• 제목/요약/키워드: Test 1

검색결과 60,115건 처리시간 0.077초

이하선 절제술 후 요오드-녹말 검사를 이용한 Frey 증후군의 발생 빈도 및 임상 양상 (Incidence and Characteristics of Frey's Syndrome after Parotidectomy by Minor's Starch-Iodine Test)

  • 강태욱;송창면;김홍대;고석화;장연일;지용배;태경
    • 대한두경부종양학회지
    • /
    • 제32권1호
    • /
    • pp.1-5
    • /
    • 2016
  • Objectives: Frey's syndrome is an infrequent complication after parotidectomy and its incidence varies from 23.5% to 50.8% in the literature. The objective of this study was to evaluate the actual incidence and clinical characteristics of Frey's syndrome. Methods: We analyzed 31 patients who underwent parotidectomy and serial Minor's starch-iodine test. The mean follow-up period was $66{\pm}26.1$ months (range, 24-118 months). The Frey's syndrome was analyzed using a questionnaire for the assessment of the subjective symptom and Minor's starch-iodine test for the objective measurement at 1, 3, 6, and 12 months after the surgery and then every 6 or 12 months. Minor's starch-iodine test was graded from 0 to 3 according to the area of discolorization. Results: Frey's syndrome occurred in 11 patients (35.5%) on the Minor's starch-iodine test. The mean onset of Frey's syndrome on the starch-iodine test was $13.6{\pm}10.4$ months after parotidectomy. Sixteen patients (51.6%) complained about gustatory sweating and flushing. The onset of the subjective symptom was $11.27{\pm}6.96$ months after the surgery. There was a significant correlation between the grade of the starch-iodine test and the severity of subjective symptoms (P <0.001). Various factors including size and location of tumor, incision method, and extent of parotidectomy did not correlate with the Frey's syndrome. Conclusion: The incidence of Frey's syndrome was 35.5% on the Starch-Iodine test, and the onset was about postoperative 13.6 months.

기울기를 이용한 랜덤워크 윌콕슨 부호순위검정 (A Wilcoxon signed-rank test for random walk hypothesis based on slopes)

  • 김태윤;박철용;김슬기;김민석;이우정;권윤지
    • Journal of the Korean Data and Information Science Society
    • /
    • 제25권6호
    • /
    • pp.1499-1506
    • /
    • 2014
  • 랜덤워크는 다양한 분야에서 랜덤현상을 기술하는데 이용되고 있으나, 현재까지 개발된 랜덤워크 검정법에는 유의수준 왜곡과 낮은 검정력 등의 문제가 있는 것으로 알려져 있다. 이러한 문제점들을 개선하기 위해 Kim 등 (2014)은 부호검정에 기초한 랜덤워크 검정 (${\rho}=1$)방법을 제안하였다. 본 논문에서는 보다 개선된 랜덤워크 검정법을 제안하고자 부호검정보다 검정력이 우수한 것으로 알려진 윌콕슨 부호순위검정을 이용한 랜덤워크 검정법을 제안하고, 모의실험을 통해 부호검정, 윌콕슨 부호순위검정, 확장 Dickey-Fuller 검정의 성능을 비교하였다. 모의실험 결과 소표본에서 비모수 검정기법들이 ADF 검정보다 우월하다는 사실을 재확인하였다. 새롭게 밝혀진 사실은 부호검정이 윌콕슨 부호순위검정에 비해 높은 검정력을 가지며, 또한 비모수 검정기법들은 ${\rho}$가 양의 부호를 가지는 경우 (0 < ${\rho}$ < 1) 정규분포보다 이중지수분포에서 낮은 검정력을 가지게 되나, ${\rho}$가 음의 부호(-1 < ${\rho}$ < 0)를 갖는 경우에는 정규분포보다 이중지수분포에서 높은 검정력을 보인다는 사실이다.

검사건수에 따른 임상병리사의 인원편성에 관한 설문조사 분석 (Survey on the Relationship between the Number of Medical Technologists and the Medical Test Count)

  • 김정현;김대은;윤중수;이정수;박태화
    • 대한임상검사과학회지
    • /
    • 제51권1호
    • /
    • pp.93-104
    • /
    • 2019
  • 본 연구는 국내의 진단검사의학과의 검사현황 및 인력배치현황과 검사 건수를 파악하기 위함이다. 지역별, 규모별 임상병리사를 대상으로 설문조사를 실시하여 최종 441부를 분석 자료로 사용하였다. 자료의 분석은 STATA (version 12.0)를 이용하여 Descriptive statistics analysis, Chi-square test, ANOVA test를 실시하였다. 병원 규모별 임상병리사 분포는 의원급 5.8명, 병원급 14.9명, 종합병원 25.8명, 대학병원 45.4명으로 나타났다. 부서별검사건수, 1인 1일 검사건수는 의원, 병원, 종합병원, 대학병원간의 유의한 차이가 있었다. 임상병리사의 1일 검사건수와 1일 적정 검사건수의 차이는 상급병원으로 갈수록 감소하는 것으로 나타났다. 정도관리는 상급병원의 부서별 정도관리 평균 시간은 2시간 이내로 나타났다. 급여만족도, 근무환경만족도, 검사성취도, 복지제도측면에서 의원, 병원급에서 불만족도 다수 차지하는 것으로 나타났다. 이는 선진국형 의료 수준에 맞는 신뢰성 있는 검사의 데이터를 제공하기 위해 임상 병리사의 근무환경에 따른 근무의 만족도와 임상검사의 정확도를 높이기 위해서라도 임상병리사의 처우개선에 초점을 맞추어야 할 것으로 사료된다.

회전근 개 파열의 진단을 위한 극상근 검사에서 유용한 양성 징후는 무엇인가? - "Empty can test"와 full can test"에서 통증과 근력 약화의 비교 - (What are Valuable Positive Signs of Supraspinatus Test for Diagnosis of Torn Rotator Cuff? - Comparison of Pain and Weakness in "Empty Can Test" and "Full Can Test" -)

  • 신헌규;김유진;정화재;김종민;최재열;이용택
    • Clinics in Shoulder and Elbow
    • /
    • 제10권1호
    • /
    • pp.27-32
    • /
    • 2007
  • 목적: 회전근개 파열에서 극상근 검사의 진단적 가치와 유용한 검사 양성이 무엇인지를 밝히고자 하였다. 대상 및 방법: 견관절 통증 환자 200명을 대상으로 empty can test와 full can test를 시행하여 수술 또는 자기공명영상의 소견으로 분석하였다. 통증과 근력 약화를 나누어 기록하였으며, 파열의 정도에 따른 통증과 근력약화의 분포, 각 검사법의 예측율 및 기존의 양성이라고 정의 되었던 통증 또는 근력약화가 있는 경우와 다른 양성 징후 들과의 조합에 대한 일치도를 조사하였다. 결과: 통증과 근력약화는 회전근개 파열의 정도에 따라 비례하였고 empty can test에서 통증의 빈도가 높았다. 부분파열을 파열로 간주한 경우 두 검사 모두 민감도가 높았으나 특이도는 전층 열만을 파열로 간주한 경우가 높았다. 부분파열을 파열로 간주한 경우와 그렇지 않은 경우, 또한 Empty 및 Full can test 모두에서 통증과의 일치도가 가장 높았다. 결론: empty can test가 통증의 빈도가 높았으며, 두 가지 극상근 검사 모두 전층파열과 부분파열에 민감하고 전층파열에 특이하였다. 극상근 검사는 통증과 근력 약화를 분리하여 양성을 기록한다면 회전근 개 파열의 진단을 위한 이학적 검사로서 가치가 높다고 판단되었다.

요로감염소아의 오줌에서 분리한 대장균 K1 다당류 항원의 동정 (Identification of K1 Polysaccharide Antigen of Escherichia coli Isolates from Urine Specimens of Urinary Tract Infections in Children)

  • 정희곤
    • 한국식품영양학회지
    • /
    • 제11권4호
    • /
    • pp.416-419
    • /
    • 1998
  • Identification of escherchia coli K1 polysaccharide antigen isolated from urine specimens of urinary tract infections in children were performed from of 1992 to 1993 in Kyoto, Japan. The serotypes of E. coli were categorized that O1:H7, O2:H6, O2:H7, O16:H6, O18:H7, O18:H ̄, and O135:H44 among 14 strains isolated from urine specimens of urinary tract infections in children by the serological test. And, one strain (O18:H ̄, isolation rate: 7.1%) of E. coli K1 polysaccharide antigen among 14 strains were isolated from urine specimens of urinary tract infections in children by the bacteriophage test.

  • PDF

Evaluation of Fracture Strength and Material Degradation for Weldment of High Temperature Service Steel Using Advanced Small Punch Test

  • Lee, Dong-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • 제18권9호
    • /
    • pp.1604-1613
    • /
    • 2004
  • This paper presents an effective and reliable evaluation method for fracture strength and material degradation of the micro-structure of high temperature service steel weldment using advanced small punch (ASP) test developed from conventional small punch (CSP) test. For the purpose of the ASP test, a lower die with a minimized ${\Phi}$1.5 mm diameter loading ball and an optimized deformation guide hole of ${\Phi}$3 mm diameter were designed. The behaviors of fracture energy (E$\_$sp/), ductile-brittle transition temperature (DBTT) and material degradation from the ASP test showed a definite dependency on the micro-structure of weldment. Results obtained from ASP test were compared and reviewed with results from CSP test, Charpy impact test, and hardness test. The utility and reliability of the proposed ASP test were verified by investigating fracture strength, behavior of DBTT, and fracture location of each micro-structure of steel weldment for test specimen in ASP test. It was observed that the fracture toughness in the micro-structure of FL+CGHAZ and ICHAZ decreased remarkably with increasing aging time. From studies of all micro-structures, it was observed that FGHAZ microstructure has the most excellent fracture toughness, and it showed absence of material degradation.

경추회전제한검사법에 대한 소고; 근육검사법 관점에서 (A Study of Restricted Cervical Rotation Test; in the View of Manual Muscle Test)

  • 안성훈;이영준;손인철
    • 턱관절균형의학회지
    • /
    • 제2권1호
    • /
    • pp.8-12
    • /
    • 2012
  • Objectives: It has been reported to continue that temporomandibular joint balancing medicine (functional cerebrospinal therapy; FCST) is effective in treating incurable diseases in clinic recently. FCST is based on the results of restricted cervical rotation test, it means that the results of restricted cervical rotation test has a very high reliability on test results. Methods: This study has the aim to understand restricted cervical rotation test method and to use well with high technical skill. So manual muscle test method which was based on the upper limb lifting resistance test method are compared with restricted cervical rotation test method and had been discussed. Results: Results are that restricted cervical rotation test by using the passive motion of arrested persons (patients) have high the reliability and accuracy. Conclusions: It is concluded that restricted cervical rotation test is the new type of manual muscle tests and the results of test are very high the reliability and accuracy so that the acquirement of test method is helpful in clinic practically.

  • PDF

런 검정을 사용한 근전도 신호의 안정성 평가 시 분할 크기가 신호의 안정성에 미치는 영향 (Effects of Segmentation Size on the Stationarity of Electromyographic Signal in Runs Test)

  • 조영진;김정룡
    • 대한인간공학회지
    • /
    • 제29권4호
    • /
    • pp.667-671
    • /
    • 2010
  • Runs test is a mathematical tool to test the stationarity of electromyographic (EMG) signals. The purpose of this study is to investigate the effects of segmentation size on the stationarity of EMG signals in runs test. Six subjects participated in this experiment and performed isometric trunk exertions for twenty seconds at the load level of 25% and 50% MVC. The signals extracted from the erector spinae muscles were divided into the intervals of 1000ms and the stationarity of the signal in each interval was tested by the runs test. In this test, seven segmentation sizes such as 1.0, 2.0, 3.9, 7.8, 15.6, 31.3 and 62.5ms were applied. Additionally, two stationarity tests of reverse arrangements test and modified reverse arrangements test were used to verify the results of the runs test. In results, the segmentation size of 62.5ms showed the similar results with the other stationarity tests. However, the stationarity values among there tests were different each other when segmentation sizes other than 62.5ms were used. These results indicated the effect of segmentation size in runs test that needs to be considered to have consistent and sensitive result in stationarity test.

표준관입시험을 이용한 업홀시험에서 전단파 속도 주상도의 도출 (Evaluation of Shear Wave Velocity Profiles by Performing Uphole Test Using SPT)

  • 김동수;방은석;서원석
    • 한국지반공학회논문집
    • /
    • 제19권2호
    • /
    • pp.135-146
    • /
    • 2003
  • 본 논문에서는 지반의 전단파 속도 주상도를 획득하기 위한 현장 시험법으로 표준관입시험 샘플러를 가진원으로 이용한 업홀 시험기법을 연구하였다. 제안된 업홀 시험은 지표면에 여러 개의 속도계를 시추 장비로부터 일정한 간격으로 한 줄로 배치를 하고 표준관입시험의 시료 채취기로부터 발생되는 진동원의 신호를 계측하여 지반의 전단파속도 주상도를 도출하는 방법이다. 여러 선행 실험을 통하여 확립된 업홀 시험 방법 및 결과 분석법에 대해 소개하였다. 진동원과 감지기간의 거리가 멀기 때문에 지반에서 진행되는 전단파의 진행 경로는 지반의 강성 변화에 근거한 굴절 경로를 적용하였다. 국내 3개 시힘 부지에서 수행한 업홀 시힘결과를 동일 부지에서 행한 다운홀, SASW시험 및 SPT-N치와 비교하여 봄으로써 제안된 업홀 시험의 현장 적용성을 확인하였다.

이중 전동식 진동 시험기를 이용한 무인 비행체의 비행진동 환경시험 연구 (A Study On Flight Vibration Environmental Test of Unmanned Aerial Vehicle using Dual Electric Vibration Exciters)

  • 최장섭;오동호
    • 한국군사과학기술학회지
    • /
    • 제26권3호
    • /
    • pp.252-261
    • /
    • 2023
  • Analysis of dynamic characteristics and flight vibration test for unmanned aerial vehicles was studied by using dummy test body. The FEM model for dummy test body was supplemented by results of modal and random vibration test. The free end boundary condition to simulate flight environments was made by test setup using bungee cable. Prior to the flight vibration test using a dual electric vibration exciters, the test procedure to calculate quantitative vibration level was studied by using military specification. The actual test was successfully done by using the analysis and pretest results. From the analysis results, it was possible to determine the feasibility of the test by predicting the excitation force of the flight vibration test and to get the response of any point which could not be measured by the test. The results of this study will much contribute to the Test and Evaluation of unmanned aerial vehicles.