• Title/Summary/Keyword: Tensile strength test

Search Result 2,696, Processing Time 0.034 seconds

Experimental Study on Tensile Fatigue Strength of the High Strength Bolts (고장력볼트의 인장피로강도에 관한 실험적 연구)

  • Han, Jong Wook;Park, Young Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.2A
    • /
    • pp.165-170
    • /
    • 2008
  • New high strength bolts are required due to the development of the high strength steel, the ultra-thick steel plates, and the long-span bridge, though high strength bolts with tensile strength of 1,000 MPa are mainly used in construction site of every country. The high strength bolts are often subjected to a repeated tension-type of loading in which the fatigue failure is a major mode of failure. However, the theoretical and experimental study for the fatigue failure of tension bolt has not been well established in Korea. In this study, we performed a tensile fatigue test of F8T, F10T and F13T, F13T-N high strength bolts under tension. We proposed three fatigue strength specifications by performing 95% survival probability analysis for F8T, F10T, F13T, and F13T-N bolt under the $2{\times}10^6$ cycles of repeated loading. And the fatigue strength for the advanced screw thread shape bolt developed in this study are compared with the previous KS screw thread shape bolt.

A STUDY ON TENSILE STRENGTH AND PHYSICAL ALTERATION OF THERMALLY RECYCLED METAL BRACKETS (열처리한 재생금속 bracket의 인장강도와 물리적 변화에 관한 연구)

  • Park, Chang-Gee
    • The korean journal of orthodontics
    • /
    • v.15 no.2
    • /
    • pp.261-269
    • /
    • 1985
  • The purpose of this study was to measure and compare tensile strength for 3 types of new direct-bond brackets and the same brackets after recycling and to evaluate recycled brackets to determine the extent of physical alteration after recycling. Three types of new direct-bond brackets were bonded to recently extracted human premolar teeth and the tensile strength was measured by Universal Testing Machine. The brackets were recycled by thermal process and the tensile test was repeated. To determine the extent of physical alteration after recycling, the slot width and the hardness of metal brackets were measured and to analyze the microstructure of the brackets, photographs of the bracket microstructure were taken. Following results were obtained: 1. The tensile strength of recycled brackets was lower than that of new brackets, but there was no statistically significant difference. (p>0.05) 2. In the new and recycled brackets, the tensile strength of mini-mesh base bracket was statistically higher than that of conturlok base bracket, $(p\leq0.05)$ but there was no statistically significant difference between production of other companies. (p>0.05) 3. The slot width of metal bracket was enlarged from 0.459mm to 0.469mm as a result of the recycling process. (p>0.005) 4. As temperature was increased in thermal treatment, the grains of bracket metal gradually became coarser and the hardness was decreased.

  • PDF

Analysis of Tensile Strength Changes by Outdoor Exposure of Scaffolding PP Fiber Rope (달비계용 PP섬유로프의 야외노출에 따른 인장강도 변화 분석)

  • Sung-Yun Kang;Kihyo Jung
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.3
    • /
    • pp.31-36
    • /
    • 2023
  • The use of hanging scaffolding for exterior wall painting and cleaning in building construction and maintenance carries the inherent risk of fall accidents. While periodic rope replacement is crucial for preventing accidents resulting from rope breakage, current regulations lack specificity in determining appropriate disposal period for fiber ropes. This study analyzed the tensile strength of the most commonly used PP fiber ropes with different diameters (16 mm, 20 mm) in the domestic construction industry. Additionally, the effect of outdoor exposure was examined by measuring the tensile strength of new ropes and ropes exposing to outdoor conditions for 30 days and 90 days. The results showed that the new ropes and those exposed to outdoor for 30 days met the KS (Korean Standards) criteria for tensile strength. However, a significant decrease in tensile strength was observed in ropes exposed to outdoor for 90 days compared to both the new ropes and those exposed for 30 days. Furthermore, the ropes exposed for 90 days did not meet the KS criteria. These findings indicate the degradation of PP fiber ropes due to UV (Ultra Violet) radiation, highlighting the importance of considering this factor when determining the replacement period for fiber ropes used in scaffolding work.

Study on the Morphological Change of Straight Permanent Waved Hair by Tensile Strength Test (인장강도 측정에 의한 스트레이트 펌 모발의 형태학적 변화에 관한 연구)

  • Roh, Jung-Ae;Chang, Byung-Soo;Choi, Tae-Bu
    • Applied Microscopy
    • /
    • v.39 no.1
    • /
    • pp.49-56
    • /
    • 2009
  • In this study, we investigated tensile properties and ultrastructural changes of straight permed hair using the rheometer and the scanning electron microscopy. First, we compared the morphological characteristic between the virgin hair and the straight permed hair after testing tensile strength. Cuticle cells were heavily lifted off in straight permed hair than in the virgin hair. Cuticle cells were separated by the destruction of intercellular membrane complex and no destruction or damage were found in cytoplasm. In the comparative test for tensile characteristic between the virgin hair and the straight permed hair, tensile distance of the straight permed hair was decreased by 24.5% or 3.05 mm than the virgin hair. The tensile strength was decreased by 34.63% or $5.62\;g/cm^2$ and the maximum stress by 34.59% or 56.12 g. As a result, the tensile property dropped to the lowest level with the straight permed hair than with the bleached hair or the permanent dyed hair of previous studies.

Effect of liners and primers on tensile bond strength between zirconia and resin-based luting agent

  • Jo, Eun-Hye;Huh, Yoon-Hyuk;Ko, Kyung-Ho;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.374-380
    • /
    • 2018
  • PURPOSE. The effect of silica-based glass-ceramic liners on the tensile bond strength between zirconia and resin-based luting agent was evaluated and compared with the effect of 10-methacryloyloxydecyl dihydrogen phosphate (MDP)-containing primers. MATERIALS AND METHODS. Titanium abutments and zirconia crowns (n = 60) were fabricated, and the adhesive surfaces of the specimens were treated by airborne-particle abrasion. The specimens were divided into 5 groups based on surface treatment: a control group, 2 primer groups (MP: Monobond Plus; ZP: Z Prime Plus), and 2 liner groups (PL: P-containing Liner; PFL: P-free Liner). All specimens were cemented with self-adhesive resin-based luting agent. After 24-hour water storage and thermocycling (5,000 cycles, $5^{\circ}C/55^{\circ}C$), the tensile bond strength was measured using a universal testing machine. Failure mode analysis and elemental analysis on the bonding interface were performed. The data were analyzed using Kruskal-Wallis test, Dunn's post hoc test, and Fisher's exact test. RESULTS. The liner groups and primer groups showed significantly higher tensile bond strengths than that of the control group (P<.05). PFL showed a significantly higher tensile bond strength than the primer groups (P<.05). The percentage of mixed failure was higher in the primer groups than in the control group (P<.001), and all the specimens showed mixed failure in the liner groups (P<.001). A chemical reaction area was observed at the bonding interface between zirconia and liner. CONCLUSION. The application of liner significantly increased the tensile bond strength between zirconia and resin-based luting agent. PFL was more effective than MDP-containing primers in improving the tensile bond strength with the resin-based luting agent.

Influence of Si Contents on the Mechanical Properties of Austempered Ductile Iron (오스템퍼드 구상흑연주철의 기계적 성질에 미치는 Si의 영향)

  • Lee, Sang-In;Oh, Young-Kun;Jun, Ghi-Chan
    • Journal of Korea Foundry Society
    • /
    • v.17 no.3
    • /
    • pp.286-291
    • /
    • 1997
  • Influence of Si contents on the mechanical properties and microstructure of austempered ductile iron was investigated. Four different Si contents between 2.0 and 2.9% were used. Austenitizing was performed at $890^{\circ}C$ for 2 hrs and austempering temperatures were both 340 and $380^{\circ}C$ for 0.5, 1, and 2 hrs. Nodule content was more than $300/mm^2$ and nodularity was more than 90%. Microstructure was revealed using nital and retained austenite was measured by x-ray diffractometer. Tensile test, no-notch Charpy impact test and wear test were performed. Tensile strength was improved as Si content increased and both elongation and impact toughness had peak at 2.6%Si. The specimen austempered at $380^{\circ}C$ showed lower tensile strength than that of $340^{\circ}C$, but showed higher elongation. However, austempering temperature of $380^{\circ}C$ was desirable because that of $340^{\circ}C$ was close to lower bainite transformation. As austempering time increased, tensile strength and elongation were improved and optimum condition was obtained for 2 hrs heat treatment.

  • PDF

An investigation on the mechanical properties of cable stitches in weft knitting (위편성 케이블 조직의 편성법에 따른 물성 평가)

  • Choi, Wonseok
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.20 no.4
    • /
    • pp.73-82
    • /
    • 2018
  • This research investigated the mechanical properties of the 4 different types of $3{\times}3$ cable stitches on weft knitted fabrics. The 4 kinds of cable-stitch fabrics were knitted under the same knitting conditions, then the mechanical properties, such as tensile strength, elongation, stiffness, etc. were measured according to the Korean Industrial Standards (KS K 0642). The knitting time for the sample produced by the knitting process 1 was the shortest among the 4 different types of samples. It means that the knitting process 1 would have benefits of higher productivity if there is no yarn breakage during the knitting of the cable stitches. In the test for tensile strength, the samples produced by knitting processes 3 and 4 have tensile values of approximately 8~11% higher than the sample produced by knitting process 1. The test for elongation also shows that the samples produced by knitting processes 3 and 4 have up to 18% higher elongation values than the sample produced by knitting process 1. On the other hand, the stiffness test showed no significant difference between the 4 samples. This study is expected to increase the competitiveness of the local knitting industry as a result of providing basic data on the mechanical properties of special knitted stitches, such as cable stitches.

Mechanical Properties and Fracture Behavior of Cylindrical Shell Type for Unidirectional CFRP Composite Material under Tension Load (원통형 셀 구조를 갖는 한방향 CFRP 적층 복합재료의 정적인장파괴거동)

  • 오환섭
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.273-278
    • /
    • 1998
  • In this paper, basic micro-mechanical properties of unidirectional CFRP composite shell such as bonding strength, fiber volume fraction and void fraction are measured and tensile strength test is performed with a fixture. And then fracture surfaces are observed by SEM. In case of basic micro-mechanical properties, bonding strength is reduce with decreasing of radius of each ply in a shell for the effect of residual stress, fiber volume fraction is smaller than plate, and void fraction is vise versa. For these reason, tensile strength of shell is smaller than plate fabricated with same prepreg. For failure mode shell has many splitted part along its length, and it is assumed that this phenomenon is caused by the difference of bonding strength for residual stress.

  • PDF

Evaluation of Characteristic Improvement of Waste-Polyethylene Asphalt Concrete (폐폴리에틸렌 필름 재활용 아스팔트 콘크리트의 특성 분석)

  • Kim, Kwang-Woo;Li, Xing-Fan;Jeong, Seung-Ho;Lee, Soon-Jae;Lee, Gi-Ho
    • International Journal of Highway Engineering
    • /
    • v.4 no.1 s.11
    • /
    • pp.161-170
    • /
    • 2002
  • This study is a fundamental research for recycling waste polyethylene film(WPF) in asphalt concrete for roadway pavement. The objective of this study is to develop technology of making waste polyethylene asphalt mixture and evaluate properties of the asphalt concrete containing WPF. Asphalt concrete for surface course of pavement was produced through an appropriate mix-design using dense-graded and gap-graded aggregates. Marshall mix design, indirect tensile strength test, wheel tracking test and tensile fatigue test were performed. Test result showed that some WPF asphalt mixtures had a high tensile property and good resistances against rutting and fatigue cracking, compared with normal asphalt mixture.

  • PDF