In-Flight and Numerical Drag Prediction of a Small Electric Aerial Vehicle (비행시험과 전산해석을 통한 소형무인기 항력 예측)

  • Jin, Won-Jin;Lee, Yung-Gyo
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.23 no.2
    • /
    • pp.51-56
    • /
    • 2015
  • This paper presents the procedure of drag prediction for EAV-1, based on a numerical analysis correlated to an in-flight test. EAV-1, developed by Korea Aerospace Research Institute, is a small-sized UAV to test a hydrogen-fuel cell power system. The long-endurance test flight of 4.5 hours provides numerous in-flight data. The thrust and drag of EAV-1 during the flight test are estimated based on the wind-tunnel test results for EAV-1's propeller performance. In addition, the CFD analysis using a commercial Navier-Stokes code is carried out for the full-scale EAV-1. The computational result suggests that the initial CFD analysis substantially under-predicts the in-flight drag in that the discrepancy is up to 27.6%. Therefore, additional investigation for more accurate drag prediction is performed; the effect of propeller slipstream is included in the CFD analysis through "fan disk" modelling. Also, the additional drag from airplane trim and load factor that actually exists during the flight test in a circular path is considered. These supplemental analyses for drag prediction turn out to be effective since the drag discrepancy reduces to 2.3%.

Proposal of a Simulated Test Method for the Evaluation of Deformation and Failure Characteristics of Pipe Elbows under Cyclic Loads (반복하중 하의 엘보우 변형 및 손상 특성 평가를 위한 모사시험 방법 제안)

  • Kim, Jin Weon;Lee, Dae Young;Park, Heung Bae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.1-10
    • /
    • 2020
  • This study proposed a simulated test method using ring specimen to evaluate the deformation and failure characteristics of pipe elbows under a large amplitude cyclic load. The validity of the test method was demonstrated by finite element (FE) analysis of pipe elbow and ring specimen under cyclic loads. The results showed that the proposed test method adequately simulates the distribution of circumferential strain at crown of pipe elbows where cracks occur under cyclic loads and presents the cyclic hardening behavior of pipe elbows. The parametric FE analysis showed that consistent simulated test results could be obtained when the test section of the ring specimen is longer than 1/2 of the inner diameter of the ring specimen and the radius of the inner loading jig is less than 1/4 of the inner diameter of the specimen.

Fatigue Crack Propagation Behaviors under the Controlloed Stress Amplitude (하중진폭제어에 따르는 피로균열전파거동)

  • Kim, Sang-Chul;Ham, Kyoung-Chun;Kang, Dong-Myeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.9 no.3
    • /
    • pp.140-148
    • /
    • 1992
  • The effect of mechanical, properties in the plastic zone near the crack-tip was investigated, under various controlled loading conditions, i.e., ${\Delta}K$ increasing, ${\Delta}K$ decreasing, and single overload test. For both ${\Delta}K$ decreasing test and ${\Delta}K$ increasing test with constant stress ratio, it is found that the ratio of material constant m'( ${\Delta}K$ decreasing test) to material constant m( ${\Delta}K$ increasing test) is larger than 1 for n<0.1, and it is equal to 1 for 0.10.2. A modified crack growth rate equation based on Forman's equation which applied stable region of fatigue crack propagation in ${\Delta}K$ decreasing test is proposed. Within the limit of this single overload test, an empirical relation between among the retardation ratio (Nd/ $N^{*}$), the strain hardening exponent (n) and the percent peak load (%PL) has been established.established.

  • PDF

Hydrogeological Characterization of Petroleum Contaminated area in Kangwon (강원 유류오염지역의 수리지질 특성 연구)

  • Choi, Hyun-Mi;Lee, Jin-Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.15 no.2
    • /
    • pp.1-9
    • /
    • 2010
  • Estimations of porosity and bulk density, particle size analysis of soli samples, tracer test and slug test were performed in a petroleum contaminated area of Kangwon for understanding characteristics of the aquifer. Porosities of the samples were estimated 0.158~0.257, and bulk densities were estimated as $1.73\sim2.10\;g/cm^3$. Majority proportion of the soil samples was 0.5~1.0 mm size. In the soil texture triangle, all samples were distributed at sand area. Uniformity coefficients were estimated as 7.71~10.39, and thus all samples were poorly-sorted. In the tracer test, Darcy velocity was estimated to $4.8\times10^{-6}$ cm/day, effective porosity was 0.175, and longitudinal dispersivity was 0.1 m. According to the slug test, hydraulic conductivities of the test wells were estimated as $2.243\times10^{-2}\sim1.634\times10^{-2}$ cm/sec. These hydrogeologic parameters can be used for efficient remediation design of the petroleum contaminated area.

A Study on the Manufacturing of Cellular RubBer Products with NR, SBR, NBR EPDM EPDM (NR, SBR, NBR 및 EPDM 발포(發泡)고무의 제조연구(製造硏究))

  • Choi, Sei-Young;Paik, Nam-Chul
    • Elastomers and Composites
    • /
    • v.16 no.1
    • /
    • pp.3-13
    • /
    • 1981
  • The purpose of this dissertation is to study the physical properties of cellular rubber products for industrial use. Vulcanization characteristics were investigated by usingcure curve that had obtained by means of Rheometer. The results of physical properties, vulcanization characteristics and foaming states are as follows. 1. The test results for vulcanization characteristics of NR compounds indicated that in the recipe R-1. When accelerator D is used, the optimum conditions of vulcanizate are obtained, while formula R-2 and R-3 have shown higher torgue at curing time, $1{\sim}2$ minutes. Cellular rubber product test in terms of compression set and compression deflection has also met the requirements of SAE. 2. For SBR compounds, S-1 formula was the best in terns of vulcanization characteristics, and for the blowing structure of cellular rubber products, formula S-3 in which accelerator M is added was fair. All other test results, such as compression set and compression deflection properties met SAE requirements. 3. NBR compound (N-1) including accelerator TT was the best in terms of vulcanization characteristic and also blowing structure. All other properties listed above met requirements, particulary for oil resistance test. 4. In the test of EPDM compounds, when mixed accelerator, M and TT, is used(formula E-1) the best results were obtained. Since EPDM is hydrocarbon elastomer, oil resistance test failed. All other properties met the requirement specified in SAE.

  • PDF

High Temperature Tensile Strength and Fatigue Life Characteristics for Reduced Activation Ferritic Steel (JLF-1) by TIG Welding (TIG 용접한 저방사화 페라이트강 (JLF-1)의 고온강도 및 피로수명특성)

  • Yoon, Han-Ki;Lee, Sang-Pill;Kim, Sa-Woong;Kohyama, Akira
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1444-1450
    • /
    • 2003
  • The fatigue life and tensile strength of JLF-1 steel (Fe-9Cr-2W-V-Ta) and its TIG weldment were investigated at the room temperature and $400^{\circ}C$. Four kinds of test specimens, which associated with the rolling direction and the TIG welding direction were machined. The base metal of JLF-1 steel represented almost anisotropy in the tensile properties for the rolling direction. And the base metal of JLF-1 steel showed lower strength than that of TIG weldment. Also, the strength of all materials entirely decreased in accordance with elevating test temperature. Moreover, the fatigue limit of weld metal was largely increase than that of base metal at both temperatures. The fatigue limit of JLF-1 steel decreased in accordance with elevating test temperature. The fatigue limit of JLF-1 steel decreased in accordance with elevating test temperature. The SEM fractography of tensile test specimen showed conspicuous cleavage fracture of a radial shape. In case of fatigue life test specimen, there were so many striations at crack initiation region, and dimple was observed at final fracture region as a ductile fracture mode.

A Study on the Construction of Test circuit and Unification of Experiment Method for High Voltage Gas-insulated Load Switch using High Power Testing System (특고압 가스 절연 부하 개폐기의 통합형 대전력 시험 방법 및 회로 구성에 관한 연구)

  • Jung, Heung-Soo;Kim, Min-Young;Kim, Juen-Suk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.36-46
    • /
    • 2008
  • This paper is to study on the Construction of Test circuit and Unification of Experiment Method for high voltage gas-insulated load switch using high power testing system The high power testing system is a equipment to verify electrical and mechanical performance on electrical product. The system consist of short-circuit generator, back-up breaker, making switch, impedance, high voltage transformer, low voltage transformer, measuring and protection system, etc. Using this system, we can test related to high power, for example, short-time current test, active load Current test, magnetizing Current test, capacitive current test, closed loop current test, etc. Standards of high voltage gas-insulated load switch that is in use domestic distribution line are ES 5925-0002, IEC 60265-1, IEC 62271-1 and IEEE C 37.74, etc. In this paper, we standardized on the test procedure, organization of test circuit and analysis of measured data prescribed many difference standards, and applied this test method to 600[MVA] high power testing system. So that we can test the load switch satisfied standards.

Development of Durable Reliability Assessment Methods for Heavy Duty Coatings

  • Kim, Seung-Jin;Jung, Ho;Yang, In-Mo;Tanaka, Takeyuki
    • Corrosion Science and Technology
    • /
    • v.4 no.4
    • /
    • pp.155-163
    • /
    • 2005
  • Heavy duty coating are required to have minimum durable period of 15 years under average usage environment because these paints are coated with purpose of anti-corrosion, antifouling, plastering etc. Onto steel structures constructed upon land and sea and other ferrous structures of electric power generation plants, electricity transmission towers, large structures of various plants, etc. Therefore we tried to estimate heavy duty coating longevity through reliability evaluation method and used combined cyclic anti-conrrosion test method composed of drying, moisturizing and salt spray as for accelerated life test to estimate longevity. Accelerated life test hours to heavy duty coating of first grade (with longevity not less than 15 years) specification may be obtained from troubleless test hours $t_n=\frac{B_p}{n^{1/\beta}}\left[\frac{1n(1-CL)}{1n(1-p)} \right]^{1/\beta}=19.671$ (yr) where shape parameter $\beta=1.1$, confidence level CL=80 %, warranty life $B_{10}=15$ yr and sampling size n=10 (2 sets). Because acceleration factor {AF} found by accelerated test is 41.7, accelerated life test hours required may be represented about 4,132 hr so that if this amount of hours is converted to number of cycles(6 hr/cycle) of complex cycle corrosion resistance test then the amount is tantamount about 690 cycles. That means if there does not occur trouble failure (with defect factor sum not more than 20) during when there is performed 690 cycles of combined cyclic anti-corrosion test to heavy duty coating specimen then it signifies that there can be warranted longevity $B_{10}$ of 15 yr under condition of confidence level CL=80 %.

Obstacle Avoidance and Lane Recognition for the Directional Control of Unmanned Vehicle

  • Kim, Chang-Man;Moon, Hee-Chang;Kim, Sang-Gyum;Kim, Jung-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.34.6-34
    • /
    • 2002
  • 1. Introduction 2. System Configuration 2.1 Control System 2.1.1 Longitudinal control 2.1.2 Lateral control 2.2 Sensor System 2.2.1 Photo interrupt 2.2.2 Ultrasonic sensor 2.3 Vision system 2.4 Communication system 2.4.1 Data communication 2.4.2 Image Communication 3. Test and Result 3.1 Vision test 3.2 Ultrasonic sensor test 4. Conculsion. Acknowledgment References.

  • PDF

The Result of Oral Health Care on Primary School Children Using Dental Caries Activity Test (일부 초등학생의 치아우식활성검사를 이용한 계속구강건강관리 효과)

  • Son, Eun-Yung;Choi, Moon-Sil
    • Journal of dental hygiene science
    • /
    • v.12 no.2
    • /
    • pp.93-102
    • /
    • 2012
  • The purpose of this study was to evaluate the effectiveness of oral health care including some of dental caries activity test on dental clinics of regular visiting on primary school children. The dental surveys and initial caries control and some of dental caries activity test (Alban's, Lactobacillius, S'mutans, un-stimulation saliva test)were performed by trained dental hygienists with dentist from on 6 to 13 years old patients of S dental hospital in Gwangju Metropolitan Cities. The sample size of 39 children (18 in oral health care group, 21 in control group ) and accepted to their parents. The results of caries activity test score(Alban's and Lactobacillius test)were reduced 1.4 to 1.6 times in oral health care group(OHCG). Oral Hygiene Simplified Index of OHCG was reduced 1.6 times during six months and 1 year. DMFT index of OHCG was reduced 1.4 times more than Control Group(CG) after 1 year. DT index of OHCG was reduced 12 times more than Control Group(CG) after 1 year. Dental health capacity of the first perment molar of OHCG was reduced 1.02 times more than CG after 1 year. From the above results, long life related incremental oral health care system has reinforced to primary school children in dental clinic with oral health professional teams.