• Title/Summary/Keyword: Temperature stability time

Search Result 874, Processing Time 0.023 seconds

Atmospheric Stability Evaluation at Different Time Intervals for Determination of Aerial Spray Application Timing

  • Huang, Yanbo;Thomson, Steven J.
    • Journal of Biosystems Engineering
    • /
    • 제41권4호
    • /
    • pp.337-341
    • /
    • 2016
  • Purpose: Evaluation of atmospheric conditions for proper timing of spray application is important to prevent off-target movement of crop protection materials. Susceptible crops can be damaged downwind if proper application procedure is not followed. In our previous study, hourly data indicated unfavorable conditions, primarily between evening 18:00 hrs in the evening and 6:00 hrs next morning, during clear conditions in the hot summer months in the Mississippi delta. With the requirement of timely farm operations, sub-hourly data are required to provide better guidelines for pilots, as conditions of atmospheric stability can change rapidly. Although hourly data can be interpolated to some degree, finer resolution for data acquisition of the order of 15 min would provide pilots with more accurate recommendations to match the data recording frequency of local weather stations. Methods: In the present study, temperature and wind speed data obtained at a meteorological tower were re-sampled to calculate the atmospheric stability ratio for sub-hour and hourly recommendations. High-precision evaluation of temperature inversion periods influencing atmospheric stability was made considering strength, time of occurrence, and duration of temperature inversion. Results and Discussion: The results indicated that atmospheric stability could be determined at different time intervals providing consistent recommendations to aerial applicators, thereby avoiding temperature inversion with minimal off-target drift of the sprayed liquid.

가열시간과 저장온도가 가열팜유의 산화안정성에 미치는 영향 (Effects of Heating Time and Storage Temperature on the Oxidative Stability of Heated Palm Oil)

  • 최은옥
    • 한국식품과학회지
    • /
    • 제29권3호
    • /
    • pp.407-411
    • /
    • 1997
  • 가열시간과 저장온도가 가열팜유의 산화안정성에 미치는 영향을 연구하였다. 팜유는 $150^{\circ}C$에서 0, 1, 10 또는 20분동안 가열된 후 4, 20 또는 $65^{\circ}C$에 넣어 저장하였다. 시료의 산화안정성은 저장중인 시료의 과산화물가와 시료의 headspace에서의 휘발성 물질의 양을 측정함으로써 평가되었다. 4 또는 $20^{\circ}C$에 저장한 가열팜유와 $65^{\circ}C$에 저장한 팜유는 과산화물과 휘발성물질 생성에 유의적인 차이를 나타내었다(p<0.05). Pentane, hexanal, heptane과 total volatile은 가열시간이 증가함에 따라 많이 생성되었으나 저장온도는 유의적으로 그 생성에 영향을 미치지 못하였다. 이것은 가열팜유의 휘발성 물질의 생성에는 저장온도보다 가열시간이 더욱 중요한 역할을 수행함을 의미한다. 그러나 과산화물 생성에는 반대 결과가 관찰되었다. 또한 가열팜유의 산화안정성에 대한 가열시간과 저장온도의 상호효과도 관찰되었다.

  • PDF

Stability of 0ndansetron and Fluconazole in 5% Dextrose Injection and Normal Saline during Y-Site Administration

  • Burm, Jin-Pil
    • Archives of Pharmacal Research
    • /
    • 제20권2호
    • /
    • pp.171-175
    • /
    • 1997
  • The stability of ondansetron and fluconazole in 5% dextrose injection and normal saline during simulated Y-site injection at room temperature was studied. Ondansetron 0.03, 0.1 and 0.3 mg/ml were admixed 1:1 with fluconazole 2 mg/ml. The solutions were stored at room temperature and samples were retrieved at time 0, 1, 2, 4 and 12 hr for immediate assay. At the time of the assay and before any dilution, each sample was visually inspected for clarity, color, precipitation, and the pH was determined. Drug concentrations were measured by a stability-indicating high performance liquid chromatograph. Ondansetron 0.03, 0.1 and 0.3 mg/ml were stable when mixed with concentration of fluconazole 2 mg/ml. There were no change in clarity and color and no precipitates in any admixture for 12 hr of inspection. The pH measurements did not have a particular trend in any direction over time.

  • PDF

Flexible Flat Cable 생산성 향상을 위한 가압용 히팅롤러의 온도제어개선 (Temperature Control Improvement of Pressure Heating Roller for Flexible Flat Cable Production)

  • 김재학;이호중;전경진
    • 한국정밀공학회지
    • /
    • 제22권7호
    • /
    • pp.155-163
    • /
    • 2005
  • Pressure heating rollers with temperature control were mounted to a flat cable laminating machine (FCLM). Pressure heating rollers should be heated up to the setting temperature $(175^{\circ}C)$ and kept on to producing good quality flexible flat cables (FFC). Existing Pressure heating rollers took more than 70minutes to the setting temperature and did not keep on the setting temperature in production. Temperature controller, electric power controller, material and diameter of rollers and heat capacities were changed to improve the temperature control of the pressure heat rollers for better production of the FFC. Thus, the reaching time to the setting temperature (RT), temperature stability time (TST) and temperature hunting (TH) were measured and compared with the existing pressure rollers case. The RT of A roller was shortened by 50minutes, and B roller was shortened by 15minutes. The TST of A roller was shortened by 13minutes, and B roller was shortened by 15minutes. The THs of both A and B rollers were settled up to ${\pm}5^{\circ}C$. Finally, the productivity of the FCLM and the quality of the FFC were increased.

Colloidal Gas Aphrons의 제조와 안정성에 대한 연구 (A Study on Preparation of Colloidal Gas Aphrons and Stability)

  • 윤미해;조대철
    • 대한환경공학회지
    • /
    • 제29권6호
    • /
    • pp.670-677
    • /
    • 2007
  • 비이온성 및 이온성 계면활성제를 이용하여 제조한 CGA(cllodial gas aphron)의 안정성을 고찰하였다. 실험에서 이용한 계면활성제는 SDS(Sigma-Aldrich, Co.), Triton X-100, Tween 80, Quillaja Saponin이다. CGA발생장치를 이용하여 단일 성분의 계면활성제 및 혼합 계면활성제에 의한 CGA를 제조하였고, 농도, 온도, 시간에 따른 CGA의 안정성을 조사하였다. 단일 성분 CGA의 경우, Saponin이 143분의 지속시간을 보여 가장 높은 안정성을 나타내었고 Triton X-100, SDS, Tween 80순으로 안정성이 높았다(상온). CGA제조시 계면활성제 용액을 $70^{\circ}C$로 가열한 경우, SDS가 가장 높은 안정성을 보였으며(116분) Saponin은 상온에 비해 안정성이 낮아졌다. (105분). 혼합 계면활성제일 경우, 두 계면활성제의 중간 수준의 안정성을 보였으며, SDS+Saponin 조합이 139분으로 가장 안정성이 컸다. 가열한 혼합 계면활성제에서는 Saponin+Triton X-100 조합이 가장 안정성이 낮아 53분에 불과했다. CGA는 초기 평균 입경이 약 140 ${\mu}m$ 였다가 융합이 일어나면 그 크기가 약 190 ${\mu}m$로 상승하고 이후 붕괴하는 양상을 띠었다. 가열하여 제조한 CGA에서는, Saponin이 포함된 경우 상온에 비해 그 크기가 감소하였으며, 타 계면활성제에서는 일반적으로 그 크기가 증가하였다. 요약하면 CGA는 가열 했을 때 보다는 상온일때, 분자간 상호작용이 크게 작용하는 혼합 계면활성제보다 단일 계면활성제일 경우, CGA 지속시간이 길어져 안정성이 높아졌다.

잔류 인함량이 옥배유의 변색및 저장안정성에 미치는 영향 (Effects of Residual Phosphorus Content on color Reversion and Storage Stability of Corn Germ Oil)

  • 김종승;이근보;이미숙
    • 한국식품위생안전성학회지
    • /
    • 제12권2호
    • /
    • pp.107-110
    • /
    • 1997
  • To examine the effects of residual phosphorus content on color reversion and storage stability of corn germ oil, the changes of Lovibond total color and stability of oxidation were determined according to the different storage periods at room and incubating temperature, respectively. The residual phosphorus content and storage temperature had the synergistic effect on color reversion during short time storage. The extent of color change was the greatest when oils were stored for 1.0∼1.5 years at room temperature and thereafter gradually tended to reverse color reversion. It is supposed that the double bonds of carotenoids in oils were oxidized and then turned to the volatiles such as epoxide, ionone, and etc. In contrast, the residual phosphorus content increased oxidation stability of oils. The residual phosphorus content was closely correlated with the color reversion and storage stability, respectively.

  • PDF

Effect of extraction conditions on the stability and safety of sericin

  • Ji Hae, Lee;Hyun-Bok, Kim;HaeYong, Kweon
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제45권2호
    • /
    • pp.93-98
    • /
    • 2022
  • To assess the feasibility of silk sericin for non-textile application, the storage stability and biological safety of sericin were examined. It was extracted at 37℃, 70℃, 100℃, and 121℃ for 1, 3, and 5 h to elucidate the effect of extraction condition on the stability and safety of silk sericin. The solubility was increased till approximately 26% with extraction temperature of 121℃ for 1 h. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) showed that the molecular weight distribution depended on the extraction conditions. Extracted sericin displayed typical UV absorption bands upon spectrometric analysis. To examine the reproducibility of its obtained conformation, sericin was extracted thrice and its circular dichroism (CD) spectra was measured each time. Most CD spectra showed reproducibility regardless of temperature and time except under 100℃ extraction condition. The diversity of CD spectrum showed gradual reduction and was finally coincident with extraction time from 1 to 5 h. Notably, sericin has a negative peak of approximately 200 nm attributed to random coil conformation, regardless of extraction condition. However, at the 100℃ extraction condition, sericin showed both bands to be negative bands of approximately 200 and 220 nm, respectively. Sericin was centrifuged to determine the stability of storage conditions. The sericin extracted at 100℃ and 121℃ for 1 h was found to form gel rapidly within 1 h, but at 121℃ condition, the gel fraction was approximately 20% within 1 h which retained its phase regardless of storage time. The gel fraction of sericin extracted at 100℃ for 5 h increased with time, however at the 121℃ for 5 h condition, the gel fraction was measured to be less than 10% regardless of increase in storage time. PetriflimTM AC plates test showed that sericin was safe from aerobic bacteria activity by extraction under high temperature.

난백겔의 열안정성에 관한 연구 1, 가열온도와 시간, pH 및 NaCl농도가 난백겔의 열안정성에 미치는 영향 (Studies on Heat Stability of Egg Albumen Gel 1. Effects of Heating Time and Temperature, PH and NaCl Concentration on Heat Stability of Egg Albumen Gel)

  • 유익종;김창한;한석현;송계원
    • 한국가금학회지
    • /
    • 제17권2호
    • /
    • pp.127-133
    • /
    • 1990
  • 가열온도와 시간, pH 및 NaCl 농도가 난백겔의 열안정성에 미치는 영향을 검토하기 위하여 가열처리 후 난백겔의 특성을 검토하였으며 그 결과는 다음과 같다. 난백을 90~$170^{\circ}C$까지 온도와 시간별 가열처리 한 결과. 110~$130^{\circ}C$ 영역에서 경도가 떨어졌으나 온도가 높아짐에 따라서 급격히 증가하였다. 응집성의 경우는 12$0^{\circ}C$까지 감소한 후 $130^{\circ}C$에서 급격히 증가하였다. 명도는 온도가 높아질수록 시간이 길어질수록 낮아졌으며 황색도는 높아졌다. 난백의 경도는 pH 7을 중심으로 산성영역에서는 고온처리가 높았으며 알카리영역에서 밝았다. 고온처리의 경우가 저온처리에 비해 산성영역에서는 보다 밝았으며 알카리 영역에서는 보다 어두웠다. 염의 첨가에 의해 난백의 경도는 저온처리 시에는 큰 변화가 없었으나 고온처리시 다소 증가하였고 응고집성은 저온처리시 서서히 증가하였으며 고온처리시 0.5%까지 급격히 증가하였다. 색택은 고온고리시 명도가 증가하였고 황색도는 감소하였으며 농도별 차이는 크지 않았다.

  • PDF

가솔린기관의 시동시 기관 제어변수가 배기가스온도 및 시동성에 미치는 영향에 관한 실험적 연구 (Effects of Engine Control Variables on Exhaust Gas Temperature and Stability during Cranking Operation of an SI Engine)

  • 조용석;안재원;박영준;김득상;이성욱
    • 한국자동차공학회논문집
    • /
    • 제15권1호
    • /
    • pp.64-70
    • /
    • 2007
  • Raising exhaust gas temperature during cold-start period is very crucial to improve emission performance of SI engines because it enhances the performance of catalyst in the early stage of engine start. In this study, control variables such as ignition timing, idle speed actuator(ISA) opening and fuel injection duration were extensively investigated to analyze variations in exhaust gas temperature and engine stability during cranking period. Experimental results showed that spark timing affected engine stability and exhaust gas temperature but the effects were small. On the other hand, shortened injection duration and increased ISA opening led to a significant increase in exhaust gas temperature. Under such conditions, increase in cranking time was also observed, showing that it becomes harder to start the engine. Based on these observations, a pseudo fuel-air ratio, defined as a ratio of fuel injection time to degree of ISA opening, was introduced to analyze the experimental results. In general, decrease in pseudo fuel-air ratio raised exhaust gas temperature with the cost of stable and fast cranking. On the contrary, an optimal range of the pseudo fuel-air ratio was found to be between 0.3 to 0.5 where higher exhaust gas temperatures can be obtained without sacrificing the engine stability.

AC PDP의 저온에서의 오방전 개선을 위한 구동 방법 (Driving Method for Mis-discharge Improvement at Low Temperature in AC PDP)

  • 김근수;이석현
    • 전기학회논문지
    • /
    • 제58권6호
    • /
    • pp.1157-1165
    • /
    • 2009
  • In AC-PDP, it is necessary to achieve high luminance efficiency, high luminance and high definition by adopting technologies such as high xenon concentration, MgO doping, and long gap. However, it is very difficult to apply above technologies because they make the driving voltage margin reduced. Especially, high Xe concentration technology for high efficacy makes not only the driving voltage margin reduced but also the stability of reset discharge decreased at low temperature. In this paper, we studied temperature and voltage dependent stability of reset discharge and present the experimental results of the discharge characteristics at low temperature. In addition, we suggested the mechanism of bright noise and black noise at low temperature. Finally, we proposed double reset waveform to improve the bright noise and descending scan time method to improve the black noise.