• Title/Summary/Keyword: Tension wound

Search Result 83, Processing Time 0.027 seconds

Venous Anastomosis with Dorsal Veins Using Additional Incisions after Wound Closure in Metacarpophalangeal Joint Level Replantation

  • Cho, Sang Hyun;Bahar-Moni, Ahmed Suparno;Whang, Jong Ick;Seo, Hyeung Gyo;Park, Hyun Sik;Kim, Ji Sup;Park, Hyun Chul
    • Archives of Reconstructive Microsurgery
    • /
    • v.25 no.1
    • /
    • pp.12-14
    • /
    • 2016
  • In cases of replantation, accurate closure of all structures, including bone, tendons, arteries, nerves, and veins is essential. Among these, the vein is a weaker structure and is damaged severely in most amputation cases. After fixation of bone, repair of tendons, nerves, and arteries, surgeons often experience difficulty in performing venous anastomoses. We found that in such cases, venous anastomosis is easy to perform using an additional incision after closure of the original wound. In a 33-year-old male patient with amputation of all four fingers at the metacarpophalangeal joint level, venous anastomoses were performed with dorsal veins using additional incisions after completion of the fixation of bones and repair of all other structures and closure of the skin due to surgical site tension.

The Effectiveness of Progressive Tension Suture at Latissimus Dorsi Muscle Harvest (광배근 근피판 거상 후 점진적 긴장 봉합술의 유용성)

  • Moon, Joo Bong;Park, Jung Min;Kwon, Yong Seok;Lee, Keun Cheol;Kim, Seok Kwun;Cho, Se Heon
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.611-616
    • /
    • 2007
  • Purpose: The latissimus dorsi muscle flap is a versatile flap used in a variety of reconstructive procedures. The most common complication of LD muscle flap is donor site seroma, reported to occur in 20 to 79 percent of cases. The formation of dead space under the flap is intimately associated with seroma formation. The authors think that the use of progressive tension suture at closing donor site can decrease the formation of dead space and ultimately reduce the incidence of donor site seroma. Methods: A retrospective review was performed with 38 patients who underwent latissimus dorsi muscle harvest for breast reconstruction from March 2003 to September 2004. Progressive tension sutures were used during donor site closure in 22 patients. This group was compared with controls group(16 patients) who underwent latissimus dorsi muscle harvest without using this technique. Operation time, length of hospital stay, period of drainage, complication, and satisfaction about postoperative scar of donor site were examined. Results: The average length of hospital stay was 10.2 days and 12.7 days, and the mean duration of drainage were 7.3 days and 11.7 days in each progressive suture group and control group. These results were statistically significant (p<0.05). In the 22 patients who underwent progressive tension suture, none had seroma, hematoma or skin necrosis. In control group(16 patients), there happened one seroma formation and one partial skin necrosis. These complications were healed by aspiration of seroma and wound revision. The patients' satisfaction was not statistically significant, but the higher points were given by the patients who underwent progressive tension suture. Conclusion: This technique, progressive tension suture, is an effective method to reduce or eliminate donor site seroma, which is the most common complication associated with latissimus dorsi muscle harvest.

Inlay graft of acellular dermal matrix to prevent incisional dehiscence after radiotherapy in prosthetic breast reconstruction

  • Kim, Mi Jung;Ahn, Sung Jae;Fan, Kenneth L.;Song, Seung Yong;Lew, Dae Hyun;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.46 no.6
    • /
    • pp.544-549
    • /
    • 2019
  • Background As the indications for postmastectomy radiotherapy expand, innovative solutions are required to reduce operative complications and reconstructive failure after prosthetic breast reconstruction. In this study, we investigated the effectiveness of acellular dermal matrix (ADM) inlay grafts in preventing postoperative wound dehiscence of irradiated breasts in the context of prosthetic breast reconstruction. Methods A retrospective analysis was conducted of 45 patients who received two-stage prosthetic reconstruction and radiotherapy following mastectomy. An ADM graft was placed beneath the incisional site during the second-stage operation in 19 patients using marionette sutures, whereas the control group did not receive the ADM reinforcement. Patient demographics and complications such as wound dehiscence, capsular contracture, peri-prosthetic infection, cellulitis, and seroma were compared between the two groups. Results During an average follow-up period of 37.1 months, wound dehiscence occurred significantly less often in the ADM-reinforced closure group (0%) than in the non-ADM group (23.1%) (P=0.032). There was no significant difference between the two groups in relation to other complications, such as capsular contracture, postoperative infection, or seroma. Conclusions The ADM inlay graft is a simple and easily reproducible technique for preventing incisional dehiscence in the setting of radiotherapy after prosthetic breast reconstruction. The ADM graft serves as a buttress to offload tension during healing and provides a mechanical barrier against pathogens. Application of this technique may serve to reduce complications in prosthetic breast reconstruction after radiotherapy.

A Study on the Optimum Evaluation Method for Tensile NOL Ring Specimen Manufactured by Filament Winding Process (Filament Winding에 의해 제조된 복합재료 NOL Ring시험편의 최적 인장강도 평가법에 관한 연구)

  • 김윤해;권술철;임철문
    • Composites Research
    • /
    • v.14 no.2
    • /
    • pp.8-12
    • /
    • 2001
  • Filament Winding Process is a comparatively simple operation in which continuous reinforcements in the form of roving are wound over a rotating mandrel. It is well established and versatile method for storage tanks and pipes for the chemical and other industries. In this study, tensile strength of a filament wound ring specimens were evaluated by a split disk test fixture and a dress disk test fixture. The results obtained from experiments were compared with the theoretical values from the rule of mixtures. The purpose of this paper is the suggestion of an appropriate test method for the evaluation of tensile properties of filament wound structures. The tensile strength of a ring specimen tested by the dress disk test showed better agreement with the theoretical values than those tested by the split disk test because of higher stress concentration in edges of a split disk test fixture. The results showed that the tensile strength of a ring specimen was influenced by the geometry of test fixture, the continuity of fibers, fiber-tension, fiber-end and stress concentration in specimen.

  • PDF

Reconstruction of post-burn anterior neck contractures using a butterfly design free anterolateral thigh perforator flap

  • Lellouch, Alexandre G.;Ng, Zhi Yang;Pozzo, Victor;Suffee, Tabrez;Lantieri, Laurent A.
    • Archives of Plastic Surgery
    • /
    • v.47 no.2
    • /
    • pp.194-197
    • /
    • 2020
  • Anterior neck burns represent a major reconstructive challenge due to severe sequalae including restriction in movement and poor aesthetic outcomes. Common treatment options include skin grafting with/without dermal matrices, and loco-regional and distant free flap transfers with/without prior tissue expansion. Such variation in technique is largely influenced by the extent of burn injury requiring resurfacing. In order to optimize like-for-like reconstruction of the anterior neck, use of wide, thin and long flaps such as the anterolateral thigh (ALT) perforator flap have been reported with promising results. Of note, some patients have a tendency towards severe scar contractures, which may be contributed by the greater extent of inflammation during wound healing. We report our experience at 4 years' followup after secondary reconstruction of severe, anterior neck burn contractures in two patients by harvesting the ALT flap with a butterfly design. This technique provides adequate wound resurfacing of the burned neck and surrounding areas, and provides good neck extensibility by addressing both anterior and lateral aspects of the scar defect simultaneously. Such a flap design reduces tension on wound edges and thus, the risk of contracture recurrence in what remains a particularly challenging type of burn reconstruction.

Theatrical Research an Generated Power of Float-Counterweight Wave Converters (부유체-균형추 파력발전장치의 전력에 대한 이론적 연구)

  • Lee, Sung-Bum;Lee, Seung-Keon;Moon, Byung-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.3
    • /
    • pp.26-32
    • /
    • 2015
  • The authors are developing a motion of floater body type wave energy converter of the float-counterweight system. This consists of the driving pulley, wire, float and counterweight suspended from idler pulleys and rachet mechanism. Though it has succeeded in solving the major structural strength problem in which the floats would slam against adjacent structure(s) by wave load acting horizontally. In order to overcome this problem. We propose a new system in which the wire transmitting the power is wound around the pulleys and the float receiving the wave power is pulled by the wire from both its upper and lower ends to avoid the occurrence of slackening during the wave cycle. In the paper, we developed the dynamics model for the proposed system. Energy gain has been calculated for realistic wave conditions and compared with the original float-counterweight device. The important differences from the float-counterweight system are that (1) both upward and downward motions of water surface can be utilized without problem. (2) slackening of energy gain and wire tension are effectively suppressed, and (4) for the same time averaged energy gain, the maximum wire tension is fairly lowered.

Experimental Study on Current Capacity of Superconducting Solenoids with Large Inner Diameter (대구경 초전도 솔레노이드 코일의 전류특성의 실험적 고찰)

  • Bae, J.H.;Sim, K.D.;Choi, S.J.;Kim, S.W.;Cho, J.W.;Lee,, E.Y.;Kwon, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.688-690
    • /
    • 2002
  • The quench current characteristics of the superconducting solenoids with large diameter were experimentally investigated. Three solenoids with the inside diameter of 450mm were fabricated and tested for various winding tensions and epoxy impregnation conditions. The highest quench current was obtained in the solenoid impregnated with epoxy after wound with winding tension of 20 percents. Although the training effect in the solenoid appeared after epoxy impregnation, The quench current of solenoid impregnated with epoxy was higher than that before impregnation. The test results and discussions were presented.

  • PDF

Vacuum-assisted Closure Therapy for Treating Patients with Severe Subcutaneous Emphysema (피하기종의 Vacuum-assisted Closure Therapy)

  • Oh, Tak-hyuk;Lee, Sang Cjeol;Lee, Deok Heon;Cho, Joon Yong
    • Journal of Trauma and Injury
    • /
    • v.28 no.4
    • /
    • pp.276-279
    • /
    • 2015
  • Subcutaneous emphysema is a benign condition following trauma (pneumothorax and oropharyngeal), cervical or thoracic procedures, and mediastinal infection. However, severe subcutaneous emphysema may be related to serious complications such as respiratory failure, airway compromise, and tension- related phenomena. Many alternative therapies have been tried to treat patients with this condition. We report our experience with vacuum-assisted closure therapy for treating patients with severe subcutaneous emphysema.

  • PDF

Design and Manufacture for the 0.7MJ SMES Coil (0.7MJ SMES Coil 설계 및 제작)

  • Kim, H.J.;Seong, K.C.;Cho, J.W.;Lee, E.Y.;Ryu, K.S.;Ryu, K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.140-142
    • /
    • 1998
  • The major part of SMES (Superconducting Magnetic Energy Storage) system consist of the superconducting coil, cryostat and current lead, power converter. The 0.7MJ SMES coil was a design and manufacture by using SMES device that we developed a design code. A SMES coil was wound with high winding tension in order to prevent wire motion from Lorentz force. This paper described optimum design for the SMES coil.

  • PDF

A Study on the Processing Parameters of Filament Winding with Design of Experiment (실험계획법을 이용한 필라멘트 와인딩 공정변수에 대한 연구)

  • 최창근;이중희;김병선;김병하;황병선
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.208-211
    • /
    • 2000
  • Processing parameters of filament winding were investigated by using design of experiment. To understand 4 main effects(fiber tension, impregnation pressure, processing rate, and temperature) and 3 interactions, $L_{27}(3^{13})$ orthogonal array table was adopted. The used materials were carbon fiber and epoxy resin. Split disk test and short-beam test, which are the general test methods for filament wound composite material, were selected as evaluation methods for a filament would part. The optimal processing parameters for the filament winding were easily found through the analysis of variance of the experimental results.

  • PDF