• Title/Summary/Keyword: Terminal point

Search Result 472, Processing Time 0.024 seconds

Comparison of Recombination Methods ad Cooling Factors in Genetic Algorithms Applied to Folding of Protein Model System

  • U, Su Hyeong;Kim, Du Il;Jeong, Seon Hui
    • Bulletin of the Korean Chemical Society
    • /
    • v.21 no.3
    • /
    • pp.281-290
    • /
    • 2000
  • We varied recombination method of fenetic algorithm (GA), i.e., crossover step, to compare efficiency of these methods, and to find more optimum GA method. In one method (A), we select two conformations(parents) to be recombined by systematic combination of lowest energy conformations, and in the other (B), we select them in a ratio proportional to the energy of the conformation. Second variation lies in how to select crossover point. First, we select it randomly(1). Second, we select range of residues where internal energy of the molecule does not vary for more than two residues, select randomly among such regions, and we select either thr first (2a) or the second residue (2b) from the N-terminal side, or the first (2c) or the second residue (2d) from the C-terminal side in the selected region for crossover point. Third, we select longest such hregion, and select such residue(as cases 2) (3a, 3b, 3c or 3d) of the region. These methods were tested in a 2-dimensionl lattice system for 8 different sequences (the same ones used by Unger and Moult., 1993). Results show that compared to Unger and Moult's result(UM) which corresponds to B-1 case, our B-1 case performed similarly in overall. There are many cases where our new methods performed better than UM for some different sequences. When cooling factor affecting higher energy conformation to be accepted in Monte Carlo step was reduced, our B-1 and other cases performed better than UM; we found lower energy conformers, and found same energy conformers in a smaller steps. We discuss importance of cooling factor variation in Monte Carlo simulations of protein folding for different proteins. (A) method tends to find the minimum conformer faster than (B) method, and (3) method is superior or at least equal to (1) method.

Implicit Scheduling Algorithm for Dynamic Slot Assignment in Wireless ATM Networks (무선 ATM 네트워크에서의 동적 대역 할당을 위한 묵시적 스케쥴링 알고리즘)

  • 황민재;강충구;김용진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.7B
    • /
    • pp.1229-1238
    • /
    • 1999
  • To maximize the statistical multiplexing gain in wireless ATM MAC, a centralized scheduling function must be provided for the dynamic slot assignment in the wireless ATM access point. Exploiting the dynamic parameters received in the wireless ATM access point, the centralized scheduler will execute a dynamic slot assignment to determine bandwidth required for individual wireless terminal. In this paper, we propose a new scheduling algorithm, which can effectively reduce a burden of the explicit signaling requirement of transmitting the dynamic parameters in a timely manner. We have demonstrated that the proposed approach outperforms the existing schemes in terms of the timeliness of transmitting the dynamic parameters, which is a critical factor to the performance of delay-sensitive service classes, and works as an effective means of dynamic slot assignment without heavily relying on the dynamic parameters in the wireless ATM networks.

  • PDF

A Hysteresis Current Controller with Improved Voltage Waveform using N.P.C Structure (N.P.C 구조에 의한 히스테리시스 전류제어기의 전압파형 개선)

  • 김윤호;이병송
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.51-57
    • /
    • 1997
  • A new current controlled PWM technique with N.P.C structure is proposed in this paper. A current controlled PWM technique with neutral-point-clamped pulsewidth modulation inverter composed of main switching devices which operates as switches for PWM and auxiliary switching devices to clamp the output terminal potential to the neutral point potential is described. This inverter output contains less harmonic content as compared with that of a conventional current controlled PWM type. In addition, the proposed current controlled PWM technique has lower switching frequency than that of conventional current controlled PWM technique at the same current limit. Two inverters are compared analytically. The improved voltage waveform of current controlled PWM with N.P.C structure is analyzed and the performance is investigated by the computer simulation.

  • PDF

A study on Improvement of Automatic Generation Control Related Systems for New Energy Management System (자동발전제어(AGC) 운용기선에 관한 연구)

  • Jeon, D.H.;Choo, J.B.;Yoon, Y.B.;Kim, S.H.;Lee, J.S.;Kim, K.H.;Kweon, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.357-359
    • /
    • 2000
  • This paper is to introduce the R&D project called "Improvement of Automatic Gene-ration Control Related Systems for New Energy Management system". The principal objective of this project is to demonstrate AGC operation capabilities that are suitable to new EMS environment and to show the validity of Set-Point Control Method. A number of developments and enhancements have been made to the generator's Remote Terminal Unit in which new ASTC is being developed and installed. The so-called ACC Signal Transfer Card(ASTC) will include RTU's Set-Point Control capabilities. It is expected that over next few months both RTU & DCS software modifications will be given and a relatively new Set-Point Control Method will be chosen instead of those from more conventional method, pulse control method.

  • PDF

Improvement of Power Generation of Microbial Fuel Cells using Maximum Power Point Tracking (MPPT) and Automatic Load Control Algorithm (최대전력점추적방법과 외부저항 제어 알고리즘을 이용한 미생물연료 전지의 전력생산 최대화)

  • Song, Young Eun;Kim, Jung Rae
    • KSBB Journal
    • /
    • v.29 no.4
    • /
    • pp.225-231
    • /
    • 2014
  • A microbial fuel cell (MFC) and bioelectrochemical systems are novel bioprocesses which employ exoelectrogenic biofilm on electrode as a biocatalyst for electricity generation and various useful chemical production. Previous reports show that electrogenic biofilms of MFCs are time varying systems and dynamically interactive with the electrically conductive media (carbon paper as terminal electron acceptor). It has been reported that maximum power point tracking (MPPT) method can automatically control load by algorithm so that increase power generation and columbic efficiency. In this study, we developed logic based control strategy for external load resistance by using $LabVIEW^{TM}$ which increases the power production with using flat-plate MFCs and MPPT circuit board. The flat-plate MFCs inoculated with anaerobic digester sludge were stabilized with fixed external resistance from $1000{\Omega}$ to $100{\Omega}$. Automatic load control with MPPT started load from $52{\Omega}$ during 120 hours of operation. MPPT control strategy increased approximately 2.7 times of power production and power density (1.95 mW and $13.02mW/m^3$) compared to the initial values before application of MPPT (0.72 mW and $4.79mW/m^3$).

Regional Distribution Characteristics of Total Gaseous Mercury in Air-Measurements from Urban and Mountainous Sites in Korea (대기 중 수은의 지역적 분포특성에 대한 비교연구-한반도의 도심과 산악지역을 중심으로)

  • 김민영;김기현
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.39-50
    • /
    • 2001
  • The spatial distribution characteristics of airborbe mercury(Hg) were investigated used its concentration data from six measurement sites selected to represent:(1) three terminal sites with heavy traffic loads in urban area, (2) one urban residential site and (3) two mountainous sites in Korea. The measurement data obtained during September 1997 through May 1998 indicated that the mean concentration of Hg from different study sites were comparably high with the mean values spanning from 5-9ng./㎥. The concentration from all those sites were systmatically high compared to those of most background sites around world or to other Korean sites investigaed previously. When results of correlation analysis between Hg and relevant parameters were compared among different study sites. temperature was most frequently found out to be in strong correlation with Hg concentrations. Results of factor analysis also indicated that Hg concentrations could be affected simultaneously by th factors affecting such parameters as ozone, temperature, ozone, carbon monoxide, and PM. The findings of enhanced Hg levels from Ji-Ri Mountain relative to terminal site suggest that is distributions may be rather homogeneous not enough to clearly distinguish areal differences and the associated source signatures between urban and rural area. The existence of systmatically high concentrations from all investigated sites also indicate that the impact of its source processes should be quite ubiquitous, while highly variable in relatively long term scale.

  • PDF

Fault Location for Incomplete-Journey Double-Circuit Transmission Lines on Same Tower Based on Identification of Fault Branch

  • Wang, Shoupeng;Zhao, Dongmei;Shang, Liqun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.1754-1763
    • /
    • 2017
  • This paper analyses the characteristics of incomplete-journey double-circuit transmission lines on the same tower formed by single-circuit lines and double-circuit lines, and then presents a fault location algorithm based on identification of fault branch. With the relationship between the three-phase system and the double-circuit line system, a phase-mode transformation matrix for double-circuit lines can be derived. Based on the derived matrix, the double-circuit lines with faults can be decoupled, and then the fault location for an incomplete-journey double-circuit line is achieved by using modal components in the mode domain. The algorithm is divided into two steps. Firstly, the fault branch is identified by comparing the relationships of voltage amplitudes at the bonding point. Then the fault location, on the basis of the identification result, is calculated by using a two-terminal method, and only the fault distance of the actual fault branch can be obtained. There is no limit on synchronization of each terminal sampling data. The results of ATP-EMTP simulation show that the proposed algorithm can be applied within the entire line and can accurately locate faults in different fault types, fault resistances, and fault distances.

Large deflections of spatial variable-arc-length elastica under terminal forces

  • Phungpaingam, Boonchai;Athisakul, Chainarong;Chucheepsakul, Somchai
    • Structural Engineering and Mechanics
    • /
    • v.32 no.4
    • /
    • pp.501-516
    • /
    • 2009
  • This paper aims to study the large deflections of variable-arc-length elastica subjected to the terminal forces (e.g., axial force and torque). Based on Kirchhoff's rod theory and with help of Euler parameters, the set of nonlinear governing differential equations which free from the effect of singularity are established together with boundary conditions. The system of nonlinear differential equations is solved by using the shooting method with high accuracy integrator, seventh-eighth order Runge-Kutta with adaptive step-size scheme. The error norm of end conditions is minimized within the prescribed tolerance ($10^{-5}$). The behavior of VAL elastica is studied by two processes. One is obtained by applying slackening first. After that keeping the slackening as a constant and then the twist angle is varied in subsequent order. The other process is performed by reversing the sequence of loading in the first process. The results are interpreted by observing the load-deflection diagram and the stability properties are predicted via fold rule. From the results, there are many interesting aspects such as snap-through phenomenon, secondary bifurcation point, loop formation, equilibrium configurations and effect of variable-arc-length to behavior of elastica.

The Analysis on the Determinations Factors of Container Port Competitiveness (컨테이너 항만경쟁력 결정요인 분석)

  • Lee, Ki-Tae;Baek, In-Hum
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.1
    • /
    • pp.262-272
    • /
    • 2015
  • The aim of this study is to analysis factors that determine the competitiveness of container ports using the KJ and AHP methods. For this, 54 detailed attributing factors were identified both by previous studies and port users. 24 attributing factors were identified by a group of port experts. also, These were grouped 18 detailed attributing factors into 6 attributing factors by a group of port experts using the KJ method. These were made into a model of hierarchical structure with 3 levels, taking 1 goal factor, 6 evaluation factors and 18 detailed evaluation factors. The collected date of questionnaires were analyzed by a group of port experts using the AHP method. The analysis result of the evaluation factors in container port shows that port cargo volume is the most important factor, followed by port location, port cost, port service, port facility and port management. The analysis results of detailed evaluation factors in container port shows that import and export cargo volume is the most important factor, followed by transshipment cargo volume, distance from main trunk, cargo handling cost, distance from the point of importing and exporting, speediness of cargo handling, stability of cargo handling, vessel/cargo cost in port entry and leaving, punctuality in port entry and leaving, number and length of berth, collateral service cost, terminal area, hinterland accessibility, ability of terminal operation company, front depth of berth, etc.

$^{131}I$-O-Iodohippurate Renogram in Epidemic Hemorrhagic Fever (유행성(流行性) 출혈열환자(出血熱患者)의 Radio Renogram)

  • Kim, Myung-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.1 no.2
    • /
    • pp.75-84
    • /
    • 1967
  • $^{131}I$-labeled-O-iodohippurate renograms in 15 cases of epidemic hemorrhagic fever(E.H. fever)during oliguric, diuretic and convalescent phase were analysed quantitatively and qualitatively, namely by its configuration, Tmax T 1/2 and renal index of Hirakawa. The results were as following: 1) Changes on the renograms in E.H. fever showed simultaneous bilateral renal impairment. 2) The characteristic configurations of renogram in the oliguric phase were: (1) Moderately decreased absolute amplitude of initial spike. (2) Continous rising second slope. (3) No appearance of terminal descent. Those were mast likely to those of renograms in acute ureteral obstruction or acute dehydration state. 3) During the diuretic phase, the renogram showed the point of maximal amplitude, but the steepness of 2nd slope was markedly decreased. The appearance of terminal descents was observed with unusually high amplitude despite of the tremendously large amount of urinary output during this phase. 4) In convalescence, the renograms were essentially normal in configuration, but the renal index of Hirakawa was not recovered until this phase. 5) Renograms in E.H. fever showed the characteristic patterns in each phase of its clinical course. 6) $^{131}I$-OIH-Renogram might be an useful method for the evaluation of renal function in E.H. fever during its course.

  • PDF