• 제목/요약/키워드: Test 1

검색결과 59,985건 처리시간 0.063초

경중량 수직형 충격 시험 장비의 선형 동역학 모델 수립을 통한 충격 시험 설계 기법에 관한 연구 (A Study on Shock Test Design Method Using Linear Dynamic Model of Light Weight Vertical Shock Test Machine)

  • 김준혁;오부진;임담혁
    • 한국군사과학기술학회지
    • /
    • 제24권1호
    • /
    • pp.70-78
    • /
    • 2021
  • Naval surface ships and submarines could be exposed to non-contact underwater explosion(UNDEX) environment. Equipment installed on the ships and submarines could be damaged by shock load generated by UNDEX environment. Therefore, shock survivability of equipment generally evaluated by shock tests. Ground based shock test machine such as Light weight shock test machine(LVSM) is developed to simulate shock load caused by UNDEX environment. In this study, linear dynamic model of LVSM is proposed and evaluated to improve shock test design procedure. Parameters of the model are decided by optimizing time domain response compared to zero payload experiment. Proposed model is verified by comparing simulation results and test results of maximum payload experiment. Finally, shock test design using the model is described for various test equipment weight.

Latex 응집반응을 이용한 동물의 톡소플라즈마병 진단용 kit 개발에 관한 연구 (Development of diagnostic kit(Test-MT) for the microplate latex agglutination test of toxoplasmosis in animal)

  • 서명득;주후돈;데이빗 마-스
    • 대한수의학회지
    • /
    • 제35권3호
    • /
    • pp.583-593
    • /
    • 1995
  • The present study was conducted to develop a toxoplasma latex agglutination test antigen(Test-MT) and evaluate the toxoplasma latex agglutination(LA) test using a newly-made "Test-MT kit" by comparing with the Toxo-MT kit(Eiken chemical co, Tokyo). Also, the specifity and sensitivity test were made by comparing with IFA test and IgG-ELISA. Tachyzoite suspensions of Toxoplasma gondii(RH strain) were ultracentrifuged for 30min at $60,000{\times}g(4^{\circ}C)$ and the supernatant was used as a water-lysate antigen. Polystyrene latex particles of $1.0{\mu}m$ in diameter(Polyscience co) were used for the preparation of sensitized latex-antigen supension(Test-MT). The frequency distribution of LA titers in Test-MT showed two peaks at <1:32 and 1:128. The borderline titer for positive test in Test-MT was determined to be 1:64. But the frequency distribution of LA tites in Toxo-MT showed two peaks at <1:16 and 1:64. The positive borderline was determined to be 1:32. Agreement of reactions between Test-MT and Toxo-MT kit by LA test was shown 92.5% in bovine sera and 97.0% in swine sera, respectively. From the results obtained here it was determined that the sensitized latex-antigen, Test-MT kit, for the microtiter agglutination test prepared as same as by the procedure described in the previous paper(Suh and Lee, 1993) was useful as a highly specific, sensitive and stable immunotiteration reagent for serodiagnosis of toxoplasma infection in animal sera.

  • PDF

국내외 보급형 소방용 보호장갑의 동작성 평가 -착탈 시험, 기민성 시험, 회전력 시험을 중심으로- (Mobility Evaluation of Popular Firefighting Protective Gloves in Domestic and Foreign Countries -Don-Doff Test, Dexterity Test, and Torque Test-)

  • 김다미;이인성;이주영
    • 한국의류학회지
    • /
    • 제40권5호
    • /
    • pp.921-935
    • /
    • 2016
  • This research analyzed the manual performance of firefighting protective gloves on global markets in order to suggest an evaluation method for firefighting protective gloves wearing comfort. We collected 13 types of firefighting gloves from domestic and international markets (7 types from Korea, 3 types form Europe, 2 types from the U.S and 1 type from Japan). We set the Don-Doff test as a basal requirement for moving toward to further manual performance tests that consist of: ASTM dexterity test, Minnesota dexterity test, Bennett hand tool test and ASTM torque test. All gloves were evaluated in dry and wet conditions, we included eight current male firefighters ($43.4{\pm}7.0yr$ in age, $173.1{\pm}4.4cm$ in height, $79.9{\pm}9.2kg$ in body mass) for the tests. Four gloves (1 Korea, 1 U.S, 1 Germany, and 1 Japan) out of thirteen firefighting gloves passed the Don-Doff test and had great subject preferences. There was no significant difference between dry and wet conditions on the ASTM dexterity test, Minnesota dexterity test, Bennett hand tool test and ASTM torque test. However, Japanese gloves had the greatest score and showed 3-4 times faster completion time on the ASTM dexterity test (p<.05), 1.2-1.5 times faster on the Minnesota dexterity test (p<.05), as fast as the bare hand on Bennett hand tool test (p<.05), and greater performance on the ASTM torque test compared to bare hand. In conclusion, Don-Doff test in wet conditions should be the first step for a mobility evaluation of domestic firefighting protective gloves; subsequently, a comprehensive test assorting ASTM, Minnesota, and Bennett test should be developed as a second step. The current ASTM torque test can be adopted as a third step. This three-step-method for evaluating firefighting protective glove mobility can be expected to expand into surveys of other safety gloves in Korea.

재봉사의 가봉성 평가 -재봉사의 사절을 중심으로- (The Evaluation of Sewability for Sewing Threads -In Relation to the Breakage of Sewing Threads During Sewing Operation-)

  • 장정대
    • 한국의류산업학회지
    • /
    • 제1권2호
    • /
    • pp.154-159
    • /
    • 1999
  • In this study, for different test methods of the performance of sewing threads were used to evaluate the sewability of 10 different industrial threads. Sewability evaluations related to the breakage of thread during sewing operation were investigated by seam length and fabric thickness method (Test 1), thread tension method (Test 2), strength retention method (Test 3), and backward sewing method(Test 4), and discussed. Two of the methods, Test 1 and Test 2, simulated very harsh sewing conditions which each thread could accept as an evaluation of its sewability. Core spun thread ranked with the best sewability generally and followed by air jet textured (ATY) thread. Spun thread was superior to the filament thread in sewing thread type. In general, there was a high degree of correlation in the results of Test 1 and Test 2. The order of sewing thread by sewability test 1 was polyester spun thread, cotton thread, and p/c core spun thread. The order of sewing thread by test 2 was polyester spun thread, and p/c core spun thread. Cotton threads and cotton blended threads performed better in Test 3, and ATY threads and core spun threads in Test 4.

  • PDF

Latex 응집반응과 간접형광항체법을 이용한 개 톡소플라즈마병의 혈청학적 진단 (Serodiagnosis of canine toxoplasmosis by latex agglutination and indirect fluorescent antibody test)

  • 이병훈;이응구;서명득
    • 대한수의학회지
    • /
    • 제32권4호
    • /
    • pp.641-647
    • /
    • 1992
  • This study was conducted to determine the serum antibodies against toxoplasma in the artificially infected dogs, pet and street dogs by latex agglutination (LA) and indirect fluorescent antibody (IFA) test. LA test was carried out with commercial Toxo-MT kit (Eiken chemical Co.) and IFA test was carried out with rabbit-anti-dog IgG labelled with FITC (Cappel Co.) and toxo-antigen slides prepared in laboratory. The results obtained were as follows ; 1. Antibodies to Toxoplasma gondii in the artificially infected dogs were detected firstly at the Day 8 in IFA and Day 9 in LA test after inoculation. Positive antibody reactions by these tests were declined gradually afterward but maintained up to 12 weeks. 2. In LA test serum antibody titers in 310 test sera were shown as 10 cases(32%) in 1 : 32.5(1.0%) in 1 : 64, 4(1.3%) in 1 : 128 and 2(0.7%) in 1 : 256. In IFA test serum antibody titers 310 test sera were shown as 17 cases(5.5%) in 1 : 64, 8(2.6%) in 1 : 128 and 5(1.6%) in 1 : 256. 3. In the total of 310 sera from pet and street dogs toxoplasma antibody positive rates were 21 cases (6.8%) by LA and 30 cases (9.7%) by IFA test and the positive detection rates between these two groups by LA and IFA test were not significant(p<0.05). 4. In the total of 115 sera from pet dogs toxoplasma antibody positive rates were 12 cases(10.4%) by LA and 15(13.0%) by IFA test. And in the 195 street dogs the positive rates were 9 cases(4.6%) by LA and 15(7.7%) by IFA test. Also, the positive detection rates between these two groups by LA and IFA test were not significant(p<0.05). 5. Agreement of reactivity between LA and IFA test for 310 sera was 91.3% in total of 283 cases consisting of 12 cases(3.9%) of both LA and IFA positive and 271 cases(87.4%) of LA and IFA negative. 6. LA test was almostly equivalent to the IFA test in producibility and proved to be a simple tool for the screening of toxoplasma antibody in laboratory.

  • PDF

제 3대구치와 인접한 제 2대구치의 치주상태에 대한 고찰 (A study on the periodontal status of second molar adjacent third molar)

  • 이해두;홍기석;정진형;임성빈
    • Journal of Periodontal and Implant Science
    • /
    • 제36권2호
    • /
    • pp.489-502
    • /
    • 2006
  • The purpose of this study was to determine the relationship between the third molar and periodontal status of the adjacent second molar. Fifty patients who had four maxillary and mandibular second molars were consecutively selected for the study subjects. The subjects provided a total of 200 molars, i. e., 100 maxillary and 100 mandibular molars, and classified the groups as follows; third molars that are normally erupted are control group, that are impacted are test 1 group, that are simply extracted are test 2 group, that are surgically extracted are test 3 group. Probing depth, plaque index, gingival index and mobility were measured. The results were as follows. 1. In mesial probing depth, there was no significantly difference. In distal probing depth, there was a significantly difference between control group and test 1 & 3 group in maxilla and between control & test 2 group and test 1& 3 group in mandible(p<0.05). 2. In buccal probing depth, there was a significantly difference between test 2 group and test 3 group in mandible. In lingual probing depth, there was a significantly difference between control group and test 1 & 3 group in mandible(p<0.05). 3. In plaque index, there was a significantly difference between test 1 group and test 2 group in maxilla, between test 1 group and control & test 2 group in mandible(p<0.05). 4. In gingival index, there was a significantly difference between control group and test 1 & 3 group in mandible. In mobility, there was no significantly difference(p<0.05). As a result of this study, the second molars adjacent to the third molars that are impacted or surgically extracted had poor prognosis, so impacted third molars should be extracted in early time and the second molars are actively treated for periodontal health.

IEEE 1149.1의 실시간 신호 시험 구조 설계 (Design of Run-time signal test architecture in IEEE 1149.1)

  • 김정홍;장영식;김재수
    • 한국컴퓨터정보학회논문지
    • /
    • 제15권1호
    • /
    • pp.13-21
    • /
    • 2010
  • 보드에 장착된 소자들을 테스트하기위해 제안된 IEEE 1149.1 시험 구조는 입력으로 TDI 핀을 사용하고 출력으로 TDO 핀을 사용하는 커다란 직렬 쉬프트 레지스터이다. IEEE 1149.1은 보드 수준에서의 테스트는 완벽하게 수행하지만 보드가 시스템에 장착되고 난 후의 수행 중인 시스템 수준에서의 실시간 동작클럭 속도로의 테스트에는 문제가 있다. 즉시험대상 핀의 실시간 동작신호를 시험하기 위하여 직렬 시프트 레지스트 체인들의 출력속도를 동작 클럭의 쉬프트레지스터 배수 이상의 속도로 작동 하여야 한다. 본 논문에서는 시스템 클럭과 동일한 속도로 실시간 신호를 캡쳐하기 위한 실시간 신호 시험 구조를 설계하고 시험 절차를 제안하였다. 제안한 실시간 신호 시험 구조를 Altera의 Max+Plus 10.0을 사용하여 제안한 시험 절차에 따라 시뮬레이션을 수행하였으며, 이를 통해 제안한 시험구조가 정확히 동작함을 확인하였다.

연속형 시스템의 신뢰성 성장 관리 시험 설계 방안 (A Method of Reliability Growth Management Test Design for Continuous System)

  • 서양우;윤정환;이승상;엄천섭
    • 시스템엔지니어링학술지
    • /
    • 제16권2호
    • /
    • pp.87-96
    • /
    • 2020
  • In this paper we proposed the test design method of reliability growth management. First, we presented the process for establishing the reliability growth management test design considering the number of failures and the termination test time. Reliability growth analysis of continuous system was performed in accordance with the test design process presented. In case the reliability test result is not met with the reliability target value after more than three failures occurred, the required test times were analyzed that 1,725 hrs for one corrective action, 1,950 hrs for two corrective actions. If the number of failures is less than three, design a reliability demonstration test according to confidence level 80% and 90% was performed using RGA 11 Software. As a result, it is possible to establish the reliability growth management test design with sufficient use of available resources. The results of this study can be used when establishing a test design for assessment of reliability growth management of all continuous systems.

차세대 블레이드(NRSB-1M/2M)의 마하 스케일 성능시험 (The Mach-scale Performance Test of Next-Generation Blade(NRSB- 1M/2M))

  • 송근웅;김준호;김승호
    • 항공우주기술
    • /
    • 제5권2호
    • /
    • pp.27-36
    • /
    • 2006
  • 본 논문에서는 차세대 블레이드인 NRSB-lM과 NRSB-2M의 성능시험 절차 및 결과에 대해 기술하였다. 축소 블레이드 성능시험으로 공력 성능 시험과 소음 시험을 수행하였다. 공력 성능시험은 회전발란스를 이용하여 로터 추력 및 토오크를 측정하였고, 소음 측정시험은 마이크로폰을 이용하여 1.64D 위치에서 소음을 측정하였다. 측정된 성능 데이터는 무차원화하여 분석하였고, 두 블레이드 결과를 서로 비교하여 NRSB-2 블레이드가 더 좋은 블레이드 임을 확인하였다.

  • PDF

SAT#1 (Preliminary Integration) Test Results of KASS System

  • Jeong, Hwanho;Jang, HyunJin;Kim, Koontack;Lee, Jaeeun;Lee, ByungSeok
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제10권2호
    • /
    • pp.145-151
    • /
    • 2021
  • According to the Korea Augmentation Satellite System (KASS) system milestone, Site Acceptance Test (SAT) has three steps test until the end of the project. SAT#1 is the first time of SAT steps and verify the KASS Reference Station (KRS) and Sub System (S/S) for the monitoring and controllable. After the equipment and software were installed at the Mission Control Center (MCC) with Central Monitoring and Control Simulator (CMS) for the SAT#1, the 1:1 test was progressed when the KRS and S/S are ready to test. SAT#1 has a 10 steps test case and it was progressed each KRS sites. The test was finished throughout the real-time monitoring and the data collection including the data analysis all of the 7 KRS sites. Finally SAT#1 was completed on December 2020 with successfully.