• 제목/요약/키워드: Temperature declination

검색결과 7건 처리시간 0.024초

대형 주.단조품의 온도 및 조직변화 예측에 관한 연구 (On prediction temperature and microstructure change in large cast-forged product)

  • 이명원;이영선;이승욱;김상식;문영훈
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 추계학술대회 논문집
    • /
    • pp.414-419
    • /
    • 2009
  • Good control of thermal energy helps to increase characteristics and eliminate defects of large cast-forged part, such as large sized forged shell. Thermal energy control is a important factor. We have studied about forging process and after heat treatment process by FEM simulation. There are three ways of process. Changes of temperature and microstructure for forged shell were predicted according to temperature declination in large cast-forged product. So we will be able to choose the proper time from heat treatment conditions by FEM simulation.

  • PDF

동절기 매트기초공사시 콘크리트의 초기동해방지 및 온도충격제어에 관한 해석적 연구 (An Analytic Study on Early aged Freezing Damage Prevention and Thermal Crack Control of Concrete in Cold-Weathering Mat Foundation Construction)

  • 이도범;김효락;박지훈;최일호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.807-812
    • /
    • 2001
  • This study is peformed for checking the limitation and application of each curing/heating methods on cold-weathering mat foundation construction, considering temperature control, early strength security and temperature declination range limit, by means of concrete material properties and thermal analysis technique that were published previously. In the result of this analysis, we checked the open air temperature and mat depth that are possible to apply each curing/heating methods on cold-weathering construction and found curing/heating time of each methods that is able to prevent early aged freezing damage and thermal crack

  • PDF

산소/수소안정동위원소를이용한지하수-지표수연계성연구: 논산시왕전리수막 재배지역 사례 (O/H Stable Isotopic Composition and Groundwater-surface Water Connectivity: A Case Study for Wangjeon-ri Water Curtain Cultivation Area, Nonsan, Korea)

  • 문상호
    • 자원환경지질
    • /
    • 제51권6호
    • /
    • pp.567-577
    • /
    • 2018
  • 우리나라에서 수막재배가 주로 이루어지는 수변지역에서는 수막재배 성수기 말기에 지하수위 하강이 심하게 나타나는 문제점이 있으며, 이러한 지하수위 하강과 지하수 자원 고갈의 문제는 인근 하천수와의 연계 특성을 고려할 때 효율적으로 해결할 수 있을 것이다. 이 연구에서는 수막재배지에서의 지하수와 하천수와의 연계성 및 지하수 대수층에 미치는 하천수의 영향 범위를 논의하기 위해, 지하수의 토출온도, 지하수와 하천수의 산소 수소 안정동위원소 조성 변화 특성을 검토하였다. 연구지역은 딸기 수막재배지로 잘 알려진 논산시 광석면 왕전리 지역이며, 지하수와 하천수의 시료 채취는 2010년 2월부터 2011년 6월까지 실시되었다. 지하수의 수온 분포 패턴에 의하면, 하천수의 영향은 주로 수막재배지의 우측 부분에서 넓은 범위에 걸쳐 나타났으며, 좌측 부분은 하천 인근에서만 좁은 범위의 영향을 받고 있는 것으로 나타났다. 이러한 현상은 수막재배지 내에서 산출되는 지하수의 산소 수소 안정동위원소 조성에서도 유사한 양상으로 나타났다.

남극 세종기지에서의 지자기 모니터링 (Geomagnetic Field Monitoring at King Sejong Station, Antarctica)

  • 김동일;진영근;남상헌;이주한
    • 지구물리
    • /
    • 제7권1호
    • /
    • pp.11-21
    • /
    • 2004
  • The variation of geomagnetic field and absolute magnetic field at the geomagnetic observatory of King Sejong Station has been measured with 3-component ring core fluxgate magnetometer, proton magnetometer and D-I magnetometer. With data obtained from King Sejong Station during 2003, thediurnal and annual variations of geomagnetic field were researched and compared with those at other observatories. The deviation of daily variation of magnetic field in antarctica decreased gradually during winter season due to sun effect. The rates of componental annual variation of magnetic field at King Sejong Station were calculated using the least-square method under the assumption that the annual variation of magnetic field is linear. The rates are -55.93 nT/year in horizontal intensity, -0.87 min./year in declination, 58.30 nT/year in vertical intensity, and -69.85 nT/year in total intensity of magnetic field. A remarkable variation was caused by the magnetic storms occurred on 29~30 October, which were so powerful that the variation was observed in mid latitudes as well as high latitudes. The values of variation are generally 1500 2000 nT in Antarctica including King Sejong Station, 350 500 nT in East Asia. The measurement of absolute magnetic field shows that ring core fluxgate magnetometer has relatively large error range under cold temperature.

  • PDF

냉난방용 디지털 온도조절계의 편차 정동작 특성에 관한 연구 (A Study on the Characteristic of Declination Forward Action of Digital Temperature Controller using air Cool-Heating)

  • 위성동;구할본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.41-46
    • /
    • 2002
  • 본 논문은 냉, 난방 디지털 온도 조절계(SPC 50)의 Etl의 편차 정 동작에 관한 구현장치 제작과 비례 미.적분기가 At 및 비 At기능에서 설정온도를 $100^{\circ}C$를 유지하는데 기인된 전압전류 및 전력데이터 획득의 요인과 비례미적분 정수 및 노 개선점을 연구하였다. 설정온도를 유지하는 온도변화는 At기능에서 $96.7^{\circ}C\sim102^{\circ}C$ 이며, 비At 기능에서는 $97.6^{\circ}C\sim100.2^{\circ}C$이었다. 온도유지 전압변동은 At기능에서 2V~217V이며, 비 At기능에서 20V~217V 이었다. At와 비 At 기능에서 설정온도 $100^{\circ}C$을 유지하는데 온도를 냉각시키는 환풍기가 온. 오프 되는 시간차는 20초 정도 발생하였다. 온도차 및 전압차는 두 기능간에 비례 미. 적분값 설정이 자동 및 수동이냐에 따라서 차이를 보여주었다. 두 기능에서 설정된 온도값 유지에 따른 전압전류의 승압과 하강의 변동된 변환 데이터는 설정된 온도가 성취되어지는 시간차 및 설정값 유지의 특성을 요인으로 한 PID값과 노의 개선점에 길잡이가 된다.

  • PDF

SPS 소결에 의한 $SiC-ZrB_2$ 도전성 세라믹 복합체 특성 (Properties of $SiC-ZrB_2$ Electroconductive Ceramic Composites by Spark Plasma Sintering)

  • 주진영;이희승;조성만;이정훈;김철호;박진형;신용덕
    • 전기학회논문지
    • /
    • 제58권9호
    • /
    • pp.1757-1763
    • /
    • 2009
  • The composites were fabricated by adding 0, 15, 20, 25[vol.%] Zirconium Diboride(hereafter, $ZrB_2$) powders as a second phase to Silicon Carbide(hereafter, SiC) matrix. The physical, mechanical and electrical properties of electroconductive SiC ceramic composites by Spark Plasma Sintering(hereafter, SPS) were examined. Reactions between ${\beta}-SiC$ and $ZrB_2$ were not observed in the XRD analysis. The relative density of mono SiC, SiC+15[vol.%]$ZrB_2$, SiC+20[vol.%]$ZrB_2$ and SiC+25[vol.%]$ZrB_2$ composites are 90.93[%], 74.62[%], 74.99[%] and 72.61[%], respectively. The XRD phase analysis of the electroconductive SiC ceramic composites reveals high of SiC and $ZrB_2$ and low of $ZrO_2$ phase. The lowest flexural strength, 108.79[MPa], shown in SiC+15[vol.%] $ZrB_2$ composite and the highest - 220.15[MPa] - in SiC+20[vol.%] $ZrB_2$composite at room temperature. The trend of the mechanical properties of the electroconductive SiC ceramic composites moves in accord with that of the relative density. The electrical resistivities of mono SiC, SiC+15[vol.%]$ZrB_2$, SiC+20[vol.%]$ZrB_2$ and SiC+25[vol.%]$ZrB_2$ composites are 4.57${\times}10^{-1}$, 2.13${\times}10^{-1}$, 1.53${\times}10^{-1}$ and 6.37${\times}10^{-2}$[${\Omega}$ cm] at room temperature, respectively. The electrical resistivity of mono SiC, SiC+15[vol.%]$ZrB_2$. SiC+20[vol.%]$ZrB_2$ and SiC+25[vol.%]$ZrB_2$ are Negative Temperature Coefficient Resistance(hereafter, NTCR) in temperature ranges from 25[$^{\circ}C$] to 100[$^{\circ}C$]. The declination of V-I characteristics of SiC+20[vol.%]$ZrB_2$ composite is 3.72${\times}10^{-1}$. It is convinced that SiC+20[vol.%]$ZrB_2$ composite by SPS can be applied for heater or electrode above 1000[$^{\circ}C$]

평면식 태양열 집열기의 성능에 관한 연구 (Study on the Performance of the Flat-Plate Solar Collectors)

  • 장규섭;김만수
    • Journal of Biosystems Engineering
    • /
    • 제2권2호
    • /
    • pp.37-45
    • /
    • 1977
  • Solar energy is a potential source of power that offers much promise being used for low-temperature applications like drying farm crops, space heating, and water heating for domestic uses. Already much of it are being used for those purpose in foreign countries. However, very little research has been done to determine the possibility of using the solar energy in Korea. This study was conducted to develop the general prediction equation of the total radiation on a horizontal surface in Daejeon area based on 5 years 91972, Jun.1-1976. Dec.31) meteorological data (bright sunshine hours, average total horizontal radiation), and to obtain experimentally the thermal efficiency of solar air and water collectors, which will be used as a basic data of designing flat-plate solar collector system.In addition to the thermal efficiency of the collectorsthe relationship among those factors affecting it such as weather condition, orientation factor, and tilted angle of collector was analyzed. The results of this study were as follows. 1. The general predicted equation of the total radiation on a horizontal surface in Daejeon area based on bright sunshine hours was developed as $H_{av} =(1.546\frac{n}{N}-0.582)H_o$. Predicting the total radiation on a horizontal surface by the above equation was thought to be possible because to values of 0.882 was smaller than any t values at above 0.05 level on the basis of two tailed test of the difference between the calculated and the recorded values. 2.It was observed that optimum tilt angle of the collector in the summer and the autumn drying season was 13 degrees and 51 degrees respectively, these values could be obtained by adding or substracting approximately 25 degrees from the latitude of this area $(36.3^{\circ}N)$ .The relationship between orientation factor and declination of sun at suitable tilt angle of 33 degrees $(s=0.9\O)$ was shown at Fig.4. 3.The thermal efficiency of solar wdter collector was shown 13.4-51. 6% on Aug. 15 (the minimum radiation recorded) and 43.8 ~537% Aug.20 (the maximum radiation recorded), and 13.8~ 46.6 and 44.3~ 49.7 were shown on each corresponding day. 4.The thermal efficiency of the collectors according to the weather condition was shown a big difference of about 10% between the day of the maximum radiation recorded and the minimum, but the differen of efficiency between the air and the water collector was at most 2 ~ 3%. 5. Even if the efficiency of the solar water collector was a little higher than the solar air collector, for drying farm products, the solar air collector was thought to be more effective because the air heated by collector could be directly used for drying them.

  • PDF