A Study on the Improvement of Combustion Stability for SI Engine at Idle Operation (SI 기관의 공회전시 연소 안정성 향상에 관한 연구)

  • Lee, J.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.259-266
    • /
    • 1998
  • In the SI engine, the improvement of combustion stability is important not only for the fuel consumption rate but also for the emission control at idling of engine. Thus the engine speed fluctuation at idle operation mainly comes from cyclic variation of combustion in the SI engine. In this syudy, the improvement of combustion stability for the SI engine at idle condition by the cooling water temperature, duty ratio of ISC, spark ignition timing as well as the reducement of the harmful exhaust gas emission was discussed.

  • PDF

Research on high effectiveness solar photovoltaics module choice by climate fluctuation (기후변화에 따른 고효율 태양광 모듈 산정에 관한 연구)

  • Choi, Hong-Kyoo;Choi, Shin-Gwon;Choi, Kyung-Han;Choi, Young-Jun;Choi, Dae-Won;Lee, Jung-Eun;Hwang, Sang-Gu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.67-71
    • /
    • 2009
  • In this treatise, presented module choice plan that analyze relation with meteorological condition (work trillion amounts, mean air temperature, precipitation, cloudiness, wind speed etc.) because diagnoses June output amount of 247.5kW bulk type module and a-Si type module that is established in equal environment in our country and is the high effectiveness enemy more by climate fluctuation by latest global warming back.

  • PDF

Summer, A Study on Characteristic by Photovoltaic Module by Climate Fluctuation (여름철 기후변화에 따른 태양광 모듈별 특성에 관한 연구)

  • Choi, Hong-Kyoo;Choi, Shin-Gwon;Choi, Dae-Won;Lee, Guen-Moo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.75-82
    • /
    • 2009
  • In this thesis, presented module choice plan that analyze relation with weather condition (work trillion amounts, mean air temperature, precipitation, cloudiness, wind speed etc.) because diagnoses June output amount of 247.5[kW] bulk type module and a-Si type module that is established in equal environment in our country and is the high effectiveness enemy more by climate fluctuation by latest global warming back.

Design of PI and Feedforward Controller for Precise Temperature Control of Oil Cooler System (오일쿨러의 고정밀 온도 제어를 위한 PI 및 피드포워드 제어기 설계)

  • Byun, J.Y.;Jeong, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.6
    • /
    • pp.89-95
    • /
    • 2010
  • This paper deals with design method of proportional-integral(PI) and feedforward controller for obtaining precise temperature and high energy efficiency of oil cooler system in machine tools. The compressor's speed and opening angle of an electronic expansion valve are controlled to keep reference value of temperature at oil outlet and superheat of an evaporator. Especially, the feedforward controller is added to suppress temperature fluctuation under abrupt disturbances. Through some experiments, the suggested method can control the target temperature within steady state error of ${\pm}0.l^{\circ}C$ and maximum overshoot $0.2^{\circ}C$ under abrupt disturbances.

Dielectric relaxation properties in the lead scandium niobate

  • Yeon Jung Kim
    • Journal of Surface Science and Engineering
    • /
    • v.56 no.4
    • /
    • pp.227-232
    • /
    • 2023
  • In this study, complex admittance as a function of temperature and frequency was measured to analyze the important relaxation properties of lead scandium niobate, which is physically important, although it is not an environmentally friendly electrical and electronic material, including lead. Lead scandium niobate was synthesized by heat treating the solid oxide, and the conductance, susceptance and capacitance were measured as a function of temperature and frequency from the temperature dependence of the RLC circuit. The relaxation characteristics of lead scandium niobate were found to be affected by contributions such as grain size, grain boundary characteristics, space charge, and dipole arrangement. As the temperature rises, the maximum admittance and susceptance increase in one direction, but the resonance frequency decreases below the transition temperature but increases after the phase transition.

Actual Energy Consumption Analysis of Temperature Control Strategies for Secondary Side Hot Water District Heating System with an Inverter (인버터시스템 적용 지역난방 시스템의 2차측 공급수 온도 제어방안에 따른 에너지사용량 실증 비교)

  • Cho, Sung-Hwan;Hong, Seong-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.179-186
    • /
    • 2015
  • In this study, the actual energy consumption of the secondary side District Heating System (DHS) with different hot water supply temperature control methods is compared. The two methods are Outdoor Temperature Reset Control and Outdoor Temperature Predictive Control. While Outdoor Temperature Reset Control has been widely used for energy savings of the secondary side system, the results show that the Outdoor Temperature Predictive Control method saves more energy. In general, the Outdoor Temperature Predictive Control method lowers the supply temperature of hot water, and it reduces standby losses and increases the overall heat transfer value of heated spaces due to more flow into the space. During actual energy consumption monitoring, the Outdoor Temperature predictive Control method saves about 6.6% of energy when compared to the Outdoor Temperature Reset Control method. Also, it is found that at partial load condition, such as during daytime, the fluctuation of hot water supply temperature with Outdoor Temperature Reset Control is more severe than that with Outdoor Temperature Predictive Control. Thus, it proves that Outdoor Temperature Predictive Control is more stable even at partial load conditions.

Temporal and Spatial Variations in Sea Surface Temperature Around Boryeong off the West Coast of Korea From 2011-2012 (2011-2012년 서해 보령연안 수온의 시공간적 변동)

  • Choo, Hyo-Sang;Yoon, Eun-Chan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.5
    • /
    • pp.497-512
    • /
    • 2017
  • Temporal and spatial variations in surface water temperature were studied using data from temperature monitoring buoys deployed at 47 stations around Boryeong from 2011-2012 off the west coast of Korea. Temperature fluctuations are predominant at diurnal and semidiurnal periods for all seasons, and their amplitudes are large in spring and summer but small in autumn. The maximum annual change in air temperature takes place on August 2nd and August 22th for water temperature, which means the phase for air temperature precedes water temperature by 20 days. The diurnal period of water temperature fluctuation is predominant around Daecheon and Muchangpo Harbors, with the semidiurnal period around Wonsan Island, and the shallow water constituent period on the estuary around Daecheon River. On the whole, air and water temperatures fluctuate with wind. Spectral analyses of temperature records show significant peaks at the 0.5, 1 and 15 day marks with 7-10 day periods of predominant fluctuations. Cross-correlation analyses for the temperature fluctuation show that the waters around Boryeong can be classified into four areas: a mixed water zone around the southeast side of Wonsan Island, an off-shore area to the west, an off-shore area to the south and a coastal area along the shore from Song Island to Muchangpo Harbor.

A Study on the Population Fluctuation of Wintering Waterbirds on Wonju-Stream by the Temperature (원주천 월동 수조류의 기온에 따른 군집 변동에 관한 연구)

  • Park, Yung-Wook;Lee, Hwang-Goo;Choi, Jun-Kil
    • Korean Journal of Environment and Ecology
    • /
    • v.31 no.2
    • /
    • pp.135-151
    • /
    • 2017
  • Waterbirds were surveyed once a week from Oct. 2015 to Apr. 2016 to study the conditions of temperature of staying waterbirds on Wonju-Stream. The population staying on Wonju-Stream was in inverse proportion to the temperature change; birds increased as the temperature went down, and showed the highest peak counts on the 16th(27-Jan) survey, which was the lowest in temperature. decreasing as the temperature rose. The total population of Wonju River water birds increased with increasing freezing rate in proportion to the freezing rate of nearby reservoirs and tributaries. To clarify the relation of the numbers of the birds to temperature fluctuation, the correlation of the first period of wintering (1st~16th) and that of the later period(17th~27th) as well as the whole period was surveyed, based on the 16th which was the lowest in temperature. While most wintering waterbirds showed a negative correlation to the temperature, Egretta garzetta, Phalacrocorax carbo, and Ardea cinerea were positive in temperature relativity. Anas poecilorhyncha was in the highest relation to temperature fluctuation showing (7D/H3A(r=-0.960, P<0.000000001)) at 1-16 correlation(Cor.), with the whole wintering waterbird species showing the maximum correlation at 4D/LA in the every correlation(1~27Cor.(r=-0.942, P<0.01), 1~16Cor.(r=-0.947, P<0.01), 16~27Cor.(r=-0.958, P<0.01)). Each waterbird showed the correlation to the temperature variation(AT, HT, LT) and th duration(1D~7D) depending on the species differently. Most species demonstrated a bigger correlation to the lowest temperature rather than to the highest temperature. During the first half period of the wintering with the temperature falling it showed a high correlation to the temperature at the duration of 4D~7D, While it was for D1~D3 during the next half period.

Investigation of thermal hydraulic behavior of the High Temperature Test Facility's lower plenum via large eddy simulation

  • Hyeongi Moon ;Sujong Yoon;Mauricio Tano-Retamale ;Aaron Epiney ;Minseop Song;Jae-Ho Jeong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3874-3897
    • /
    • 2023
  • A high-fidelity computational fluid dynamics (CFD) analysis was performed using the Large Eddy Simulation (LES) model for the lower plenum of the High-Temperature Test Facility (HTTF), a ¼ scale test facility of the modular high temperature gas-cooled reactor (MHTGR) managed by Oregon State University. In most next-generation nuclear reactors, thermal stress due to thermal striping is one of the risks to be curiously considered. This is also true for HTGRs, especially since the exhaust helium gas temperature is high. In order to evaluate these risks and performance, organizations in the United States led by the OECD NEA are conducting a thermal hydraulic code benchmark for HTGR, and the test facility used for this benchmark is HTTF. HTTF can perform experiments in both normal and accident situations and provide high-quality experimental data. However, it is difficult to provide sufficient data for benchmarking through experiments, and there is a problem with the reliability of CFD analysis results based on Reynolds-averaged Navier-Stokes to analyze thermal hydraulic behavior without verification. To solve this problem, high-fidelity 3-D CFD analysis was performed using the LES model for HTTF. It was also verified that the LES model can properly simulate this jet mixing phenomenon via a unit cell test that provides experimental information. As a result of CFD analysis, the lower the dependency of the sub-grid scale model, the closer to the actual analysis result. In the case of unit cell test CFD analysis and HTTF CFD analysis, the volume-averaged sub-grid scale model dependency was calculated to be 13.0% and 9.16%, respectively. As a result of HTTF analysis, quantitative data of the fluid inside the HTTF lower plenum was provided in this paper. As a result of qualitative analysis, the temperature was highest at the center of the lower plenum, while the temperature fluctuation was highest near the edge of the lower plenum wall. The power spectral density of temperature was analyzed via fast Fourier transform (FFT) for specific points on the center and side of the lower plenum. FFT results did not reveal specific frequency-dominant temperature fluctuations in the center part. It was confirmed that the temperature power spectral density (PSD) at the top increased from the center to the wake. The vortex was visualized using the well-known scalar Q-criterion, and as a result, the closer to the outlet duct, the greater the influence of the mainstream, so that the inflow jet vortex was dissipated and mixed at the top of the lower plenum. Additionally, FFT analysis was performed on the support structure near the corner of the lower plenum with large temperature fluctuations, and as a result, it was confirmed that the temperature fluctuation of the flow did not have a significant effect near the corner wall. In addition, the vortices generated from the lower plenum to the outlet duct were identified in this paper. It is considered that the quantitative and qualitative results presented in this paper will serve as reference data for the benchmark.

Phase-Resolved CARS Temperature Measurement in a Lean Premixed Gas Turbine Combustor (I) -Effect of Equivalence Ratio on Phase-Resolved Gas Temperature- (CARS를 이용한 희박 예혼합 가스터빈 연소기내 온도 측정 (I) -연료/공기 혼합정도가 위상별 온도에 미치는 영향-)

  • Lee Jong Ho;Jeon Chung Hwan;Park Chul Woong;Hahn Jae Won;Chang Young June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.10
    • /
    • pp.1184-1192
    • /
    • 2004
  • Experimental investigations were carried out in an atmospheric pressure, optically accessible and laboratory-scale dump combustor operating on methane gas. The objective of this study was to obtain the phase-resolved gas temperatures at different phases of the oscillating pressure cycle during unstable combustion. CARS temperature measurements were made at several spatial locations under lean premixed conditions to get the information on temperature field within the combustor. Also the effect of incomplete fuel-air mixing on phase-resolved temperature fluctuation was investigated. Results including phase-resolved averaged temperature, normalized standard deviation and temperature probability distribution functions (PDFs) were provided in this paper. Temperature PDFs gave an insight on the flame behavior. And strong correlation between phase-resolved temperature profile and pressure cycle was observed. Results of the phase-resolved high temperature gave an additional information on the perturbation of equivalence ratio at flame as well as the effect of mixing quality on NOx emission characteristics.