • 2015
  • In this paper we have studied about the interconnection technology between tablet device and interactive white board(IWB) system. For this study we have implemented the board writing software for both tablet device and interactive white board system which has contents management, page turning and basic writing functions. Then we defined the data format to communicate the control information and board writing information between two devices, and implemented the communication module for the real-time bidirectional communication by using the Socket programming. The page turning or writing information on tablet device were transferred to the IWB system in real-time and vice versa. From the result of performance test based on the error rate, latency time and communication coverage we derived that our implementation software has good performance between tablet device and IWB system. Also from the result of field test we proved that our solution is well suitable to use in real education environment.

Test-retest Reliability of Sit-to-Stand and Gait Assessment Using the Wii Balance Board (Wii Balance Board를 이용한 Sit-to-Stand와 보행기능 측정의 검사-재검사 신뢰도)

  • Yang, Seong-rye;Oh, Yu-ri;Jeon, Ye-rim;Park, Dae-sung
    • Physical Therapy Korea
    • /
    • v.23 no.3
    • /
    • pp.40-47
    • /
    • 2016
  • Background: Assessments of Sit-to-Stand (STS) and gait functions are essential procedures in evaluating level of independence for the patients after stroke. In a previous study, we developed the software to analyze center of pressure (COP) in standing position on Wii Balance Board (WBB). Objects: This purpose of this study is to measure test-retest reliability of ground reaction forces, COP and time using WBB on STS and gait in healthy adults. Methods: Fifteen healthy participants performed three trials of STS and gait on WBB. The time (s), vertical peak (%) and COP path-length (cm) were measured on both tasks. Additionally, counter (%), different peak (%), symmetry ratio, COP x-range and COP y-range were analyzed on STS, 1st peak (%), 2nd peak (%) of weight were analyzed on gait. Intra-class correlation coefficient (ICC), standard error measurement (SEM) and smallest real difference (SRD) were analyzed for test-retest reliability. Results: ICC of all variables except COP path-length appeared to .676~.946 on STS, and to .723~.901 on gait. SEM and SRD of all variables excepting COP path-length appeared .227~8.886, .033~24.575 on STS. SEM and SRD excepting COP path-length appeared about .019~3.933, .054~11.879 on gait. Conclusion: WBB is not only cheaper than force plate, but also easier to use clinically. WBB is considered as an adequate equipment for measuring changes of weight bearing during balance, STS and gait test which are normally used for functional assessment in patients with neurological problems and elderly. The further study is needed concurrent validity on neurological patients, elderly patients using force plate and WBB.

On Board Computer Design, Analysis and Test for KOMPSAT2 (KOMPSAT2 탑재컴퓨터 설계, 성능 분석 및 시험)

  • 조영호;심재선
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.8
    • /
    • pp.571-577
    • /
    • 2004
  • In this paper, we describe the structure, function and the design factor of common module for KOMPSAT-2 OBC, which will be launched in 2005. By analysing OBC's performance, we can know the throughput and how much improve performance than KOMPSAT-l. it is used in the satellite mission design by system engineer. We verify the usefulness of common module for KOMPSAT-2 OBC through environment test.

Test Technology of Digital Circuit Board Based on Serial Signature Analysis Technique in Production Line (생산라인에서 SSA 기법에 근거한 디지털 회로 보오드 검사 기술)

  • Ko, Yun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2193-2195
    • /
    • 2001
  • This paper proposes test strategy detecting the faulted digital device or the faulted digital circuit on the digital circuit board using signature analysis technique based on the polynoimal division theory. SSA(serial Signature Analysis) identifies the faults by comparing the reminder from good device and reminder from the tested device, which reminder is obtained by enforcing the data stream outputed from output pins of tested device on LFSR(Linear Feedback Shift Resister) representing the characteristic equation.

  • PDF

The analysis on the NDF(No Defect Found) of Note PC main board using HALT (HALT 기술을 이용한 Note PC main board의 NDF성 고장 검토 사례)

  • 강상구;김재이
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2001.06a
    • /
    • pp.397-403
    • /
    • 2001
  • 본 논문은 시장 사용 조건에서 발생한 PC제품의 Main board 고장품이 회수 후 검토 시 정상적으로 기능하여 나타나는 NDF(No Defect Found) 판정 상황에 대한 효과적인 검토 방안을 제시한다. NDF 시료의 고장성 진위 여부를 가리기 위해 HALT(Highly Accelerated Life Test)기술을 응용한 결과 기존의 시험 검토 방법보다 높은 재현 효과를 보았다. 결함 제품의 잠재적인 취약부위를 단시간에 효과적으로 촉진하고 들춰내는 HALT 기술은 전자 제품의 NDF성 고장을 기술적으로 접근하여 개선할 수 있는 기초를 제공하는 유용한 가속 스트레스 시험 기술임이 입증되었다.

  • PDF

Thermal Performance of a Heating Board with a Microencapsulated Myristic Acid (Myristic acid를 사용한 축열장판의 열성능 연구)

  • Kwak, H.Y.;Kang, Y.H.;Jeon, M.S.;Lee, T.K.;Lee, D.G.;Han, G.Y.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.177-183
    • /
    • 1998
  • The thermal performance of a heating board with microencapsualted PCM was investigated and compared to conventional heating board. The employed PCM was the myristic acid $$ and was encapsulated by the multiple layers of PMMA and paraffin wax. The size of encapsulated PCM was $1{\sim}1.5mm$. Accoring to ANSI/ASHRAE test procedure, the close-loop test configuration was installed. Air was used as the heat transfer fluid and a calibrated orifice was employed for the measurement of air flow rates. The thermal performance test of two different heating boards(with 10 wt% PCM and without PCM) was conducted for different air flow rates and the heat transfer characteristics during cooling was compared. The test results showed that the surface temperature of heating board with 10 wt% PCM maintained higher during the cooling process than that of the heating board without PCM and experimentally determined heat transfer coefficient in heating board with PCM showed higher value compared to heating board without PCM.

  • PDF