References
- Misch CE. Screw-retained versus cement-retained implant- supported prostheses. Pract Periodontics Aesthet Dent 1995;7:15-8
- Chee W, Felton DA, Johnson PF, Sullivan DY. Cemented versus screw-retained implant prostheses: which is better? Int J Oral Maxillofac Implants 1999;14:137-41
- Clayton GH, Driscoll CF, Hondrum SO. The effect of luting agents on the retention and marginal adaptation of the CeraOne implant system. Int J Oral Maxillofac Implants 1997;12:660-5
- Pauletto N, Lahiffe BJ, Walton JN. Complications associated with excess cement around crowns on osseointegrated implants: a clinical report. Int J Oral Maxillofac Implants 1999;14:865-8
- Ramp MH, Dixon DL, Ramp LC, Breeding LC, Barber LL. Tensile bond strengths of provisional luting agents used with an implant system. J Prosthet Dent 1999;81:510-4 https://doi.org/10.1016/S0022-3913(99)70203-9
- Breeding LC, Dixon DL, Bogacki MT, Tietge JD. Use of luting agents with an implant system: Part I. J Prosthet Dent 1992;68:737-41 https://doi.org/10.1016/0022-3913(92)90194-F
- Voitik AJ. The Kulzer abutment luting; Kal technique. A direct assembly framework method for osseointegrated implant prostheses. Implant Soc 1991;2:11-4
- Michalakis KX, Pissiotis AL, Hirayama H. Cement failure loads of 4 provisional luting agents used for the cementation of implant-supported fixed partial dentures. Int J Oral Maxillofac Implants 2000;15:545-9
- Akashia AE, Francischone CE, Tokutsune E, da Silva W, Jr. Effects of different types of temporary cements on the tensile strength and marginal adaptation of crowns on implants. J Adhes Dent 2002;4:309-15
- Bernal G, Okamura M, Munoz CA. The effects of abutment taper, length and cement type on resistance to dislodgement of cement-retained, implant-supported restorations. J Prosthodont 2003;12:111-5 https://doi.org/10.1016/S1059-941X(03)00006-8
- Crim GA, Swartz ML, Phillips RW. Comparison of four thermocycling techniques. J Prosthet Dent 1985;53:50-3 https://doi.org/10.1016/0022-3913(85)90064-2
- Covey DA, Kent DK, St Germain HA, Jr., Koka S. Effects of abutment size and luting cement type on the uniaxial retention force of implant-supported crowns. J Prosthet Dent 2000;83:344-8 https://doi.org/10.1016/S0022-3913(00)70138-7
- Squier RS, Agar JR, Duncan JP, Taylor TD. Retentiveness of dental cements used with metallic implant components. Int J Oral Maxillofac Implants 2001;16:793-8
- Akca K, Iplikcioglu H, Cehreli MC. Comparison of uniaxial resistance forces of cements used with implant- supported crowns. Int J Oral Maxillofac Implants 2002;17:536-42
- Kent DK, Koka S, Froeschle ML. Retention of cemented implant-supported restorations. J Prosthodont 1997;6:193-6 https://doi.org/10.1111/j.1532-849X.1997.tb00090.x
- Schneider RL. Evaluation of the retention of castings to endosseous dental implants. J Prosthet Dent 1987;58:73-8 https://doi.org/10.1016/S0022-3913(87)80147-6
- Lee HY, Lee HS. In vitro study of the tensile bond strength of cement-retained single implant prosthesis by the various provisional luting cements and the surface treatment of abutments. J Korean Acad Prosthodont 2002;40:296-305
- Maxwell AW, Blank LW, Pelleu GB, Jr. Effect of crown preparation height on the retention and resistance of gold castings. Gen Dent 1990;38:200-2
- Koka S, Ewoldsen NO, Dana CL, Beatty MW. The effect of cementing agent and technique on the retention of a CeraOne gold cylinder: a pilot study. Implant Dent 1995;4:32-5 https://doi.org/10.1097/00008505-199504000-00005
- Mansour A, Ercoli C, Graser G, Tallents R, Moss M. Comparative evaluation of casting retention using the ITI solid abutment with six cements. Clin Oral Implants Res 2002;13:343-8 https://doi.org/10.1034/j.1600-0501.2002.130401.x
- Dixon DL, Breeding LC, Lilly KR. Use of luting agents with an implant system: Part II. J Prosthet Dent 1992;68:885-90 https://doi.org/10.1016/0022-3913(92)90544-K
- Mathews MF, Breeding LC, Dixon DL, Aquilino SA. The effect of connector design on cement retention in an implant and natural tooth-supported fixed partial denture. J Prosthet Dent 1991;65:822-7 https://doi.org/10.1016/S0022-3913(05)80021-6
- Goodacre CJ, Kan JY, Rungcharassaeng K. Clinical complications of osseointegrated implants. J Prosthet Dent 1999;81:537-52 https://doi.org/10.1016/S0022-3913(99)70208-8
- Becker W, Becker BE. Replacement of maxillary and mandibular molars with single endosseous implant restorations: a retrospective study. J Prosthet Dent 1995;74:51-5 https://doi.org/10.1016/S0022-3913(05)80229-X
- Singer A, Serfaty V. Cement-retained implant-supported fixed partial dentures: a 6-month to 3-year followup. Int J Oral Maxillofac Implants 1996;11:645-9
- Baldissara P, Comin G, Martone F, Scotti R. Comparative study of the marginal microleakage of six cements in fixed provisional crowns. J Prosthet Dent 1998;80:417-22 https://doi.org/10.1016/S0022-3913(98)70005-8