• 제목/요약/키워드: Tensile Strengths

검색결과 867건 처리시간 0.024초

Size effect on strength of Fiber-Reinforced Self-Compacting Concrete (SCC) after exposure to high temperatures

  • Gulsan, M. Eren;Abdulhaleem, Khamees N.;Kurtoglu, Ahmet E.;Cevik, Abdulkadir
    • Computers and Concrete
    • /
    • 제21권6호
    • /
    • pp.681-695
    • /
    • 2018
  • This pioneer study investigates the size effect on the compressive and tensile strengths of fiber-reinforced self-compacting concrete (FR-SCC) with different specimens, before and after exposure to elevated temperatures. 432 self-compacting concrete (SCC) specimens with two concrete grades (50 and 80MPa) and three steel fiber ratios (0%, 0.5% and 1%) were prepared and tested. Moreover, based on the experimental results, new formulations were proposed to predict the residual strengths for different specimens. A parametric study was also carried out to investigate the accuracy of proposed formulations. Residual strength results showed that the cylinder specimen with dimensions of $100{\times}200mm$ was the most affected, while the cube with a size of 100 mm maintained a constant difference with the standard cylinder ($150{\times}300mm$). Temperature effect on the cube specimen (150 mm) was the least in comparison to other specimen sizes and types. In general, provision of steel fibers in SCC mixtures resulted in a reduction in temperature effect on the variance of a conversion factor. Parametric study results confirm that the proposed numerical models are safe to be used for all types of SCC specimens.

상온과 343℃에서 Alloy 690TT 증기발생기 전열관의 인장물성치 평가 (Evaluation of Tensile Properties of Alloy 690TT Steam Generator Tube at Room Temperature and 343℃)

  • 엄기현;김진원
    • 대한기계학회논문집A
    • /
    • 제38권6호
    • /
    • pp.655-662
    • /
    • 2014
  • 본 논문에서는 상온과 원전 설계온도에서 증기발생기 전열관의 축방향과 원주방향 응력-변형률 거동과 인장물성치를 파악하기 위해서, 튜브 시편과 링 시편을 이용하여 상온과 $343^{\circ}C$에서 Alloy 690TT 전열관에 대한 인장시험을 수행하였다. 축방향 인장시험 결과 상온과 $343^{\circ}C$에서 모두 항복점 현상이 관찰되었으며, $343^{\circ}C$에서는 Serration이 관찰되었다. 축방향과 원주방향 모두 상온에 비해 $343^{\circ}C$에서 강도는 감소하였으나 연신율은 거의 변화가 없었다. $343^{\circ}C$에서 가공경화율은 상온에 비해 약간 감소하였으나, 가공경화 거동의 변화는 없었다. 시험 온도에 관계없이 축방향에 비해 원주방향의 항복강도와 인장강도가 약 5 10% 정도 낮았다. 시편 방향에 관계없이 상온 대비 $343^{\circ}C$에서 Alloy 690TT 전열관의 항복강도와 인장강도 감소는 ASME Sec.II의 온도 보정계수에 의해 예측된 것보다 큰 것으로 확인되었다.

의치상 레진의 표면 전처리가 연성 이장재와의 인장결합강도에 미치는 영향 (EFFECT OF DENTURE BASE SURFACE PRETREATMENTS ON THE TENSILE BOND STRENGTH BETWEEN A RESILIENT LINER AND A PROCESSED DENTURE BASE RESIN)

  • 윤민철;정창모;전영찬
    • 대한치과보철학회지
    • /
    • 제45권5호
    • /
    • pp.621-632
    • /
    • 2007
  • Statement of problem: The failure of adhesion between the resilient denture liner and the denture base is a serious problem in clinic. Purpose: The purpose of this study was to evaluate the effect of denture base resin surface pretreatments (mechanical and/or chemical) on the tensile bond strength between a resilient liner and processed denture resin. Material and method. Acrylic-based resilient liners (Soft liner; GC co., Japan & Coe-Soft; GC America Inc. USA) and silicone-based resilient liners (Mucosoft, Parkell Inc., USA & Dentusil; Bosworth co., USA) were used. Specimens in each soft lining material were divided two groups with or without mechanical pretreatment. Each denture base specimen received 1 of 4 chemical pretreatments including: (1) no treatment, (2) 30-s acetone treatment, (3) 15-s methylene chloride treatment, (4) 180-s methyl methacrylate treatment. All specimens were thermocycled and placed under tension until failure in a universal testing machine. Results: 1. Silicone-based resilient liners exhibited significantly higher tensile bond strengths than acrylic-based resilient liners (P<.05). 2. Grinding the denture base resin improved tensile bond strengths of silicone-based resilient liners, but reduced tensile bond strengths of acrylic-based resilient liners (P<.05). 3. In acrylic-based resilient liners, treating with acetone significantly increased the bond strength of Soft liner and treating with methyl methacrylate significantly increased the bond strength of Coe-Soft (P<.05). However they were not effective compared to silicone-based resilient liner. 4. In silicone-based resilient liners, treating with all chemical etchants significantly increased the bond strength of Mucosoft to denture base, and treating with methylene chloride and methyl methacrylate increased the bond strength of Dentusil to denture base (P<.05). Conclusion: Although chemical and mechanical pretreatments were not effective on tensile bond strength of acrylic-based resilent liner to denture base, treating the denture base resin surface with appropriate chemical etchants after mechanical pretreatment significantly increased the tensile bond strength of silicone-based resilient liner to denture base.

TBM 터널 세그먼트용 강섬유보강 콘크리트의 인장특성 평가 (Evaluation of tensile properties of SFRC for TBM tunnel segment)

  • 문도영;장수호;배규진;이규필
    • 한국터널지하공간학회 논문집
    • /
    • 제14권3호
    • /
    • pp.247-260
    • /
    • 2012
  • TBM 터널 세그먼트의 철근량을 감소시키기 위한 연구로서, 강섬유 보강콘크리트의 사용이 시도되고 있다. 이와 같은 터널 세그먼트에는 철근의 감소로 인해 필요한 인장성능의 확보를 위하여 숏크리트에 사용되는 강섬유에 비해 매우 높은 형상비의 강섬유를 활용하는 것이 필요하다. 본 연구에서는 강섬유의 형상비가 80인 강섬유 콘크리트의 인장특성을 휨시험과 Double Punch Test를 통해 평가하였다. 휨시험결과, 사용된 강섬유의 충분한 부착강도로 인해 30%~150%의 강도 증진을 나타냈으며, 오영훈(2008)의 예측식을 통한 휨인장강도예측이 가능한 것으로 판단된다. 이 실험을 근거로 설계에 필요한 직접인장강도를 ACI와 RILEM의 식에 의해 평가한 결과, 적용기준에 따라 큰 차이가 있는 것으로 나타났다. 또한, DPT 실험을 통해 RILEM에서 권고하고 있는 직접인장강도의 정밀도 있는 예측이 가능한 것으로 판단된다.

스플릿 홉킨슨 압력봉 실험장비를 이용한 암석의 동적 압열인장강도 평가에 관한 연구 (Estimation of Dynamic Brazilian Tensile Strengths of Rocks Using Split Hopkinson Pressure Bar (SHPB) System)

  • 양정훈;안중량;김승곤;송영수;성낙훈;이연규;조상호
    • 터널과지하공간
    • /
    • 제21권2호
    • /
    • pp.109-116
    • /
    • 2011
  • 본 연구에서는 스플릿 홉킨슨 압력봉 실험장비를 적용한 압열인장 실험을 수행하여, 암석의 동적인장강도 및 변형률 속도를 평가하였다. 시료가 파괴되기 전에 시료 내 동적 응력평형상태를 확보하기 위하여 펄스쉐이핑 기법으로 입사파의 증가시간을 제어하였다. 압열인장 실험시료는 Inada 화강암, Kimachi 사암, Tage응회암을 정밀하게 가공하여 제작되었다. 결과로서, Inada 화강암의 동적인장강도는 정적인장강도의 11.9배 이였으며, Kimachi 사암과 Tage 응회암은 각각 8.5배, 9.2배로 평가되었다. 고속카메라를 이용하여 시료 내 축 하중 방향으로 발생하는 인장균열의 발생양상을 관찰하였다.

COMPARISON OF RETENTIVE FORCES OF TEMPORARY CEMENTS AND ABUTMENT HEIGHT USED WITH IMPLANT-SUPPORTED PROSTHESES

  • Lee, Dong-Hee;Suh, Kyu-Won;Ryu, Jae-Jun
    • 대한치과보철학회지
    • /
    • 제46권3호
    • /
    • pp.280-289
    • /
    • 2008
  • STATEMENT OF THE PROBLEM: Recent data regarding the effects the cement type and abutment heights on the retentive force of a prosthetic crown are inconsistent and unable to suggest clinical guidelines. PURPOSE OF THE STUDY: This study evaluated the effects of different types of temporary cements and abutment heights on the retentive strength of cement-retained implant-supported prostheses. MATERIALS AND METHODS: Prefabricated implant abutments, 4 mm in diameter, $8^{\circ}$taper per side, and light chamfer margins, were used. The abutment heights of the implants were 4 mm, 5.5 mm and 7 mm. Seven specimens of a single crown similar to a first premolar were fabricated. Six commercially available temporary cements, TempBond, TempBond NE, Cavitec, Procem, Dycal, and IRM, were used in this study. Twenty-four hours after cementation, the retentive strengths were measured using a universal testing machine with a crosshead speed of 0.5 mm/min. The cementation procedures were repeated 3 times. The data was analyzed using two-way analysis of variance and a Tukey test (${\alpha}$=0.05). RESULTS: The tensile bond strength ranged from 1.76 kg to 19.98 kg. The lowest tensile strengths were similar in the TempBond and Cavitec agents. Dycal showed the highest tensile bond strength (P<0.01). More force was required to remove the crowns cemented to the long abutments (P<0.05). CONCLUSION: TempBond and Cavitec agents showed the lowest mean tensile bond strength. The Dycal agent showed more than double the tensile bond strength of the TempBond agent.

High-Temperature Fracture Strength of a CVD-SiC Coating Layer for TRISO Nuclear Fuel Particles by a Micro-Tensile Test

  • Lee, Hyun Min;Park, Kwi-Il;Park, Ji-Yeon;Kim, Weon-Ju;Kim, Do Kyung
    • 한국세라믹학회지
    • /
    • 제52권6호
    • /
    • pp.441-448
    • /
    • 2015
  • Silicon carbide (SiC) coatings for tri-isotropic (TRISO) nuclear fuel particles were fabricated using a chemical vapor deposition (CVD) process onto graphite. A micro-tensile-testing system was developed for the mechanical characterization of SiC coatings at high temperatures. The fracture strength of the SiC coatings was characterized by the developed micro-tensile test in the range of $25^{\circ}C$ to $1000^{\circ}C$. Two types of CVD-SiC films were prepared for the micro-tensile test. SiC-A exhibited a large grain size (0.4 ~ 0.6 m) and the [111] preferred orientation, while SiC-B had a small grain size (0.2 ~ 0.3 mm) and the [220] preferred orientation. Free silicon (Si) was co-deposited onto SiC-B, and stacking faults also existed in the SiC-B structure. The fracture strengths of the CVD-SiC coatings, as measured by the high-temperature micro-tensile test, decreased with the testing temperature. The high-temperature fracture strengths of CVD-SiC coatings were related to the microstructure and defects of the CVD-SiC coatings.

Tensile bond strength between auto-polymerized acrylic resin and acrylic denture teeth treated with MF-MA solution

  • Thongrakard, Ticha;Wiwatwarrapan, Chairat
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권4호
    • /
    • pp.285-289
    • /
    • 2016
  • PURPOSE. This study evaluated the effect of chemical surface treatment using methyl formate-methyl acetate (MF-MA) solution on the tensile bond strength between acrylic denture teeth and auto-polymerized acrylic resin. MATERIALS AND METHODS. Seventy maxillary central incisor acrylic denture teeth for each of three different brands (Yamahachi New Ace; Major Dent; Cosmo HXL) were embedded with incisal edge downwards in auto-polymerized resin in polyethylene pipes and ground with silicone carbide paper on their ridge lap surfaces. The teeth of each brand were divided into seven groups (n=10): no surface treatment (control group), MF-MA solution at a ratio of 25:75 (v/v) for 15 seconds, 30 seconds, 60 seconds, 120 seconds, 180 seconds, and MMA for 180 seconds. Auto-polymerized acrylic resin (Unifast Trad) was applied to the ground surface and polymerized in a pressure cooker. A tensile strength test was performed with a universal testing machine. Statistical analysis of the results was performed using two-way analysis of variance (ANOVA) and post-hoc Dunnett T3 test (${\alpha}$=.05). RESULTS. The surface treatment groups had significantly higher mean tensile bond strengths compared with the control group (P<.05) when compared within the same brand. Among the surface treatment groups of each brand, there were no significantly different tensile bond strengths between the MF-MA groups and the MMA 180 second group (P>.05), except for the Yamahachi New Ace MF-MA 180-second group (P<.05). CONCLUSION. 15-second MF-MA solution can be an alternative chemical surface treatment for repairing a denture base and rebonding acrylic denture teeth with auto-polymerized acrylic resin, for both conventional and cross-linked teeth.

Polymerization and Optical Properties of Polymers with High Tensile Strength Added Isocyanate Group

  • Sung, A-Young;Ye, Ki-Hun
    • 통합자연과학논문집
    • /
    • 제6권1호
    • /
    • pp.1-7
    • /
    • 2013
  • Polyurethane resin containing isocyanate is marked by excellent tensile and mechanical strengths and this test aims to gauge its applicability as a medical high polymer. Tris [2-(acryloyloxy)ethyl]isocyanurate and hexamethylenediisocyanate were added to a basic mixing ratio of HEMA (2-hydroxyethyl methacrylate), MMA (methyl methacrylate), NVP (n-vinyl-2-pyrrolidone) and crosslink agent, EGDMA (ethylene glycol dimethacrylate) with increasing proportions and copolymerized respectively. Also, the basic physical properties of the polymerized high polymers including refraction rate, tensile strength, light transmission and water content were measured to confirm that they are appropriate as hydrogelcontact lenses. After measuring the physical properties of high performance polymers produced by adding tris [2-(acryloyloxy) ethyl]isocyanurate, it was found that the average tensile strengths of sample TRIS1 to TRIS10 were between 0.285 and 0.612 kgf, while the average values of refractive index were ranged from 1.441 to 1.449 with water content from 30.00 to 37.35%.The measurement of physical properties of the copolymers generated by adding hexamethylenediisocyanate showed that the average tensile strength of sample HEXA1 to HEXA10 ranged from 0.267 to 1.742 kgf, the refractive index ranged from 1.443 to 1.475 and water contents were in the range of 21.22 to 35.58%. In all combinations the transmission rates satisfied the transmittance of general hydrogel contact lenses. From theresults, it is possible to conclude that the produced copolymers can be used as contact lens materials with excellent tensile strength.

Lifetime Assessment for Oil-Paper Insulation using Thermal and Electrical Multiple Degradation

  • Kim, Jeongtae;Kim, Woobin;Park, Hung-Sok;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.840-845
    • /
    • 2017
  • In this paper, in order to investigate the lifetime of oil-paper insulation, specimens were artificially aged with thermal and electrical multiple stresses. Accelerated ageing factors and equivalent operating years for each aging temperatures were derived from results of tensile strengths for the aged paper specimens. Also, the evaluation for the multi-stress aged specimens were carried out through the measurement of impulse breakdown voltage at high temperature of $85^{\circ}C$. The lifetimes of the oil-paper insulations were calculated with the value of 66.7 for 1.0 mm thickness specimens and 69.7 for 1.25 mm thickness specimens throughout the analysis of impulse BD voltages using equivalent operating years, which means that dielectric strengths would not be severely decreased until the mechanical lifetime limit. Therefore, for the lifetime evaluation of the oil-paper insulation, thermal aging would be considered as a dominant factor whereas electrical degradation would be less effective.