• 제목/요약/키워드: Temperature wake

검색결과 68건 처리시간 0.024초

휴대용 PC내에 실장된 강제공랭 모듈 주위의 유체유동과 온도분포 (Fluid Flow and Temperature Distribution around a Surface-Mounted Module Cooled by Forced Air Flow in a Portable Personal Computers)

  • 박상희;신대종;이인태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.729-732
    • /
    • 2002
  • This paper reports an experimental study around a module about forced air flow by blower($35{\times}35{\times}6mm^3$) in portable PC(10mm high, 200mm wide, and 235mm long). The channel inlet flow velocity has been varied between 0.26, 0.52 and 0.78m/s. The power input to the module is 4Wthis report, particular attention is directed to the fluid flow and adiabatic wall temperature($T_(ad)$) around a module which is under fluid mechanical and thermal influences of the module. The fluid flow around a module was visualized using PIV system. Liquid crystal thernography is used to determine the adiabatic wall temperature around a heated module on an acrylic board. Plots of $T_(ad)$ (or F) show marked effects of dispersion of thermal wake near the module.

  • PDF

톱니형 휜이 부착된 원주의 근접후류특성 연구 (I) - 와유출 메카니즘의 특성변화 규명 - (Characteristics of Near Wake Behind a Circular Cylinder with Serrated Fins (I) - Mechanism of Vortex Shedding -)

  • 류병남;김경천;부정숙
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1183-1190
    • /
    • 2002
  • An experimental study is performed to investigate the characteristics of near wake behind a circular cylinder with serrated fins using the constant temperature anemometer and through flow visualization. Previous report(Boo et al., 2001) shows that there are three different modes in vortex shedding behavior. This paper is focused on the identification of the physical reasons why the difference iss occured in vortex shedding. The through flow velocity crossing fins decreases as increasing fin height and decreasing fin pitch mainly due to the flow resistence. Vortex shedding is affected strongly by velocity distribution around fin tube, especially by the velocity gradient. The velocity distribution at X/d=0.0 has lower gradient with increasing freestream velocity and fin height and decreasing fin pitch. Those differences in velocity gradients generate different vortex shedding mechanism.

여름철 수면시 온열쾌적감 평가 - 제1보 : 수면 전후 설문에 관하여 - (Evaluation of Thermal Comfort during Sleeping in Summer - Part I : On Results of Questionnaire Before and After Sleep -)

  • 김동규;금종수
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.404-409
    • /
    • 2005
  • This study is to investigate effects of thermal conditions on sleep. Five female university students participated in the sleep experiment. Three temperature levels (22, 26, and $30^{\circ}C$) were given, and relative humidity was maintained to $50\%$. When as subject arrived in the chamber at 9 o'clock in the evening, questionnaire was given to check physical and psychological conditions. After checking conditions, subjects went to bed till 07 : 30 in the morning. Body movement was checked during sleeping. After sleep in the chamber, questionnaire was given to the subject in order to check sleep quality. Subjects evaluated sleep quality by themselves by answering the time they fall asleep and wake up, frequency of wake during sleep, causes of each waking, and feeling after sleep. Sleep quality was rated with 7-point scale. At $30^{\circ}C$ condition, body movement was significantly higher than of other thermal conditions. The best sleep quality was obtained at the $26^{\circ}C$ condition, while the worst sleep was taken at the $30^{\circ}C$ condition.

밀폐공간 내에서 압전세라믹 냉각홴의 열성능에 대한 실험적 연구 (Experimental Study on the Thermal Performance of Piezoelectric Fan in an Enclosure)

  • 박상희;최문철
    • 대한기계학회논문집B
    • /
    • 제30권12호
    • /
    • pp.1173-1180
    • /
    • 2006
  • This study deals with fluid flow and heat transfer around a module cooled by forced air flow generated by a piezoelectric(PZT) fan in an enclosure. The fluid flows were generated by a flexible PZT fan which deflects inside a fluid transport system of comparatively simple structure mounted on a PCB in an enclosure($270\times260\times90mm^3$). Input voltages of 30V and 40V, and a resonance frequency of 28Hz were used to vibrate the cooling fan. Input power to the module was 4W. The height in an enclosure was changed 23$\sim$43mm. The fluid flow around the module was visualized by using PIV system. The temperature distributions around a heated module were visualized by using liquid crystal film. As the height in an enclosure and the input voltage of PZT fan increased, the cooling effect of module using a PZT fan increased. We found that the flow type was T- or Y-shape and the cooling effect was increased by the wake generated by a PZT fan.

Numerical simulation and investigation of jet impingement cooling heat transfer for the rotor blade

  • Peiravi, Amin;Bozorg, Mohsen Agha Seyyed Mirza;Mostofizadeh, Alireza
    • Advances in aircraft and spacecraft science
    • /
    • 제7권6호
    • /
    • pp.537-551
    • /
    • 2020
  • Investigation of leading edge impingement cooling for first stage rotor blades in an aero-engine turbine, its effect on rotor temperature and trailing edge wake loss have been undertaken in this study. The rotor is modeled with the nozzle for attaining a more accurate simulation. The rotor blade is hollowed in order for the coolant to move inside. Also, plenum with the 15 jet nozzles are placed in it. The plenum is fed by compressed fresh air at the rotor hub. Engine operational and real condition is exerted as boundary condition. Rotor is inspected in two states: in existence of cooling technique and non-cooling state. Three-dimensional compressible and steady solutions of RANS equations with SST K-ω turbulent model has been performed for this numerical simulation. The results show that leading edge is one of the most critical regions because of stagnation formation in those areas. Another high temperature region is rotor blade tip for existence of tip leakage in this area and jet impingement cooling can effectively cover these regions. The rotation impact of the jet velocity from hub to tip caused a tendency in coolant streamlines to move toward the rotor blade tip. In addition, by discharging used coolant air from the trailing edge and ejecting it to the turbines main flow by means of the slot in trailing edge, which could reduce the trailing edge wake loss and a total decrease in the blade cooling loss penalty.

압전세라믹 냉각팬에 의한 강제 공랭 모듈 주위의 유체유동과 열전달 특성 (Fluid Flow and Heat Transfer Characteristics around a Surface-Mounted Module Cooled by Forced Air Flow by Piezoelectric Cooling Fan)

  • 박규진;박상희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.272-277
    • /
    • 2003
  • This paper reports the fluid flow and heat transfer around a module cooled by forced air flow generated by a piezoelectric(PZT) cooling fan. A flexible PZT fan with distortion in a fluid transport system of comparatively simple structure which was mounted on a PCB in a parallel-plate channel($450{\times}80{\times}700mm^3$) accelerates surrounding fluid locally. Input voltages of 20-100V and a resonance frequency of 23Hz were used to vibrate the cooling fan. Input power to the module was 4W. The cooling effect using a PZT fan was larger than that of free convection. Fluid flow around the module were visualized by using PIV system. The temperature distribution around heated module were visualized by using liquid crystal film(LCF). We found that the flow type was y-shaped and the cooling effect was increased by the wake generated by a piezoelectric cooling fan.

  • PDF

흐름 영각에 따른 강제공랭 모듈 주위의 열전달 특성에 관한 연구 (A Study on the Heat Transfer Characteristics Around a Surface-Mounted Air-Cooled Module for the Flow Angle-of-Attack)

  • 박상희;신대종
    • 대한기계학회논문집B
    • /
    • 제26권9호
    • /
    • pp.1267-1275
    • /
    • 2002
  • An experimental study was performed to investigate adiabatic wall temperature and heat transfer coefficient around a module cooled by forced air flow. The flow angle of attack to the module were 0$^{\circ}$and 45$^{\circ}$. In the first method, inlet air flow(1~7m/s) and input power.(3, 5, 7W) were varied after a heated module was placed on an adiabatic floor(320$\times$550$\times$1㎣). An adiabatic wall temperature was determinated to use liquid crystal film. In the second method to determinate heat transfer coefficient, inlet air flow(1~7m/s) and the heat flux of rubber heater(0.031~0.062W/$m^2$) were varied after an adiabatic module was placed on rubber heater covering up an adiabatic floor. Additional information is visualized by an oil-film method of the surface flow on the floor and the module. Plots of $T_{ad}$ and $h_{ad}$ show marked effects of flow development from the module and dispersion of thermal wake near the module. Certain key features of the data set obtained by this investigation may serve as a benchmark for thermal-design codes based on CFD.

열성층유동장에 놓인 원주후류의 특성에 대한 연구 (3) -선형열원으로부터의 난류확산- (Study on the Characteristics of Cylinder Wake Placed in Thermally Stratified Flow(III) - Turbulent Dispersion from a Line Heat Source-)

  • 김경천;정양범
    • 대한기계학회논문집
    • /
    • 제19권5호
    • /
    • pp.1300-1307
    • /
    • 1995
  • The effect of thermal stratification on the turbulent dispersion from a fine cylindrical heat source was experimentally examined in a wind tunnel with and without a strong temperature gradient. A 0.5 mm dia. nichrome wire was used as a line heat source. Turbulent intensities, r.m.s. value of temperature and convective heat fluxes were measured by using a hot-wire and cold-wire combination probe. The results show that the peack value and the spread of the vertical turbulent intensity for the stratified case are far lower than those in the neutral case, which indicates that the stable temperature gradient suppresses the vertical velocity component. All of the third order moments including heat fluxes measured in the stable condition have very small values than those of the neutral case. This nature suggests that the decrease of scalar fluctuations in the stably stratified flow is mainly due to the suppression ofthe turbulent diffusion processes by the stable stratification. A simple gradient model with a composite timescale which has a simple weighted algebraic mean between dynamic and thermal time scale yields reasonably good numerical values in comparison with the experimental data.

NBTI 노화 효과를 고려한 헤더 기반의 파워게이팅 구조 (Header-Based Power Gating Structure Considering NBTI Aging Effect)

  • 김경기
    • 대한전자공학회논문지SD
    • /
    • 제49권2호
    • /
    • pp.23-30
    • /
    • 2012
  • 본 논문에서는 음 바이어스 온도 불안정성 (NBTI) 효과에 의해서 야기되는 파워 게이팅 구조의 성능 저하와 증가하는 기상시간을 보상하기위한 새로운 적응형 헤더기반의 파워 게이팅 구조를 제안한다. 제안된 구조는 두 개의 패스 (two-pass)를 가지는 파워 게이팅 구조에 기반을 둔 폭 변화 헤더(header)와 적응형 제어를 위한 새로운 NBTI 센싱 회로로 구성된다. 본 논문의 시뮬레이션 결과는 적응형 제어를 하지 않는 파워 게이팅의 시뮬레이션 결과와 비교되며, 그 결과는 파워 게이팅 구조에서 누설 전력과 돌입 전류(rush current)을 작게 유지하면서 회로 지연과 기상시간에 대한 NBTI 의존성이 단지 3% 와 4% 내로 줄어든다는 것을 보여준다. 본 논문에서는 45nm CMOS 공정과 NBTI 예측 모델이 제안된 회로를 구성하기 위해서 사용된다.

사각 둔각물체 주위의 반응유동장에 대한 수치적 연구 (Numerical Study on the Reacting Flow Field abound Rectangular Cross Section Bluff Body)

  • 이정란;이의주
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.64-69
    • /
    • 2013
  • 본 연구에서는 엔진 나셀 화재를 모사하고 이전의 실험결과를 보충하기위해 이차원 둔각물체 주위의 반응유동장에 대하여 수치해석을 수행하였다. Direct numerical simulation (DNS) 기반의 fire dynamic simulator (FDS)를 이용하여 반응유동장의 특성을 조사하였고, 실험결과와의 비교를 통해 화학반응식을 결정하였다. 산화제는 공기를 사용하였고, 연료는 메탄을 사용하였다. 동축류와 대향류 분사 모두의 경우에 화염의 안정성이나 모양은 둔각물체 주위의 와 강도와 크기에 크게 영향을 받았다. 동축류 분사의 경우 계산에 통한 화염소화한계를 결정하였는데 연료유속이 커질수록 공기의 유속 또한 커지는 경향이 있었고, 그 속도들 또한 기존의 실험결과와 잘 일치함을 볼 수 있었다. 유동장 특성에 대한 화학반응의 효과를 고찰하기 위해 반응이 없는 경우를 계산하여 비교하였다. 모든 경우에 비반응 유동장에 비해 반응 유동장의 후류와는 크기도 감소하고 세기도 감소함을 볼 수 있었는데 이는 반응에 의한 후류의 온도증가가 유체의 밀도 및 모멘텀을 감소시켰기 때문으로 판단된다.